Anti-Parallel Parallel
2
1
323
414
SOT-227
2
1
3
4
APT2X100D60J APT2X101D60J
Characteristic / Test Conditions
Maximum D.C. Reverse Voltage
Maximum Peak Repetitive Reverse Voltage
Maximum Working Peak Reverse Voltage
Maximum Average Forward Current (TC = 60°C, Duty Cycle = 0.5)
RMS Forward Current
Non-Repetitive Forward Surge Current (TJ = 45°C, 8.3ms)
Operating and StorageTemperature Range
Lead Temperature: 0.063" from Case for 10 Sec.
Symbol
VR
VRRM
VRWM
IF(AV)
IF(RMS)
IFSM
TJ,TSTG
TL
Symbol
VF
IRM
CT
LS
Characteristic / Test Conditions
IF = 100A
Maximum Forward Voltage IF = 200A
IF = 100A, TJ = 150°C
Maximum Reverse Leakage Current VR = VR Rated
VR = VR Rated, TJ = 125°C
Junction Capacitance, VR = 200V
Series Inductance (Lead to Lead 5mm from Base)
STATIC ELECTRICAL CHARACTERISTICS
UNIT
Volts
Amps
°C
UNIT
Volts
µA
pF
nH
MIN TYP MAX
2.0
1.7
1.7
250
500
165
20
APT2X100/2X101D60J
600
100
170
1000
-55 to 150
300
MAXIMUM RATINGS All Ratings: TC = 25°C unless otherwise specified.
PRODUCT BENEFITS
Low Losses
Low Noise Switching
Cooler Operation
Higher Reliability Systems
Increased System Power
Density
PRODUCT FEATURES
Ultrafast Recovery Times
Soft Recovery Characteristics
Popular SOT-227 Package
Low Forward Voltage
High Blocking Voltage
Low Leakage Current
PRODUCT APPLICATIONS
Anti-Parallel Diode
-Switchmode Power Supply
-Inverters
Free Wheeling Diode
-Motor Controllers
-Converters
Snubber Diode
Uninterruptible Power Supply (UPS)
Induction Heating
High Speed Rectifiers
DUAL DIE ISOTOP® PACKAGE
ULTRAFAST SOFT RECOVERY DUAL RECTIFIER DIODES
053-6007 Rev E
APT2X100D60J 600V 100A
APT2X101D60J 600V 100A
USA
405 S.W. Columbia Street Bend, Oregon 97702-1035 Phone: (541) 382-8028 FAX: (541) 388-0364
EUROPE
Avenue J.F. Kennedy Bât B4 Parc Cadéra Nord F-33700 Merignac - France Phone: (33)5 57 9215 15 FAX: (33) 5 56 47 97 61
APT Website - http://www.advancedpower.com
MIN TYP MAX
60 75
60
92
185
185
27 38
42 54
810
1930
10.2
10.2
600
400
UNIT
ns
Amps
nC
Volts
A/µs
APT2X100/2X101D60J
Characteristic
Reverse Recovery Time, IF = 1.0A, diF/dt = -15A/µs, VR = 30V, TJ = 25°C
Reverse Recovery Time TJ = 25°C
IF = 100A, diF/dt = -800A/µs, VR = 350V TJ = 100°C
Forward Recovery Time TJ = 25°C
IF = 100A, diF/dt = 800A/µs, VR = 350V TJ = 100°C
Reverse Recovery Current TJ = 25°C
IF = 100A, diF/dt = -800A/µs, VR = 350V TJ = 100°C
Recovery Charge TJ = 25°C
IF = 100A, diF/dt = -800A/µs, VR = 350V TJ = 100°C
Forward Recovery Voltage TJ = 25°C
IF = 100A, diF/dt = 800A/µs, VR = 350V TJ = 100°C
Rate of Fall of Recovery Current TJ = 25°C
IF = 100A, diF/dt = -800A/µs, VR = 350V (See Figure 10) TJ = 100°C
10-5 10-4 10-3 10-2 10-1 1.0 10
RECTANGULAR PULSE DURATION (SECONDS)
FIGURE 1, MAXIMUM EFFECTIVE TRANSIENT THERMAL IMPEDANCE, JUNCTION-TO-CASE vs PULSE DURATION
DYNAMIC CHARACTERISTICS
Symbol
trr1
trr2
trr3
tfr1
tfr2
IRRM1
IRRM2
Qrr1
Qrr2
Vfr1
Vfr2
diM/dt
0.5
0.1
0.05
0.01
0.005
0.001
D=0.5
THERMAL AND MECHANICAL CHARACTERISTICS
Characteristic / Test Conditions
Junction-to-Case Thermal Resistance
Junction-to-Ambient Thermal Resistance
RMS Voltage (50-60 Hz Sinusoidal Waveform from Terminals to Mounting Base for 1 Min.)
