Microwave/Counter/Analyzer & Integrated Power Meter MCA3000 Series Data Sheet Available Functions and Features Automated Measurements: Frequency, Period, Ratio, Time Interval, Time Interval Error, Pulse Width, Rise/Fall Time, Phase Angle, Duty Cycle, Maximum Voltage, Minimum Voltage, Peak-to-Peak Voltage Integrated Power Meter Multi-parameter Display Trend Plot Mode Measurement Statistics Mode Features & Benefits Key Performance Specifications 27 GHz and 40 GHz Models Microwave Analyzer Channel with CW or Burst Two 300 MHz General-purpose Channels -35 dBm to +10 dBm Power Range 100 ps Single-shot Time Resolution 12 Digit/s Frequency Resolution, 14 Digit Display 25 ms (Auto) or Zero (Manual) Acquisition Time 3 mV Voltage Resolution Optional 1.5x10-8 Ultra High-stability Oven Time Base Measurement Throughput 250k Sample/s Data Transfer Rate to Internal Memory (Up to 750k samples stored) 5k Sample/s Data Transfer Rate over USB/GPIB Bus (Block mode) Histogram Mode Allan Deviation Zero Dead-time Frequency/Period Measurements Connectivity USB Device and GPIB Ports on Rear Panel for Quick PC Connectivity GPIB Interface Supports Full SCPI-compatible Programmability and offers an Emulation Mode for Plug-and-Play Replacement in Existing ATE Systems External Arming Input 10 MHz Reference Oscillator Output Includes National Instrument's LabVIEW SignalExpressTM TE Limited Edition Software for Connecting Your Bench Optional TimeViewTM Software Available for Modulation Domain Analysis 3-year Warranty Data Sheet Feature-rich Tools for Precision Measurements The MCA3000 Microwave Counter Series outperforms every microwave counter on the market today in terms of resolution, speed, and acquisition time. Including an integrated power meter, the MCA Series packs many different functions into one feature-rich instrument. With industry-leading frequency and time resolution, the MCA Series comes standard with internal memory and a fast data transfer rate of 250k Samples/s to memory. In addition, the multi-parameter display shows auxiliary measurements alongside your main measurement to provide you with the results you need at a glance. With the industry's most comprehensive analysis modes, including measurement statistics, histograms, and trend plots, you have the tools you need to quickly and accurately analyze your signal. Besides being an outstanding microwave counter, the MCA3000 Series also serves as a general-purpose timer/counter with two additional 300 MHz inputs. Industry-leading Performance for Demanding Designs Fast high-resolution frequency or power measurements with a very short acquisition time of 25 ms (Auto) or zero (Manual) is essential for validating today's complex designs. For calibration and metrology applications, the MCA Series offers very high accuracy through a stable internal OCXO time base, low systematic time interval A-B error, and high resolution. Fast Throughput Reduces Test Time The MCA Microwave Counter Series offers industry-best throughput, saving you up to 90% on your testing time compared to other microwave timer/counters on the market. Up to 250,000 measurement results per second can be stored in the internal memory. Alternatively, you can transfer up to 5,000 measurement results per second in Block mode through the GPIB or USB interface. Power Measurements With an integrated power meter, the MCA Series provides measurement of frequency and power with a single connection at any supported frequency 2 www.tektronix.com Multi-parameter Display. level. For the first time, variations in signal power can be seen, collected, and analyzed in the same manner as frequency, both numerically and graphically. With 0.01 dBm at 100 ms measuring time resolution and a wide power