SIMATIC NET
Industrial Ethernet
OMC
Operating Instructions
Preface, Contents
Introduction 1
Functions 2
Netw ork Topologies with
OMCs 3
Interfaces and Displays 4
Installation 5
Technical Specifications 6
Further Support 7
Notes on the CE Mark 8
Glossary 9
Index 10
References 11
Release 8 / 2001
C79000-G8976-C164-01
Industri al E thernet OMC
2C79000-G8976-C164-01
Classifi cation of Safety-Related Notices
This document contains notices which you should observe to ensure your own
personal safety, as well as to protect the product and connected equipment. These
notices are highlighted in the manual by a warning triangle and are marked as follows
according to the level of danger:
Danger
indicates that death or severe personal injury will result if proper precautions are not
taken.
!Warning
indicates that death or severe personal injury can result if proper precautions are not
taken.
!Caution
with warning triangle indicates that minor personal injury can result if proper
precautions are not taken.
Caution
without warning triangle indicates that damage to property can result if proper
precautions are not taken.
Notice
indicates that an undesirable result or status can occur if the relevant notice is ignored.
Note
highlights important information on the product, using the product, or part of the
documentation that is of particular importance and that will be of benefit to the user.
Industri al E thernet OMC
C79000-G8976-C164-01 3
Trademarks
SIMATIC, SIMATIC NET and SINEC are registered trademarks of Siemens AG.
Third parties using for their own purposes any other names in this document which
refer to trademarks might infringe upon the rights of the trademark owners.
Safety Instructions Regarding your Product
Before you use the product described here, read the safety instructions below
thoroughly.
Qualif i ed Personnel
Only qualified personnel should be allowed to install and work on this equipment .
Qualified persons are defined as persons who are authorized to commission, to
ground, and to tag circuits, equipment, and systems in accordance with established
safety practices and standards.
Correct Usage of Hardware Products
Please note the following regarding the correct usage of hardware products:
Caution
This device and its components may only be used for the applications described in the
catalog or the technical description, and only in connection with devices or
components from other manufacturers which have been approved or recommended
by Siemens.
This product can only function correctly and safely if it is transported, stored, set up,
and installed correctly, and operated and maintained as recommended.
Before you use the supplied sample programs or programs you have written yourself,
make certain that no injury to persons nor damage to equipment can result in your
plant or process.
EU Directive: Do not start up until you have established that the machine on which y ou
intend to run this component complies with the directive 89/392/EEC.
Industri al E thernet OMC
4C79000-G8976-C164-01
Prior t o St ar tup
Before putting the product into operation, note the following warning:
Caution
Before installation and startup, read the instructions in the appropriate documentation.
For ordering data of the documentation, please refer to catalogs or contact your local
Siemens representative.
Industri al E thernet OMC
5C79000-G8976-C164-01
Preface
Purpose of the Operating Instructions
These Operating Instructions support you when configuring, commissioning, and
troubleshooting networks including the Optical Media Converters OMC TP11 and
OMC TP11-LD.
The Package
The OMC includes the following components:
β€’ OMC device
β€’ 6-pin plug-in terminal block
β€’ Fittings (fixing brackets, screws) for wall mounting or installation in a 19" cabinet
β€’ Product Information
Mounting t he OMC
Follow the instructions in Chapter 5 of these operating instructions.
Validity of the Operating Instructions
These operating instructions are valid for the following devices:
β€’ OMC TP11
β€’ OMC TP11-LD
Preface
Industri al E thernet OMC
6C79000-G8976-C164-01
Further Documentation
The "SIMATIC NET Industrial Ethernet Twisted Pair and Fiber Optic Networks"
manual contains information on other SIMATIC NET products that you can operate
in conjunction with OMCs in an Industrial Ethernet network.
You can download this manual from Customer Support on the Internet under entry
number 1172207:
http://www4.ad.siemens.de/view/cs/de/1172207
Finding Inf ormat i on
To help you to find information quickly, the appendix includes the following sections
in addition to the table of contents:
β€’ Glossary
β€’ Index
Guide to the Manual
To help you to find specific information quickly, these operating instructions include
the following parts:
β€’ At the front of the operating instructions you will find a complete table of
contents.
