Switches & Pilot Devices o22mm - HW Series Switches & Pilot Devices HW Series -- 22mm IEC Style Global Pushbuttons Key features: Signaling Lights * Locking lever removable contact blocks * Finger-safe IP20 contacts as standard, other terminal styles available * Tamperproof construction * All E-stops meet EN418 and are compliant with SEMI S2 standards * Worldwide approvals * Easy to assemble * Choice of black plastic or metallic front bezels * Incandescent or LED illumination * Transformer or full voltage * Slow make double break self cleaning contacts HW: The Best Engineered Switch in the World Complete with finger-safe contact blocks offering IP20 protection, these 7/8" (22mm) switches include illuminated and non-illuminated pushbuttons, pilot All switches also incorporate mechanically keyed safety locking levers, ensuring correct installation and maintaining safety in high-vibration applications. Registration No. R9551089 (E-stops) Registration No. R50054316 (Dual Pushbuttons) Registration No. J9650511 (Pilot Lights) Registration No. J9551458 (all other switches) (R) File No. E68961 lights, selector switches, and emergency stop switches. Certificate No. 2005010305145656 File No. LR92374 Maximum Inrush Current 40 A (40 ms) Rated Insulation Voltage 600V Rated Switching Over-Voltage Less than 4kV, conforming to IEC60947-1 Rated Impulse Withstanding Voltage 4kV for contact circuit, 2.5kV for lamp circuit Rated Thermal Current 10 Amp Minimum Switching Capacity 5 mA at 3V AC/DC Electrical Reliability MTBF < 1 fault for 10 million operation cycles (3V DC, 5mA) Lamp Ratings Incandescent: 1 W LEDs: 6V/17mA max, 12V & 24V/11mA max, 120 & 240V/10mA max Contactors Rated Operational Characteristics AC-15: A600 or Ue = 250V, le = 3A (NO, NC, NO-EM, NC-LB) DC-13: P600 or Ue = 125V, le = 1.1A (NO, NC) DC-13: Q600 or Ue = 125V, le = 0.9A (NO-EM, NC-LB) Timers Specifications Electrical Relays & Sockets IDEC's HW switches are "The best engineered switch in the world" for a reason. Carrying the CE mark, UL, CSA, CCC (Chinese), and TUV approvals, these switches are designed for use in almost any part of the world. Terminal Blocks Circuit Breakers 800-262-IDEC (4332) * USA & Canada 549 Switches & Pilot Devices Mechanical Contact Operation Slow break NC or NO, self-cleaning Positive Action Operation (Emergency Stops with NC contacts) 5.5mm to 10mm travel to latch, 45N minimum force to latch 10mm maximum travel, 1,800 operations per hour maximum for a Pushlock Turn Reset 900 operations per hour maximum for a Push-Pull Operating Force Flush and extended pushbuttons--with 1NO or 1NC contact: 6.22N (momentary), 7.02N (maintained) Additional contacts--1NO or 1NC: +3.2N (momentary), + 3.3N (maintained) Recommended Terminal Torque 0.8 N m (7.1 in lb.) Applicable Wire Size Minimum 1 x 22 AWG, max. 2 x 14 AWG or 1 x 12 AWG Contact Resistance Initial contact resistance of 50m or less Contact Gap 4mm (NO and NC), 2mm (NO-EM and NC-LB) Horsepower Rating Reference Value: 1/4 HP @ 120V (1o non-reversing), 1HP @ 240V (3o non-reversing) Contact Material Silver (gold plated contacts available - contact IDEC) Operating Temperature Operation: -25 to +50C (without freezing), Storage: -40 to +70C (without freezing) Vibration Resistance 10 to 55Hz, 98m/sec2 (10G) conforming to IEC6068-2-6 Shock Resistance 980m/sec2 (100G) conforming to IEC6068-2-7 Mechanical Life Momentary pushbuttons: 5,000,000 (900 operations per hour), All other switches: 500,000 Conforming to Standards EN60947-1, EN60947-5-1, VDE0660-200, UL508, CSA C22-2 No.14 Approvals (R) File No. E68961 Standards & Approvals Timers Relays & Sockets Signaling Lights Switches & Pilot Devices o22mm - HW Series File No. LR92374 Registration No. R9551089 (E-stops) Registration No. R50054316 (Dual Pushbuttons) Registration No. J9650511 (Pilot Lights) Registration No. J9551458 (all other switches) Electric Shock Protection Class 0 conforming to IEC60536 Degree of Protection (conforming to IEC60529) (conforming to NEMA ICS6-110) IP65 (from front of the panel) IP20 (Type HW-F contact block) NEMA 1, 2, 3, 3R, 3S, 4, 4X, 5, 12, 13 (from front of panel) Pollution Degree (conforming to IEC60947-1) 3 for switches not using a transformer, 2 for switches using a transformer External Short-Circuit Protection 10A 250V fuse conforming to IEC60269-1 Contact Ratings Characteristics Contactors Terminal Referencing Terminal Blocks Certificate No. 2005010305145656 CSA: pushbuttons and selector switches: A600 pilot lights and illuminated pushbuttons, direct supply pilot lights and illuminated pushbuttons with integral transformer (100/110, 115, 120, 200/220, 230, 240, 380, 400/440, 480V) UL: pushbuttons and selector switches: A600 pilot lights and illuminated pushbuttons, direct supply pilot lights and illuminated pushbuttons with integral transformer (100/110, 115, 120, 200/220, 230, 240, 380, 400/440, 480V) TUV: pushbuttons and selector switches: A600=P600 (NO, NC)/Q600 (NO-EM, NC-LB) pilot lights and illuminated pushbuttons, direct supply pilot lights and illuminated pushbuttons with integral transformer (100/110, 115, 120, 200/220, 230, 240, 380, 400/440, 480V) Pushbuttons Illuminated Pushbuttons Selector Switches Illuminated Selector Switches Pushbutton Selectors Conforming to CENELEC EN50005 Contact Block Type HW-C/HW-F /HW-G Rated Insulation Voltage 600V Rated Continuous Current 10A Contact Ratings by Utilization Category IEC 60947-5-1 AC-15 (A600) DC-13 (P600) Operational Voltage Operational Current AC 50/60 Hz DC AC-12 Control of resistive loads & solid state loads 24V 48V 50V 110V 220V 440V 10A -- 10A 10A 6A 2A AC-15 Control of electromagnetic loads (> 72VA) 10A -- 7A 5A 3A 1A DC-12 Control of resistive loads & solid state loads 8A 5A -- 2.2A 1.1A -- DC-13 Control of electromagnets 5A 2A -- 1.1A 0.6A -- Circuit Breakers For dimensions, see page 601. 550 www.IDEC.com Switches & Pilot Devices o22mm - HW Series Switches & Pilot Devices LED Lamp Ratings (LSTD Type) Model LSTD-6k LSTD-1k LSTD-2k LSTD-H2k LSTD-M4k Rated Voltage 6V AC/DC 12V AC/DC 24V AC/DC 120V AC 240V AC Voltage Range 6V AC/DC 10% 12V AC/DC 10% 24V AC/DC 10% 120V AC 5% 240V AC 5% Lamp Base Current Draw BA9S/13 A, R, W: G, S: 17mA 8mA 11mA 11mA 10mA 10mA DC A, R, W: G, S: 14mA 5.5mA 10mA 10mA - - Color Code A (amber), G (green), R (red), S (blue), W (white) Lamp Base Color Same as illumination color Voltage Marking Life (reference value) Die stamped on the base Approx. 50,000 hours (The luminance reduces to 50% the initial intensity when used on complete DC.) A, R, W A, R, W In place of k, specify the Lens/LED Color Code. Relays & Sockets Internal Circuit Signaling Lights AC G, S LED Chip LED Chip LED Chip Protection Diode Protection Protection DiodeDiode Zener Diode Zener Diode Zener Diode Timers Contactors Terminal Blocks Circuit Breakers 800-262-IDEC (4332) * USA & Canada 551 Switches & Pilot Devices Switches & Pilot Devices o22mm - HW Series Relays & Sockets Signaling Lights Non-Illuminated Round Pushbuttons (Assembled) Round Flush Function Contacts Timers Momentary Contactors Maintained Plastic Bezel Terminal Blocks Plastic Bezel Operator Only HW1B-M1-j HW4B-M1-j HW1B-M2-j HW4B-M2-j HW1B-M1F10-j HW4B-M1F10-j HW1B-M2F10-j HW4B-M2F10-j 1NC HW1B-M1F01-j HW4B-M1F01-j HW1B-M2F01-j HW4B-M2F01-j 1NO-1NC HW1B-M1F11-j HW4B-M1F11-j HW1B-M2F11-j HW4B-M2F11-j 2NO HW1B-M1F20-j HW4B-M1F20-j HW1B-M2F20-j HW4B-M2F20-j 2NC HW1B-M1F02-j HW4B-M1F02-j HW1B-M2F02-j HW4B-M2F02-j 2NO-2NC HW1B-M1F22-j HW4B-M1F22-j HW1B-M2F22-j HW4B-M2F22-j Operator Only HW1B-A1-j HW4B-A1-j HW1B-A2-j HW4B-A2-j 1NO HW1B-A1F10-j HW4B-A1F10-j HW1B-A2F10-j HW4B-A2F10-j 1NC HW1B-A1F01-j HW4B-A1F01-j HW1B-A2F01-j HW4B-A2F01-j 1NO-1NC HW1B-A1F11-j HW4B-A1F11-j HW1B-A2F11-j HW4B-A2F11-j 2NO HW1B-A1F20-j HW4B-A1F20-j HW1B-A2F20-j HW4B-A2F20-j 2NC HW1B-A1F02-j HW4B-A1F02-j HW1B-A2F02-j HW4B-A2F02-j 2NO-2NC HW1B-A1F22-j HW4B-A1F22-j HW1B-A2F22-j HW4B-A2F22-j Color Code Black B Green G Red R Blue S White W Yellow Y 1. In place of j, specify the Button Color Code from table below. 2. For nameplates and accessories, see page 596 and 599. 3. For dimensions, see page 601. 4. For contact assembly part numbers, see page 600. 5. All assembled part numbers in catalog include standard, fingersafe (HW-F...) contacts. 6. Assembled units with spring-up terminals (HW-G...) can be ordered by removing an "F" from the part number (Ex. HW1B-M1F11-R becomes HW1B-M111-R). 7. Operator only models include operator plus button. 8. Additional contact configurations available (up to 6 total contacts). N* Circuit Breakers *Gray available for round flush only. 552 Metal Bezel 1NO j Button Color Code Gray Round Extended Metal Bezel www.IDEC.com Switches & Pilot Devices o22mm - HW Series Switches & Pilot Devices Part Number Structure H W 1 B - M 1 F 10 - R Button Colors Bezel 1: Plastic Bezel 4: Metal Bezel Function Contact Arrangement Operator M: Momentary Action A: Maintained Action Terminals 1: Flush 2: Extended 20: 2NO 02: 2NC 22: 2NO-2NC Signaling Lights F: Fingersafe Contacts C: Exposed Screw Terminals blank: Spring-up Terminals 10: 1NO 01: 1NC 11: 1NO-NC B: Black G: Green R: Red S: Blue W: White Y: Yellow N: Gray* *Available for round flush only Non-Illuminated Round Pushbuttons (Replacement Parts) + Mounting Adaptor + Safety Lever Lock Contacts Spring-Up Terminal Anti-Rotation Ring 1NO 1NC HW-F10 HW-F01 HW-F10R (early make) HW-F01R (late break) HW-G10 HW-G01 HW-G10R (early make) HW-G01R (late break) HW-C10 HW-C01 HW-C10R (early make) HW-C01R (late break) Dummy Block Part Number Completed Unit Style Part Number HW9Z-RL HW1A-B1-j Use with notched panel cutout to prevent unit rotation. Round Extended Operators HW1A-B2-j Plastic Bezel Style Round Flush/ Extended Metal Bezel 1. In place of j, specify the Button Color Code from table. HW1B-M0 HW4B-MO j Button Color Code HW1B-A0 Safety Lever Lock Style HW4B-AO Color Code Color Code Black B White W Green G Yellow Y Red R Gray N* Blue S Terminal Blocks Part Number *Gray available for round flush only. Part Number HW9Z-LS 800-262-IDEC (4332) * USA & Canada Circuit Breakers 1. Used to mount contact blocks to operator. 2. IDEC strongly recommends using the safety lever lock to prevent heavy vibration or maintenance personnel from inadvertently unlocking contacts. = Round Flush TW-DB HW-CB2C Button Buttons Style Contact Block Mounting Adaptor Style + Contactors Exposed Screw Terminal Operator Timers Standard Fingersafe (IP20) + Maintained Style Anti-Rotation Ring Relays & Sockets Contact Blocks + Momentary Contact Blocks 553 Switches & Pilot Devices Switches & Pilot Devices o22mm - HW Series Relays & Sockets Signaling Lights Non-Illuminated Mushroom Head Pushbuttons (Assembled) o29mm Mushroom Head Function Timers Momentary Contactors Maintained o40mm Mushroom Head Contacts Plastic Bezel Metal Bezel Plastic Bezel Metal Bezel Operator Only HW1B-M3-j HW4B-M3-j HW1B-M4-j HW4B-M4-j 1NO HW1B-M3F10-j HW4B-M3F10-j HW1B-M4F10-j HW4B-M4F10-j 1NC HW1B-M3F01-j HW4B-M3F01-j HW1B-M4F01-j HW4B-M4F01-j 1NO-1NC HW1B-M3F11-j HW4B-M3F11-j HW1B-M4F11-j HW4B-M4F11-j 2NO HW1B-M3F20-j HW4B-M3F20-j HW1B-M4F20-j HW4B-M4F20-j 2NC HW1B-M3F02-j HW4B-M3F02-j HW1B-M4F02-j HW4B-M4F02-j 2NO-2NC HW1B-M3F22-j HW4B-M3F22-j HW1B-M4F22-j HW4B-M4F22-j Operator Only HW1B-A3-j HW4B-A3-j HW1B-A4-j HW4B-A4-j 1NO HW1B-A3F10-j HW4B-A3F10-j HW1B-A4F10-j HW4B-A4F10-j 1NC HW1B-A3F01-j HW4B-A3F01-j HW1B-A4F01-j HW4B-A4F01-j 1NO-1NC HW1B-A3F11-j HW4B-A3F11-j HW1B-A4F11-j HW4B-A4F11-j 2NO HW1B-A3F20-j HW4B-A3F20-j HW1B-A4F20-j HW4B-A4F20-j 2NC HW1B-A3F02-j HW4B-A3F02-j HW1B-A4F02-j HW4B-A4F02-j 2NO-2NC HW1B-A3F22-j HW4B-A3F22-j HW1B-A4F22-j HW4B-A4F22-j Terminal Blocks j Button Color Code Function Circuit Breakers Momentary 554 Color Code o60mm Mushroom Head Black B Contacts Plastic Bezel Green G Operator Only HW1B-M5-j* Red R 1NO HW1B-M5F10-j* Blue S 1NC HW1B-M5F01-j* White W 1NO-1NC HW1B-M5F11-j* 2NO HW1B-M5F20-j* Yellow Y 2NC HW1B-M5F02-j* 2NO-2NC HW1B-M5F22-j* www.IDEC.com 1. In place of j, specify the Button Color Code from table. 