S3C9442/C9444/F9444/C9452/C9454/F9454 ELECTRICAL DATA
13-3
Table 13-2. DC Electrical Characteristics
(TA = – 40 °C to + 85 °C, VDD = 2.0 V to 5.5 V)
Parameter Symbol Conditions Min Typ Max Unit
Input high
voltage VIH1 Ports 0, 1, 2 and
RESET VDD= 2.0 to 5.5 V 0.8 VDD –VDD V
VIH2 XIN and XOUT VDD- 0.1
Input low
voltage VIL1 Ports 0, 1, 2 and
RESET VDD= 2.0 to 5.5 V – – 0.2 VDD V
VIL2 XIN and XOUT 0.1
Output high
voltage VOH IOH = – 10 mA
ports 0, 1, 2 VDD= 4.5 to 5.5 V VDD-1.5 VDD- 0.4 –V
Output low
voltage VOL IOL = 25 mA
port 0, 1, and 2 VDD= 4.5 to 5.5 V –0.4 2.0 V
Input high
leakage current ILIH1 All input except
ILIH2
VIN = VDD ––1uA
ILIH2 XIN, XOUT VIN = VDD 20
Input low
leakage current ILIL1 All input except
ILIL2 and RESET VIN = 0 V – – –1 uA
ILIL2 XIN, XOUT VIN = 0 V –20
Output high
leakage current ILOH All output pins VOUT = VDD ––2uA
Output low
leakage current ILOL All output pins VOUT = 0 V – – –2 uA
Pull-up resistors RPVIN = 0 V
Ports 0, 1, 2 VDD = 5 V 25 50 100 kΩ
Pull-down
resistors RPVIN = 0 V
Ports 1 VDD = 5 V 25 50 100
Supply current IDD1 Run mode
10 MHz CPU clock VDD = 4.5 to 5.5 V –5 10 mA
3 MHz CPU clock VDD = 2.0 V 2 5
IDD2 Idle mode
10 MHz CPU clock VDD = 4.5 to 5.5 V –24
3 MHz CPU clock VDD = 2.0 V 0.5 1.5
IDD3 Stop mode VDD = 4.5 to 5.5 V
(LVR disable) –0.1 5uA
VDD = 4.5 to 5.5 V
(LVR enable) 100 200
VDD = 2.6 V
(LVR enable) 30 60
NOTE: In STOP (IDD3), IDLE (IDD2) current, current by ADC module is not included.