4
Performance Notes
Rs: Equivalent series resistance – Ohmic resistances (Ohm)
Dielectric Dissipation Factor: tan δ (Polypropylene: 0.0002)
Ths : Hot spot temperature within the capacitor: Ths = Ta + (Ptotal · 280 / SA)
Ta: Ambient temperature
Rth: Thermal resistance: °C/ Watt, indicates hot spot temperature rise due to power dissipation losses
Pmax: Maximum power dissipation: Pmax = (85 ºC - Ta) / Rth (Watts)
PTotal: Total Power generated by Dielectric and Ohmic Losses: P = Vpeak
2
. C . TT . F .DF (Watts) given Voltage
P = I2 . [Rs
+ (XC
. DF)] (Watts) given Current
Where PTotal = PFund + PHarm1 + PHarm2 + .... + PHarm∞
Design life: 60,000 hours 94% survival Ths: 85 °C
0.8
0.85
0.9
0.95
1
1.05
1.1
1.15
1.2
1000 10000 100000 1000000
Applied voltage (Va/Vr)
Expected life time (h)
Expected lifetime vs. applied voltage and ambient temperature
85 ºC
80 ºC
70 ºC
60 ºC
Expected lifetime vs. applied voltage and hot spot temperature
Type PFC Power Factor Correction Capacitors
Notice and Disclaimer: All product drawings, descriptions, specications, statements, information and data
(collectively, the “Information”) in this datasheet or other publication are subject to change. The customer is responsible
for checking, conrming and verifying the extent to which the Information contained in this datasheet or other
publication is applicable to an order at the time the order is placed. All Information given herein is believed to be
accurate and reliable, but it is presented without any guarantee, warranty, representation or responsibility of any kind,
expressed or implied. Statements of suitability for certain applications are based on the knowledge that the Cornell
Dubilier company providing such statements (“Cornell Dubilier”) has of operating conditions that such Cornell
Dubilier company regards as typical for such applications, but are not intended to constitute any guarantee, warranty
or representation regarding any such matter – and Cornell Dubilier specically and expressly disclaims any guarantee,
warranty or representation concerning the suitability for a specic customer application, use, storage, transportation, or
operating environment. The Information is intended for use only by customers who have the requisite experience and
capability to determine the correct products for their application. Any technical advice inferred from this Information or
otherwise provided by Cornell Dubilier with reference to the use of any Cornell Dubilier products is given gratis (unless
otherwise specied by Cornell Dubilier), and Cornell Dubilier assumes no obligation or liability for the advice given or
results obtained. Although Cornell Dubilier strives to apply the most stringent quality and safety standards regarding
the design and manufacturing of its products, in light of the current state of the art, isolated component failures may
still occur. Accordingly, customer applications which require a high degree of reliability or safety should employ suitable
designs or other safeguards (such as installation of protective circuitry or redundancies or other appropriate protective
measures) in order to ensure that the failure of an electrical component does not result in a risk of personal injury or
property damage. Although all product-related warnings, cautions and notes must be observed, the customer should
not assume that all safety measures are indicated in such warnings, cautions and notes, or that other safety measures
may not be required.
CDE Cornell Dubilier • 1605 E. Rodney French Blvd. • New Bedford, MA 02744 • Phone: (508)996-8561 • Fax: (508)996-3830