2. *60mm mushroom available only in red, green, black, and yellow. 3. For nameplates and accessories, see page 596 and 599. 4. For dimensions, see page 601. 5. For contact assembly part numbers, see page 600. 6. All assembled part numbers in catalog include standard fingersafe (HW-F...) contacts. 7. Assembled units with spring-up terminals (HW-G...) can be ordered by removing an "F" from the part number (Ex. HW1B-M1F11-R becomes HW1B-M111-R). 8. Units with exposed screw terminals (HW-C...) must be ordered as sub-components. 9. Operator only models include operator plus button. 10. Additional contact configurations available (up to 6 total contacts). Switches & Pilot Devices o22mm - HW Series Switches & Pilot Devices Part Number Structure H W 1 B - M 3 F 10 - R Button Colors Bezel 1: Plastic Bezel 4: Metal Bezel Function Contact Arrangement Operator M: Momentary Action A: Maintained Action (Not available for 60mm mushroom) Terminals F: Fingersafe Contacts C: Exposed Screw Terminals blank: Spring-up Terminals 10: 1NO 01: 1NC 11: 1NO-NC 20: 2NO 02: 2NC 22: 2NO-2NC Signaling Lights 3: o29mm Mushroom 4: o40mm Mushroom 5: o60mm Mushroom (Not available for 60mm jumbo mushroom pushbutton.) B: Black G: Green R: Red S: Blue W: White Y: Yellow Non-Illuminated Mushroom Head Pushbuttons (Replacement Parts) + Mounting Adaptor + Safety Lever Lock Style Contacts Standard Fingersafe (IP20) Operator + Button Safety Lever Lock 1NO 1NC HW-F10 HW-F01 HW-F10R (early make) HW-F01R (late break) HW-G10 HW-G01 HW-G10R (early make) HW-G01R (late break) HW-C10 HW-C01 HW-C10R (early make) Dummy Block HW-C01R (late break) TW-DB Style Part Number Style HW9Z-LS o29mm Mushroom Cap Part Number HW1A-B3-j Anti-Rotation Ring Appearance Part Number o40mm Mushroom Cap HW9Z-RL HW1A-B4-j Operators Style Plastic Bezel o29mm Mushroom o40mm Mushroom HW1B-M0L Metal Bezel HW4B-MOL Maintained O60mm Jumbo Mushroom Momentary HW-CB2C HW1B-A0L HW1B-M5-j* HW4B-AOL 1. In place of j, specify the Button Color Code from table. j Button Color Code Color Code Color Code Black B Blue S Green G White W R Yellow Y Red Terminal Blocks Part Number HW1B-M5 available only in black, red, green and yellow. - Circuit Breakers 1. Used to mount contact blocks to operator. 2. IDEC strongly recommends using the safety lever lock to prevent heavy vibration or maintenance personnel from inadvertently unlocking contacts. Completed Unit Buttons Contact Block Mounting Adaptor Style = Contactors Exposed Screw Terminal + Timers Spring-Up Terminal Anti-Rotation Ring Relays & Sockets Contact Blocks + Momentary Contact Blocks 1. *60mm mushroom operator includes non-removable button (available in red, black, green and yellow only). 2. For nameplates and accessories, see page 596 and 599. 3. For dimensions, see page 601. 800-262-IDEC (4332) * USA & Canada 555 Switches & Pilot Devices Switches & Pilot Devices o22mm - HW Series Relays & Sockets Signaling Lights Non-Illuminated Square Pushbuttons (Assembled) Function Timers Momentary Maintained Square Extended Plastic Bezel Plastic Bezel Operator Only HW2B-M1-j HW2B-M2-j 1NO HW2B-M1F10-j HW2B-M2F10-j 1NC HW2B-M1F01-j HW2B-M2F01-j 1NO-1NC HW2B-M1F11-j HW2B-M2F11-j 2NO HW2B-M1F20-j HW2B-M2F20-j 2NC HW2B-M1F02-j HW2B-M2F02-j 2NO-2NC HW2B-M1F22-j HW2B-M2F22-j Operator Only HW2B-A1-j HW2B-A2-j 1NO HW2B-A1F10-j HW2B-A2F10-j 1NC HW2B-A1F01-j HW2B-A2F01-j 1NO-1NC HW2B-A1F11-j HW2B-A2F11-j 2NO HW2B-A1F20-j HW2B-A2F20-j 2NC HW2B-A1F02-j HW2B-A2F02-j 2NO-2NC HW2B-A1F22-j HW2B-A2F22-j j Button Color Code Color Code Black B Green G Red R Blue S White W Yellow Y 1. In place of j, specify the Button Color Code from table. 2. For nameplates and accessories, see page 596 and 599. 3. For dimensions, see page 601. 4. For contact assembly part numbers, see page 600. 5. Square pushbuttons available in plastic bezel only. 6. All assembled part numbers in catalog include standard fingersafe (HW-F...) contacts. 7. Assembled units with spring-up terminals (HW-G...) can be ordered by removing an "F" from the part number (Ex. HW2B-M1F11-R becomes HW1B-M111-R). 8. Units with exposed screw terminals (HW-C...) must be ordered as sub-components. 9. Operator only model includes operator and button. 10. Additional contact configurations available (up to 6 total contacts). Circuit Breakers Terminal Blocks Contactors Square Flush Contacts 556 www.IDEC.com Switches & Pilot Devices o22mm - HW Series Switches & Pilot Devices Part Number Structure H W 2 B - M 1 F 10 - R Button Colors Function M: Momentary Action A: Maintained Action Contact Arrangement Operator 1: Flush 2: Extended 10: 1NO 01: 1NC 11: 1NO-NC Terminals Signaling Lights F: Fingersafe Contacts C: Exposed Screw Terminals blank: Spring-up Terminals 20: 2NO 02: 2NC 22: 2NO-2NC B: Black G: Green R: Red S: Blue W: White Y: Yellow Non-Illuminated Square Pushbuttons (Replacement Parts) Contact Blocks Mounting Adaptor + + Safety Lever Lock + Anti-Rotation Ring + Operator + Button = Completed Unit Relays & Sockets Contact Blocks Style Contacts Spring-Up Terminal 1NO 1NC HW-F10 HW-F01 HW-F10R (early make) HW-F01R (late break) HW-G10 HW-G01 HW-G10R (early make) HW-G01R (late break) Style Buttons Part Number Style Part Number Square Flush HW9Z-LS HW2A-B1-j Anti-Rotation Ring Appearance Part Number Square Extended HW2A-B2-j HW9Z-RL HW-C10 HW-C01 HW-C10R (early make) HW-C01R (late break) Style Part Number Plastic Bezel Style Square Flush Extended HW-CB2C HW2B-A0 j Button Color Code Color Code Color Code Black B Blue S Green G White W Red R Yellow Y 2. For nameplates and accessories, see pages 596 and 599. 3. For dimensions, see page 601. 800-262-IDEC (4332) * USA & Canada Circuit Breakers 1. Used to mount contact blocks to operator. 2. IDEC strongly recommends using the safety lever lock to prevent heavy vibration or maintenance personnel from inadvertently unlocking contacts. HW2B-M0 1. In place of j, specify the Button Color Code from table. Terminal Blocks Contact Block Mounting Adaptor Operators Momentary TW-DB Maintained Dummy Block Use with notched panel cutout to prevent unit rotation. Contactors Exposed Screw Terminal Timers Standard Fingersafe (IP20) Safety Lever Lock 557 Switches & Pilot Devices Switches & Pilot Devices o22mm - HW Series O29mm Head Pushlock Turn Reset O40mm Head Pushlock Turn Reset Contacts Plastic Bezel Metal Bezel Plastic Bezel Metal Bezel Operator Only HW1B-V3j HW4B-V3j HW1B-V4j HW4B-V4j 1NO HW1B-V3F10-j HW4B-V3F10-j HW1B-V4F10-j HW4B-V4F10-j 1NC HW1B-V3F01-j HW4B-V3F01-j HW1B-V4F01-j HW4B-V4F01-j 1NO-1NC HW1B-V3F11-j HW4B-V3F11-j HW1B-V4F11-j HW4B-V4F11-j 2NO HW1B-V3F20-j HW4B-V3F20-j HW1B-V4F20-j HW4B-V4F20-j 2NC HW1B-V3F02-j HW4B-V3F02-j HW1B-V4F02-j HW4B-V4F02-j Timers Relays & Sockets Signaling Lights Non-Illuminated E-Stop Pushbuttons (Assembled) Contacts Plastic Bezel Metal Bezel Plastic Bezel Metal Bezel HW1B-V4R-EMO-2* HW4B-V4R-EMO-2* HW1B-X4R* HW4B-X4R* 1NO HW1B-V4F10-R-EMO-2* HW4B-V4F10-R-EMO-2* HW1B-X4F10-R* HW4B-X4F10-R* 1NC HW1B-V4F01-R-EMO-2* HW4B-V4F01-R-EMO-2* HW1B-X4F01-R* HW4B-X4F01-R* 1NO-1NC HW1B-V4F11-R-EMO-2* HW4B-V4F11-R-EMO-2* HW1B-X4F11-R* HW4B-X4F11-R* 2NO HW1B-V4F20-R-EMO-2* HW4B-V4F20-R-EMO-2* HW1B-X4F20-R* HW4B-X4F20-R* 2NC HW1B-V4F02-R-EMO-2* HW4B-V4F02-R-EMO-2* HW1B-X4F02-R* HW4B-X4F02-R* o60mm Head Pushlock Turn Reset Circuit Breakers O40mm Head Pushlock Key Reset Operator Only Terminal Blocks Contactors O40mm Head EMO Pushlock Turn Reset Contacts Plastic Bezel Operator Only HW1B-V5R* 1NO HW1B-V5F10-R* 1NC HW1B-V5F01-R* 1NO-1NC HW1B-V5F11-R* 2NO HW1B-V5F20-R* 2NC HW1B-V5F02-R* 558 1. * Available in Red only. 2. Available in red or yellow. Insert color code in place of j (R: Red, Y: Yellow). 2. For accessories, see page 599. 3. For dimensions, see page 601. 5. For nameplates and shrouds, see page 600. 4. For contact assembly part numbers, see page 600. 7. All HW series E-stops comply with EN60947-5-5, the IEC "E-Stop Addendum to the Low Voltage Directive," this includes "tamper proof" operation whereby a change of contact state is not possible by "teasing" or "floating" the operator. 8. All assembled part numbers in catalog include standard fingersafe (HW-F...) contacts. 9. Assembled units with spring-up terminals (HW-G...) can be ordered by removing an "F" from the part number (Ex. HW1B-M1F11-R becomes HW1B-M111-R). 10. Units with exposed screw terminals (HW-C...) must be ordered as sub-components. 11. Operator only models include operator and button. 12. Additional contact configurations available (up to 6 total contacts). www.IDEC.com Switches & Pilot Devices o22mm - HW Series H W 1 B - V 3 F 10 - R - EMO-2 Engraved Button* Bezel EMO-2: EMO switch 1: Plastic Bezel 4: Metal Bezel Function V: Pushlock Turn Reset X: Pushlock Key Reset (not available for 60mm jumbo mushroom) *Option available for red EMO E-Stop only Operator Button Colors Contact Arrangement Terminals F: Fingersafe C: Exposed Screw blank: Springup 10: 1NO 01: 1NC 11: 1NO-NC R: Red Y: Yellow 20: 2NO 02: 2NC 22: 2NO-2NC Note: some switches only available in red. Signaling Lights 3: o29mm Head 4: o40mm Head 5: o60mm Head Non-Illuminated E-Stop Pushbuttons (Replacement Parts) Contact Blocks + Mounting Adaptor + Style + Standard Fingersafe (IP20) HW-F10 HW-F01 HW-F10R (early make) HW-F01R (late break) HW-G10 HW-G01 HW-G10R (early make) HW-G01R (late break) HW-C10 HW-C01 HW-C10R (early make) HW-C01R (late break) Dummy Block Style = Completed Unit Anti-Rotation Ring Part Number Appearance HW9Z-LS Part Number HW9Z-RL Use with notched panel cutout to prevent unit rotation. Operators Style Plastic o29mm Head Pushlock Turn Reset o40mm Head Pushlock Turn Reset TW-DB Metal red HW1B-V3R HW4B-V3R yellow HW1B-V3Y HW4B-V3Y red HW1B-V4R HW4B-V4R yellow HW1B-V4Y HW4B-V4Y Contactors 1NC Operator Timers 1NO Exposed Screw Terminal Anti-Rotation Ring Safety Lever Lock Contacts Spring-Up Terminal + Relays & Sockets Contact Blocks Safety Lever Lock Switches & Pilot Devices Part Number Structure o40mm Head EMO Pushlock Turn Reset* Contact Block Mounting Adaptor Part Number HW1B-V4R-EMO-2 HW4B-V4R-EMO-2 HW1B-X4R HW4B-X4R HW1B-V5R - Terminal Blocks Style o40mm Head Pushlock Key Reset* HW-CB2C o60mm Head Pushlock Turn Reset* Circuit Breakers 1. Used to mount contact blocks to operator. 2. IDEC strongly recommends using the safety lever lock to prevent heavy vibration or maintenance personnel from inadvertently unlocking contacts. 1. *Available in red only. 2. All E-Stop buttons are not removable from the operator. 