β€’ The chapters have headings in the left margin with an overview of the contents
of the paragraphs in the section.
β€’ Following the appendix, you will find a Glossary in which the most important
specialist terms used in the instructions are defined.
β€’ At the back of the operating instructions, you will find an index with which you
can find topics quickly.
Audience
These Operating Instructions are intended for persons involved in configuring,
commissioning, and troubleshooting networks including the OMC TP11 and
OMC TP11-LD.
Preface
Industri al E thernet OMC
C79000-G8976-C164-01 7
Personnel Quali f ication Requirements
Only qualified personnel should be allowed to install and work on this equipment.
Qualified personnel as referred to in the operating instructions or in the warning
notes are defined as persons who are familiar with the installation, assembly,
startup and operation of this product and who possess the relevant qualifications for
their work, e.g.:
β€’ Training in or authorization for connecting up, grounding or labeling circuits and
devices or systems in accordance with current standards in safety technology;
β€’ Training in or authorization for the maintenance and use of suitable safety
equipment in accordance with current standards in safety technology;
β€’ First Aid qualification.
Standards and Approvals
The OMC meets the requirements for the CE mark. For more detailed information
about approvals and standards, refer to the appendix.
Industri al E thernet OMC
8C79000-G8976-C164-01
Contents
1 Introduction .....................................................................................................................9
1.1 OMC TP11..........................................................................................................10
1.2 OMC TP11-LD....................................................................................................12
2 Functions .......................................................................................................................13
3 Network Topologies with OMCs..................................................................................14
4 Interfaces and Displays ................................................................................................18
4.1 TP Port ...............................................................................................................19
4.2 FO Port...............................................................................................................21
4.3 Signaling Contact and Power Supply .................................................................22
4.4 Displays..............................................................................................................24
5 Installation and Maintenance.......................................................................................25
5.1 Components of the Product................................................................................26
5.2 Installation...........................................................................................................27
5.3 Cleaning..............................................................................................................32
5.4 Maintenance.......................................................................................................33
6 Technical Specifications ..............................................................................................34
7 Further Support.............................................................................................................37
8 Notes on the CE Mark...................................................................................................41
9 Glossary.........................................................................................................................43
10 Index ............................................................................................................................44
11 References.....................................................................................................................45
Industri al E thernet OMC
9C79000-G8976-C164-01
Introduction 1
The OSM/ESM V2 (/5/) product generation allows you to structure powerful Fast
Ethernet networks in an industrial environment. However, nodes can only be
attached to the network over twisted-pair ports; in other words electrically.
To remove this restriction, the OSM/ESM product range has been expanded with
the addition of the OMC TP11 and OMC TP11-LD media converters. The OMCs
open up new areas of application, such as:
β€’ FO right up to the machine:
Fast FO node attachment (100 Mbps full duplex) over FO ports of the OSMs
and media converters in areas with high levels of electromagnetic interference.
β€’ Spanning of long distances (LD, long-distance):
FO cable sections up to 26 km to a single remote station.
Introduction
Industri al E thernet OMC
10 C79000-G8976-C164-01
1.1 OMC TP11
Possible Attachments
β€’ A network component, such as an ESM electrical switch module or a DTE over
the twisted-pair port (RJ-45 socket)
β€’ A network component, such as an OSM optical switch module or a DTE over a
second OMC at the optical port (2 BFOC sockets)
Figure 1: OMC TP11
Introduction
Industri al E thernet OMC
C79000-G8976-C164-01 11
Properties of the OMC TP11
Electrical port 100 Mbps (full duplex)
TP connector technology (RJ-45 socket
with MDI-X Pinning (Medium
Dependent Interface-Cross Over))
Max. cable length 6 m (TP Cord or TP
XP Cord)
Optical port 100 Mbps FO ports (full duplex)
BFOC female connectors
Maximum distance between two OMC
TP11 modules
or to an OSM ITP62-LD
3000 m (multimode graded-index fiber)
Introduction
Industri al E thernet OMC
12 C79000-G8976-C164-01
1.2 OMC TP11-LD
Possible Attachments
The OMC TP11-LD is suitable for spanning extremely long distances. With the
monomode fiber, distances up to 26 km between two OMC TP11-LD or between an
OMC TP11-LD and OSM ITP62-LD can be spanned.
