1SS420 TOSHIBA Diode Silicon Epitaxial Schottky Barrier Type 1SS420 High-Speed Switching Applications * Unit: mm Low reverse current: IR = 5 A (max) Maximum Ratings (Ta = 25C) Characteristic Symbol Rating Unit VRM 35 V Reverse voltage VR 30 V Maximum (peak) forward current IFM 300 mA Maximum (peak) reverse voltage Average forward current Surge current (10 ms) Power dissipation Junction temperature IO 200 mA IFSM 1 A P* 150 mW Tj 125 C Storage temperature range Tstg -55~125 C Operating temperature range Topr -40~100 C * JEDEC JEITA TOSHIBA 1-1G1A Weight: 0.0014 g (typ.) Mounted on a glass-epoxy circuit board of 20 x 20 mm, pad dimensions of 4 x 4 mm. Electrical Characteristics (Ta = 25C) Characteristic Symbol Test Circuit VF (1) VF (2) Min Typ. Max IF = 1 mA 0.29 IF = 10 mA 0.36 VF (3) IF = 200 mA 0.52 0.6 Reverse current IR VR = 30 V 5 A Total capacitance CT VR = 0, f = 1 MHz 20 pF Forward voltage Test Condition Equivalent Circuit (Top View) Unit V Marking S6 1 2005-03-23 1SS420 IF - VF IR - VR 100 100u 100 100m REVERSE CURRENTIR (A) FORWARD CURRENTIF (A) 1 1000 Ta = 100C 10 10m 25 1m1 100u0 -25 10u0 1u0 0 0.2 0.4 0.6 10u 10 Ta = 100C 1u1 100n0 10n0 25 1n0 -25 100p0 10p0 0.8 0 FORWARD VOLTAGEVF (V) 5 10 15 20 25 REVERSE VOLTAGEVR(V) 30 CT - VR TOTAL CAPACITANCE CT (pF) 100 Ta = 25C f = 1MHz 10 1 0 10 20 30 REVERSE VOLTAGE VR (V) 2 2005-03-23 1SS420 RESTRICTIONS ON PRODUCT USE 030619EAA * The information contained herein is subject to change without notice. * The information contained herein is presented only as a guide for the applications of our products. No responsibility is assumed by TOSHIBA for any infringements of patents or other rights of the third parties which may result from its use. No license is granted by implication or otherwise under any patent or patent rights of TOSHIBA or others. * TOSHIBA is continually working to improve the quality and reliability of its products. Nevertheless, semiconductor devices in general can malfunction or fail due to their inherent electrical sensitivity and vulnerability to physical stress. It is the responsibility of the buyer, when utilizing TOSHIBA products, to comply with the standards of safety in making a safe design for the entire system, and to avoid situations in which a malfunction or failure of such TOSHIBA products could cause loss of human life, bodily injury or damage to property. In developing your designs, please ensure that TOSHIBA products are used within specified operating ranges as set forth in the most recent TOSHIBA products specifications. Also, please keep in mind the precautions and conditions set forth in the "Handling Guide for Semiconductor Devices," or "TOSHIBA Semiconductor Reliability Handbook" etc.. * The TOSHIBA products listed in this document are intended for usage in general electronics applications (computer, personal equipment, office equipment, measuring equipment, industrial robotics, domestic appliances, etc.). These TOSHIBA products are neither intended nor warranted for usage in equipment that requires extraordinarily high quality and/or reliability or a malfunction or failure of which may cause loss of human life or bodily injury ("Unintended Usage"). Unintended Usage include atomic energy control instruments, airplane or spaceship instruments, transportation instruments, traffic signal instruments, combustion control instruments, medical instruments, all types of safety devices, etc.. Unintended Usage of TOSHIBA products listed in this document shall be made at the customer's own risk. * TOSHIBA products should not be embedded to the downstream products which are prohibited to be produced and sold, under any law and regulations. 3 2005-03-23