800-262-IDEC (4332) * USA & Canada 559 Switches & Pilot Devices Switches & Pilot Devices o22mm - HW Series Relays & Sockets Signaling Lights Push Pull & Unibody E-Stop Pushbuttons (Assembled) o40mm Unibody Pushlock Turn Reset* o40mm Head Push-Pull Timers Contacts Plastic Bezel Metal Bezel Contacts Plastic Bezel HW1E-BV4F11-R Operator Only (Red) HW1B-Y2R HW4B-Y2R 1NO-1NC Operator Only (Yellow) HW1B-Y2Y HW4B-Y2Y 2NC HW1E-BV4F02-R 1NO HW1B-Y2F10-j HW4B-Y2F10-j 1NC HW1B-Y2F01-j HW4B-Y2F01-j 1NO-2NC HW1E-BV412R-TK2093-1 1NO-1NC HW1B-Y2F11-j HW4B-Y2F11-j 2NC HW1B-Y2F02-j HW4B-Y2F02-j 2NO HW1B-Y2F20-j HW4B-Y2F20-j l Full Voltage Code Unibody Illuminated E-Stops* Contactors Contacts LED Incandescent 1NO-1NC HW1E-LV4F11QD-R-l HW1E-LV4F11Q-R-l 2NC HW1E-LV4F02QD-R-l HW1E-LV4F02Q-R-l 2NC (with push-on illumination) HW1E-TV4F02QD-R-l HW1E-TV4F11Q-R-l 1NO-1NC (with push-on illumination ) HW1E-TV4F11QD-R-l HW1E-TV4F02Q-R-l Terminal Numbering (Unibody only) Voltage Code 6VAC/DC 6V Models Terminal Number 12VAC/DC 12V 1NO-1NC NO = 13/14, NC = 11/12 24VAC/DC 24V 2NC NC = 11/12, NC = 21/22 120V AC* 120V Lamp + = X2, Lamp - = X1 240V AC* 240V HW1E-L HW1E-T *LED only. Circuit Breakers Terminal Blocks 1. * Available in Red only. 2. Available in red or yellow. Insert color code in place of j (R: Red, Y: Yellow). 3. In place of l, specify Full Voltage Code. 4. With single unit construction, the positive action contacts are integrated in the body of the switch. This provides an extra degree of safety and reliability for critical emergency stop functions. 5. In the illuminated version, the light is independent of the switch action (except push-on LED model). 6. For accessories, see page 599. 7. For dimensions, see page 601. 8. For nameplates and shrouds, see page 599. 9. For contact assembly part numbers, see page 599. 10. All HW Series E-Stop operators include non-removable color caps. 11. All HW series E-Stops comply with EN60947-5-5, the IEC "E-Stop Addendum to the Low Voltage Directive," this includes "tamper proof" operation whereby a change of contact state is not possible by "teasing" or "floating" the operator. 12. All HW series E-Stop switches comply with SEMI S2 standards. 13. All assembled part numbers in catalog include standard fingersafe (HW-F...) contacts. 14. Assembled units with spring-up terminals (HW-G...) can be ordered by removing an "F" from the part number (Ex. HW1B-M1F11-R becomes HW1B-M111-R). 15. Units with exposed screw terminals (HW-C...) must be ordered as sub-components. 16. Additional contact configurations available (up to 6 total contacts). 560 www.IDEC.com Switches & Pilot Devices o22mm - HW Series H W 1 E - LV4 F 11 - Q D R - 24V Full Voltage Code Button Colors (Illuminated E-Stop) Bezel 1: Plastic Bezel 4: Metal Bezel* (*not available for HW1E unibody) Function Lamp Code B: Push Pull E: Pushlock Turn Reset D: LED blank: Incandescent Illumination Contacts 11: 1NO-1NC 02: 2NC 10: 1NO 20: 2NO 6V: 6V AC/DC 12V: 12V AC/DC 24V: 24V AC/DC 120V: 120VC AC* 240V: 240V AC* (*only available in 40mm Push Pull E-Stop) Illumination Circuit *LED only Signaling Lights BV4: Non-illuminated (unibody style) LV4: Illuminated TV4: Illuminated Push On Y2: Non-illuminated Push Pull E-Stop R: Red Y: Yellow* Switches & Pilot Devices Part Number Structure blank: 40mm Push Pull & Non-illuminated Unibody E-Stop Q: Illuminated Unibody E-Stop Illuminated & Non-Illuminated E-Stop Pushbuttons (Replacement Parts) Mounting Adaptor + Contact Blocks Style Operator Standard Fingersafe (IP20) HW-F10 HW-F01 HW-F10R (early make) HW-F01R (late break) HW-G10 HW-G01 HW-G10R (early make) HW-G01R (late break) HW-C10 HW-C01 Style Part Number HW-C01R (late break) Completed Unit Anti-Rotation Ring Appearance Part Number HW9Z-RL HW-CB2C Use with notched panel cutout to prevent unit rotation. 1. Used to mount contact blocks to operator. 2. IDEC strongly recommends using the safety lever lock to prevent heavy vibration or maintenance personnel from inadvertently unlocking contacts. Safety Lever Lock HW-C10R (early make) = Style Operators Style Part Number o40mm Head Push-Pull Plastic HW1B-Y2R Part Number Metal HW4B-Y2R HW9Z-LS Plastic HW1B-Y2Y TW-DB HW4B-Y2Y Terminal Blocks Metal 1. There are no replacement parts for the HW1E unibody E-Stop. 2. For illuminated unibody E-Stop, see page 600 for replacement lens. Contactors 1NC Dummy Block + Timers 1NO Exposed Screw Terminal Anti-Rotation Ring Contact Block Mounting Adaptor Contacts Spring-Up Terminal + Relays & Sockets Safety Lever Lock red + yellow Contact Blocks All E- Stop Buttons are not removable from the operator. Circuit Breakers 800-262-IDEC (4332) * USA & Canada 561 Switches & Pilot Devices Switches & Pilot Devices o22mm - HW Series Relays & Sockets Signaling Lights E-Stop Stations 29mm Pushlock Turn Reset 40mm Pushlock Turn Reset Plastic Bezel Metal Bezel Plastic Bezel Metal Bezel 1NO-1NC FB1W-HW1B-V311R FB1W-HW4B-V311R FB1W-HW1B-V411R FB1W-HW4B-V411R 2NC FB1W-HW1B-V302R FB1W-HW4B-V302R FB1W-HW1B-V402R FB1W-HW4B-V402R Contacts Plastic Bezel Metal Bezel Plastic Bezel Metal Bezel 1NO-1NC FB1W-HW1B-Y211R FB1W-HW4B-Y211R FB1W-HW1B-X411R FB1W-HW4B-X411R 2NC FB1W-HW1B-Y202R FB1W-HW4B-Y202R FB1W-HW1B-X402R FB1W-HW4B-X402R Timers Contacts Terminal Blocks Contactors 40mm Push-Pull Reset 40mm Pushlock Key Reset 40mm EMO Pushlock Turn Reset Contacts Plastic Bezel Metal Bezel 1NO-1NC FB1W-HW1B-V411R-EMO-2 FB1W-HW4B-V411R-EMO-2 2NC FB1W-HW1B-V402R-EMO-2 FB1W-HW4B-V402R-EMO-2 Circuit Breakers 1. Maximum of two contact blocks. 2. Box is supplied with yellow top and black bottom only. 562 www.IDEC.com Switches & Pilot Devices o22mm - HW Series Switches & Pilot Devices Jumbo Dome Pilot Lights (Assembled) Plastic Bezel HW1P-5Q0 Full Voltage 24V AC/DC HW1P-5Q4-k Operator Only HW1P-5Q7* Full Voltage 24V AC/DC HW1P-5Q7-k Actual Size Signaling Lights Operator Only Jumbo Dome LED Incandescent Relays & Sockets 1. 2. 3. 4. 5. In place of k, specify the Lens/LED Color Code. *Incandescent operator comes with bulb. Available with spring-up terminals in 24V only. For nameplates and accessories, see page 596 and 599. For dimensions, see page 601. k Lens/LED Color Code Code Amber A Green G Red R Blue S White W Yellow Y Timers Color Item Appearance Description Contactors Jumbo Dome Replacement Parts Part Number Lens HW1A-P5k Polycarbonate Lens LED Diffusing Lens* HW9Z-PP5C Terminal Blocks LED Lamps Jumbo Dome LED Lamp LSTDB-2k 1. In place of k, specify the Lens/LED Color Code. 2. *Diffusing lens for LED models only. 3. Use white LED for yellow lens. Lamp Ratings LED LSTDB-2 Incandescent LSB-2 Operating Voltage 24V AC/DC 10% Rated Current Power Consumption 15mA 0.36W 150mA 3.6W 800-262-IDEC (4332) * USA & Canada Circuit Breakers Part Number 563 Switches & Pilot Devices Switches & Pilot Devices o22mm - HW Series Signaling Lights Pilot Lights (Assembled) Relays & Sockets Round Flush Dome Plastic Bezel Metal Bezel Plastic Bezel Metal Bezel Operator Only HW1P-1FQ0-k HW4P-1FQ0-k HW1P-2FQ0-k HW4P-2FQ0-k Full Voltage HW1P-1FQm-k-l HW4P-1FQm-k-l HW1P-2FQm-k-l HW4P-2FQm-k-l 120V AC HW1P-1FH2m-k HW4P-1FH2m-k HW1P-2FH2m-k HW4P-2FH2m-k 240V AC HW1P-1FM4m-k HW4P-1FM4m-k HW1P-2FM4m-k HW4P-2FM4m-k 480V AC HW1P-1FT8m-k HW4P-1FT8m-k HW1P-2FT8m-k HW4P-2FT8m-k 110V DC HW1P-1D2D-k - HW1P-2D2D-k - Transformer Timers DC-DC Converter* Square Flush Contactors Plastic Bezel Operator Only HW2P-1FQ0-k Full Voltage HW2P-1FQm-k-l Transformer DC-DC Converter* 120V AC HW2P-1FH2m-k 240V AC HW2P-1FM4m-k 480V AC HW2P-1FT8m-k 110V DC HW2P-1D2D-k l Full Voltage Code m Lamp Type Code Color Code Voltage Code Lamp Code Amber A 6VAC/DC 6V Incandescent Blank Green G 12VAC/DC 12V LED D Red R 24VAC/DC 24V Blue S 120V AC (LED only) 120V White W 240V AC (LED only) 240V Yellow Y Circuit Breakers Terminal Blocks k Lens/LED Color Code 564 www.IDEC.com 1. In place of k, specify the Lens/LED Color Code from table below. 2. In place of lspecify the Full Voltage Code from table below. 3. In place of m specify Lamp Type Code from table below. 4. *DC-DC convertor voltage input from 90-140V DC, comes with spring-up terminals only. 5. DC-DC converter models with LED lamps only. 6. For nameplates and accessories, see page 596 and 599. 7. For dimensions, see page 601. 8. Pilot lights do not come with anti-rotation ring. 9. Operator models come with operator and lens. 10. Yellow pilot light comes with white LED. Switches & Pilot Devices o22mm - HW Series Switches & Pilot Devices Part Number Structure H W 1 P - 2 F Q D - R - 12V Lamp Voltage Bezel 1: Round Plastic 2: Square Plastic 4: Round Metal Operator 1: Flush 2: Dome Illumination Circuit Lens/LED Colors Q: Full Voltage H2: 120V AC Transformer M4: 240V AC Transformer T8: 480V AC Transformer D2: DC-DC Converter A: Amber G: Green R: Red S: Blue W: White Y: Yellow Lamp Type Code D: LED Blank: Incandescent Signaling Lights (full voltage units only) 6V: 6V AC/DC 12V: 12V AC/DC 24V: 24V AC/DC 120V: 120V AC* 240V: 240V AC* *LED only Pilot Lights (Replacement Parts) Transformer* + Lamp + Operator + Lens = Completed Unit Relays & Sockets (not applicable for full voltage units) Transformer Units Style LED/Incandescent Voltage Part Number 120V AC HW-FH20 HW-MH20* 240V AC HW-FM40 HW-MM40* 480V AC HW-FT80 HW-RT80* 110V DC** Style Type Plastic Bezel Metal Bezel Round Flush Standard HW1P-1FQ0 HW4P-1FQ0 Full Voltage Transformer Dome Full Voltage HW-RD0* 1. *With spring-up terminals - to use spring-up terminal type, must use transformer type operator designed for spring-up transformer. 2. ** DC-DC converter voltage input from 90-140V DC. Transformer Square Flush Full Voltage Lamps Voltage LED Incandescent Part Number 6V AC/DC LSTD-6k 12V AC/DC LSTD-1k 24V AC/DC LSTD-2k 120V AC LSTD-H2k 240V AC LSTD-M4k 6V AC/DC IS-6 IS-12 24V AC/DC IS-24 1. In place of k, specify the LED Color Code. 2. The LED contains a current-limiting resistor and reverse polarity protection diodes. Spring-up Terminals HW1P-100 - Standard HW1P-2FQ0 HW4P-2FQ0 Spring-up Terminals HW1P-2Q0 HW4P-2Q0 Standard HW1P-20 HW4P-20 Spring-up Terminals HW1P-200 - Standard HW2P-1FQ0 - Spring-up Terminals HW2P-1Q0 Standard HW2P-10 - Spring-up Terminals HW2P-100 - Lenses Style l Lens Color Code Part Number Round/ Flush Dome HW1A-P1-l HW1A-P2-l Color Code Amber A Green G Red R Blue S White W Yellow Y For yellow lens use white LED. Code Color Code Amber A Blue S Green G White W Square/ Flush HW2A-P1-l Circuit Breakers Color R HW4P-10 1. Transformer type requires separate transformer & lamp. Must select correct transformer bases on standard or spring up terminal type. Use 6V lamps or LEDs. 2. Full voltage type only requires lamp. k LED Color Code Red HW4P-1Q0 HW1P-10 Terminal Blocks 12V AC/DC Transformer HW1P-1Q0 Standard Contactors Style Spring-up Terminals Timers (6V secondary voltage) Operators In place of l, specify the Lens Color Code. For yellow lens use white LED. 800-262-IDEC (4332) * USA & Canada 565 Switches & Pilot Devices Illuminated Round Pushbuttons (Assembled) Illuminated Full Voltage Pushbuttons Flush Extended Extended w/ Full Shroud Plastic Bezel Metal Bezel Plastic Bezel Metal Bezel Plastic Bezel Metal Bezel Momentary Contacts Operator Only 1NO 1NC 1NO-1NC 2NO HW1L-M1-k HW1L-M1F10Qm-k-l HW1L-M1F01Qm-k-l HW1L-M1F11Qm-k-l HW1L-M1F20Qm-k-l HW4L-M1-k HW4L-M1F10Qm-k-l HW4L-M1F01Qm-k-l HW4L-M1F11Qm-k-l HW4L-M1F20Qm-k-l HW1L-M2-k