R F C o m p o n e n t s January 2019 Multilayer Low Pass Filter For 1427.9-2170MHz DEA162170LT-5039A5 1.6x0.8mm [EIA 0603]* * Dimensions Code JIS[EIA] RF Components Multilayer Low Pass Filter Conformity to RoHS Directive For 1427.9-2170MHz DEA162170LT-5039A5 SHAPES AND DIMENSIONS [Top view] 1.600.10 (5) (1) (2) (4) 0.800.10 (6) 0.600.10 (3) Marking [Bottom view] 0.250.10 0.150.10 0.550.10 0.100.10 0.300.10 Terminal functions 1 GND 2 Output Port 3 GND 4 GND 5 Input Port 6 GND Dimensions in mm RECOMMENDED LAND PATTERN 0.25 0.30 0.60 0.30 EVALUATION BOARD Thru Hole Dimensions in mm Resist Surface Pattern Material & Layer Top Resist Copper Surface Pattern FR4 Copper Bottom GND Thickness - 0.035mm 0.40mm 0.035mm Line width should be designed to match 50 characteristic impedance, depending on PCB material and thickness. RoHS Directive Compliant Product: See the following for more details.https://product.tdk.com/info/en/environment/rohs/index.html * All specifications are subject to change without notice. * Before using these products, be sure to request the delivery specifications. 20190114 / rf_lpf_dea162170lt-5039a5_en.fm RF Components DEA162170LT-5039A5 ELECTRICAL CHARACTERISTICS Frequency Range (MHz) Item Insertion Loss (dB) Return Loss (dB) Attenuation (dB) Ripple (dB) Power Handling (W) Characteristic Impedance () 1427.9 to 2025 2025 to 2170 1427.9 to 2025 2025 to 2170 1427.9 to 2025 2025 to 2170 2855 to 6075 6075 to 7500 7500 to 9050 9050 to 9400 9400 to 12750 1427.9 to 2170 Min. Typ. Max. -- -- -- -- 16 16 22 20 14 14 8 -- -- 0.45 0.60 -- -- 21 26 27 29 22 21 14 0.34 -- 50 (Nominal) 0.65 0.85 0.75 (-40 to +85C) 0.95 (-40 to +85C) -- -- -- -- -- -- -- 0.60 1.0 Ta: +255C TEMPERATURE RANGE Operating temperature C -40 to +85 Storage temperature C -40 to +85 * All specifications are subject to change without notice. * Before using these products, be sure to request the delivery specifications. 20190114 / rf_lpf_dea162170lt-5039a5_en.fm RF Components DEA162170LT-5039A5 FREQUENCY CHARACTERISTICS ATTENUATION 0.0 0 0.5 10 1.0 20 Attenuation(dB) Insertion Loss(dB) INSERTION LOSS 1.5 2.0 2.5 3.0 1000 30 40 50 1200 1400 1600 1800 2000 Frequency (MHz) 2200 2400 2600 1400 1600 1800 2000 Frequency (MHz) 2200 2400 2600 60 0 2000 4000 6000 8000 Frequency (MHz) 10000 12000 14000 RETURN LOSS 0 Return Loss(dB) 10 20 30 40 50 1000 1200 * All specifications are subject to change without notice. * Before using these products, be sure to request the delivery specifications. 20190114 / rf_lpf_dea162170lt-5039a5_en.fm RF Components DEA162170LT-5039A5 RECOMMENDED REFLOW PROFILE Preheating Soldering Peak T4 T: Temperature 3C/sec or lower 6C/sec or lower T3 T2 T3 t3 T1 t1 t2 t: Time Preheating Temp. T1 150C T2 200C Time t1 60 to 120sec Soldering Critical zone (T3 to T4) Temp. Time T3 t2 217C 60 to 120sec Peak Temp. T4 240 to 260C Time t3 30sec max. t3 : Time within 5C of actual peak temperature The maximum number of reflow is 3. * All specifications are subject to change without notice. * Before using these products, be sure to request the delivery specifications. 20190114 / rf_lpf_dea162170lt-5039a5_en.fm RF Components REMINDERS FOR USING THESE PRODUCTS Before using these products, be sure to request the delivery specifications. SAFETY REMINDERS Please pay sufficient attention to the warnings for safe designing when using these products. REMINDERS The products listed on this catalog are intended for use in general electronic equipment (AV equipment, telecommunications equipment, home appliances, amusement equipment, computer equipment, personal equipment, office equipment, measurement equipment, industrial robots) under a normal operation and use condition. The products are not designed or warranted to meet the requirements of the applications listed below, whose performance and/or quality require a more stringent level of safety or reliability, or whose failure, malfunction or trouble could cause serious damage to society, person or property. Please understand that we are not responsible for any damage or liability caused by use of the products in any of the applications below or for any other use exceeding the range or conditions set forth in this catalog. (1) Aerospace/Aviation equipment (2) Transportation equipment (cars, electric trains, ships, etc.) (3) Medical equipment (4) Power-generation control equipment (5) Atomic energy-related equipment (6) Seabed equipment (7) Transportation control equipment (8) Public information-processing equipment (9) Military equipment (10) Electric heating apparatus, burning equipment (11) Disaster prevention/crime prevention equipment (12) Safety equipment (13) Other applications that are not considered general-purpose applications When using this product in general-purpose applications, you are kindly requested to take into consideration securing protection circuit/ equipment or providing backup circuits, etc., to ensure higher safety. * All specifications are subject to change without notice. * Before using these products, be sure to request the delivery specifications. 20190114 / rf_lpf_dea162170lt-5039a5_en.fm