Package Weight
Maximum Torque (Mounting = 8-32 or 4mm Machine and Terminals = 4mm Machine)
Symbol
RθJC
RθJA
VIsolation
WT
Torque
MIN TYP MAX
0.42
20
2500
1.03
29.2
13.6
1.5
UNIT
°C/W
Volts
oz
gm
lb•in
N•m
ZθJC, THERMAL IMPEDANCE (°C/W)
Note:
Duty Factor D = t1/t2
Peak TJ = PDM x ZθJC + TC
t1
t2
PDM
SINGLE PULSE
0.02
0.05
0.1
0.2
0.01
053-6007 Rev E
VF, ANODE-TO-CATHODE VOLTAGE (VOLTS) diF/dt, CURRENT SLEW RATE (AMPERES/µSEC)
Figure 2, Forward Voltage Drop vs Forward Current Figure 3, Reverse Recovery Charge vs Current Slew Rate
diF/dt, CURRENT SLEW RATE (AMPERES/µSEC) TJ, JUNCTION TEMPERATURE (°C)
Figure 4, Reverse Recovery Current vs Current Slew Rate Figure 5, Dynamic Parameters vs Junction Temperature
diF/dt, CURRENT SLEW RATE (AMPERES/µSEC) diF/dt, CURRENT SLEW RATE (AMPERES/µSEC)
Figure 6, Reverse Recovery Time vs Current Slew Rate Figure 7, Forward Recovery Voltage/Time vs Current Slew Rate
VR, REVERSE VOLTAGE (VOLTS)
Figure 8, Junction Capacitance vs Reverse Voltage
CJ, JUNCTION CAPACITANCE trr, REVERSE RECOVERY TIME IRRM, REVERSE RECOVERY CURRENT IF, FORWARD CURRENT
(pico-FARADS) (nano-SECONDS) (AMPERES) (AMPERES)
tfr, FORWARD RECOVERY TIME Kf, DYNAMIC PARAMETERS Qrr, REVERSE RECOVERY CHARGE
(nano-SECONDS) (NORMALIZED) (nano-COULOMBS)
Vfr, FORWARD RECOVERY VOLTAGE
(VOLTS)
0 0.5 1.0 1.5 2.0 2.5 10 50 100 500 1000
0 200 400 600 800 1000 -50 -25 0 25 50 75 100 125 150
0 200 400 600 800 1000 0 200 400 600 800 1000
0.01 0.05 0.1 0.5 1 5 10 50 100 200
APT2X100/2X101D60J
TJ=100°C
VR=350V
TJ=100°C
VR=350V
TJ=100°C
VR=350V
IF=100A
300
240
180
120
60
0
60
50
40
30
20
10
0
400
300
200
100
0
3000
1000
500
100
TJ = 150°C
TJ = 100°C
TJ = -55°C
TJ = 25°C
50A
200A
100A
IRRM
trr
Qrr
Qrr
trr
053-6007 Rev E
200A
100A
50A
TJ=100°C
VR=350V
50A
200A
100A
4000
3000
2000
1000
0
1.6
1.2
0.8
0.4
0.0
3000
2500
2000
1500
1000
500
0
15
12.5
10
7.5
5
2.5
0
tfr
Vfr
Anode 1
31.5 (1.240)
31.7 (1.248)
Dimensions in Millimeters and (Inches)
7.8 (.307)
8.2 (.322)
30.1 (1.185)
30.3 (1.193)
38.0 (1.496)
38.2 (1.504)
14.9 (.587)
15.1 (.594)
11.8 (.463)
12.2 (.480)
8.9 (.350)
9.6 (.378)
Hex Nut M4 H100
(4 places)
0.75 (.030)
0.85 (.033) 12.6 (.496)
12.8 (.504)
25.2 (0.992)
25.4 (1.000)
1.95 (.077)
2.14 (.084)
Anode 2
Anti-parallel Parallel
Cathode 1
r = 4.0 (.157)
(2 places) 4.0 (.157)
4.2 (.165)
(2 places)
W=4.1 (.161)
W=4.3 (.169)
H=4.8 (.187)
H=4.9 (.193)
(4 places)
3.3 (.129)
3.6 (.143)
Cathode 2 Anode 1
Cathode 2 Anode 2
Cathode 1
APT2X100D60J APT2X101D60J
APT2X100/2X101D60J
053-6007 Rev E
PEARSON 411
CURRENT
TRANSFORMER
0.5 IRRM
di
F
/dt Adjust
30µH
D.U.T.
+15v
-15v
0v
Vr
4
3
1
2
5
5
0.75 IRRM
trr/Qrr
Waveform
Zero
6
1
2
3
4
6
di
F
/dt - Current Slew Rate, Rate of Forward
Current Change Through Zero Crossing.
I
F
- Forward Conduction Current
I
RRM
- Peak Reverse Recovery Current.
trr - Reverse Recovery Time Measured from Point of I
F
Qrr - Area Under the Curve Defined by I
RRM
and trr.
diM/dt - Maximum Rate of Current Change During the Trailing Portion of trr.
Current Falling Through Zero to a Tangent Line
{
diM/dt
}
Extrapolated Through Zero Defined by 0.75 and 0.50 I
RRM
.
6
Figure 9, Diode Reverse Recovery Test Circuit and Waveforms
Figure 10, Diode Reverse Recovery Waveform and Definitions
Qrr = 1/2
(
trr . I
RRM
)
APT Reserves the right to change, without notice, the specifications and information contained herein.
ISOTOP® is a Registered Trademark of SGS Thomson.
SOT-227 Package Outline