HW1L-M2F10Qm-k-l HW1L-M2F01Qm-k-l HW1L-M2F11Qm-k-l HW1L-M2F20Qm-k-l HW4L-M2-k HW4L-M2F10Qm-k-l HW4L-M2F01Qm-k-l HW4L-M2F11Qm-k-l HW4L-M2F20Qm-k-l HW1L-MF2-k HW1L-MF2F10Qm-k-l HW1L-MF2F01Qm-k-l HW1L-MF2F11Qm-k-l HW1L-MF2F20Qm-k-l HW4L-MF2-k HW4L-MF2F10Qm-k-l HW4L-MF2F01Qm-k-l HW4L-MF2F11Qm-k-l HW4L-MF2F20Qm-k-l Maintained Timers Relays & Sockets Signaling Lights Switches & Pilot Devices o22mm - HW Series Operator Only 1NO 1NC 1NO-1NC 2NO HW1L-A1-k HW1L-A1F10Qm-k-l HW1L-A1F01Qm-k-l HW1L-A1F11Qm-k-l HW1L-A1F20Qm-k-l HW4L-A1-k HW4L-A1F10Qm-k-l HW4L-A1F01Qm-k-l HW4L-A1F11Qm-k-l HW4L-A1F20Qm-k-l HW1L-A2-k HW1L-A2F10Qm-k-l HW1L-A2F01Qm-k-l HW1L-A2F11Qm-k-l HW1L-A2F20Qm-k-l HW4L-A2-k HW4L-A2F10Qm-k-l HW4L-A2F01Qm-k-l HW4L-A2F11Qm-k-l HW4L-A2F20Qm-k-l HW1L-AF2-k HW1L-AF2F10Qm-k-l HW1L-AF2F01Qm-k-l HW1L-AF2F11Qm-k-l HW1L-AF2F20Qm-k-l HW4L-AF2-k HW4L-AF2F10Qm-k-l HW4L-AF2F01Qm-k-l HW4L-AF2F11Qm-k-l HW4L-AF2F20Qm-k-l Contactors Illuminated Transformer Pushbuttons Terminal Blocks Metal Bezel Operator Only 1NO-1NC 2NO HW1L-M1-k HW1L-M1F11lm-k HW1L-M1F20lm-k HW4L-M1-k HW4L-M1F11lm-k HW4L-M1F20lm-k HW1L-M2-k HW1L-M2F11lm-k HW1L-M2F20lm-k HW4L-M2-k HW4L-M2F11lm-k HW4L-M2F20lm-k HW1L-MF2-k HW4L-MF2-k HW1L-MF2F11lm-k HW4L-MF2F11lm-k HW1L-MF2F20lm-k HW4L-MF2F20lm-k Operator Only 1NO-1NC 2NO HW1L-A1-k HW1L-A1F11lm-k HW1L-A1F20lm-k HW4L-A1-k HW4L-A1F11lm-k HW4L-A1F20lm-k HW1L-A2-k HW1L-A2F11lm-k HW1L-A2F20lm-k HW4L-A2-k HW4L-A2F11lm-k HW4L-A2F20lm-k HW1L-AF2-k HW1L-AF2F11lm-k HW1L-AF2F20lm-k 2. In place of lspecify Voltage Code from table. In place of m specify Lamp Code from table. Light independent of switch position. For replacement part numbers, see page 567. For nameplates and accessories, see page 596. and 599. 7. For dimensions, see page 601. 8. For contact assembly part numbers, see page 600. 9. Full voltage and transformer models use the same operator. 10. Additional contact configurations available (up to 6 total contacts). 11. Yellow pushbutton comes with white LED. 3. 4. 5. 6. Circuit Breakers Extended w/ Full Shroud Plastic Bezel 1. In place of k, specify Lens/LED Color Code from table. 566 Extended Metal Bezel Momentary Flush Plastic Bezel Maintained Contacts k Lens/LED Color Code Color Code Amber A Green G Red R Blue S White W Yellow l Voltage Code Y Transformer Models Voltage Code Voltage Code 6V AC/DC 6V 120V AC H2 12V AC/DC 12V 240V AC M4 24V AC/DC 24V 480V AC T8 120V AC (LED only) 120V 240V AC (LED only) 240V www.IDEC.com Metal Bezel HW4L-AF2-k HW4L-AF2F11lm-k HW4L-AF2F20lm-k m Lamp Code Full Voltage Models Yellow LED not available. Use white LED for yellow lens. Plastic Bezel Lamp Code Incandescent Blank LED D Switches & Pilot Devices W 1 Switches & Pilot Devices H o22mm - HW Series Part Number Structure - M F2 F 10 Q D - G - 12V L Lamp Voltage Bezel 1: Plastic 4: Metal Function M: Momentary A: Maintained Lens Color Operator 1F: Flush 2F: Extended F2: Extended w/ shroud A: Amber S: Blue G: Green W: White R: Red Y: Yellow Contact Arrangement Illumination Circuit Q: Full Voltage H2: Transformer 120V AC M4: Transformer 240V AC T8: Transformer 480V AC Lamp Code *LED only D: LED Blank: Incandescent Signaling Lights 10: 1NO 01: 1NC 11: 1NO-1NC 20: 2NO (full voltage units only) 6V: 6V AC/DC 12V: 12V AC/DC 24V: 24V AC/DC 120V: 120VC AC* 240V: 240V AC* Illuminated Round Pushbuttons (Replacement Parts) Transformer* + Contact Blocks + Lead Holder + Mounting Adaptor + Safety Lever Lock + Lamp + Anti-Rotation Ring + Operator + Lens Completed Unit = Relays & Sockets *Transformer not needed with full voltage models. Lamp Circuit Components Contact Blocks Style Description Lead Holder For use with HW-CBL on all illuminated pushbutton units. One required for each deck (pair) of contacts. Full Voltage Adaptor Exposed HW-DA1B Spring Up HW-GA1 Fingersafe TW-DA1FB Exposed TW-DA1B 120VAC 240VAC 480VAC Fingersafe TW-F126B TW-F246B TW-F486B 120V 240V 480V Spring Up HW-T126 HW-T246 HW-L486 Exposed TW-T126B TW-T246B TW-T486B For use with even number of contacts. 110VDC Operators Metal Bezel Momentary HW1L-M0 HW4L-M0 Round Flush/ Extended Maintained HW1L-A0 HW4L-A0 Momentary HW1L-MF0 HW4L-MF0 Extended with Full Shroud Maintained HW1L-AF0 HW4L-AF0 1NC HW-F01 HW-F01R (late break) Spring-Up Terminal HW-G10 HW-G10R (early make) HW-G01 HW-G01R (late break) Exposed Screw Terminal HW-C10 HW-C10R (early make) HW-C01 HW-C01R (late break) Contact Block Mounting Adaptor Style Part Number Anti-Rotation Ring Part Number Appearance HW-CBL 1. Used to mount contact blocks to operator (first pair only). 2. IDEC strongly recommends using the safety lever lock to prevent heavy vibration or maintenance personnel from inadvertently unlocking contacts. Safety Lever Lock Style HW9Z-RL Use with notched panel cutout to prevent unit rotation. Lamps Style Part Number HW9Z-LS LED Lenses Style Round Flush Part Number HW1A-L1-k Round Extended HW1A-L2-k In place of k, specify the Lens Color Code from previous page. 800-262-IDEC (4332) * USA & Canada Incandescent Voltage Part Number 6V AC/DC LSTD-6k 12V AC/DC LSTD-1k 24V AC/DC LSTD-2k 120V AC LSTD-H2k 240V AC LSTD-M4k 6V AC/DC IS-6 12V AC/DC IS-12 24V AC/DC IS-24 1. In place of k, specify the LED Color Code. 2. The LED contains a current-limiting resistor and reverse polarity protection diodes. 3. Yellow LED not available, use white LED when using yellow lens. 567 Circuit Breakers Plastic Bezel Style 1NO HW-F10 HW-F10R (early make) 1. All assembled part numbers in catalog include standard fingersafe (HW-F...) contacts. 2. Assembled units with spring-up terminals (HW-G...) can be ordered by removing an "F" from the part number (Ex. HW1B-M1F11-R becomes HW1B-M111-R). 3. Units with exposed screw terminals (HW-C...) must be ordered as sub-components. HW-L16D HW-GA1 "Dummy Block with full voltage adaptor" does not require the use of HW-LH3. Contacts Standard Fingersafe (IP20) Terminal Blocks HW-DA1FB 120V 240V 480V DC-DC Converter HW-LH3 Fingersafe For use with odd number of contacts. Style Contactors Transformer Unit (6V secondary voltage) Part Number Timers Dummy Block with Full Voltage Adaptor Terminals Switches & Pilot Devices Switches & Pilot Devices o22mm - HW Series Relays & Sockets Signaling Lights Illuminated Mushroom & Square Pushbuttons (Assembled) Full Voltage Timers Momentary Transformer Contactors Momentary Maintained 1. Plastic Bezel Metal Bezel Plastic Bezel Operator Only HW1L-M4-k HW4L-M4-k HW2L-M1-k 1NO HW1L-M4F10Qm-k-l HW4L-M4F10Qm-k-l HW2L-M1F10Qm-k-l 1NC HW1L-M4F01Qm-k-l HW4L-M4F01Qm-k-l HW2L-M1F01Qm-k-l 1NO-1NC HW1L-M4F11Qm-k-l HW4L-M4F11Qm-k-l HW2L-M1F11Qm-k-l 2NO HW1L-M4F20Qm-k-l HW4L-M4F20Qm-k-l HW2L-M1F20Qm-k-l Operator Only HW1L-A4-k HW4L-A4-k HW2L-A1-k 1NO HW1L-A4F10Qm-k-l HW4L-A4F10Qm-k-l HW2L-A1F10Qm-k-l 1NC HW1L-A4F01Qm-k-l HW4L-A4F01Qm-k-l HW2L-A1F01Qm-k-l 1NO-1NC HW1L-A4F11Qm-k-l HW4L-A4F11Qm-k-l HW2L-A1F11Qm-k-l 2NO HW1L-A4F20Qm-k-l HW4L-A4F20Qm-k-l HW2L-A1F20Qm-k-l 1NO-1NC HW1L-M4F11lm-k HW4L-M4F11lm-k HW2L-M1F11lm-k 2NO HW1L-M4F20lm-k HW4L-M4F20lm-k HW2L-M1F20lm-k 1NO-1NC HW1L-A4F11lm-k HW4L-A4F11lm-k HW2L-A1F11lm-k 2NO HW1L-A4F20lm-k HW4L-A4F20lm-k HW2L-A1F20lm-k Full voltage and transformer units use the same operator. Terminal Blocks 2. In place of k, specify the Lens/LED Color Code from table. 3. In place of lspecify the Voltage Code from table. Circuit Breakers 4. In place of m specify Lamp Type Code from table. 5. Light independent of switch position 6. For nameplates and accessories, see page 596. and 599. 7. For dimensions, see page 601. 8. For contact assembly part numbers, see page 600. 9. Additional contact configurations available (up to 6 total contacts). 10. Yellow pushbutton comes with white LED. 568 Square Flush Contacts Maintained 40mm Mushroom Head k Lens/LED Color Code Color Code Amber A Green G Red R Blue S White W Yellow Y* l Voltage Code m Lamp Code Full Voltage Models 1. *40mm mushroom lenses not available in yellow. 2. Yellow LED not available. Use white LED for yellow lens. Transformer Models Voltage Code Voltage Code 6V AC/DC 6V 120V AC H2 12V AC/DC 12V 240V AC M4 24V AC/DC 24V 480V AC T8 120V AC (LED only) 120V 240V AC (LED only) 240V www.IDEC.com Lamp Code Incandescent Blank LED D Switches & Pilot Devices W 1 Switches & Pilot Devices H o22mm - HW Series Part Number Structure - M 1 F 10 Q D - G - 12V L Lamp Voltage Bezel 1: Round Plastic 2: Square Plastic 4: Round Metal Function M: Momentary A: Maintained Lens Color Operator 1: Square Flush 4: Mushroom A: Amber S: Blue G: Green W: White R: Red Y: Yellow Contact Arrangement Illumination Circuit Q: Full Voltage H2: Transformer 120V AC M4: Transformer 240V AC T8: Transformer 480V AC Lamp Code *LED only D: LED Blank: Incandescent Signaling Lights 10: 1NO 01: 1NC 11: 1NO-1NC 20: 2NO (full voltage units only) 6V: 6V AC/DC 12V: 12V AC/DC 24V: 24V AC/DC 120V: 120VC AC* 240V: 240V AC* Illuminated Mushroom & Square Pushbuttons (Replacement Parts) Transformer* + Contact Blocks + Lead Holder + Adaptor + Safety Lever Lock + Lamp Anti-Rotation Ring + + Operator + Lens Completed Unit = Relays & Sockets *Transformer not needed with full voltage models. Lamp Circuit Components Contact Blocks Style Description Lead Holder For use with HW-CBL on all illuminated pushbutton units. One required for each deck (pair) of contacts. Full Voltage Adaptor For use with even number of contacts. 120VAC 240VAC 480VAC 120V 240V 480V DC-DC Converter HW-LH3 Fingersafe HW-DA1FB Exposed HW-DA1B Spring Up HW-GA1 Fingersafe TW-DA1FB Exposed TW-DA1B Fingersafe TW-F126B TW-F246B TW-F486B Spring Up HW-T126 HW-T246 HW-L486 Exposed TW-T126B TW-T246B TW-T486B Standard Fingersafe (IP20) HW-F10 HW-F10R (early make) HW-F01 HW-F01R (late break) Spring-Up Terminal HW-G10 HW-G10R (early make) HW-G01 HW-G01R (late break) Exposed Screw Terminal HW-C10 HW-C10R (early make) HW-C01 HW-C01R (late break) Contact Block Mounting Adaptor Part Number Appearance 1. Used to mount contact blocks to operator (first pair only). 2. IDEC strongly recommends using the safety lever lock to prevent heavy vibration or maintenance personnel from inadvertently unlocking contacts. Safety Lever Lock Style Part Number HW9Z-RL Use with notched panel cutout to prevent unit rotation. Lamps Style LED Momentary HW1L-M0L HW4L-M0L Maintained HW1L-A0L HW4L-A0L Momentary HW2L-M0 Maintained HW2L-A0 - Style Part Number Incandescent o40mm Mushroom Lens ALW4BLU-k* Square Flush HW2A-L1-k 1. In place of k, specify the Lens Color Code. 2. *Mushroom lens not available in yellow. 800-262-IDEC (4332) * USA & Canada Voltage Part Number 6V AC/DC LSTD-6k 12V AC/DC LSTD-1k 24V AC/DC LSTD-2k 120V AC LSTD-H2k 240V AC LSTD-M4k 6V AC/DC IS-6 12V AC/DC IS-12 24V AC/DC IS-24 Circuit Breakers Metal Bezel Part Number HW-CBL Lenses Plastic Bezel Style Anti-Rotation Ring HW9Z-LS Operators Square 1NC HW-L16D HW-GA1 "Dummy Block with full voltage adaptor" does not require the use of HW-LH3. o40mm Mushroom 1NO 1. All assembled part numbers in catalog include standard fingersafe (HW-F...) contacts. 2. Assembled units with spring-up terminals (HW-G...) can be ordered by removing an "F" from the part number (Ex. HW1B-M1F11-R becomes HW1B-M111-R). 