A Global Leader in the Design, Development, and
Manufacture of Sensor and Magnetic Components
Series Datasheet SHV Reed Relays www.standexmeder.com
SHV Series
Reed Relays
Features: Small High Voltage Relay, Dielectric Strength up to 4 kVDC, Internal Magnetic Shield, UL-listed
Applications: High Density Assembly, Portable Test and Medical Equipment, Cable and In-Circuit Tester
Markets: Test & Measurement, ATE, Medical & Others
Part
Description: S H V 00- 1 A 85-78X 0 K
Nominal
Voltage
Contact
Quantity
Contact
Form
Switch
Model Pin Out Option
Breakdown
Voltage
05, 12, 24 1 A 85 78 L, D 2K, 3K, 4K
See
page 3 for explanation
Contact Data
(at 20°C)
Switch Model
Unit
85
(A-Dry)
Contact Material
Rhodium
Rated Power
(max.)
Any DC combination of V&A not to exceed max rated power
100 W
Switching Voltage
(max.)
DC or
peak AC 1,000 V
Switching Current
(max.)
DC
or peak AC 1.0 A
Carry Current
(max.)
DC
or peak AC 2.5 A
Contact Resistance
(max.)
@
0.5V & 10mA, Measured with 40% Pull-In Overdrive 150 mOhm
Breakdown Voltage
(min.) (depending on configuration)
According to IEC
60255-27 2 / 3 / 4 kVDC
Operating
Time (max.)
Including Bounce, Measured with 40% Pull
-In Overdrive 1.1 ms
Release Time (max.)
Measured without Coil Suppression
0.1 ms
Insulation Resistance (min. / typ.)
Rh<45
%, 100V Test Voltage 1010 / 1012 Ohm
Capacitance (typ.)
@
10kHz across Open Switch 0.5 pF
Version 03
14. Nov. 2017
D. Stastny
Page 1/3
USA: +1 866/782 6339 │ salesusa@standexmeder.com
Europe: +49 7731/8399-0 │ info@standexmeder.com
Asia: +86 21/37820625 │ salesasia@standexmeder.com
A Global Leader in the Design, Development, and
Manufacture of Sensor and Magnetic Components
Series Datasheet SHV Reed Relays www.standexmeder.com
Coil Data (at 20°C) Coil Voltage
(VDC)
Coil Resistance
(Ohm)
Pull-In
Voltage
(VDC)
Drop-Out
Voltage
(VDC)
Coil Power
(mW)
Contact
Form
Switch
Model Nominal Maximal Typical (±
10 %)
Maximal Minimal Nominal
1A
85 (2K)
05 7.5 220 3.75 0.5 110
12 16 500 8.4 1.8 288
85 (3K)
05 7.5 180 3.75 0.5 139
12 16 500 8.4 1.8 288
24 30 2,000 16.4 3.6 288
85 (4K)
05 7.5 140 3.75 0.5 179
12 16 500 8.4 1.8 288
24 30 2,000 16.4 3.6 288
The Pull
-In, Drop-Out Voltage and Coil Resistance will change at rate of 0.4% per °C
Relay
Data (at 20°C) Unit
Dielectric Strength Coil/Contact (min.)
According to EN60255
-5 4 kVDC
Insulation Resistance Coil/Contact
(min./typ.)
Rh<45%, 200V Test Voltage 1011 / 1012 Ohm
Capacitance Coil/Contact (typ.)
@ 10 kHz
1.2 pF
Shock Resistance (max.)
1/2 sine wave duration 11ms
50 g
Vibration Resistance (max.)
10
2,000 Hz 20 g
Operating Temperature (max.)
Surrounding of the relay’s housing
-40 to 105 °C
Storage Temperature (max.)
Surrounding of the relay’s housing
-40 to 125 °C
Soldering
Temperature (max.)
5 seconds max.
260 °C
Washability
Aqueous rinsing suitable
. Proper drying necessary Fully Sealed
Dimensions in mm [inch]
Tolerances acc. to ISO 2768-m
Version 03
14. Nov. 2017
D. Stastny
Page 2/3
USA: +1 866/782 6339 │ salesusa@standexmeder.com
Europe: +49 7731/8399-0 │ info@standexmeder.com
Asia: +86 21/37820625 │ salesasia@standexmeder.com
(with resistive load, for general information only)
1,E+05 1,E+06 1,E+07 1,E+08 1,E+09
<5V/10mA
10V/100mA
20V/500mA
100V/10mA
500V/1mA
900V/1mA
Typical Number of Operations
Load (DC)
KSK-1A85 KSK-1A85 KSK-1A85 KSK-1A85 KSK-1A85 KSK-1A85 KSK-1A85 KSK-1A85
Handing & Assembly Instructions
Switching inductive and/or capacitive loads create voltage
and/or current peaks, which may damage the relay. Protective
circuits need to be used - see our website.
External magnetic fields and magnetic effects, due to adjacent
relays in high density matrices that may influence the relays'
electrical characteristics, must be taken into consideration.
Mechanical shock impacts, e.g. dropping the relays, may cause
immediate or post-installation failure.
Suppressing coil diode can have a negative influence on total
number of switching cycles, especially by switching high voltage
Wave soldering: maximum 260°C / 5 seconds.
A Global Leader in the Design, Development, and
Manufacture of Sensor and Magnetic Components
Series Datasheet SHV Reed Relays www.standexmeder.com
Pin Out
(Top View)
78L
Pitch 2.54 mm [0.10 inch]
Please note: All technical specifications on this series datasheet refer to the standard product range. Modifications in the sense of technical progress are reserved.
For general information only. For more specific information, please consult the product datasheet, available upon request.
This series datasheet could contain technical inaccuracies or typographical errors. Changes are periodically made to the information herein. These changes will be
incorporated in future revisions.
For deviating values, latest specifications and product details, please contact your nearest sales office.
78D
Version 03
14. Nov. 2017
D. Stastny
Page 3/3
USA: +1 866/782 6339 │ salesusa@standexmeder.com
Europe: +49 7731/8399-0 │ info@standexmeder.com
Asia: +86 21/37820625 │ salesasia@standexmeder.com
Glossary Option
L
Standard
, with Magnetic Shield
D
with Diode, with Magnetic Shield
M
with Magnetic Shield, without Diode
Q
with Diode and Magnetic Shield
HR
High Resistance Coil
SHV Relays are available with “L” and “D” Option
Glossary Contact Form
Form
A
NO = Normally Open Contacts
SPST = Single Pole Single
Throw
Form B
NC = Normally Closed
Contacts
SPST
= Single Pole Single Throw
Form C
Changeover
SPDT = Single Pole Double Throw
Form
E
Latching
unchanged until an opposite impulse is present
SHV Relays are available only in “Form A” configuration
Breakdown
Voltage Option
2K
2
kVDC across open contact
3K
3 kVDC across open contact
4K
4 kVDC across open contact
Test voltage measured according to IEC 60255-27