Power Relay G5PA-1 New G5P-series Power Relay is Ideal for Power Supplies of TV Sets and Audio Systems Switches an inrush current of 78 A and a constant current of 5 A, thus meeting TV-5 requirements for TV and audio system use. Highly sensitive with a coil power consumption of 250 mW. Ensures a long service life of 40,000 operations when switching an inrush current of 100 A. Incorporates environment-friendly contacts without cadmium. RCSE Equipped with a package of double-insulation construction ensuring high insulation performance. Models conforming to UL508, CSA C22.2, VDE0435/IEC255, and SEMKO are available. Ordering Information Classification Standard Note: Contact form SPST-NO Enclosure ratings Flux protection Model G5PA-1-8 When ordering, add the rated coil voltage to the model number. Example: G5PA-1-8 12 VDC Rated coil voltage Model Number Legend G5PA-1-8 j VDC 1 2 3 1. Number of Poles 1: 1 pole (SPST-NO) 2. Coil Terminal Width 8: 0.8 mm 3. Rated Coil Voltage 12, 24 VDC Specifications Coil Ratings Rated voltage 12 VDC 24 VDC Rated current 20.8 mA 10.4 mA Coil resistance 576 ! 2,304 ! Must operate voltage 80% of rated voltage max. Must release voltage 10% of rated voltage min. Max. permissible voltage 110% of rated voltage Power consumption Approx. 250 mW Note: 1. Each rated current or coil resistance value must allow a tolerance of "10% at a coil temperature of 23#C. 2. The operating characteristics are values at a coil temperature of 23#C. 3. The maximum permissible voltage is the maximum voltage that is applicable to the relay coil for an instant. 1 G5PA-1 G5PA-1 Contact Ratings Rated load (capacitive load) 125 VAC with inrush current of 100 A (0 to peak) and constant current of 3 A (rms) Resistive load (reference value) 5 A, 250 VAC; 5A, 30 VDC Max. switching voltage 250 VAC, 30 VDC Max. switching current 5A Characteristics Contact resistance (see note 2) 100 m! max. Operate time 15 ms max. Release time 5 ms max. Insulation resistance (see note 3) 1,000 M! min. (at 500 VDC) Dielectric strength 4,000 VAC 50/60 Hz for 1 min between coil and contacts 1,000 VAC 50/60 Hz for 1 min between contacts of same polarity Impulse withstand voltage 10,000 V (1.2 x 50 $s) between coil and contacts Vibration resistance Destruction: 10 to 55 Hz, 1.5-mm double amplitude Malfunction: 10 to 55 Hz, 1.5-mm double amplitude Shock resistance Destruction: 1,000 m/s2 Malfunction: 200 m/s2 Life expectancy Mechanical: 1,000,000 operations min. (at 18,000 operations an hour) Electrical: 40,000 operations min. with a rated load at a 1,800 operations an hour. 80,000 operations min. with a resistive load (reference value) Ambient temperature Operating: --40#C to 70#C (with no icing) Ambient humidity Operating: 35% to 85% Weight Approx. 10 g Note: 1. The data shown above are initial values. 2. The contact resistance is possible with 1 A applied at 5 VDC using a fall-of-potential method. 3. The insulation resistance was measured at 500 VDC. There was no difference in measurement position between this item and the dielectric strength item. Approved Standards UL (File No. E41515, UL508) CSA (File No. LR31928, C22.2 No. 14) Model G5PA-1 Coil ratings 5 to 24 VDC Contact ratings TUV (Certificate No. R9650435, IEC255/VDE0435) Model Number of test operations 5 A, 277 VAC 30,000 5 A, 30 VDC 6,000 TV-5 rating 25,000 SEMKO (Certificate No. 9732043; EN60065) Model Coil ratings G5PA-1 5 to 28 VDC 2 Contact ratings 5 A/40 A, 250 VAC 3 A/100 A, 250 VAC Number of test operations 10,000 G5PA-1 Coil ratings 5 to 24 VDC Contact ratings 5 A, 250 VAC (cos% & '( 5 A, 30 VDC (L/R : 0 ms) Number of test operations 100,000 G5PA-1 G5PA-1 Engineering Data G5PA-1 DC resistance load Ambient Temperatures vs. Maximum Coil Voltage Maximum coil voltage (%) Switching current (A) Maximum Switching Power G5PA-1 AC resistance load 150 Ambient temperature (#C) Switching voltage (V) Note: The maximum coil voltage refers to the maximum value in a varying range of operating power voltage, not a continuous voltage. Dimensions Note: All units are in millimeters unless otherwise indicated. 10 max. (9.85)* 24 max. (23.85)* Mounting Holes (Bottom View) Tolerance: "0.1 mm. Two, 1.0-dia. holes Terminal Arrangement /Internal Connections (Bottom View) Two, 1.3-dia. holes 25 max. (24.85)* No coil polarity *Average value ALL DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527. Cat. No. J113-E1-2A 3