Frequency Range
1 to 800 MHz (ACMOS and TTL outputs available up to
125 MHz. LVPECL and LVDS output frequencies above
220 MHz are achieved through the use of a PLL multiplier.)
Parameter
Min
Typ
Max
Units
Condition
Ordering Code5
Operating temperature range
-100
+100
ppm
0 … +70°C
C104
(referenced to +25°C)
-50
+50
ppm
0 … +70°C
C505
-25
+25
ppm
0 … +70°C
C255
-15
+15
ppm
0 … +70°C
C155
-100
+100
ppm
-40 +85°C
F104
-50
+50
ppm
-40 … +85°C
F505
-25
+25
ppm
-40 … +85°C
F255
-100
+100
ppm
-55 +125°C
M104
-65
+65
ppm
-55 +125°C
M655
Initial accuracy (do not use with
-15
+15
ppm
@ 25°C
T155
overall tolerance code below)
-25
+25
ppm
@ 25°C
T255
-50
+50
ppm
@ 25°C
T505
-100
+100
ppm
@ 25°C
T104
Parameter
Min
Typ
Max
Units
Condition
Ordering Code 5
Overall tolerance (includes operating
-100
+100
ppm
0 +70°C
TC104
temperature and initial accuracy) 7
-50
+50
ppm
0 +70°C
TC505
-25
+25
ppm
0 +70°C
TC255
-100
+100
ppm
-40 +85°C
TF104
-50
+50
ppm
-40 +85°C
TF505
-100
+100
ppm
-55 +125°C
TM104
-80
+80
ppm
-55 +125°C
TM805
Additional stability parameters:
vs. Supply voltage change
vs. Load change
vs. Aging / 1st year
vs. Aging / year (following years)
-2
-1
-3
-1
+2
+1
+3
+1
ppm
ppm
ppm
ppm
VS ± 5%
Load ± 5%
Parameter
Min
Typ
Max
Units
Condition
Ordering Code5
Supply voltage
4.75
5.0
5.25
VDC
SV050
Current consumption
15
mA
ACMOS or TTL 1.0 to 23.9 MHZ
(+5 VDC)
20
mA
ACMOS or TTL 24 to 49.9 MHz
40
mA
ACMOS or TTL 50 to 125.00 MHz
Supply voltage
3.135
3.3
3.465
VDC
SV033
Supply voltage
2.375
2.5
2.625
VDC
SV025
Current consumption
6
mA
ACMOS 1.0 to 14.90 MHZ
(+3.3 VDC or +2.5 VDC)
8
mA
ACMOS 15.0 to 39.9 MHz
16
mA
ACMOS 40.0 to 84.9 MHz
40
mA
ACMOS 85.0 to 125.0 MHz
75
mA
LVPECL or LVDS No load <200 MHz
100
mA
LVPECL or LVDS No load >200 MHz
RF Output
Typical Applications
Features
Military Systems
5X7 Surface Mount Package
Avionics and Instrumentation
Reflow Process Compatible
Test Equipment
ACMOS, TTL, LVPECL and LVDS
Medical Equipment
MIL-PRF-55310 Class B Screening (optional)
Military Operating Temperature Range (optional)
Vectron International · www.vectron.com v.2019-01-16 · page 1 of 4 DAF
C1250
PXO
Vectron International
Headquarters
267 Lowell Road
Hudson, New Hampshire 03051
+1-888-328-7661 tel
+1-888-329-8328 fax
Vectron International LLC.
100 Watts Street
Mount Holly Springs, PA 17065
USA
+1-717-486-3411 tel
+1-717-486-5920 fax
Vectron international GmbH & Co. KG
Landstrasse
D-74924 Neckarbischofsheim
Germany
+49-07268-801-0 tel
+49-07268-801-281 fax
Vectron Asia Pacific Sales Office
Unit 3119 31st Floor, Jin Mao Tower, 88
Century Boulevard, Shanghai,
P.R. China 200120
+86 21 28909740 tel.