range from -35 dBm to +10 dBm, you have the flexibility for a broad range of power measurement applications. Analyze Your Device with the Industry's Only Graphical Display With the unique display of the MCA Series, you can measure multiple parameters of the same signal from one test connection. To reveal signal quality issues like drift, intermittent transients, and stability, you can view the data as a real-time trend plot or a histogram with the MCA Series graphical display mode, or you can use measurement statistics to track how signal parameters are changing over time. A single-button Analyze mode gives you fast insight into the behavior of your device right on the timer/counter's display. Multi-parameter Display With the multi-parameter display, you can read important auxiliary measurement values (such as Vmax, Vmin, Vp-p, and more) displayed with your main frequency, time, period, or phase measurements. With one glance, you can see the information you need to quickly assess your device's performance. With 3 input channels, you can measure the relationship between different signals. For example, you can measure the phase relationship between the input and output signals of your device. You can read other critical parameters simultaneously, such as the test frequency of the signal and the voltage ratio (in dB), in one glance with the multi-parameter display. Microwave/Counter/Analyzer & Integrated Power Meter -- MCA3000 Series Trend Plot Analysis. Tektronix TimeViewTM Software. Measurement Statistics. Histogram Plot. Measurement Trend Plots Depending on your test case, your signal parameters may change from instant to instant. With the Trend Plot Analysis mode, you can graphically plot the trend of a measured value over time. Measurement Statistics With integrated statistics processing, you can calculate the average, standard, and Allan deviation of a measurement, as well as track the minimum and maximum measured values, all with the push of a button. Histogram Plots To graphically see the average and standard deviation of a set of measurements, you can use the histogram function to see the distribution of measurement results. Optional Modulation Domain Analysis With the optional Tektronix TimeViewTM software (TVA3000), the MCA Series products become high-performance modulation domain analyzers. With high measurement speeds (up to 250k measurement/s) and memory depth at 750k, fast frequency changes can be captured in real time and then analyzed with TimeView. This comprehensive software tool allows for remote instrument control, and the analysis and display of measurement results in a choice of graphs. For example, results can be displayed as raw data, statistical histogram, waveform graph (as if you were using an oscilloscope), or as an FFT spectrum graph. TimeView further allows analysis of modulation parameters like modulation depth or frequency modulation index. Designed to Make Your Work Easier The MCA Microwave Counter Series are designed with the ease of use and familiar operation you have come to expect from Tektronix. Intuitive Operation Menu-oriented settings reduce the risk of mistakes. With dedicated and menu-driven front-panel buttons, you will have fast access to frequently used functions and parameters, reducing setup time. For example, a single-touch Analyze key toggles you between Statistics, Trend Plot, and Histogram modes. Autoset Function Similar to Tektronix oscilloscopes, the front-panel Autoset button will automatically set optimum trigger levels and hysteresis adapted to the actual signal applied. Easy PC Connectivity Connect to your PC with the rear-panel GPIB or USB device ports. The GPIB interface operates in SCPI/GPIB for plug-and-play replacement