Power Protection and Conditioning MCR Hardwired Series - Power Line Conditioning with Voltage Regulation The SolaHD MCR Hardwired Series provides excellent noise filtering and surge protection to safeguard connected equipment from damage, degradation or misoperation. Combined with the excellent voltage regulation inherent to our ferroresonant design, the MCR can increase the actual Mean Time Between Failure (MTBF) of protected equipment. The MCR is a perfect choice where dirty power, caused by impulses, swell, sags, brownouts and waveform distortion can lead to costly downtime because of damaged equipment. Applications *Industrial automation and control equipment PLCs *Machine tools *Computer loads and electronic equipment *Robotics *Semiconductor fabrication equipment Selection Tables: Single Phase Group 2 - MCR Series, 60 Hz Only LR044950 Certifications and Compliances All Models *RoHS Compliant Selection Table: Group 2 * Listed (120 VA-750 VA Units) (1-5kVa ("-C8") Units) - UL 1012, CSA C22.2 No. 107.1 Features * 3% output voltage regulation * Noise attenuation - 120 dB common mode - 60 dB transverse mode * Surge protection tested to ANSI/IEEE C62.41 Class A & B Waveform: - <10 V let through typical * Acts as a step-up or step-down transformer * Harmonic filtering *Hardwired * Galvanic isolation provides exceptional circuit protection * 25 year typical MTBF * No maintenance required E47379 Listed (7.5kVA-15kVA Units) (1-5kVa ("-8") Units) * - UL 1012 Selection Table: Group 3 * Listed (500 VA-3kVA Units) - UL 1012, CSA C22.2 No. 107.1 * Certified (5kVA-15kVA Units) - CSA C22.2 No. 66 Selection Table: Group 4 * Listed - UL 1012, CSA C22.2 No. 107.1 Related Products * On-line UPS (S4K Industrial) * Surge Protection * Three Phase Power Conditioners * Active Tracking(R) Filters VA Catalog Number Voltage Input Voltage Output Height in (mm) Width in (mm) Depth in (mm) Ship Weight lbs (kg) Design Style Elec Conn 120 63-23-112-4 120, 208, 240, 480 120 9 (229) 4 (102) 5 (127) 15 (7) 1 D 250 63-23-125-4 120, 208, 240, 480 120 10 (254) 6 (152) 8 (203) 27 (12) 1 D 500 63-23-150-8 120, 208, 240, 480 120, 208, 240 13 (330) 9 (229) 7 (178) 37 (17) 1 E 750 63-23-175-8 120, 208, 240, 480 120, 208, 240 14 (356) 9 (229) 7 (178) 52 (24) 1 E 120, 208, 240 17 (432) 9 (229) 7 (178) 62 (28) 1 E 1000 * 63-23-210-8 120, 208, 240, 480 1500 * 63-23-215-8 120, 208, 240, 480 120, 208, 240 17 (432) 13 (330) 9 (229) 95 (43) 1 E 2000 * 63-23-220-8 120, 208, 240, 480 120, 208, 240 18 (457) 13 (330) 9 (229) 109 (49) 1 E 3000 * 63-23-230-8 120, 208, 240, 480 120, 208, 240 19 (483) 13 (330) 9 (229) 142 (64) 1 E 5000 * 63-23-250-8 120, 208, 240, 480 120, 208, 240 28 (711) 13 (330) 9 (229) 222 (101) 1 E 7500 63-28-275-8 208, 240, 480 120, 208, 240 27 (686) 26 (660) 9 (229) 362 (164) 2 F 10000 63-28-310-8 208, 240, 480 120, 208, 240 28 (711) 26 (660) 9 (229) 446 (202) 2 F 15000 63-28-315-8 208, 240, 480 120, 208, 240 28 (711) 38 (965) 10 (254) 710 (322) 3 F * Canadian option: cULus units must be ordered by changing "-8" (UL only) to "-C8". 