3. Units with exposed screw terminals (HW-C...) must be ordered as sub-components. Style 110VDC Contacts Terminal Blocks 120V 240V 480V Style Contactors Transformer Unit (6V secondary voltage) For use with odd number of contacts. Part Number Timers Dummy Block with Full Voltage Adaptor Terminals 1. In place of k, specify the LED Color Code. 2. The LED contains a current-limiting resistor and reverse polarity protection diodes. 3. Yellow LED not available, use white LED when using yellow lens. 569 Switches & Pilot Devices Switches & Pilot Devices o22mm - HW Series Signaling Lights Selector Switches 2-Position (Assembled) Mounting Relays & Sockets Contact 2-Position Selector Switches Operator Position L R Operator Only Timers Handle Maintained L Spring Return from Right L R Knob Lever HWnS-2T HWnS-2L HWnS-21T HWnS-21L 1NO 1 O X Knob Lever HWnS-2TF10 HWnS-2LF10 HWnS-21TF10 HWnS-21LF10 1NO1NC 1 2 O X X O Knob Lever HWnS-2TF11 HWnS-2LF11 HWnS-21TF11 HWnS-21LF11 2NO 1 2 O O X X Knob Lever HWnS-2TF20 HWnS-2LF20 HWnS-21TF20 HWnS-21LF20 2NO2NC 1 2 3 4 X O X O O X O X Knob Lever HWnS-2TF22 HWnS-2LF22 HWnS-21TF22 HWnS-21LF22 Contactors 1. In place of n enter 1 for plastic bezel or 4 for metal bezel. 2. For nameplates, see page 596. 3. All assembled part numbers in catalog include standard fingersafe (HW-F...) contacts. 4. Assembled units with spring-up terminals (HW-G...) can be ordered by removing an "F" from the part number (Ex. HW1BM1F11-R becomes HW1B-M111-R). 5. Units with exposed screw terminals (HW-C...) must be ordered as sub-components. 6. Standard color for knob and lever is black. 7. Optional colors available for lever type. Must order in components. See next page for part numbers. 8. Additional contact configurations available (up to 6 total contacts). 9. For Truth Tables see page 608. n Bezel Type Type Code Plastic 1 Metal 4 Circuit Breakers Terminal Blocks R 570 www.IDEC.com Switches & Pilot Devices o22mm - HW Series Switches & Pilot Devices Part Number Structure H W 1 S - 2 1 T F 10 Contact Arrangement 10: 1NO 11: 1NO-1NC 20: 2NO Bezel 1: Plastic 4: Metal # of Positions 2: 2-Position Handle Operator T: Knob L: Lever Signaling Lights blank: Maintained 1: Spring Return from Right Selector Switches 2-Position (Replacement Parts) Contact Blocks + Mounting Adaptor + Safety Lever Lock Style 1NC Standard Fingersafe (IP20) HW-F10 HW-F01 HW-F10R (early make) HW-F01R (late break) HW-G10 HW-G01 HW-G10R (early make) HW-G01R (late break) HW-C10 HW-C01 Exposed Screw Terminal = Completed Unit Style Part Number HW9Z-RL Use with notched panel cutout to prevent unit rotation. Operators Style Description HW-C01R (late break) TW-DB Part Number Metal Bezel Knob HW1S-2T HW4S-2T Lever HW1S-2 HW4S-2 Spring Return from Right Knob HW1S-21T HW4S-21T Lever HW1S-21 HW4S-21 1. Knob operator comes with black handle. 2. To order lever type, lever and inserts must be ordered separately, along with lever operator. See part numbers below. Levers & Inserts Style 1. Used to mount contact blocks to operator (first pair only). 2. IDEC strongly recommends using the safety lever lock to prevent heavy vibration or maintenance personnel from inadvertently unlocking contacts. Part Number Lever TW-HC1-j Standard lever color is black. Standard insert color is white. 800-262-IDEC (4332) * USA & Canada j Handle/Insert Color Code Color Code Black* B Blue S Green G Red R Yellow Y White W Circuit Breakers Lever Color Insert ASWHHL-j Terminal Blocks HW-CB2C Part Number Plastic Bezel Contactors HW-C10R (early make) Contact Block Mounting Adaptor Safety Lever Lock Handle Maintained Dummy Block HW9Z-LS Operator Timers 1NO Spring-Up Terminal Style + Anti-Rotation Ring Contacts Style Anti-Rotation Ring Relays & Sockets Contact Blocks + 1. * Lever color inserts not available in black. 2. Lever not available in white. 571 Switches & Pilot Devices Selector Switches 3-Position (Assembled) Relays & Sockets Mounting 3-Position Selector Switches Contact Signaling Lights Switches & Pilot Devices o22mm - HW Series Operator Position L C R Contactors Timers Operator Only Terminal Blocks Handle Spring Return from Right Maintained L C L R Circuit Breakers L R C Spring Return Two-Way L R C Knob Lever HWnS-3T* HWnS-3L HWnS-31T HWnS-31L HWnS-32T HWnS-32L HWnS-33T HWnS-33L R 1NO1NC 1 2 0 0 X 0 X X Knob Lever HWnS-3TF11 HWnS-3LF11 HWnS-31TF11 HWnS-31LF11 HWnS-32TF11 HWnS-32LF11 HWnS-33TF11 HWnS-33LF11 2NO 1 2 X 0 0 0 0 X Knob Lever HWnS-3TF20 HWnS-3LF20 HWnS-31TF20 HWnS-31LF20 HWnS-32TF20 HWnS-32LF20 HWnS-33TF20 HWnS-33LF20 2NC 1 2 0 X X X X 0 Knob Lever HWnS-3TF02 HWnS-3LF02 HWnS-31TF02 HWnS-31LF02 HWnS-32TF02 HWnS-32LF02 HWnS-33TF02 HWnS-33LF02 2NO1NC 1 2 3 X 0 0 0 0 X 0 X 0 Knob HWnS-3JTF21N1 - - - 2NO2NC 1 2 3 4 X 0 0 X 0 0 X X 0 X X 0 Knob HWnS-3TF22 HWnS-31TF22 HWnS-32TF22 HWnS-33TF22 2NO2NC 1 2 3 4 0 X X 0 0 0 X 0 X 0 0 X Knob HWnS-3STF22N9 - - - 4NO 1 2 3 4 X 0 X 0 0 0 0 0 0 X 0 X Knob 4NO 1 2 3 4 X 0 X 0 0 X 0 0 0 X 0 X Knob HWnS-3STF40N2 - - - 4NC 1 2 3 4 0 X 0 X X X X X X 0 X 0 Knob HWnS-3TF04 HWnS-31TF04 HWnS-32TF04 HWnS-33TF04 n Bezel Type HWnS-3TF40 HWnS-31TF40 1. In place of n enter 1 for plastic bezel or 4 for metal bezel. 2. Knob operator includes black knob/lever operator includes black lever. 3. * Three position operator is available with three different cams. HWnS-3T: Maintained (standard cam) HWnS-3ST: Maintained (S cam) HWnS-3JT: Maintained (J cam) 4. Operator cams are color coded (white=standard cam, red=S cam, black =J cam). 5. For nameplates, see page 596. 6. For contact assembly part numbers, see page 600 572 C Spring Return from Left HWnS-32TF40 HWnS-33TF40 Type Code Plastic 1 Metal 4 7. All assembled part numbers in catalog include standard fingersafe (HW-F...) contacts. 8. Assembled units with spring-up terminals (HW-G...) can be ordered by removing an "F" from the part number (Ex. HW1B-M1F11-R becomes HW1B-M111-R). 9 . Units with exposed screw terminals (HW-C...) must be ordered as sub-components. 10. Standard color for knob and lever is black. 11. Optional colors available for lever type. Must order in components. See next page for part numbers. 12. Additional contact configurations available (up to 6 total contacts). 13. For Truth Tables see page 608. www.IDEC.com Switches & Pilot Devices o22mm - HW Series Switches & Pilot Devices Part Number Structure H W 1 S - 3 1 T F 20 Contact Arrangement 11: 1NO-1NC 20: 2NO 21: 2NO-1NC 22: 2NO-2NC 40: 4NO 04: 4NC Bezel 1: Plastic 4: Metal # of Positions 3: 3-Position Handle Operator T: Knob L: Lever Signaling Lights blank: Maintained 1: Spring Return from Right 2: Spring Return from Left 3: Spring Return Two Way Selector Switches 3-Position (Replacement Parts) Contact Blocks + Mounting Adaptor + Safety Lever Lock Style Anti-Rotation Ring 1NC Standard Fingersafe (IP20) HW-F10 HW-F01 HW-F10R (early make) HW-F01R (late break) HW-G10 HW-G01 HW-G10R (early make) HW-G01R (late break) HW-C10 HW-C01 HW-C10R (early make) HW-C01R (late break) Exposed Screw Terminal Dummy Block Style Completed Unit Part Number Operators Style TW-DB Handle Plastic Bezel Metal Bezel Maintained (standard cam) Knob HW1S-3T HW4S-3T Lever HW1S-3 HW4S-3 Maintained (S cam) Knob HW1S-3ST HW4S-3ST Maintained (J cam) Knob HW1S-3JT HW4S-3JT Spring Return from Right (standard cam) Knob HW1S-31T HW4S-31T Lever HW1S-31 HW4S-31 Knob HW1S-32T HW4S-32T Lever HW1S-32 HW4S-32 Knob HW1S-33T HW4S-33T Lever HW1S-33 HW4S-33 2-Way Spring Return (standard cam) HW-CB2C Safety Lever Lock Part Number Knob operator comes with black handle. Three position knob operator is available with three different cams. Operator cams are color coded (white=standard cam, red=S cam, black =J cam). To order lever type, lever and inserts must be ordered separately, along with lever operator. See part numbers below. Levers & Inserts Style j Handle/Insert Color Code Part Number Lever ASWHHL-j TW-HC1-j Color Code Color Code Black* B Red R Blue S Yellow Y Green G White W Circuit Breakers Lever Color Insert Terminal Blocks 1. 2. 3. 4. Contactors Description Spring Return from Left (standard cam) Part Number 1. Used to mount contact blocks to operator (first pair only). 2. IDEC strongly recommends using the safety lever lock to prevent heavy vibration or maintenance personnel from inadvertently unlocking contacts. Use with notched panel cutout to prevent unit rotation. HW9Z-RL Contact Block Mounting Adaptor HW9Z-LS = Timers 1NO Spring-Up Terminal Style Operator Anti-Rotation Ring Contacts Style + Relays & Sockets Contact Blocks + 1. * Lever color inserts not available in black. 2. Lever not available in white. Standard lever color is black. Standard insert color is white. 800-262-IDEC (4332) * USA & Canada 573 Switches & Pilot Devices Switches & Pilot Devices o22mm - HW Series Signaling Lights Selector Switches 4- & 5-Position (Assembled) 1 2 3 Handle 4 1 2 3 4 Operator Only Timers Maintained Knob Lever HWnS-4T HWnS-4L Operator Only 2NO2NC 1NO2NC 1 2 3 4 X 0 0 0 0 X 0 0 O 0 X 0 O 0 0 0 Knob Lever HWnS-4TF12 HWnS-4LF12 1NO3NC 1 2 3 4 O O O O X X O O X O X O X O O X Knob Lever HWnS-4TF13N6 HWnS-4LF13N6 2NO2NC 1 2 3 4 X O O O O X O O O O X O O O O X Knob Lever HWnS-4TF22N3 HWnS-4LF22N3 Contactors 1. In place of n enter 1 for plastic bezel or 4 for metal bezel. 2. Knob operator includes black knob/lever operator includes black lever. 3. For nameplates, see page 596. 4. For contact assembly part numbers, see page 600. 5. Five position circuit cannot be made to make five independent contact closures. 6. All assembled part numbers in catalog include standard fingersafe (HW-F...) contacts. 7. Assembled units with spring-up terminals (HW-G...) can be ordered by removing an "F" from the part number (Ex. HW1B-M1F11-R becomes HW1B-M111-R). 8. Units with exposed screw terminals (HW-C...) must be ordered as sub-components. 9. Standard color for knob and lever is black. 10. Optional colors available for lever type. Must order in components. See next page for part numbers. 11. Additional contact configurations available (up to 6 total contacts). 12. For Truth Tables see page 608. 1 2 3 4 n Bezel Type Type Code Plastic 1 Metal 4 Circuit Breakers Terminal Blocks Mounting 5-Position Selector Switch Operator Position Contact Mounting Relays & Sockets Contact 4-Position Selector Switches 574 www.IDEC.com Operator Position 1 X O O O 2 O X O O 3 O O O O 4 O O X O Handle 5 O O O X Maintained 2 3 1 4 5 Knob Lever HWnS-5T HWnS-5L Knob Lever HWnS-5TF22N3 HWnS-5LF22N3 Switches & Pilot Devices o22mm - HW Series Switches & Pilot Devices Part Number Structure H W 1 S - 4 T F 13N6 Contact Arrangement Bezel 1: Plastic 4: Metal (based on desired truth table) 12: 1NO-2NC 13N6: 1NO-3NC 22N3: 2NO-2NC # of Positions 4: 4-Position 5: 5-Position Handle T: Knob L: Lever Signaling Lights Selector Switches 4- & 5-Position (Replacement Parts) Contact Blocks + Mounting Adaptor + Safety Lever Lock Style Anti-Rotation Ring + 1NC Standard Fingersafe (IP20) HW-F10 HW-F01 HW-F10R (early make) HW-F01R (late break) HW-G10 HW-G01 HW-G10R (early make) HW-G01R (late break) HW-C10 HW-C01 HW-C10R (early make) HW-C01R (late break) Exposed Screw Terminal Style Part Number HW9Z-RL Use with notched panel cutout to prevent unit rotation. Operators Style Position 4 TW-DB 5 Description Metal Bezel Knob HW1S-4T HW4S-4T Lever HW1S-4 HW4S-4 Knob HW1S-5T HW4S-5T Lever HW1S-5 HW4S-5 Maintained 1. Knob operator comes with black handle. 