in existing ATE systems or easy integration into larger test systems. If desired, an emulation mode for existing counter/timers is available. www.tektronix.com 3 Data Sheet Connect Your Bench for Intelligent Debug Frequency Burst A, B, C Easily capture, save, and analyze measurement results from your MCA Microwave Counter Series with the special Tektronix Edition of National Instruments LabVIEW SignalExpressTM software. Every MCA3027 and MCA3040 ships with a free copy of the Limited Edition version of SignalExpress for basic instrument control, data logging, and analysis. The optional Professional Edition offers over 200 built-in functions that provide additional signal processing, advanced analysis, sweeping, limit testing, and user-defined step capabilities. Characteristic SignalExpress supports the range of Tektronix bench instruments*1 enabling you to connect your entire test bench. You can then access the feature-rich tools packed into each instrument from one intuitive software interface. This allows you to automate complex measurements requiring multiple instruments, log data for an extended period of time, time-correlate data from multiple instruments, and easily capture and analyze your results, all from your PC. Only Tektronix offers a connected test bench of intelligent instruments to simplify and speed debug of your complex design. Performance You Can Count On In addition to industry-leading service and support, every MCA Series Microwave/Counter/Analyzer comes backed with a three-year standard warranty. *1 For a complete listing of Tektronix instruments supported by NI LabVIEW Signal Express, visit www.tektronix.com/signalexpress. Characteristics Range Input A, B Input C Acquisition C Minimum Burst Duration Minimum Pulses in Burst Input A, B Input C PRF Range Start Delay Aux Parameters Description 0.001 Hz to 300 MHz 300 MHz to 27 GHz or 40 GHz Manual Down to 40 ns 3 (6 above 160 MHz) 3 x prescaler factor 0.5 Hz to 1 MHz 10 ns to 2 s, 10 ns resolution PRF Period A, B (Single or Average), C (Average) Characteristic Description Mode Range Input A, B Input C Resolution Acquisition C Acquisition time Aux Parameters Input A, B Input C Single, Average 3.3 ns to 1000 s (single, average) 3.3 ns down to 37 ps (27 GHz) or 25 ps (40 GHz) 100 ps (single); 12 digit/s (average) Auto or Manual (within 40 MHz) 25 ms in Auto (typical) Vmax, Vmin, Vp-p Power C in dBm or W Measuring Functions Ratio A/B, B/A, C/A, C/B All measurements are displayed with a large main parameter value and smaller auxiliary parameter values (with less resolution). Some measurements are only available as auxiliary parameters. Characteristic Description Range Input Frequency Input A, B Input C Aux Parameters (10-9) to 1011 Frequency A, B, C Characteristic Range Input A, B Input C Resolution Acquisition C Acquisition time Aux Parameters Input A, B Input C Description DC to 300 MHz 300 MHz to 27 GHz or 40 GHz 12 digits in 1 s measuring time Auto or Manual 25 ms in Auto (typical) Vmax, Vmin, Vp-p Power C in dBm or W 0.1 Hz to 300 MHz 300 MHz to 27 GHz or 40 GHz Freq 1, Freq 2 Time Interval A to B, B to A, A to A, B to B Characteristic Description Range Normal calculation: 0 ns to +106 s Smart calculation: -106 s to +106 s 100 ps single 1.6 ns Smart Time Interval to determine sign (A before B or A after B) Resolution Min Pulse Width Smart Calculation Positive and Negative Pulse Width A, B Characteristic Description Range Min Pulse Width Aux Parameters 2.3 ns to 106 s 2.3 ns Vmax, Vmin, Vp-p Rise and Fall Time A, B 4 www.tektronix.com Characteristic Description Range Trigger Levels Min Pulse Width Aux Parameters 1.5 ns to 106 s 10% and 90% of signal amplitude 1.6 ns Slew rate, Vmax, Vmin Microwave/Counter/Analyzer & Integrated Power Meter -- MCA3000 Series Positive and Negative Duty Factor A, B Characteristic Description Range Frequency Range Aux Parameters 0.000001 to 0.999999 0.1 Hz to 300 MHz Period, pulse width Phase A Relative B, B Relative A Characteristic Description Range Resolution -180 to +360 Single cycle: 0.001 to 10 kHz, decreasing to 1 >10 MHz. Resolution can be improved by averaging (statistics) Up to 160 MHz Freq (A), Va/Vb (in dB) Frequency Range Aux Parameters Vmax, Vmin, Vp-p A, B Characteristic Description Range -50 V to +50 V, -5 V to +5 V Range is limited by the specification for max input voltage without damage (see input A, B) Frequency Range DC, 1 Hz to 300 MHz Mode Vmax, Vmin, Vp-p Resolution 3 mV Uncertainty (5 V range, typical) DC, 1 Hz to 1 kHz 1% + 15 mV 1 kHz to 20 MHz 3% + 15 mV 20 to 100 MHz 10% + 15 mV 100 to 300 MHz 30% + 15 mV Aux Parameters Vmin, Vmax, Vp-p Time Stamping A, B, C Raw time-stamp data together with pulse counts on inputs A, B, or C, accessible through GPIB or USB only. Characteristic Description Max Sample Speed Max Frequency Time-stamp Resolution See GPIB specifications 160 MHz 100 ps Power C Characteristic Range Power Frequency Display Units Resolution Accuracy (Typical) Acquisition Acquisition Time Aux Parameters Description -35 dBm to +10 dBm 300 MHz to 27 GHz or 40 GHz dBm (default) or W 0.01 dBm at 100 ms measuring time <1 dBm to 27 GHz <2 dBm to 40 GHz Auto or Manual (within 40 MHz) 20 to 30 ms in Auto (typical) Frequency C Input and Output Specifications Inputs A and B Characteristic Description Frequency Range DC Coupled: DC to 300 MHz AC Coupled: 10 Hz to 300 MHz 1 M / 20 pF or 50 (VSWR 2:1) Positive or negative 500 ps Impedance Trigger Slope Max Channel Timing Difference Sensitivity Attenuation Dynamic Range (X1) Trigger Level Resolution Uncertainty (X1) AUTO trigger level 15 mVRMS (DC-200 MHz) 25 mVRMS (200-300 MHz) X1, X10 30 mVp-p to 10 Vp-p within 5 V window Readout on display 3 mV (15 mV + 1% of trigger level) Trigger level is automatically set to 50% point of input signal (10% and 90% for rise/fall time) Auto Hysteresis Time Min hysteresis window (hysteresis compensation) Frequency One-third of input signal amplitude Analog LP Filter Nominal 100 kHz, RC type Digital LP Filter 1 Hz to 50 MHz cutoff frequency Max Voltage without Damage 1 M 350 V (DC + AC peak) to 440 Hz, falling to 12 VRMS (X1) at 1 MHz 12 VRMS 50 Connector BNC Input C - 27 GHz or 40 GHz (MCA3027, MCA3040) Characteristic Description Frequency Range 0.3 to 27 GHz or 40 GHz Operating Input Voltage Range -33 to +13 dBm 0.3 to 18 GHz -29 to +13 dBm 18 to 20 GHz -27 to +13 dBm 20 to 27 GHz -23 to +13 dBm 27 to 40 GHz Impedance 50 nominal, AC coupled VSWR 0.3 to 27 GHz < 2.0:1 (typ.) 27 to 40 GHz < 2.5:1 (typ.) FM Tolerance Manual acq. 50 MHzp-p; Frequency C >3.5 GHz 30 MHzp-p; Frequency C <3.5 GHz Auto acq. 20 MHzp-p; for any Frequency C and modulation frequency >0.1 MHz AM Tolerance Any modulation index (minimum signal must be within sensitivity range) Automatic Amplitude 10 dB separation between 2 signals within 30 MHz, Discrimination 20 dB otherwise Max Voltage without +27 dBm (27 and 40 GHz models) Damage Overload Indication ON when Input C power > +10 dBm Connector 2.92 mm spark plug female www.tektronix.com 5 Data Sheet Rear Panel Inputs and Outputs Other Functions Characteristic Description Characteristic Description Reference Input Reference Output Arming Input Impedance Frequency range 1, 5, or 10 MHz; 0.1 to 5 VRMS sine; impedance 1 k 10 MHz; >1 VRMS sine into 50 Arming of all measuring functions Approx. 