Properties of the OMC TP11-LD
Electrical port 100 Mbps (full duplex)
TP attachment technology (RJ-45
socket wi th MDI-X Pinning (Medium
Dependent Interface-Cross Over))
Max. cable length 6 m (TP Cord or TP
XP Cord)
Optical port 100 Mbps FO ports (full duplex)
BFOC female connectors
Maximum distance between two
OMC TP11-LD 26 km (monomode fiber)
Note
The OMC TP11-LD can only be linked with the OMC TP11-LD or OSM ITP62-LD
over its optical port.
Linking the optical port w ith an OMC TP11, OSM ITP62, OSM ITP53 or OSM TP62
is not permitted.
Industri al E thernet OMC
13 C79000-G8976-C164-01
Functions 2
Converting between 100BaseTX and 100BaseFX
The OMC is used to link standard 100BaseTX Ethernet over twisted-pair (TP) cable
and 100BaseFX Ethernet over FO cable. All data is forwarded transparently from
the optical port to the electrical port and vice versa.
Notice
The devices attached to OMCs must support 100 Mbps and full duplex.
Setting t he Transmissi on Rate or Duplex Mode
β€’ An OMC is connected optically to an OSM FO port:
In this configuration, if the device connected to the TP interface of the OMC is
capable of autonegotiation and the full duplex mode, the device is configured
automatically for 100 Mbps and full duplex. Using components of the OSM
family and devices capable of autonegotiation and full duplex makes a plug-and-
play configuration possible.
β€’ Two OMCs are interconnected over an FO cable:
If two devices with activated autonegotiation are connected to the two OMCs,
the autonegotiation procedure taking place at both ends at the same time may
prevent a link from being established. To prevent this, one or both of the TP
devices must be permanently set to 100 Mbps and full duplex.
Link Fault Transfer
The link status of the FO link is transferred to the TP port and vice versa.
This means that the OMC can also be used in redundant rings or in standby
sections for the redundant linking of subnets.
Industri al E thernet OMC
14 C79000-G8976-C164-01
Network Topologies with OMCs 3
Using the media converters OMC TP11 and OMC TP11-LD, the following
applications can be implemented.
Attachment of Individual Remotely Located DTEs over OMC-FOC-OM C t o a
Twisted-Pair Netw ork
1
00 Mb ps
T
P XP Cord
m
ax. 6 m
O
MC
1
00 Mb ps
f
iber-optic
m
ax. 3 km / 26 km
1
00 Mbps
T
P Cord
m
ax. 6 m
O
MC
E
SM
ESM
S7-400
S7-300
10/100 Mbps
max. 100 m
P
C
Notice
Since two OMCs are connected over FO cable, one of the two TP devices (in the
figure: S7-400 CP or ESM port to the OMC) must be permanently set to 100 Mbps
and full duplex.
Network Topologies with OMCs
Industri al E thernet OMC
C79000-G8976-C164-01 15
Attachment of Remot e l y Located Subnets over OSM-FOC- O M C t o a Twisted-Pair
Network
10/100 Mbps
max. 100 m
E
SM
OSM
OMC
S
7-400 S7-300
E
SM
PC
1
00 Mbps
T
P XP Cord
m
ax. 6 m
100 Mbps
fiber-optic
max. 3 km / 26 km
1
0/100 M bps
m
ax. 100 m
The ESM port to the OMC sets itself automatically to 100 Mbps and full duplex.
Manual setting of the ESM port to the OMC is not necessary.
Network Topologies with OMCs
Industri al E thernet OMC
16 C79000-G8976-C164-01
Including FO Cable Sections in a Twi sted-Pair Network, for Example in an ESM
Ring
00 Mbps
iber-optic
ax. 3 km / 26 km
10/100 Mbps
max. 100 m
E
SM
E
SM
E
SM
OMCOMC PC
Notice
To keep to the specified failover times in a redundant configuration, both TP
devices connected to the OMCs must be permanently set to 100 Mbps and full
duplex.