+86 21 28909240 fax
Parameter
Min
Typ
Max
Units
Condition
Ordering Code5
Signal
ACMOS
RFA
Load
15
50
pF
Signal Level (Vol)
0.5
VDC
Vs= 5.0V and 15pF load
0.3
VDC
Vs=3.3V and 15pF load
0.25
VDC
Vs=2.5V and 15pF load
Signal Level (Voh)
4.5
VDC
Vs= 5.0V and 15pF load
3.0
VDC
Vs=3.3V and 15pF load
2.25
VDC
Vs=2.5V and 15pF load
Rise and fall times for ACMOS
(measured 10% to 90%)
10
6
3
ns
ns
ns
1.0 to 23.9 MHz
24.0 to 79.9 MHz
80.0 to 125.0MHz
Duty cycle
45
40
55
60
%
%
@ 50% Vs< 15 MHz
@ 50% Vs > 15 MHz
Signal
TTL
RFT
Load
10
Signal Level (Vol)
0.4
VDC
Vs= 5.0V and 15pF load
Signal Level (Voh)
2.4
VDC
Vs= 5.0V and 15pF load
Rise and fall times for TTL
(measured 0.8V to 2.0V)
5
3
ns
ns
1.0 to 23.9 MHz
24 to 125 MHz
Duty Cycle
45
40
55
60
%
%
@ 1.4V < 15 MHz
@ 1.4V > 15 MHz
Signal
LVPECL
RFP
Load
50
Ω
Into Vcc-2V or Thevenin Equivalent
Signal Level (Vol)
Vs -1.62
VDC
-40 … +85°C operating temp
Signal Level (Voh)
Vs- 1.025
VDC
-40 … +85°C operating temp
Rise and fall times (measured @ 20%
to 80%)
1000
600
ps
ps
<100 MHz
> 100 MHz
Duty cycle LVPECL
45
55
%
@ 50% Vdd
Jitter (rms)
10
0.5
ps
ps
BW = 10Hz to 20 MHz
BW = 12 kHz to 20 MHz
Period Jitter (pk-pk)
40
ps
10,000 Samples - Rising edge
Signal
LVDS
RFL
Load
60
100
140
Ω
Between outputs
Signal Level (Vol)
1.2
VDC
Signal Level (Voh)
1.4
VDC
Differential Voltage (Vod)
240
330
460
mVpeak
Common Mode (Offset) Voltage (Vos)
1.125
1.2
1.375
V
Start-up Time
10
mS
Rise and fall times
600
1000
ps
measured @ 20% to 80% of Vod
Duty cycle
45
55
%
@ 50% of Vod
Jitter (rms)
5
1
ps
ps
BW = 10Hz to 20 MHz
BW = 12 kHz to 20 MHz
Period Jitter (pk-pk)
40
ps
10,000 Samples - Rising edge
Additional Parameters
Screening
Vectron Verification9
V
Screening
Class B, MIL-PRF-55310, Rev.D
B
Output Enable6
Logic "0" input = Outputs disabled (Tri-state)
Logic "1" or floating input = Outputs enabled)
Standard ACMOS,TTL and LVDS
Logic "0" or floating input = Outputs enabled
Logic "1" input = Outputs disabled (Tri-state)
Standard LVPECL
Weight
< 2 grams
Processing & Packing
Handling & processing note
Vectron International · www.vectron.com v.2019-01-16 · page 2 of 4 DAF
C1250
PXO
Vectron International
Headquarters
267 Lowell Road
Hudson, New Hampshire 03051
+1-888-328-7661 tel
+1-888-329-8328 fax
Vectron International LLC.
100 Watts Street
Mount Holly Springs, PA 17065
USA
+1-717-486-3411 tel
+1-717-486-5920 fax
Vectron international GmbH & Co. KG
Landstrasse
D-74924 Neckarbischofsheim
Germany
+49-07268-801-0 tel
+49-07268-801-281 fax
Vectron Asia Pacific Sales Office
Unit 3119 31st Floor, Jin Mao Tower, 88
Century Boulevard, Shanghai,
P.R. China 200120
+86 21 28909740 tel.