1 k DC to 80 MHz Measuring Time 20 ns to 1000 s for frequency, burst, and period average. Single cycle for other measuring functions Internal, external, or automatic Freezes the result, until a new measurement is initiated through a restart Graphical indication on front panel and/or SRQ through GPIB Lower limit, upper limit Off, or alarm if value is above, below, inside, or outside limits Stop or Continue Numeric + Graphic 20. Instrument setups can be saved/recalled from internal nonvolatile memory. 10 can be user protected Backlit LCD graphics screen for menu control, numerical readout, and status information 14 digits in Numerical mode 320 x 97 pixels Auxiliary Functions Trigger Holdoff Characteristic Description Time Delay Range 20 ns to 2 s, 10 ns resolution External Start and Stop Arming Arming can be used to synchronize the frequency and power measurements with the start of a burst signal. Minimum burst length must exceed 100 s. Characteristic Description Modes Start and Stop Arming Input Channels A, B, or E (Ext. arming input) Max Rep. Rate for Arming Signal 160 MHz Channel A, B 80 MHz Channel E Start-time Delay Range 20 ns to 2 s, 10 ns resolution Statistics Characteristic Description Functions Maximum, Minimum, Mean, Max-Min, Standard Deviation, and Allan Deviation Numeric, histograms, or trend plots 2 to 2 x 109 samples Off, or capture values above, below, inside, or outside limits Pacing Time Range: 4 s to 500 s Display Sample Size Limit Qualifier Measurement Pacing Time-base Reference Display Hold Limit Alarm Limit Values Settings On Alarm Display Stored Instrument Setups Display Number of digits Resolution GPIB Interface Characteristic Description Compatibility IEEE 488.2-1987, SCPI 199953131A Compatibility mode SH1, AH1, T6, L4, SR1, RL1, DC1, DT1, E2 Interface Functions Max Measurement Rate GPIB 5k readings/s (Block mode) 500 readings/s (individual GET triggered) To internal memory 250k readings/s 750k readings Internal Memory Size USB Interface Characteristic Description USB Version 2.0 full speed (11 Mb/s) Mathematics Characteristic Description Calibration Functions (K*X+L)/M, (K/X+L)/M, or X/M-1. X is current reading and K, L, and M are constants; set using the keyboard or as frozen reference value (X0) Characteristic Description Mode Closed case, menu controlled Calibration Frequencies 0.1, 1, 5, 10, 1.544, and 2.048 MHz General Specifications Environmental Data Characteristic Description Class Operating Temp Storage Temp Humidity MIL-PRF-28800F, Class 3 0 C to +50 C -40 C to +71 C 5-95% (10-30 C) 5-75% (30-40 C) 5-45% (40-50 C) Operating: 2,000 m Storage: 12,000 m Directive 2006/95/EC, EN61010-1, UL61010-1, CAN/CSA C22.2 No. 61010-1 EU Directive 2004/108/EC, EN61326-1, EN61326-2-1, Class A Altitude Safety EMC 6 www.tektronix.com Microwave/Counter/Analyzer & Integrated Power Meter -- MCA3000 Series Ordering Information Power Requirements Characteristic Description Basic Version 90 to 265 VRMS, 45 to 440 Hz, <40 W Models Model Time-base Options Characteristic Standard, Medium Stability High Stability (HS) Ultra High Stability (US) Time-base Type OCXO OCXO OCXO Uncertainty Due to - Aging Per 24h <5x10-10*1 <3x10-10*1 <5x10-9*1 Per month <6x10-8 <1x10-8 <3x10-9 Per year <2x10-7 <5x10-8 <1.5x10-8 Temperature variation (typ. values) <5x10-8 <5x10-9 <2.5x10-9 0-50 C <2x10-8 <1x10-9 <4x10-10 20-26 C <1x10-10 <1x10-11 <5x10-12 Short-term Stability: t = 1 s Root Allan <1x10-10 <1x10-11 <5x10-12 Variance: t = 10 s <1x10-7 <1x10-8 <5x10-9 Power-on Stability 30 min 10 min 10 min Deviation versus final value after 24h ON time, after a warm-up time of: Total Uncertainty, for Operating Temperature 20 C to 26 C, at 2 (95%) Confidence Interval <2.4x10-7 <0.6x10-7 <1.8x10-8 1 year after calibration <4.6x10-7 <1.2x10-7 <3.5x10-8 2 years after calibration Description MCA3027 Microwave/Counter 27 GHz / 100 ps