Network Topologies with OMCs
Industri al E thernet OMC
C79000-G8976-C164-01 17
Redundant Linking of OSM/ESM Subnets Located a Long Distance Apart over
OMC TP11 or OMC TP11-LD
OMC
TP11-LD
O
MC
T
P11-LD
S
tby cable
OSM/ESM ring 1
O
MC
T
P11-LD
OMC
TP11-LD
OSM/ESM ring 2
O
SM/ESM in
S
tby mode
F
iber-optic
1
00 Mbps
m
ax. 26 km
Notice
To keep to the specified failover times in a redundant configuration, all TP devices
connected to the OMCs must be permanently set to 100 Mbps and full duplex.
Industri al E thernet OMC
18 C79000-G8976-C164-01
Interfaces and Displays 4
Interfaces and Displays
Industri al E thernet OMC
C79000-G8976-C164-01 19
4.1 TP Port
Pinning
On the OMC, the TP port is implemented as an RJ-45 with MDI-X Pinning (Medium
Dependent Interface-Cross Over) socket.
Notice
TP Cords or TP-XP Cords with a maximum length of 6 m can be connected to the
TP port. Other attachments (connections via outlets, longer TP Cords) are not
permitted.
Link Control
The attached cable segments are monitored according to the 100BASETX
standard for short circuits or w ire breaks. A fault on the link is signaled by the port
status displays of the OMC and of the devices connected to the TP and FO ports.
Duplex Mode
The OMC is capable of full duplex mode; in other words data can be transferred in
both directions at the same time. The optical interfaces of the OMC also operate in
full duplex mode so that TP devices connected to these ports must also be set to
this mode.
Note
Both devices connected to the OMC (FO and TP ) must be set to full duplex mode.
If the devices do not support autonegotiation, full duplex mode must be configured
manually.
Autonegotiation
Using the autonegotiation mechanism according to the IEEE standard 802.3, a TP
device capable of autonegotiation and full duplex is automatically set to 100 Mbps
and full duplex.
Interfaces and Displays
Industri al E thernet OMC
20 C79000-G8976-C164-01
Note
β€’ It is not possible to link two OMCs over their TP interfaces.
β€’ The OMC can be used along with products of the OSM/ESM family in
redundant rings or in standby links (see Network Topologies OMC, Part 3). To
keep to the specified failover times in a redundant configuration, both TP
devices connected to the OMCs must be permanently set to 100 Mbps and full
duplex.
β€’ If two OMCs are interconnected over an FO cable and if two devices with
activated autonegotiation are connected over their TP ports, the
autonegotiation procedure taking place at both ends at the same time may
prevent a link from being established. To prevent this, one or both of the TP
devices must be permanently set to 100 Mbps and full duplex.
Interfaces and Displays
Industri al E thernet OMC
C79000-G8976-C164-01 21
4.2 FO Port
The FO port has a BFOC/2.5(ST) female connector. The connected cable is
monitored for wire breaks complying wi th the IEEE 802.3 100BaseFX standard. A
break on the FO cable is always signaled by the port status displays of the OMC
and of the two attached devices. (Status LED of the port goes off).
Interfaces and Displays
Industri al E thernet OMC
22 C79000-G8976-C164-01
4.3 Signali ng Contact and Power Supply
The attachment of the power supply and the signaling contact is made using a 6-pin
plug-in terminal block with a screw securing mechanism.
L1 +
F1
M
M
F2
L2 +
+
24V DC
+
24V DC
Figure 2: Terminal Block
!Warning
Industrial Ethernet OMCs are designed for operation with safety extra-low voltage.
This means that only safety extra-low voltages (SELV) complying with
IEC950/EN60950/ VDE0805 can be connected to the power supply terminals and
the signaling contact.
The power supply unit to supply the OMC must comply with NEC Class 2 (voltage
range 18 - 32 V, current requirement 1 A)
The signaling contact can carry a load of maximum 100 mA (safety extra-low
voltage (SELV), DC 24V).
Interfaces and Displays
Industri al E thernet OMC
C79000-G8976-C164-01 23
Power Supply
The power supply can be connected redundantly. Both inputs are isolated. There is
no load distribution. With redundant power supply, the power supply unit with the
higher output voltage supplies the OMC alone. The power supply is connected over
a high resistance with the enclosure to all an ungrounded setup.