44 Dimensions are approximate. See user manual for exact dimensions. Visit our website at www.emerson.com or contact Technical Services at (800) 377-4384 with any questions. (c) February 2020 Power Protection and Conditioning Selection Tables: Single Phase Group 3 - MCR Series, 60 Hz Only VA Catalog Number 500 Voltage Input Voltage Output Height in (mm) Width in (mm) Depth in (mm) Ship Weight lbs (kg) Design Style Elec Conn 63-31-150-8 600 120, 208, 240 13 (330) 9 (229) 7 (178) 38 (17) 1 B 1000 63-32-210-8 600 120, 208, 240 17 (432) 9 (229) 7 (178) 62 (28) 1 B 2000 63-32-220-8 600 120, 208, 240 18 (457) 13 (330) 10 (254) 109 (49) 1 B 3000 63-32-230-8 600 120, 208, 240 19 (483) 13 (330) 10 (254) 142 (64) 1 B 5000 63-29-250-8 208, 240, 480, 600 120, 208, 240 28 (711) 13 (330) 10 (254) 221 (100) 1 A 7500 63-29-275-8 208, 240, 480, 600 120, 208, 240 27 (686) 25 (635) 10 (254) 360 (163) 2 A 10000 63-29-310-8 208, 240, 480, 600 120, 208, 240 28 (711) 25 (635) 10 (254) 441 (200) 2 A 15000 63-29-315-8 208, 240, 480, 600 120, 208, 240 28 (711) 38 (965) 10 (254) 706 (320) 3 A Group 4 - MCR Series, 50 Hz Only (5% output voltage regulation) Height in (mm) Width in (mm) Depth in (mm) Ship Weight lbs (kg) Design Style Elec Conn 110, 120, 220, 240, 380, 415 110, 120, 220, 240 9 (229) 6 (152) 8 (203) 24 (11) 1 C 110, 120, 220, 240, 380, 415 110, 120, 220, 240 11 (279) 6 (152) 8 (203) 27 (12) 1 C 63-23-650-8 110, 120, 220, 240, 380, 415 110, 120, 220, 240 13 (330) 9 (229) 7 (178) 40 (18) 1 C 1000 63-23-710-8 110, 120, 220, 240, 380, 415 110, 120, 220, 240 18 (457) 9 (229) 7 (178) 64 (29) 1 C 2000 63-23-720-8 110, 120, 220, 240, 380, 415 110, 120, 220, 240 18 (457) 13 (330) 10 (254) 113 (51) 1 C 3000 63-23-730-8 110, 120, 220, 240, 380, 415 110, 120, 220, 240 27 (686) 13 (330) 10 (254) 162 (73) 1 C 5000 63-23-750-8 110, 120, 220, 240, 380, 415 110, 120, 220, 240 30 (762) 13 (330) 10 (254) 266 (121) 1 C 7500 63-28-775-8 220, 240, 380, 415 110, 120, 220, 240 28 (711) 26 (660) 10 (254) 393 (178) 2 C1 10000 63-28-810-8 220, 240, 380, 415 110, 120, 220, 240 30 (762) 26 (660) 10 (254) 490 (222) 2 C2 15000 63-28-815-8 220, 240, 380, 415 110, 120, 220, 240 30 (762) 38 (965) 10 (254) 776 (352) 3 C2 VA Catalog Number 120 63-23-612-8 250 63-23-625-8 500 Voltage Input Voltage Output Specifications Parameter Condition Value Input Voltage Current 1 Frequency Continuous at full load (lower input voltage possible at lighter load) +10% to -20% of nominal For temporary surge or sags +20% to -35% of nominal at Full Load & 80% of nominal input voltage Iin (VA/.89)/(Vin x 80%) See Operating Characteristics section for details. 50 Hz or 60 Hz depending on model Output 2 Line Regulation Overload Protection Output Harmonic Distortion Noise Attenuation Vin >80% and <110% of nominal 5% for 50 Hz units, 3% for 60 Hz units At Nominal Input Voltage Current limited at 1.65 times rated current At full load within input range 3% total RMS content Common Mode Transverse Mode 120 dB 60 dB General Efficiency At Full Load Up to 92% -- 40% Storage Temperature Humidity <95% non-condensing -20 to +85C Operating Temperature Humidity <95% non-condensing -20 to 50C Full Resistive Noise 35 dBA to 65 dBA Minimum Loading Audible Noise Warranty 10 + 2 year limited warranty Notes: 1 - Consult user manual for fuse sizing. 