2. To order lever type, lever and inserts must be ordered separately, along with lever operator. See part numbers below. Part Number Levers & Inserts HW-CB2C Part Number Lever Lever Color Insert ASWHHL-j TW-HC1-j 800-262-IDEC (4332) * USA & Canada Color Code Black* B Blue S Green G Red R Yellow Y White W Circuit Breakers Standard lever color is black. Standard insert color is white. j Handle/Insert Color Code Terminal Blocks Style 1. Used to mount contact blocks to operator (first pair only). 2. IDEC strongly recommends using the safety lever lock to prevent heavy vibration or maintenance personnel from inadvertently unlocking contacts. Part Number Plastic Bezel Maintained Contact Block Mounting Adaptor Safety Lever Lock Handle Contactors Dummy Block HW9Z-LS Completed Unit Timers 1NO Spring-Up Terminal Style = Anti-Rotation Ring Contacts Style Operator Relays & Sockets Contact Blocks + 1. * Lever color inserts not available in black. 2. Lever not available in white. 575 Switches & Pilot Devices Key Switches 2-Position (Assembled) Mounting Contact 2-Position Key Switches Operator Position L R Operator Only Maintained L R Spring Return from Right L R HWnK-2A HWnK-21B 1NO 1 O X HWnK-2AF10 HWnK-21BF10 1NO1NC 1 2 0 X X 0 HWnK-2AF11 HWnK-21BF11 2NO 1 2 O O X X HWnK-2AF20 HWnK-21BF20 2NO2NC 1 2 3 4 0 X 0 X X 0 X 0 HWnK-2AF22 HWnK-21BF22 Timers Relays & Sockets Signaling Lights Switches & Pilot Devices o22mm - HW Series Contactors 1. In place of n enter 1 for plastic bezel or 4 for metal bezel. 2. Key is removable in all maintained positions. Other key removable options available. 3. Two keys are supplied with all switches. 4. All standard operators are keyed alike. 5. Other key removable options available. See table below 6. For nameplates, see page 596. 7. For contact assembly part numbers, see page 600. 8. Key is retained in "Spring Return" position. 9. All assembled part numbers in catalog include standard fingersafe (HW-F...) contacts. 10. Assembled units with spring-up terminals (HW-G...) can be ordered by removing an "F" from the part number (Ex. HW1B-M1F11-R becomes HW1B-M111-R). 11. Units with exposed screw terminals (HW-C...) must be ordered as sub-components. 12. Additional contact configurations available (up to 6 total contacts). 13. For Truth Tables see page 600. Code Description A Key not retained in any position (removable in all positions) B Key retained in right position only C Key retained in left position only Circuit Breakers Terminal Blocks Key Removable Option Codes 576 www.IDEC.com n Bezel Type Type Code Plastic 1 Metal 4 Switches & Pilot Devices o22mm - HW Series Switches & Pilot Devices Part Number Structure H W 1 K - 2 1 B F 10 Contact Arrangement 10: 1NO 20: 2NO 11: 1NO-1NC 22: 2NO-2NC Bezel 1: Plastic 4: Metal # of Positions 2: 2-Position Operator Key Retained Position blank: Maintained 1: Spring Return from Right Signaling Lights A: Key not retained in any position (removable in all positions) B: Key retained in right position only C: Key retained in left position only Key Switches 2-Position (Replacement Parts) Contact Assembly + Mounting Adaptor + Safety Lever Lock Style + Operator = Completed Unit Safety Lever Lock 1NC Standard Fingersafe (IP20) HW-F10 HW-F01 HW-F10R (early make) HW-F01R (late break) HW-G10 HW-G01 HW-G10R (early make) HW-G01R (late break) HW-C10 HW-C01 HW-C10R (early make) HW-C01R (late break) Exposed Screw Terminal Dummy Block Style HW9Z-LS Anti-Rotation Ring Style Use with notched panel cutout to prevent unit rotation. Operators Part Number HW-CB2C Description Plastic Bezel Metal Bezel Maintained HW1K-2A HW4K-2A Maintained, key removed left only HW1K-2B HW4K-2B Spring Return from Right HW1K-21B HW4K-21B Maintained, key removed right only HW1K-2C HW4K-2C Terminal Blocks Contact Block Mounting Adaptor Part Number HW9Z-RL Style TW-DB Part Number Contactors 1NO Timers Contacts Spring-Up Terminal Style Anti-Rotation Ring Relays & Sockets Contact Blocks + 1. Operator includes two keys. 2. All standard operators are keyed alike. Circuit Breakers 1. Used to mount contact blocks to operator (first pair only). 2. IDEC strongly recommends using the safety lever lock to prevent heavy vibration or maintenance personnel from inadvertently unlocking contacts. 800-262-IDEC (4332) * USA & Canada 577 Switches & Pilot Devices Key Switches 3-Position (Assembled) Mounting 3-Position Key Switches Contact Signaling Lights Switches & Pilot Devices o22mm - HW Series Operator Position L C R Spring Return from Right Maintained L C L R C R Spring Return from Left L C Spring Return Two Way L R C R n Bezel Type HWnK-3A* HWnK-31B HWnK-32C HWnK-33D Type Code HWnK-31BF11 HWnK-32CF11 HWnK-33DF11 Plastic 1 Metal 4 1NO1NC 1 2 0 0 X 0 X X HWnK-3AF11 2NO 1 2 X 0 0 0 0 X HWnK-3AF20 HWnK-31BF20 HWnK-32CF20 HWnK-33DF20 2NC 1 2 0 X X X X 0 HWnK-3AF02 HWnK-31BF02 HWnK-32CF02 HWnK-33DF02 2NO1NC 1 2 3 X 0 0 0 0 X 0 X 0 HWnK-3JAF21N1 2NO2NC 1 2 3 4 X 0 0 X 0 0 X X 0 X X 0 HWnK-3AF22 2NO2NC 1 2 3 4 0 X X 0 0 0 X 0 X 0 0 X HWnK-3SAF22N9 4NO 1 2 3 4 X 0 X 0 0 0 0 0 0 X 0 X HWnK-3AF40 4NO 1 2 3 4 X 0 X 0 0 X 0 0 0 X 0 X HWnK-3SAF40N2 4NC 1 2 3 4 0 X 0 X X X X X X 0 X 0 HWnK-3AF04 Terminal Blocks Contactors Timers Relays & Sockets Operator Only Circuit Breakers 1. In place of n enter 1 for plastic bezel or 4 for metal bezel. 2. Key is removable in all maintained positions. Other key removable options available. 3. Two keys are supplied with all switches. 4. All standard operators are keyed alike. 5. Other key removable options available. See table to the right. 6. * Operator is available with three different cams. HWnK-3A: Maintained (standard cam) HWnK-3SA: Maintained (Cam S) HWnK-3JA: Maintained (Cam J) 7. For nameplates, see page 596. 578 - HWnK-31BF22 - HWnK-31BF40 - HWnK-31BF04 - HWnK-32CF22 - HWnK-33DF22 - HWnK-32CF40 - HWnK-33DF40 - HWnK-32CF04 8. For contact assembly part numbers, see page 600. 9. All assembled part numbers in catalog include standard fingersafe (HW-F...) contacts. 10. Assembled units with spring-up terminals (HW-G...) can be ordered by removing an "F" from the part number (Ex. HW1B-M1F11-R becomes HW1B-M111R). 11. Units with exposed screw terminals (HW-C...) must be ordered as sub-components. 12. Additional contact configurations available (up to 6 total contacts). 13. For Truth Tables see page 608. www.IDEC.com - HWnK-33DF04 Key Removable Option Codes Code Description A Key not retained in any position (removable in all positions) B Key retained in right position only C Key retained in left position only D Key retained in left and right (3 position only) E Key retained in center only (3 position only) G Key retained right and center (3 position only) H Key retained left and center (3 position only) Switches & Pilot Devices o22mm - HW Series Switches & Pilot Devices Part Number Structure H W 1 K - 3 1 B F 11 Contact Arrangement 11: 1NO-1NC 40: 4NO 20: 2NO 04: 4NC 22: 2NO-2NC Bezel 1: Plastic 4: Metal # of Positions 3: 3-Position Operator blank: Maintained 1: Spring Return from Right 2: Spring Return from Left 3: Spring Return Two Way Key Removable Option Code (see chart on previous page) Signaling Lights Key Switches 3-Position (Replacement Parts) Contact Assembly + Mounting Adaptor + Safety Lever Lock Style = Completed Unit Standard Fingersafe (IP20) HW-F10 HW-F01 HW-F10R (early make) HW-F01R (late break) HW-G10 HW-G01 HW-G10R (early make) HW-G01R (late break) HW-C10 HW-C01 HW-C10R (early make) HW-C01R (late break) Style Part Number HW9Z-LS Anti-Rotation Ring Style Part Number HW9Z-RL Use with notched panel cutout to prevent unit rotation. Operators Style TW-DB Part Number 1. 2. 3. 4. Description Plastic Bezel Metal Bezel Maintained (standard cam) HW1K-3A HW4K-3A Maintained (S cam) HW1K-3SA HW4K-3SA Maintained (J cam) HW1K-3JA HW4K-3JA Spring Return from Right (standard cam) HW1K-31B HW4K-31B Spring Return from Left (standard cam) HW1K-32C HW4K-32C 2-Way Spring Return (standard cam) HW1K-33D HW4K-33D Terminal Blocks Contact Block Mounting Adaptor HW-CB2C Contactors 1NC Dummy Block Style Operator Timers 1NO Exposed Screw Terminal + Safety Lever Lock Contacts Spring-Up Terminal Anti-Rotation Ring Relays & Sockets Contact Blocks + Operator includes two keys. All standard operators are keyed alike. Other key removable options available. See table on previous page. Key not removable from spring-returned position Circuit Breakers 1. Used to mount contact blocks to operator (first pair only). 2. IDEC strongly recommends using the safety lever lock to prevent heavy vibration or maintenance personnel from inadvertently unlocking contacts. 800-262-IDEC (4332) * USA & Canada 579 Switches & Pilot Devices Switches & Pilot Devices o22mm - HW Series Signaling Lights Illuminated Selector Switches 2-Position (Assembled) 2-Position Illuminated Selector Switches Relays & Sockets Contact Mounting Style Operator Position L Part Number Type R L Operator Only L R HWnF-2k Full Voltage 1NO1NC 1 2 O X X O 2NO 1 2 O O X X 2NO2NC 1 2 3 4 O X O X X O X O Transformer Transformer HWnF-21k HWnF-2F11Qm-k-l HWnF-21F11Qm-k-l HWnF-2F11H2m-k HWnF-2F11M4m-k HWnF-2F11T8m-k HWnF-21F11H2m-k HWnF-21F11M4m-k HWnF-21F11T8m-k HWnF-2F20Qm-k-l HWnF-21F20Qm-k-l 120V 240V 480V HWnF-2F20H2m-k HWnF-2F20M4m-k HWnF-2F20T8m-k HWnF-21F20H2m-k HWnF-21F20M4m-k HWnF-21F20T8m-k HWnF-2F22Qm-k-l HWnF-21F22Qm-k-l 120V 240V 480V HWnF-2F22H2m-k HWnF-2F22M4m-k HWnF-2F22T8m-k HWnF-21F22H2m-k HWnF-21F22M4m-k HWnF-21F22T8m-k Full Voltage Transformer R 120V 240V 480V Full Voltage Timers Spring Return from Right Maintained Terminal Blocks Contactors 1. In place of k specify Lens/LED color code. 2. In place of l specify Full Voltage code. 3. In place of m specify Lamp code. 4. In place of n enter 1 for plastic bezel or 4 for metal bezel. 5. For nameplates, see page 596. 6. For contact assembly part numbers, see page 600. 7. Light is independent of switch position. 8. All assembled part numbers in catalog include standard fingersafe (HW-F...) contacts. 9. Assembled units with spring-up terminals (HW-G...) can be ordered by removing an "F" from the part number (Ex. HW1B-M1F11-R becomes HW1B-M111-R). 10. Units with exposed screw terminals (HW-C...) must be ordered as sub-components. 11. Yellow selector switch comes with white LED. 12. Additional contact configurations available (up to 6 total contacts). 13. For Truth Tables see page 608. Circuit Breakers k Lens/LED Color Code 580 l Full Voltage Code Full Voltage Models m Lamp Code n Bezel Code Color Code Lamp Code Type Code Amber A Voltage Code Incandescent Blank Plastic 1 Green G 6VAC/DC 6V LED D Metal 4 Red R 12VAC/DC 12V Blue S 24VAC/DC 24V White W 120V AC (LED only) 120V Yellow Y 240V AC (LED only) 240V www.IDEC.com Switches & Pilot Devices W 1 F Part Number Structure - 21 F 20 Q D - G - 24V Bezel 1: Plastic 4: Metal Lamp Voltage Contact Arrangement 2: Maintained 21: Spring Return from Right 11: 1NO-1NC 20: 2NO 22: 2NO-2NC Illumination Circuit Q: Full Voltage H2: Transformer 120V AC M4: Transformer 240V AC T8: Tranformer 480V AC Illuminated Selector Switches 2-Position (Replacement Parts) Transformer* + Contact Blocks + Lead Holder + Mounting Adaptor + Safety Lever Lock + Lamp + Anti-Rotation Ring + Operator + Lens = Completed Unit Contact Blocks Lamp Circuit Components Style Description Lead Holder For use with HW-CBL on all illuminated pushbutton units. One required for each deck (pair) of contacts. Dummy Block with Full Voltage Adaptor For use with odd number of contacts. For use with even number of contacts. 