+86 21 28909240 fax
Standard Environmentals
Parameter
Test Condition
Vibration
MIL-STD-202, Method 204, Condition G (30 G, 10Hz-2000Hz)
Shock
MIL-STD-202, Method 213, Condition I (100 G, 6ms, Sawtooth)
Acceleration
MIL-STD-883, Method 2001, Condition A (5000 G, Y1 Plane)
Temperature Cycling
MIL-STD-883, Method 1010, Condition B
Thermal Shock
MIL-STD-883, Method 107, Condition B
Solderability
MIL-STD-202, Method 208
Leak Test (Fine and Gross)
MIL-STD-883, Method 1014, Condition A1 and C1
Parameter
Min
Typ
Max
Units
Condition
Supply voltage (Vs)
7.0
V
Vs=5.0VDC
7.0
V
Vs=3.3VDC
Operable temperature range
-55
+125
°C
Storage temperature range
-62
+125
°C
Enclosures
Type A ACMOS or TTL
Type B LVPECL or LVDS
Package Codes:
Codes
Height
Codes
Height
A1 = 4 leads
0.074 ± 0.007
B1 = 6 leads
0.074 ± 0.007
E1 = Enable/Disable pin 1
(1.88 ± 0.178)
E1 = Enable/Disable pin 1
(1.88 ± 0.178)
X = N/C pin 1
E2 = Enable/Disable pin 2
X = N/C pin 1 and pin 2
T= Tinned leads 8
T= Tinned leads 8
X= No Tinning
X = No Tinning
Pin Connections
Pin Connections
Vectron International · www.vectron.com v.2019-01-16 · page 3 of 4 DAF
1 Enable/Disable or N/C 3 RF Output 1 Enable/Disable or N/C 4 RF Output
2 Ground (case) 4 Supply Voltage 2 Enable/Disable or N/C 5 Complementary Output
3 Ground (Case) 6 Supply Voltage
Note: Overall package thickness tolerance will be increase from +/- .007 to +/- .015 when I/O pads are solder coated.
C1250
PXO
Vectron International
Headquarters
267 Lowell Road
Hudson, New Hampshire 03051
+1-888-328-7661 tel
+1-888-329-8328 fax
Vectron International LLC.
100 Watts Street
Mount Holly Springs, PA 17065
USA
+1-717-486-3411 tel
+1-717-486-5920 fax
Vectron international GmbH & Co. KG
Landstrasse
D-74924 Neckarbischofsheim
Germany
+49-07268-801-0 tel
+49-07268-801-281 fax
Vectron Asia Pacific Sales Office
Unit 3119 31st Floor, Jin Mao Tower, 88
Century Boulevard, Shanghai,
P.R. China 200120
+86 21 28909740 tel.
+86 21 28909240 fax
How to Order this Product: 10
Step 1
Use this worksheet to forward the following information to your factory representative (example follows):
Model
Stability
Code
Initial Accuracy
Code
(if required)
Supply Voltage
Code
RF Output
Code
Screening
Code
Package
Code
Enable/Disable
Code
Tinning
Code
C1250
C505
T505
SV033
RFA
V
A1
E1
T
Step 2
The factory representative will then respond with a Vectron Part Number in the following configuration:
Model
Package Code
Dash
Dash Number
C1250
[Customer Specified Package Code]
-
[Factory Generated 4 digit number]
Typical P/N C1250A1-0001
1
Contact factory for improved stabilities or additional product options. Not all options and codes are available at all frequencies, RF
outputs and supply voltages.
2
Unless otherwise stated all values are valid after warm-up time and refer to typical conditions for supply voltage, frequency control
voltage, load, temperature (25°C).
3
Phase noise degrades with increasing output frequency.
4
Subject to technical modification.
5
Contact factory for availability.
6
Contact factory for other options.
7
Overall stabilities do not require an initial accuracy code.
8
Leads tinned IAW Vectron International standard procedure (GR-37409).
9
Vectron Verification IAW Vectron International standard process (HK-69314).
10
Please be sure to specify nominal frequency.
Vectron International · www.vectron.com v.2019-01-16 · page 4 of 4 DAF