A Global Leader in the Design, Development, and Manufacture of Sensor and Magnetic Components www.standexmeder.com Series Datasheet - SHV Reed Relays SHV Series Reed Relays Features: Small High Voltage Relay, Dielectric Strength up to 4 kVDC, Internal Magnetic Shield, UL-listed Applications: High Density Assembly, Portable Test and Medical Equipment, Cable and In-Circuit Tester Markets: Test & Measurement, ATE, Medical & Others SHV00-1A85-78X0K Part Description: Nominal Voltage Contact Quantity Contact Form Switch Model Pin Out Option Breakdown Voltage 05, 12, 24 1 A 85 78 L, D 2K, 3K, 4K See page 3 for explanation Switch Model 85 Contact Data (at 20C) Unit (A-Dry) Contact Material Rhodium Rated Power (max.) Any DC combination of V&A not to exceed max rated power Switching Voltage (max.) DC or peak AC Switching Current (max.) DC or peak AC Carry Current (max.) DC or peak AC Contact Resistance (max.) @ 0.5V & 10mA, Measured with 40% Pull-In Overdrive Breakdown Voltage (min.) (depending on configuration) According to IEC 60255-27 Operating Time (max.) Including Bounce, Measured with 40% Pull-In Overdrive Release Time (max.) Measured without Coil Suppression Insulation Resistance (min. / typ.) Rh<45%, 100V Test Voltage Capacitance (typ.) @ 10kHz across Open Switch USA: Europe: Asia: +1 866/782 6339 +49 7731/8399-0 +86 21/37820625 100 W 1,000 V 1.0 A 2.5 A 150 mOhm 2/3/4 kVDC 1.1 ms 0.1 ms 1010 / 1012 Ohm 0.5 pF salesusa@standexmeder.com info@standexmeder.com salesasia@standexmeder.com Page 1/3 Version 03 14. Nov. 2017 D. Stastny A Global Leader in the Design, Development, and Manufacture of Sensor and Magnetic Components www.standexmeder.com Series Datasheet - SHV Reed Relays Coil Data (at 20C) Contact Form Switch Model Coil Voltage (VDC) Pull-In Voltage (VDC) Drop-Out Voltage (VDC) Coil Power (mW) Nominal Maximal Typical ( 10 %) Maximal Minimal Nominal 05 7.5 220 3.75 0.5 110 12 16 500 8.4 1.8 288 05 7.5 180 3.75 0.5 139 12 16 500 8.4 1.8 288 24 30 2,000 16.4 3.6 288 05 7.5 140 3.75 0.5 179 12 16 500 8.4 1.8 288 24 30 2,000 16.4 3.6 288 85 (2K) 1A Coil Resistance (Ohm) 85 (3K) 85 (4K) The Pull-In, Drop-Out Voltage and Coil Resistance will change at rate of 0.4% per C Relay Data (at 20C) Unit Dielectric Strength Coil/Contact (min.) 4 kVDC 1011 / 1012 Ohm 1.2 pF 50 g 20 g -40 to 105 C -40 to 125 C 260 C According to EN60255-5 Insulation Resistance Coil/Contact (min./typ.) Rh<45%, 200V Test Voltage Capacitance Coil/Contact (typ.) @ 10 kHz Shock Resistance (max.) 1/2 sine wave duration 11ms Vibration Resistance (max.) 10 - 2,000 Hz Operating Temperature (max.) Surrounding of the relay's housing Storage Temperature (max.) Surrounding of the relay's housing Soldering Temperature (max.) 5 seconds max. Washability Aqueous rinsing suitable. Proper drying necessary Dimensions in mm [inch] Tolerances acc. to ISO 2768-m Fully Sealed Handing & Assembly Instructions Life Test Data (with resistive load, for general information only) Switching inductive and/or capacitive loads create voltage and/or current peaks, which may damage the relay. Protective circuits need to be used - see our website. External magnetic fields and magnetic effects, due to adjacent relays in high density matrices that may influence the relays' electrical characteristics, must be taken into consideration. Mechanical shock impacts, e.g. dropping the relays, may cause immediate or post-installation failure. Suppressing coil diode can have a negative influence on total number of switching cycles, especially by switching high voltage Wave soldering: maximum 260C / 5 seconds. USA: Europe: Asia: SHV Reed Relay Dimensions +1 866/782 6339 +49 7731/8399-0 +86 21/37820625 Load (DC) KSK-1A85 900V/1mA 500V/1mA 100V/10mA 20V/500mA 10V/100mA <5V/10mA 1,E+05 1,E+06 1,E+07 1,E+08 1,E+09 Typical Number of Operations salesusa@standexmeder.com info@standexmeder.com salesasia@standexmeder.com Page 2/3 Version 03 14. Nov. 2017 D. Stastny A Global Leader in the Design, Development, and Manufacture of Sensor and Magnetic Components www.standexmeder.com Series Datasheet - SHV Reed Relays Pin Out (Top View) 78L 78D Pitch 2.54 mm [0.10 inch] Glossary Option Glossary Contact Form Form A Form B Form C Form E NO = Normally Open Contacts SPST = Single Pole Single Throw NC = Normally Closed Contacts SPST = Single Pole Single Throw Changeover SPDT = Single Pole Double Throw Latching unchanged until an opposite impulse is present SHV Relays are available only in "Form A" configuration L Standard, with Magnetic Shield D with Diode, with Magnetic Shield M with Magnetic Shield, without Diode Q with Diode and Magnetic Shield HR High Resistance Coil SHV Relays are available with "L" and "D" Option Breakdown Voltage Option 2K 2 kVDC across open contact 3K 3 kVDC across open contact 4K 4 kVDC across open contact Test voltage measured according to IEC 60255-27 Please note: All technical specifications on this series datasheet refer to the standard product range. Modifications in the sense of technical progress are reserved. For general information only. For more specific information, please consult the product datasheet, available upon request. This series datasheet could contain technical inaccuracies or typographical errors. Changes are periodically made to the information herein. These changes will be incorporated in future revisions. For deviating values, latest specifications and product details, please contact your nearest sales office. USA: Europe: Asia: +1 866/782 6339 +49 7731/8399-0 +86 21/37820625 salesusa@standexmeder.com info@standexmeder.com salesasia@standexmeder.com Page 3/3 Version 03 14. Nov. 2017 D. Stastny