2 - It is recommended that the unit run at a minimum of 40-50% load. Dimensions are approximate. See user manual for exact dimensions. Visit our website at www.emerson.com or contact Technical Services at (800) 377-4384 with any questions. (c) February 2020 45 Power Protection and Conditioning Electrical Connections B A Primary Voltage Interconnect Connect Lines To 208 H1 to H4 H2 to H5 H1 & H5 240 H1 to H4 H3 to H6 H1 & H6 480 H3 to H4 H1 & H6 Primary Voltage Interconnect 600 H1 & H2 600 H3 to H4 H1 & H7 Secondary Voltage Interconnect Connect Lines To Secondary Voltage 120 X1 & X2 or X3 & X2 208 X4 & X5 240 X1 & X3 Interconnect 220-240 H1 to H3 H2 to H5 Connect Lines To H1 & H5 380-415 H2 to H3 H1 & H4 Secondary Voltage Interconnect Connect Lines To 110 X1 & X2 or X2 & X3 120 X4 & X2 or X5 & X2 220 X1 & X3 240 X4 & X5 MCR 50 Hz 7500 VA 46 Interconnect Connect Lines To 110-120 H1 to H3 H2 to H4 H1 & H4 220-240 H2 to H3 H1 & H4 380-415 H2 to H3 H1 & H5 Secondary Voltage Interconnect Connect Lines To 110 X1 & X2 or X3 & X2 120 X1 & X2 or X3 & X2 120 X4 & X2 or X5 & X2 208 X4 & X5 220 X1 & X3 X1 & X3 240 X4 & X5 240 MCR 60 Hz 500-3000 VA MCR 50 Hz 120-5000 VA C2 C1 Interconnect Primary Voltage Connect Lines To MCR 60 Hz 5000-15000 VA Primary Voltage Connect Lines To C D Primary Voltage Interconnect Connect Lines To Primary Voltage 220-240 H2 to H3 H1 & H4 120 H1 & H2 380-415 H2 to H3 H1 & H5 208 H1 & H3 Connect Lines To 240 H1 & H4 110 X1 & X2 or X3 & X2 480 H1 & H5 120 X4 & X2 or X5 & X2 Secondary Voltage 220 X1 & X3 120 240 X4 & X5 Secondary Voltage Interconnect Interconnect Interconnect Connect Lines To Connect Lines To X1 & X2 MCR 60 Hz 120-250 VA MCR 50 Hz 10000-15000 VA Visit our website at www.emerson.com or contact Technical Services at (800) 377-4384 with any questions. (c) February 2020 Power Protection and Conditioning Electrical Connections E Primary Voltage Interconnect Connect Lines To H1 & H2 Primary Voltage 208 H1 & H3 208 240 H1 & H4 240 H2 & H4 480 H1 & H5 480 H1 & H4 120 G F Interconnect Connect Lines To H2 & H3 Connect Lines To H1 to H3 to H5 to H7 H2 to H4 to H6 to H8 H1 & H2 240 H2 to H3 H6 to H7 H1 to H5 H4 to H8 H1 & H4 480 H2 to H3 H4 to H5 H6 to H7 H1 & H8 Interconnect Connect Lines To Connect Lines To 120 X1 & X2 or X3 & X2 120 X1 & X2 or X3 & X2 208 X4 & X5 208 X4 & X5 Secondary Voltage X1 & X3 120 Interconnect 240 X1 & X3 Connect Lines To Interconnect 120 Secondary Voltage Secondary Voltage Interconnect Primary Voltage 240 X1 & X2 CVS 60 Hz 250 VA only MCR 60 Hz 7500, 10000 and 15000 VA MCR 60 Hz 500-5000 VA H Series-Multiple Primary with Tap for two input voltages J Open MCR/CVS terminal Primary Voltage Interconnect Connect Lines To 120 H1 to H3 to H6 to H8 H2 to H5 to H7 to H10 H1 & H2 30 & 60 VA Primary Voltage 120 VA Primary Voltage 7500 VA Primary Voltage Interconnect Connect Lines To 120 N/A N/A Note: H3 & H4 are not used H1 & H2 H1 & H4 208 H2 to H3 H1 to H6 H7 to H8 H4 to H9 H1 & H4 N/A 120 240 H1 to H3 H2 to H4 240 H2 to H3 H7 to H8 H1 to H6 H5 to H10 H1 & H5 N/A 240 480 H2 to H3 H1 & H4 480 H2 to H3 H5 to H6 H7 to H8 H1 & H10 30 & 60 VA Secondary Voltage 120 VA Secondary Voltage 7500 VA Secondary Voltage Interconnect Connect Lines To Secondary Voltage Interconnect Connect Lines To 120 120 N/A X1 & X2 120 X1 & X2 or X3 & X2 N/A N/A 120 X1 & X2 or X3 & X2 240 X1 & X3 N/A N/A 240 X1 & X3 CVS 60 Hz 500-5000 VA Visit our website at www.emerson.com or contact Technical Services at (800) 377-4384 with any questions. (c) February 2020 Note: Secondaries are not grounded. Ground X2 per Code. CVS 60 Hz 30-120 VA & 7500 VA 47