Click on Series name for product info on aimtec.com Series AM10EW-Z 10 Watt | DC-DC Converter FEATURES: * RoHS compliant * Efficiency up to 85% * Wide 4:1 input range * Continuous Short Circuit Protection * * Low ripple and noise Remote on/off control Input/Output Isolation 1500VDC Operating temperature -40oC to + 85oC Models Single output Model AM10EW-2403SZ AM10EW-2405SZ AM10EW-2412SZ AM10EW-2415SZ AM10EW-4803SZ AM10EW-4805SZ AM10EW-4812SZ AM10EW-4815SZ Input Voltage (V) Output Voltage (V) Output Current max (A) Capacitive load max (F) Efficiency (%) 9-36 9-36 9-36 9-36 18-72 18-72 18-72 18-72 3.3 5 12 15 3.3 5 12 15 2 2 0.83 0.67 2 2 0.83 0.67 3300 3300 680 470 3300 3300 680 470 80 82 85 85 79 82 85 85 Input Voltage (V) Output Voltage (V) Output Current max (A) Capacitive load (F) Efficiency (%) 2200 470 330 2200 470 330 82 85 85 82 85 85 Models Dual output Model AM10EW-2405DZ AM10EW-2412DZ AM10EW-2415DZ AM10EW-4805DZ AM10EW-4812DZ AM10EW-4815DZ 9-36 9-36 9-36 18-72 18-72 18-72 5 12 15 5 12 15 1 0.416 0.333 1 0.416 0.333 Input Specifications Parameters Voltage range Nominal 24 48 Filter Remote ON/OFF Control ON OFF Turn on Transient process time Start up time Absolute Maximum Rating 24 Vin 48 Vin Peak Input Voltage time Typical Maximum 9-36 18-72 (Pi) Network 2.5~5.5 or open circuit -0.7~ 0.8 or short circuit b/n pin 2 & 1 350 20 -0.7-40 -0.7-80 100 Units VDC VDC ms ms VDC ms Isolation Specifications Parameters Tested I/O voltage Case/ Input & Output Resistance Capacitance www.aimtec.com F 051e R12.G Conditions Typical 3 sec Rated 1500 1000 > 1000 1200 Tel: +1 514 620 2722 1 of 3 Units VDC VDC MOhm pF Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AM10EW-Z 10 Watt | DC-DC Converter Output Specifications Parameters Voltage accuracy Voltage balance (Dual output) Short Circuit protection Short Circuit restart Current limiting Line voltage regulation Load voltage regulation Temperature coefficient Ripple & Noise Rising time Conditions Typical Maximum 1 1 Continuous Auto Recovery Balance Load % % 140 HL-LL 10-100% load 20Mhz bandwidth Units 0.5 1.0 0.02 75 10 % of Iout max % % %/oC mV p-p ms General Specifications Parameters Switching frequency Operating temperature Storage temperature Max case temperature Cooling Humidity Case material Weight Dimensions (L x W x H) MTBF Conditions Typical 100% load No derating 300 Maximum Units 100 KHz oC oC oC 95 % -40 to +85 -40 to +125 Free air convection Nickel coated copper 31 g Tolerance 0.5mm 2.00 x 1.00 x 0.40 inches 50.80 x 25.00 x 10.16 mm >1 121 000 hrs (MIL-HDBK -217F, Ground Benign, t=+25oC) NOTE: All specifications in this datasheet are measured at an ambient temperature of 25C, humidity<75%, nominal input voltage and at rated output load unless otherwise specified. Safety Specifications Parameters Agency Approvals Standards CE, cULus IEC/UL/EN/62368-1 EN55032 Class A IEC61000-4-2, Perf. Criteria B IEC61000-4-3, Perf. Criteria A IEC61000-4-4, Perf. Criteria B IEC61000-4-6, Perf. Criteria A IEC61000-4-8, Perf. Criteria A Pin Out Specifications Pin Single Dual 1 2 3 4 5 6 On/Off Control -V Input +V Input -V Output No Pin +V Output On/Off Control -V Input +V Input -V Output Common +V Output www.aimtec.com F 051e R12.G Tel: +1 514 620 2722 2 of 3 Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AM10EW-Z 10 Watt | DC-DC Converter Dimensions 5.08 (0.20) Min 10.16 (0.40) DIA 1.00 (0.04) Bottom View 10.16 (0.40) 3 7.62 5.08 (0.30) (0.20) 5 2 10.16 (0.40) 1 4 20.32 (0.80) 2.54 (0.10) 25.40 (1.00) 10.16 (0.40) 6 15.24 (0.60) Built-in Stand-offs to ease PCB cleaning 2.54 (0.10) 50.80 (2.00) 15.24 (0.60) Notes: All dimensions are typical in millimeters (inches). Tolerance 0.25 (0.01) Test Circuit Conducted Emissions NOTE: 1. Datasheets are updated as needed and as such, specifications are subject to change without notice. Once printed or downloaded, datasheets are no longer controlled by Aimtec; refer to www.aimtec.com for the most current product specifications. 2. Product labels shown, including safety agency certifications on labels, may vary based on the date manufactured. 3. Mechanical drawings and specifications are for reference only. 4. All specifications are measured at an ambient temperature of 25C, humidity<75%, nominal input voltage and at rated output load unless otherwise specified. 5. Aimtec may not have conducted destructive testing or chemical analysis on all internal components and chemicals at the time of publishing this document. CAS numbers and other limited information are considered proprietary and may not be available for release. 6. This product is not designed for use in critical life support systems, equipment used in hazardous environments, nuclear control systems or other such applications which necessitate specific safety and regulatory standards other the ones listed in this datasheet. 7. Warranty is in accordance with Aimtec's standard Terms of Sale available at www.aimtec.com. www.aimtec.com F 051e R12.G Tel: +1 514 620 2722 3 of 3 Toll free: + 1 888 9 AIMTEC (924 6832) North America only