Signaling Contact
The following is signaled via a floating signaling contact (relay contact) when
contact is broken:
β€’ The failure of one or both power supplies.
Notice
Both power supplies are always monitored (L1 and L2). If only one power supply
exists, this must be applied via L1 and L2 otherwise the signaling contact will
signal an error.
β€’ The incorrect link status of a port (in other words, the port is not correctly
attached or there are no link test pulses coming from the partner device).
Interfaces and Displays
Industri al E thernet OMC
24 C79000-G8976-C164-01
4.4 Displays
Fault display (red LED)
Status Meaning
On The OMC has detected an error. The signaling contact opens
at the same time. The signaled errors are described in
Chapter 4.3.
Off No errors detected by the OMC.
Power display (green LEDs)
The status of the redundant power supply is signaled by two green LEDs:
Status Meaning
On Power supply L1 or L2 is connected
Off Power supply L1 or L2 is not connected or <14 V
Port status display (green/yellow LEDs)
The status of the ports is signaled by two LEDs:
Status Meaning
Port 1 LED green TP link exists, no data reception
Port 1 LED yellow TP link exists, receiving data at TP port
Port 1 LED off No TP link exists
Port 2 LED green FO link exists, no data reception
Port 2 LED yellow FO link exists, receiving data at FO port
Port 2 LED off No FO link exists
Industri al E thernet OMC
25 C79000-G8976-C164-01
Installation and Maintenance 5
Installation and Maintenance
Industri al E thernet OMC
26 C79000-G8976-C164-01
5.1 Components of the Product
Unpacking, Checking t he Consignment
1. Check that the consignment includes the following components:
– OMC device
– Mounting brackets, screws and terminal block
– Product Information
2. Check each component for any damage.
!Warning
Do not install damaged components!
Installation and Maintenance
Industri al E thernet OMC
C79000-G8976-C164-01 27
5.2 Installation
There are several ways of installing the OMC:
β€’ Installation on a 35 mm standard rail
β€’ Installation on a SIMATIC S7-300 rail
β€’ Installation in a 19" cabinet (along with other OMCs and OSMs/ESMs)
β€’ Wall mounted
Note
β€’ Remember that the OMC must only be installed horizontally (ventilation slits
top/bottom see Figure 4). To ensure adequate convection, there must be a
clearance of at least 5 cm above and below the ventilation slits. You should
also make sure that the permitted ambient temperature range is not exceeded.
β€’ The optical transmitter and receiver elements are sensitive to contamination.
You should therefore only remove the dust protection caps from the BFOC
sockets immediately before plugging in the FO connector.
If you remove the connector, cover the sockets immediately with the dust
protection caps.
β€’ During installation and operation, make sure that you adhere to the installation
instructions and safety-related notices in this description and in the SIMATIC
NET Industrial Twisted Pair and Fiber-Optic Networks manual /2/.
Preparations
Remove the terminal block from the OMC and w ire up the power supply and signal
lines as described in Section 4.3.
Installation and Maintenance
Industri al E thernet OMC
28 C79000-G8976-C164-01
Standard Rail M ounting
1. Install the OMC on a 35 mm standard rail complying with DIN EN 50022.
2. Fit the OMC on to the rail from above and press in the bottom of the device
until the catch engages.
3. Connect the electrical and optical cables and the terminal block for the power
supply.
Figure 3: Installing the OMC on a DIN Standard Rail
Installation and Maintenance
Industri al E thernet OMC
C79000-G8976-C164-01 29
Removing from a Standard Rail
To remove the OMC from the rail, first disconnect the FO and TP cables and pull
off the terminal block.
Then pull down the device and release it from the rail.
Figure 4. Removing from the Standard Rail
Installation and Maintenance
Industri al E thernet OMC
30 C79000-G8976-C164-01
Installation on a SIMATIC S7-300 Rail
1. First fi x one of the two supplied brackets to the right (OMC mounted on the
right) or the left (OMC mounted on the left) side of the OMC.