MCA3040 Microwave/Counter 40 GHz / 100 ps MCA3000 Series Includes: Microwave/Counter, line cord, calibration certificate, Quick Start User Manual, CD-ROM with user manual (English, French, German, Spanish, Simplified Chinese, Traditional Chinese, Korean, Russian, Japanese), Programmer's Guide, Technical Specifications, Trial version of TimeViewTM Software, and CD-ROM with National Instruments LabVIEW SignalExpressTM Tektronix Edition, Limited Edition Software. Please specify power plug when ordering. Instrument Options Option Description HS US High-stability Oven Time Base Ultra High-stability Oven Time Base Power Plug Options Option Description A0 A1 A2 A3 A5 A6 A10 A11 North America Universal Euro United Kingdom Australia Switzerland Japan China India *1 After 1 month of continuous operation. Physical Dimension mm in. Height Width Depth 90 210 395 3.6 8.25 15.6 Weight kg lb. Net Shipping 2.7 3.5 5.8 7.5 www.tektronix.com 7 Data Sheet Contact Tektronix: ASEAN / Australasia (65) 6356 3900 Austria 00800 2255 4835* Balkans, Israel, South Africa and other ISE Countries +41 52 675 3777 Belgium 00800 2255 4835* Service Options Option Description CA1 Provides a single calibration event or coverage for the designated calibration interval, whichever comes first Calibration Service 3 Years Calibration Service 5 Years Calibration Data Report Repair Service 5 Years C3 C5 D1 R5 Brazil +55 (11) 3759 7600 Canada 1 800 833 9200 Central East Europe, Ukraine, and the Baltics +41 52 675 3777 Central Europe & Greece +41 52 675 3777 Denmark +45 80 88 1401 Finland +41 52 675 3777 France 00800 2255 4835* Germany 00800 2255 4835* Hong Kong 400 820 5835 Recommended Accessories and Software Accessory Description HCTEK4321 AC4000 174-4401-xx 012-0991-xx 012-1256-xx 012-0482-xx SIGEXPTE Hard Carrying Case Soft Carrying Case USB Host to Device Cable, 3 ft. GPIB Cable, Double Shielded BNC Male to BNC Male, Cable Shielded, 9 ft., 50 BNC Male to BNC Male, Cable Shielded, 3 ft., 50 National Instruments SignalExpressTM Tektronix Edition Interactive Measurement Software - Professional Version TimeViewTM Modulation Domain Analysis Software TVA3000 India 000 800 650 1835 Italy 00800 2255 4835* Japan 81 (3) 6714 3010 Luxembourg +41 52 675 3777 Mexico, Central/South America & Caribbean (52) 56 04 50 90 Middle East, Asia, and North Africa +41 52 675 3777 The Netherlands 00800 2255 4835* Norway 800 16098 People's Republic of China 400 820 5835 Poland +41 52 675 3777 Portugal 80 08 12370 Republic of Korea 001 800 8255 2835 Russia & CIS +7 (495) 7484900 South Africa +41 52 675 3777 Product(s) are manufactured in ISO registered facilities. Spain 00800 2255 4835* Sweden 00800 2255 4835* Product(s) complies with IEEE Standard 488.1-1987, RS-232-C, and with Tektronix Standard Codes and Formats. Switzerland 00800 2255 4835* Taiwan 886 (2) 2722 9622 United Kingdom & Ireland 00800 2255 4835* USA 1 800 833 9200 * European toll-free number. If not accessible, call: +41 52 675 3777 Updated 25 May 2010 For Further Information. Tektronix maintains a comprehensive, constantly expanding collection of application notes, technical briefs and other resources to help engineers working on the cutting edge of technology. Please visit www.tektronix.com Copyright (c) Tektronix, Inc. All rights reserved. Tektronix products are covered by U.S. and foreign patents, issued and pending. Information in this publication supersedes that in all previously published material. Specification and price change privileges reserved. TEKTRONIX and TEK are registered trademarks of Tektronix, Inc. All other trade names referenced are the service marks, trademarks, or registered trademarks of their respective companies. 20 Jul 2010 www.tektronix.com 3CW-25557-0