AC-DC
Specification
5-30 Watts
•Ultra Compact Size
•Single, Dual & Triple Outputs
•Open Frame PCB & Chassis Mount
•Encapsulated PCB Mount Versions
•<0.3 W No Load Input Power
•Peak Load Capability
•3 Year Warranty
ECL Series
Input
Input Voltage • 85-264 VAC (120-370 VDC)
Input Frequency • 47-63 Hz
Input Current • ECL05: 0.1 A rms, ECL10: 0.2 A rms
ECL15: 0.3 A rms, ECL25: 0.4 A rms
ECL30: 0.8 A rms at 230 VAC
Inrush Current • 20 A at 115 VAC, 40 A at 230 VAC,
cold start at 25 °C
Earth Leakage Current • Class II construction no earth
Power Factor • EN61000-3-2, class A
No Load Input Power • <0.3 W
Input Protection • ECL05/10: Internal T1 A/250 VAC fuse
ECL15/25/30: Internal T2 A/250 VAC fuse
Output
Output Voltage • See tables
Output Voltage Trim • ±5% on output 1 only, on multiple output
versions, V2 & V3 will track by same
percentage, (not ‘-E’ or ‘-S’ versions)
Initial Set Accuracy • ±1% for output 1,
±1% for output 2 of UD01 & UD02 versions,
±5% for output 2 & output 3 of other versions
Minimum Load • Single output versions: none,
Multi output versions:
UD01 & UD02: 10% V1 & V2
UD03: 10% V1, 20% V2
UT02 & UT03: 10% V1, 20% V2 & V3
to meet regulation specifications
Start Up Delay • 3 s max
Start Up Rise Time • 14 ms max
Hold Up Time • 16 ms typical for single output versions,
12 ms typical for multiple output versions,
at full load & 115 VAC
Line Regulation • ±0.5% max for single output versions and
output 1 of multiple output versions,
±0.9% max for output 2 & output 3 of
multiple output versions
Load Regulation • 1% max for single output versions,
for multiple output versions (see note 5)
Cross Regulation • Multi output versions only (see note 5)
Transient Response • 4% max deviation, recovery to within
1% in 500 µs for a 25% load change
Ripple & Noise • Single output versions:
3.3-5 V versions: 50 mV pk-pk,
12-15 V versions: 120 mV pk-pk,
24-48 V versions: 200 mV pk-pk,
Multiple output versions: 1% pk-pk on any
output, 20 MHz bandwidth
Overvoltage Protection • 115-140% Vnom, 195-216% Vnom
ECL05/10/15/25 with 3.3 V
Overload Protection • Single output versions: ECL05/10/15:
120-150%, ECL25: 120-170% of total
power
Multiple output versions: 140-200% of
total power
Short Circuit Protection • Trip and restart (hiccup mode)
Temperature • 0.05%/°C
Coefficient
xppower.com
General
Efficiency • See tables
Isolation • 3000 VAC Input to Output
Switching Frequency • 70 kHz typical
Power Density • ECL05: 2.25 W/In3 (PCB Mount version)
ECL10: 5.50 W/In3 (PCB Mount version)
ECL15: 5.30 W/In3 (PCB Mount version)
ECL25: 5.90 W/In3 (PCB Mount version)
ECL30: 7.10 W/In3 (PCB Mount version)
MTBF • ECL05/10: >450 kHrs,
ECL15/25/30: >400 kHrs,
to MIL-HDBK-217F at 25 °C, GB
Environmental
Operating Temperature • -20 °C to +70 °C, derate linearly from
100% at +50 °C to 50% at +70 °C
Cooling • Convection-cooled
Operating Humidity • 95% RH, non-condensing
Storage Temperature • -40 °C to +85 °C
Operating Altitude • 3000 m
Vibration • 2 g, 10 Hz to 500 Hz, 10 mins/cycle,
60 mins each cycle
EMC & Safety
Emissions • EN55022, level B conducted & radiated
Harmonic Currents • EN61000-3-2, class A
Voltage Flicker • EN61000-3-3
ESD Immunity • EN61000-4-2, level 3 Perf Criteria A
Radiated Immunity • EN61000-4-3, 10 V/m 80% mod
Perf Criteria A
EFT/Burst • EN61000-4-4, level 3, Perf Criteria A
Surge • EN61000-4-5, installation class 3,
Perf Criteria A
Conducted Immunity • EN61000-4-6, 10 Vrms Perf Criteria A
Magnetic Fields • EN61000-4-8, 10 A/m, Perf Criteria A
Dips & Interruptions • EN61000-4-11, 30% for 10 ms,
60% for 100 ms, 100% for 5000 ms
Perf Criteria A, B, B
Safety Approvals • IEC60950-1, EN60950-1, UL60950-1,
CSA22.2 No. 234 per cUL