2. Fit the guide on the top of the OMC casing into the S7 rail.
3. Screw the OMC to the bottom of the standard rail.
Install ation in a 19" Cubicle
To install in the 19" cubicle, you require the two securing brackets supplied. You
can achieve the 19'' width
β€’ with eight OMCs
β€’ with one OSM / ESM and four OMCs
Follow the steps outlined below:
1. First screw the OMCs or ESMs/OSMs to the supplied mounting plates at the
rear.
2. Fit two of the supplied brackets to the sides
3. Secure the devices using the brackets in the 19" cubicle. Please note that the
OMC must be grounded with low resistance via the two holding brackets.
Note
To install in a 19'' cubicle, you require a Torx screwdriver size T10 x 80.
Installation and Maintenance
Industri al E thernet OMC
C79000-G8976-C164-01 31
Wall Mount i ng
To install an OMC on a wall, follow the steps below:
1. Fit the supplied mounting brackets on the sides of the OMC.
2. Secure the device to the wall using the brackets.
3. Connect the device to protective earth with a low-resistance connection via
one of the brackets.
The table below shows how to secure the module depending on the wall type.
Wall Type Mounting
Concrete wall Use four wall plugs 6 mm in diameter 30 mm long
(drillhole 6 mm diameter, 45 mm deep).
Use screws 4.5 mm in diameter and 40 mm long.
Metal wall
(min. 2 mm thick) Use screws 4 mm in diameter and at least 15 mm
long.
Sandwich type plaster wall
(min. 15 mm thick) Use an anchoring plug with at least
4 mm diameter.
Note
The module must be secured to the wall so that the mounting can carry at least
four times the weight of the module.
Installation and Maintenance
Industri al E thernet OMC
32 C79000-G8976-C164-01
5.3 Cleaning
The OMC casing can be cleaned, when necessary with a dry cloth.
Installation and Maintenance
Industri al E thernet OMC
C79000-G8976-C164-01 33
5.4 Maintenance
If a fault develops, please send the module to your SIEMENS service department
for repair. The devices cannot be repaired on site.
Industri al E thernet OMC
34 C79000-G8976-C164-01
Technical Specifications 6
Attachments
Attachment of DTEs or Network
Components over Twisted Pair 1 x RJ-45 with MDI-X Pinning (Medium
Dependent Interface-Cross Over) on
OMC TP11 and OMC TP11-LD
The ports operate at 100 Mbps, full
duplex (100BaseTX)
Attachment of other network
components or OMCs over FO cable 2 BFOC sockets on the OMC TP11
and OMC TP11-LD
(100 Mbps, full duplex complying with
100BaseFX)
Connector for power supply and
signaling contact 1 x 6-pin plug-in terminal block
Electrical Data
Power supply
(redundant inputs isolated) 2 supplies DC 24 V
(DC 18 to 32 V)
safety extra-low voltage (SELV)
Power loss at DC 24 V 3.6 W
Load on the signaling contact DC 24 V / max. 1000 mA safety extra-
low voltage (SELV)
Current consumption at rated voltage 150 mA
Overcurrent protection at input PTC resettable fuse (0.6 A / 60 V)
Technical Specifications
Industri al E thernet OMC
C79000-G8976-C164-01 35
Permitted Cable Lengths
FO link between two OMCs OMC TP11:
0-3000m (62.5/125 Β΅m or 50/125Β΅m
glass fiber; 1 dB/km at 1300 nm; 600
MHz*km; 6 dB max. permitted FO
cable attenuation at 3 dB link power
margin)
OMC TP11-LD:
0-26000m (10/125 Β΅m monomode
fiber; 0.5 dB/km at 1300 nm; 13 dB
max. permitted FO cable attenuation at
2 dB
TP Connection 0-6 m with TP cord
Permitted Ambient Conditions/EMC
Operating temperature 0Β°C to +60Β°C
Storage/transport temperature -40Β°C to +80Β°C
Relative humidity in operation β€Ή 95% (no condensation)
Operating altitude Max. 2000 m
Noise emission EN 55081 Class A
Noise immunity EN 50082-2
Degree of protection IP 20
Laser protection Class 1 complying with IEC 60825 –1
Technical Specifications
Industri al E thernet OMC
36 C79000-G8976-C164-01
Mechanical Design
Dimensions (W x H x D) in mm 54 x 136.5 x 69
Weight in g 500
Installation options Standard rail
S7-300 rail
Wall mounted
Installation in 19” cubicle
Only horizontal installation
permitted
(ventilation slits top/bottom)
Product a nd Ordering Data
OMC TP11 and OMC TP11-LD β€’ OMC device
β€’ Mounting brackets, screws and
terminal block
β€’ Product Information
Order numbe rs:
OMC TP11 6GK1100-2AB00
OMC TP11-LD 6GK1100-2AC00
β€œIndustrial Twisted Pair and Fiber Optic
Networks” Manual 6GK1970-1BA10-0AA1
Industri al E thernet OMC
37 C79000-G8976-C164-01
Further Support 7
Who to Contact
If you have technical questions about using the described product and your problem
is not dealt with in the documentation or in the integrated help system, please
contact your Siemens representative or dealer.