120VAC 240VAC 480VAC 120V 240V 480V DC-DC Converter HW-LH3 Fingersafe HW-DA1FB Exposed HW-DA1B Spring Up HW-GA1 Fingersafe TW-DA1B Fingersafe TW-F126B TW-F246B TW-F486B Spring Up HW-T126 HW-T246 HW-L486 Exposed TW-T126B TW-T246B TW-T486B 110VDC Operators Style Style Metal Bezel Maintained HW1F-2 HW4F-2 Spring return from right HW1F-21 HW4F-21 Standard Fingersafe (IP20) HW-F10 HW-F10R (early make) HW-F01 HW-F01R (late break) Spring-Up Terminal HW-G10 HW-G10R (early make) HW-G01 HW-G01R (late break) Exposed Screw Terminal HW-C10 HW-C10R (early make) HW-C01 HW-C01R (late break) HW-CBL 1. Used to mount contact blocks to operator (first pair only). 2. IDEC strongly recommends using the safety lever lock to prevent heavy vibration or maintenance personnel from inadvertently unlocking contacts. Safety Lever Lock Style Part Number Color Code Color Code Amber A Blue S Green G White W Red R Yellow Y Anti-Rotation Ring Style Part Number HW9Z-RL Use with notched panel cutout to prevent unit rotation. Lamps Style HW9Z-LS LED Illuminated Knob Appearance Part Number HW9Z-FDY-k In place of k, specify the Color Code. Illuminated knobs must be ordered separately. 800-262-IDEC (4332) * USA & Canada Incandescent Voltage Part Number 6V AC/DC LSTD-6k 12V AC/DC LSTD-1k 24V AC/DC LSTD-2k 120V AC LSTD-H2k 240V AC LSTD-M4k 6V AC/DC IS-6 12V AC/DC IS-12 24V AC/DC IS-24 Circuit Breakers Description Plastic Bezel 1NC Part Number HW-L16D 1. HW-GA1 "Dummy Block with full voltage adaptor" does not require the use of HW-LH3. 2. DC-DC convertor features spring-up terminals. 3. DC-DC convertor applicable voltage range 90-140V DC. 1NO Contact Block Mounting Adaptor k Lens/LED Color Code TW-DA1FB Exposed Contacts Terminal Blocks 120V 240V 480V Style Contactors Transformer Unit (6V secondary voltage) Terminals Part Number Timers Full Voltage Adaptor Relays & Sockets *Transformer not needed with full voltage models. Signaling Lights (Full voltage units only) 6V: 6V AC/DC A: Amber S: Blue G: Green W: White 12V: 12V AC/DC R: Red Y: Yellow 24V: 24V AC/DC 120V: 120V AC* Lamp Code 240V: 240V AC* D: LED *LED only Blank: Incandescent Lens Color Position Switches & Pilot Devices H o22mm - HW Series 1. In place of k, specify the LED Color Code. 2. The LED contains a current-limiting resistor and reverse polarity protection diodes. 3. Use white LED for yellow lens. Yellow LED not available. 581 Switches & Pilot Devices Signaling Lights Switches & Pilot Devices o22mm - HW Series Illuminated Selector Switches 3-Position (Assembled) 3-Position Illuminated Selector Switches Mounting Relays & Sockets Contact Style Part Number Operator Position L C Type R L Operator Only Full Voltage 1NO1NC 1 2 O O X O X X 2NO 1 2 O 0 X 0 O X 2NC 1 2 O X X X X O 2NO2NC 1 2 3 4 X O O X O O X X O X X O X O X O O O O O O X O X Full Voltage 4NO 1 2 3 4 O X O X X X X X X O X O Full Voltage 4NC 1 2 3 4 Transformer 120V 240V 480V Timers Full Voltage Transformer 120V 240V 480V Terminal Blocks Contactors Full Voltage Transformer Transformer Transformer Circuit Breakers 1. In place of k specify Lens/LED color code. 2. In place of l specify Full Voltage code. 3. In place of m specify Lamp code. 4. In place of n enter 1 for plastic bezel or 4 for metal bezel. 5. For nameplates, see page 596. 6. For contact assembly part numbers, see page 600. 7. Light is independent of switch position. 8. All assembled part numbers in catalog include standard fingersafe (HW-F...) contacts. 582 120V 240V 480V Full Voltage Transformer Spring Return from Right Maintained 120V 240V 480V 120V 240V 480V 120V 240V 480V C L R C R Spring Return from Left L C Spring Return TwoWay L R C R HWnF-3k HWnF-31k HWnF-32k HWnF-33k HWnF-3F11Qm-k-l HWnF-31F11Qm-k-l HWnF-32F11Qm-k-l HWnF-33F11Qm-k-l HWnF-3F11H2m-k HWnF-3F11M4m-k HWnF-3F11T8m-k HWnF-31F11H2m-k HWnF-31F11M4m-k HWnF-31F11T8m-k HWnF-32F11H2m-k HWnF-32F11M4m-k HWnF-32F11T8m-k HWnF-33F11H2m-k HWnF-33F11M4m-k HWnF-33F11T8m-k HWnF-3F20Qm-k-l HWnF-31F20Qm-k-l HWnF-32F20Qm-k-l HWnF-33F20Qm-k-l HWnF-3F20H2m-k HWnF-3F20M4m-k HWnF-3F20T8m-k HWnF-31F20H2m-k HWnF-31F20M4m-k HWnF-31F20T8m-k HWnF-32F20H2m-k HWnF-32F20M4m-k HWnF-32F20T8m-k HWnF-33F20H2m-k HWnF-33F20M4m-k HWnF-33F20T8m-k HWnF-3F02Qm-k-l HWnF-31F02Qm-k-l HWnF-32F02Qm-k-l HWnF-33F02Qm-k-l HWnF-3F02H2m-k HWnF-3F02M4m-k HWnF-3F02T8m-k HWnF-31F02H2m-k HWnF-31F02M4m-k HWnF-31F02T8m-k HWnF-32F02H2m-k HWnF-32F02M4m-k HWnF-32F02T8m-k HWnF-33F02H2m-k HWnF-33F02M4m-k HWnF-33F02T8m-k HWnF-3F22Qm-k-l HWnF-31F22Qm-k-l HWnF-32F22Qm-k-l HWnF-33F22Qm-k-l HWnF-3F22H2m-k HWnF-3F22M4m-k HWnF-3F22T8m-k HWnF-31F22H2m-k HWnF-31F22M4m-k HWnF-31F22T8m-k HWnF-32F22H2m-k HWnF-32F22M4m-k HWnF-32F22T8m-k HWnF-33F22H2m-k HWnF-33F22M4m-k HWnF-33F22T8m-k HWnF-3F40Qm-k-l HWnF-31F40Qm-k-l HWnF-32F40Qm-k-l HWnF-33F40Qm-k-l HWnF-3F40H2m-k HWnF-3F40M4m-k HWnF-3F40T8m-k HWnF-31F40H2m-k HWnF-31F40M4m-k HWnF-31F40T8m-k HWnF-32F40H2m-k HWnF-32F40M4m-k HWnF-32F40T8m-k HWnF-33F40H2m-k HWnF-33F40M4m-k HWnF-33F40T8m-k HWnF-3F04Qm-k-l HWnF-31F04Qm-k-l HWnF-32F04Qm-k-l HWnF-33F04Qm-k-l HWnF-3F04H2m-k HWnF-3F04M4m-k HWnF-3F04T8m-k HWnF-31F04H2m-k HWnF-31F04M4m-k HWnF-31F04T8m-k HWnF-32F04H2m-k HWnF-32F04M4m-k HWnF-32F04T8m-k HWnF-33F04H2m-k HWnF-33F04M4m-k HWnF-33F04T8m-k 9. Assembled units with spring-up terminals (HW-G...) can be ordered by removing an "F" from the part number (Ex. HW1B-M1F11-R becomes HW1B-M111-R). 10. Units with exposed screw terminals (HW-C...) must be ordered as subcomponents. 11. Yellow selector switch comes with white LED. 12. Additional contact configurations available (up to 6 total contacts). 13. For Truth Tables see page 608. k Lens/LED Color l Full Voltage Code Color Code Lamp Code Amber A Voltage Code Incandescent Blank Green G 6VAC/DC 6V LED D Red R 12VAC/DC 12V Blue S 24VAC/DC 24V White W 120V AC (LED only) 120V Yellow Y 240V AC (LED only) 240V www.IDEC.com Full Voltage Models m Lamp Code n Bezel Code Type Code Plastic 1 Metal 4 Switches & Pilot Devices W 1 F Part Number Structure - 31 F 20 Q D - G - 24V Bezel Full Voltage Code 6V: 6V AC/DC 12V: 12V AC/DC A: Amber S: Blue G: Green W: White 24V: 24V AC/DC R: Red Y: Yellow 120V: 120V AC* 240V: 240V AC* Lens Color Contact Arrangement 11: 1NO-1NC 22: 2NO-2NC Illumination Circuit 20: 2NO 40: 4NO Q: Full Voltage 02: 2NC 04: 4NC H2: Transformer 120V AC M4: Transformer 240V AC T8: Tranformer 480V AC Lamp Code *LED only D: LED Blank: Incandescent Illuminated Selector Switches 3-Position (Replacement Parts) Transformer* Contact Blocks + + Lead Holder + Mounting Adaptor + Safety Lever Lock + Lamp + Anti-Rotation Ring + Operator + Lens = Completed Unit Lamp Circuit Components Style Description Dummy Block with Full Voltage Adaptor Contacts 1NO 1NC Standard Fingersafe (IP20) HW-F10 HW-F10R (early make) HW-F01 HW-F01R (late break) HW-LH3 Spring-Up Terminal HW-G10 HW-G10R (early make) HW-G01 HW-G01R (late break) Fingersafe HW-DA1FB Exposed HW-DA1B Exposed Screw Terminal HW-C10 HW-C10R (early make) HW-C01 HW-C01R (late break) Spring Up HW-GA1 Terminals Fingersafe TW-DA1FB Exposed TW-DA1B Fingersafe TW-F126B TW-F246B TW-F486B 120V 240V 480V Spring Up HW-T126 HW-T246 HW-L486 120V 240V 480V Exposed TW-T126B TW-T246B TW-T486B For use with even number of contacts. 120VAC 240VAC 480VAC Style Part Number HW-CBL 1. Used to mount contact blocks to operator (first pair only). 2. IDEC strongly recommends using the safety lever lock to prevent heavy vibration or maintenance personnel from inadvertently unlocking contacts. Style Part Number Description Plastic Bezel Metal Bezel Maintained HW1F-3 HW4F-3 HW1F-31 HW4F-31 HW1F-32 HW4F-32 2-Way spring return HW1F-33 HW4F-33 Color Code A Blue S Green G White W Red R Yellow Y Anti-Rotation Ring Style Part Number HW9Z-RL Use with notched panel cutout to prevent unit rotation. Lamps Style LED Illuminated Knob Part Number HW9Z-FDY-k In place of k, specify the Color Code. Illuminated knobs must be ordered separately. 800-262-IDEC (4332) * USA & Canada Incandescent Voltage Part Number 6V AC/DC LSTD-6k 12V AC/DC LSTD-1k 24V AC/DC LSTD-2k 120V AC LSTD-H2k 240V AC LSTD-M4k 6V AC/DC IS-6 12V AC/DC IS-12 24V AC/DC IS-24 1. In place of k, specify the LED Color Code. 2. The LED contains a current-limiting resistor and reverse polarity protection diodes. 3. Use white LED for yellow lens. Yellow LED not available. 583 Circuit Breakers Spring return from right Spring return from left Code Amber HW9Z-LS Appearance Operators Color Safety Lever Lock HW-L16D 1. HW-GA1 "Dummy Block with full voltage adaptor" does not require the use of HW-LH3. 2. DC-DC convertor features spring-up terminals. 3. DC-DC convertor applicable voltage range 90-140V DC. Style Contact Block Mounting Adaptor k Lens/LED Color Code Terminal Blocks 110VDC Style Contactors DC-DC Converter For use with odd number of contacts. Part Number Timers Full Voltage Adaptor Transformer Unit (6V secondary voltage) Contact Blocks For use with HW-CBL on all illuminated pushbutton units. One required for each deck (pair) of contacts. Lead Holder Relays & Sockets *Transformer not needed with full voltage models. Signaling Lights 1: Plastic Position 4: Metal 3: Maintained 31: Spring Return from Right 32: Spring Return from Left 33: Spring Return 2-Way Switches & Pilot Devices H o22mm - HW Series Switches & Pilot Devices Switches & Pilot Devices o22mm - HW Series Signaling Lights Mono Lever Switches 2-Position (Assembled) 2-Position Mono Lever Switches Relays & Sockets Style Timers HW1M Standard Lever Contactors HW1M-L Interlocking Lever Part Number Description HW1M-F1010-20 Maintained up and down HW1M-F2020-20 Spring return up and down HW1M-F1010-40 Maintained up and down HW1M-F2020-40 Spring return up and down HW1M-F0101-20 Maintained right and left HW1M-F0202-20 Spring return right and left HW1M-F0101-40 Maintained right and left HW1M-F0202-40 Spring return right and left HW1M-LF1010-20 Maintained up and down HW1M-LF2020-20 Spring return up and down HW1M-LF1010-40 Maintained up and down HW1M-LF2020-40 Spring return up and down HW1M-LF0101-20 Maintained right and left HW1M-LF0202-20 Spring return right and left HW1M-LF0101-40 Maintained right and left HW1M-LF0202-40 Spring return right and left Circuit Diagrams 2 Position Left/Right Circuit Number 20 40 No. Position Left Center Right X 0 0 HW-F10 0 0 X HW-F10 X 0 0 HW-F10 0 0 X HW-F10 X 0 0 HW-F10 0 0 X 1 HW-F10 2 1 2 3 4 2 Position Up/Down Circuit Number 20 40 Circuit Breakers Terminal Blocks 1. All assembled part numbers in catalog include standard (HW-F...) contacts. 2. Assembled units with spring-up terminals (HW-G...) can be ordered by removing an "F" from the part number (Ex. HW1B-M1F11-R becomes HW1B-M111-R). 3. Units with exposed screw terminals (HW-C...) must be ordered as sub-components. 4. Additional contact configurations available (up to 6 total contacts). 