You will find the addresses:
β€’ in our catalog IK PI
β€’ on the Web (http://www.ad.siemens.de/net)
Further Support
Industri al E thernet OMC
38 C79000-G8976-C164-01
Automati on and Dri ves, Service & Support
Service & Support from A&D is available round the clock worldwide.
The languages spoken are German and English.
French, Italian, and Spanish are also spoken on the authorization hotline.
Technical Support Authorization Hotline
Europe and Africa (Nuremberg)
Mo. To Fr. 7:00 to 17:00 (local time, GMT +1)
Phone: +49 – (0) 180 – 5050 – 222
Fax: +49 – (0) 180 – 5050 – 223
E-mail: techsupport@ad.siemens.de
Europe and Africa (Nuremberg)
Mo. To Fr. 7:00 to 17:00 (local time, GMT +1)
Phone: +49 – (0) 911 – 895 – 7200
Fax: +49 – (0) 911 – 895 – 7201
E-mail: authorization@nbgm.siemens.de
America (Johnson City)
Mo. To Fr. 8:00 to 19:00 (local time, GMT –5)
Phone: +1 – (0) 423 – 262 – 2522
Fax: +1 – (0) 423 – 262 – 2231
E-mail: simatic.hotline@sea.siemens.com
Asia and Australia (Singapore)
Mo. To Fr. 8:30 to 17:30 (local time, GMT +8)
Phone: +65 – (0) 740 – 7000
Fax: +65 – (0) 740 – 7001
E-mail: simatic.hotline@sae.siemens.com.sg
SIMATIC Premium Hotline
Worldwide (Nuremberg)
Workdays
0:00 to 24:00 (local time, GMT +1)
Phone: +49 – (0) 911 – 895 – 7777
Fax: +49 – (0) 911 – 895 – 7001
E-mail: techsupport@ad.siemens.de
Fast callback
guaranteed within a maximum of two hours
(charged, only with the SIMATIC Card)
Johnson City Nuremberg
SingaporeSingapore
Service & Support
Further Support
Industri al E thernet OMC
C79000-G8976-C164-01 39
Service & Support on the Internet
On the World Wide Web, you will find the very latest information on the entire
SIMATIC product range, for example, answers to frequently asked questions
(FAQs), Tips and Tricks, software updates, and user information.
In addition to this free information, you can also order the following, for which a
charge is made:
β€’ Software products
β€’ Sample application programs
These are charged to the SIMATIC CARD.
Internet address:
http://www.siemens.de/automation/service&support
You can also formulate a question for the SIMATIC Knowledge Manager that will
find the solution in the knowledge database.
If you are working in an area without an online connection, part of the free
information area is available on the β€œSIMATIC Customer Support Knowledge Base”
CD.
Further Support
Industri al E thernet OMC
40 C79000-G8976-C164-01
Training for SIMATIC NET
Who to Contact about Training Courses:
Siemens AG
Trainings-Center fΓΌr Automatisierungs- und Antriebstechnik
A&D PT 49 KursbΓΌro
Γ–stliche RheinbrΓΌckenstraße 50
76181 Karlsruhe
Germany
Phone: +49 – (0) 721 – 595 – 2917
Fax: +49 – (0) 721 – 595 – 6087
Internet: http://www.sitrain
Certification
The products of SIMATIC NET are manufactured and marketed using a quality
management system complying with DIN ISO 9001 and certified by DQS (certificate
registration no. 2613). The DQS certificate is recognized in all IQNet countries
(Reg. No. 2613).
Industri al E thernet OMC
41 C79000-G8976-C164-01
Notes on the CE Mark 8
Product name:
SIMATIC NET OMC TP11 6GK1100-2AB00
OMC TP11-LD 6GK1100-2AC00
The SIMATIC NET products listed above meet the requirements of the follow ing EU
directives:
EMC Directive
Directive 89/336/EEC β€œElectromagnetic Compatibility”
Area of Application
The products are designed for use in an industrial environment:
Requirements
Area of Application
Noise emission Noise immunity
Industry EN 50081-2 : 1993 EN 50082-2 : 1995
Installation Guidelines
β€’ The products meet the requirements if you adhere to the installation and safety
instructions contained in this description and in the β€œSIMATIC NET Industrial
Ethernet TP and Fiber-Optic Networks” manual.
Notes on the CE Mark
Industri al E thernet OMC
42 C79000-G8976-C164-01
Conformity Certificates
The EU declaration of conformity is available for the responsible authorities
according to the above-mentioned EU directive at the following address:
Siemens Aktiengesellschaft
Bereich Automatisierungs- und Antriebstechnik
Industrielle Kommunikation (A&D PT2)
Postfach 4848
D-90327 NΓΌrnberg
Germany
Notes for the Manufacturers of Machines
This product is not a machine in the sense of the EU directive on machines. There
is therefore no declaration of conformity for the EU directive on machines
89/392/EEC.
If the product is part of the equipment of a machine, it must be included in the
procedure for obtaining the declaration of conformity by the manufacture of the
machine.
Industri al E thernet OMC
43 C79000-G8976-C164-01
Glossary 9
Autonegotiation Procedure standardized by IEEE 802.3 in which the transmission
parameters (for example 10/100 Mbps, full/half duplex) are negotiated
automatically between the devices.
Autosensing See Autonegotiation
BFOC Bayonet Fiber-Optic Connector (ST-compatible).
EMC Electromagnetic compatibility
ESM Electrical Switching Module. SIMATIC NET Ethernet switch with
electrical ports
FOC Fiber-optic cable
LD Long Distance
MDI-X MDI-X Pinning (Medium Dependent Interface-Cross Over)
OMC Optical Media Converter
OSM Optical Switching Module. SIMATIC NET Ethernet switch with optical
and electrical ports
Signaling contact Floating relay contact via which the error states detected by the OMC
can be signaled.
TP Port Twisted-pair port
Industri al E thernet OMC
44 C79000-G8976-C164-01
Index 10
A
Ambient conditions, permitted..................35
Attachments.............................................34
Authorization hotline.................................38
C
Cable lengths, permitted..........................35
Customer Support....................................38
D
Design, mechanical..................................36
Displays..............................................18, 24
E
Electrical data...........................................34
F
FO ports ...................................................21
I
Installation in cubicle Schrank..................30
Installation, S7-300 rail.............................30
Interfaces .................................................18
L
Link control...............................................19
M
Mounting, standard rail............................28
N
Network Topologies.................................14
O
OMC TP11...............................................10
OMC TP11-LD.........................................12
P
Power supply...........................................23
Product and ordering data.......................36
S
Signaling contact .....................................23
T
Technical specifications...........................34
Technical Support....................................38
TP port.....................................................19
W
Wall mounting..........................................31
Industri al E thernet OMC
45 C79000-G8976-C164-01
References 11
/1/ SIMATIC NET Industrial Ethernet OSM/ESM Network Management,
Release 08/2001
Available at
http://www4.ad.siemens.de/view/cs/de/8677203
on the Web.
/2/ SIMATIC NET Industrial Twisted Pair and Fiber-Optic Networks, Release 05/2001
Order numbers:
6GK1970-1BA10-0AA0 German
6GK1970-1BA10-0AA1 English
6GK1970-1BA10-0AA2 French
6GK1970-1BA10-0AA4 Italian
/3/ SINEC H1 Manual for Triaxial Networtks, Release 04
Order number 6GK1970-1AA20-0AA0 (German/English)