584 Contact Mounting www.IDEC.com Contact Mounting No. Position Down Center Up X 0 0 HW-F10 0 0 X HW-F10 X 0 0 HW-F10 0 0 X HW-F10 X 0 0 HW-F10 0 0 X 1 HW-F10 2 1 2 3 4 Switches & Pilot Devices o22mm - HW Series Switches & Pilot Devices Part Number Structure H W 1 M - L F 0 blank: Standard L: Interlocking 1 0 1 up right down left Type 20 Circuit Number 20 or 40 (see contact arrangement on previous page) Lever Action 1: Maintained 2: Spring 0: Blocked Signaling Lights Mono Lever Switches 2-Position (Sub-assembled) Part Numbers Contact Assembly + Mounting Adaptor + Style Anti-Rotation Ring + Operator = Completed Unit Anti-Rotation Ring 1NO 1NC Standard Fingersafe (IP20) HW-F10 HW-F01 HW-F10R (early make) HW-F01R (late break) HW-G10 HW-G01 HW-G10R (early make) HW-G01R (late break) Spring-Up Terminal Exposed Screw Terminal HW-C10 HW-C01 HW-C10R (early make) HW-C01R (late break) Part Number HW9Z-RL Use with notched panel cutout to prevent unit rotation. Operators Style Description Part Number Standard Maintained Up/Down HW1M-1010 Spring return Up/Down HW1M-2020 Maintained Left/Right HW1M-0101 Spring return Left/Right HW1M-0202 Maintained Up/Down HW1M-L1010 Spring return Up/Down HW1M-L2020 Maintained Left/Right HW1M-L0101 Spring return Left/Right HW1M-L0202 Interlocking TW-DB Contact Block Mounting Adaptor Part Number Contactors Dummy Block Style Timers Contacts Style + Relays & Sockets Contact Blocks Safety Lever Lock Replacement Parts HW-CB2C Part Number Terminal Blocks Item Black Cap HW9Z-CPM 1. Used to mount contact blocks to operator (first pair only). 2. IDEC strongly recommends using the safety lever lock (included) to prevent heavy vibration or maintenance personnel from inadvertently unlocking contacts. Style HW9Z-BLM (fits standard operator only) Circuit Breakers Safety Lever Lock Boot Part Number HW9Z-LS 800-262-IDEC (4332) * USA & Canada 585 Switches & Pilot Devices Switches & Pilot Devices o22mm - HW Series Signaling Lights Mono Lever Switches 3- & 4-Position (Assembled) 3-Position 4-Position Relays & Sockets Style Part Number Description HW1M Standard Lever HW1M-F0121-30 Maintained right and left, spring return down Style HW1M-F0222-30 Spring return right, down, left HW1M-L Interlocking Lever HW1M-LF0121-30 Maintained right and left, spring return down HW1M-LF0222-30 Spring return right, down, left HW1M Standard Lever Circuit Diagram Timers Circuit Number 30 Contact Mounting No. Position Down Left Center Up Right 1 HW-F01 0 0 0 O X 2 HW-F01 X 0 0 O 0 3 HW-F10 0 X 0 0 0 HW1M-L Interlocking Lever Contactors Maintained all positions HW1M-F1212-22N9 Maintained up and down, spring left and right HW1M-2121-22N9 Spring up and down, maintained left and right HW1M-2222-22N9 Spring return all positions HW1M-LF1111-22N9 Maintained all positions HW1M-LF1212-22N9 Maintained up and down, spring left and right HW1M-LF2121-22N9 Spring up and down, maintained left and right HW1M-LF2222-22N9 Spring return all positions Contact Mounting No. 1 22N9 Position Down Left Center Up Right HW-F01 0 O 0 0 X 2 HW-F01 X 0 0 0 0 3 HW-F10 0 X 0 0 0 4 HW-F10 0 0 0 X 0 Terminal Blocks All assembled part numbers in catalog include standard (HW-F...) contacts. Assembled units with spring-up terminals (HW-G...) can be ordered by removing an "F" from the part number (Ex. HW1B-M1F11-R becomes HW1B-M111-R). Units with exposed screw terminals (HW-C...) must be ordered as sub-components. Additional contact configurations available (up to 6 total contacts). Circuit Breakers 586 Description HW1M-F1111-22N9 Circuit Diagram Circuit Number 1. 2. 3. 4. Part Number www.IDEC.com Switches & Pilot Devices o22mm - HW Series Switches & Pilot Devices Part Number Structure H W 1 M - L F 0 blank: Standard L: Interlocking 1 2 1 up right down left Type 30 Circuit Number 3 Position: 30 4 Position: 22N9 Lever Action 1: Maintained 2: Spring 0: Blocked Signaling Lights Mono Lever Switches 3 & 4-Position (Sub-assembled) Part Numbers Contact Assembly + Mounting Adaptor + Style + Anti-Rotation Ring 1NO 1NC Standard Fingersafe (IP20) HW-F10 HW-F01 HW-F10R (early make) HW-F01R (late break) HW-G10 HW-G01 HW-G10R (early make) HW-G01R (late break) Style HW-C01 Standard = Completed Unit Exposed Screw Terminal HW-C10 HW-C10R (early make) Part Number HW9Z-RL Use with notched panel cutout to prevent unit rotation. Operators HW-C01R (late break) TW-DB Interlocking Contact Block Mounting Adaptor Part Number HW1M-0121 Spring return, 3 position HW1M-0222 Maintained, 4 position HW1M-1111 Combination, 4 position HW1M-1212 Combination, 4 position HW1M-2121 Spring return, 4 position HW1M-2222 Combination, 3 position HW1M-L0121 Spring return, 3 position HW1M-L0222 Maintained, 4 position HW1M-L1111 Combination, 4 position HW1M-L1212 Combination, 4 position HW1M-L2121 Spring return, 4 position HW1M-L2222 Replacement Parts Item 1. Used to mount contact blocks to operator (first pair only). 2. IDEC strongly recommends using the safety lever lock (included) to prevent heavy vibration or maintenance personnel from inadvertently unlocking contacts. Part Number Black Cap HW9Z-CPM Boot Part Number Circuit Breakers Safety Lever Lock Part Number Combination, 3 position Terminal Blocks HW-CB2C Description Contactors Dummy Block Style Timers Spring-Up Terminal Style Operator Anti-Rotation Ring Contacts Style + Relays & Sockets Contact Blocks Safety Lever Lock HW9Z-BLM (fits standard operator only) HW9Z-LS 800-262-IDEC (4332) * USA & Canada 587 Switches & Pilot Devices Signaling Lights Switches & Pilot Devices o22mm - HW Series Pushbutton Selectors (Assembled) 2-Position Pushbutton Selectors Operator Position Left Cam Contacts Mounting Normal j Button Color Code Right Push Normal Push Relays & Sockets Operator Only 1NO-1NC A HW1R-2A-j 1 2 HW-F10 HW-F01 0 X X 0 0 0 X 0 1 2 HW-F10 HW-F10 0 0 X X 0 X X X HW1R-2AF20-j 2NO-2NC 1 2 3 4 HW-F10 HW-F01 HW-F10 HW-F01 0 X 0 X X 0 X 0 0 0 0 0 X 0 X 0 HW1R-2AF22-j 2NO 1 2 HW-F10 HW-F10 0 0 X 0 0 0 0 X HW1R-2DF20-j 2NO-2NC 1 2 3 4 HW-F10 HW-F10 HW-F01 HW-F01 0 0 X X X 0 0 X 0 0 X X 0 X X 0 HW1R-2DF22N1-j 1 2 3 4 HW-F10 HW-F10 HW-F01 HW-F01 0 0 0 X X 0 0 X 0 0 X 0 0 X X 0 1 2 3 4 HW-F10 HW-F10 HW-F01 HW-F01 0 0 0 X 0 X 0 0 0 0 X 0 X 0 0 0 1 2 3 4 HW-F01 HW-F10 HW-F01 HW-F10 0 0 0 0 0 X 0 X X 0 X 0 0 X 0 X Timers D HW1R-2D-j Operator Only Contactors 2NO-2NC HW1R-2E-j Operator Only F 2NO-2NC Terminal Blocks 2NO-2NC Circuit Breakers 2NO-2NC HW1R-2NF22N2-j HW1R-2T-j 1 2 3 4 HW-F10 HW-F10 HW-F01 HW-F01 0 0 X X 1. All assembled part numbers in catalog include standard (HW-F...) contacts. 2. Assembled units with spring-up terminals (HW-G...) can be ordered by removing an "F" from the part number (Ex. HW1B-M1F11-R becomes HW1B-M111-R). 588 HW1R-2FF22N1-j HW1R-2N-j Operator Only T HW1R-2EF22N1-j HW1R-2F-j Operator Only N HW1R-2AF11-j 2NO Operator Only E Part Number X X 0 0 X X 0 0 Blocked HW1R-2TF22N1-j 3. Units with exposed screw terminals (HW-C...) must be ordered as sub-components. 4. Operator only models come with operator and button. 5. Additional contact configurations available (up to 6 total contacts). www.IDEC.com Color Code Color Code Black B White W Green G Yellow Y Red R Gray N Blue S Switches & Pilot Devices o22mm - HW Series Switches & Pilot Devices Part Number Structure H W 1 R - 2 D F 22N1 - R Button Colors Operator B: Black G: Green R: Red S: Blue W: White Y: Yellow N: Gray Contact Arrangement Code 11: 1NO-1NC 20: 2NO (For additional contact codes see previous page) Signaling Lights A: Cam A D: Cam D E: Cam E F: Cam F N: Cam N T: Cam T Pushbutton Selectors (Sub-assembled) Contact Blocks + Mounting Adaptor + Safety Lever Lock Style Anti-Rotation Ring + Operator Safety Lever Lock Contacts Standard Fingersafe (IP20) Exposed Screw Terminal 1NC HW-F01 HW-F10R (early make) HW-F01R (late break) HW-G10 HW-G01 HW-G10R (early make) HW-G01R (late break) HW-C10 HW-C01 HW-C10R (early make) HW-C01R (late break) TW-DB Contact Block Mounting Adaptor (safety lever lock included) Style Part Number Part Number Part Number Round Flush HW9Z-LS HW1A-B1-j Anti-Rotation Ring Style HW9Z-RL Use with notched panel cutout to prevent unit rotation. Style In place of j, specify the Button Color Code from table below. Part Number Description Part Number Cam A HW1R-2A Cam D HW1R-2D Cam E HW1R-2E Cam F HW1R-2F Cam N HW1R-2N Cam T HW1R-2T j Button Color Code Color Code Color Black B White Code W Green G Yellow Y Red R Gray N Blue S Terminal Blocks Style Completed Unit Buttons Operators Dummy Block = Contactors HW-F10 Style Button Timers Spring-Up Terminal 1NO + Relays & Sockets Contact Blocks + HW-CB2C 800-262-IDEC (4332) * USA & Canada Circuit Breakers 1. Used to mount contact blocks to operator (first pair only). 2. IDEC strongly recommends using the safety lever lock (included) to prevent heavy vibration or maintenance personnel from inadvertently unlocking contacts. 589 Switches & Pilot Devices Dual Pushbutton Switches Key features: * Two pushbuttons and a pilot light are integrated into one spacesaving o22 mm control unit. * Momentary and interlock types are available for pushbuttons. Interlock type prevents both buttons from being pressed at the same time. * Pilot lights are available in full voltage and transformer with LED or incandescent lamps. * IP40 protection, IP65 when using silicon cover. * UL Listed, CSA approved, and EN compliant Applications: * Ideal for use as power switches and start/stop switches (available with I/ON and O/OFF markings on the buttons and a pilot light in the center). * Interlock type prevents two pushbuttons from being pressed at the same time. Relays & Sockets Signaling Lights Switches & Pilot Devices o22mm - HW Series Dual Pushbutton Switches (Assembled) Part Numbers Without Center Pilot Light Timers Operation Type Button Style Flush (top) Flush (bottom) Momentary Contactors Flush (top) Extended (bottom) Interlock* Flush (top) Extended (bottom) Top Button Bottom Button 1NO 1NC Part Number 590 mButton Color Code nLegend Code HW7D-B11F1001-mn 1NO 1NO HW7D-B11F1010-mn 1NO-1NC 1NO-1NC HW7D-B11F1111-mn 2NO 2NC HW7D-B11F2002-mn 2NO 2NO HW7D-B11F2020-mn 1NO 1NC HW7D-B12F1001-mn 1NO 1NO HW7D-B12F1010-mn 1NO-1NC 1NO-1NC HW7D-B12F1111-mn 2NO 2NC HW7D-B12F2002-mn 2NO 2NO HW7D-B12F2020-mn 1NO 1NC HW7D-B21F1001-mn 1NO 1NO HW7D-B21F1010-mn 1NO-1NC 1NO-1NC HW7D-B21F1111-mn 2NO 2NC HW7D-B21F2002-mn 2NO 2NO HW7D-B21F2020-mn HW7D-B22F1001-mn 1NO 1NC 1NO 1NO HW7D-B22F1010-mn 1NO-1NC 1NO-1NC HW7D-B22F1111-mn 2NO 2NC HW7D-B22F2002-mn 2NO 2NO HW7D-B22F2020-mn 1. *Interlock type prevents both top and bottom buttons from being pressed simultaneously. 2. Clear silicon rubber cover part number HW9Z-D7D. 3. Additional contact configurations available (up to 6 total contacts). Circuit Breakers Terminal Blocks Flush (top) Flush (bottom) Contact Arrangement www.IDEC.com GR: Green (top) Red (bottom) WB: White (top) Black (bottom) Blank: Without legend 1: I/ON (top) O/OFF (bottom) Switches & Pilot Devices o22mm - HW Series Switches & Pilot Devices With Center Pilot Light Operation Type Button Style Flush (Top) Flush (Bottom) Flush (top) Flush (bottom) Momentary Flush (top) Extended (bottom) Interlock* Flush (Top) Extended (Bottom) Part Number 1NO 1NC HW7D-L11F1001kl-mn 1NO 1NO HW7D-L11F1010kl-mn 1NO-1NC 1NO-1NC HW7D-L11F1111kl-mn 2NO 2NC HW7D-L11F2002kl-mn 2NO 2NO HW7D-L11F2020kl-mn 1NO 1NC HW7D-L12F1001kl-mn 1NO 1NO HW7D-L12F1010kl-mn 1NO-1NC 1NO-1NC HW7D-L12F1111kl-mn 2NO 2NC HW7D-L12F2002kl-mn 2NO 2NO HW7D-L12F2020kl-mn 1NO 1NC HW7D-L21F1001kl-mn 1NO 1NO HW7D-L21F1010kl-mn 1NO-1NC 1NO-1NC HW7D-L21F1111kl-mn 2NO 2NC HW7D-L21F2002kl-mn 2NO 2NO HW7D-L21F2020kl-mn 1NO 1NC HW7D-L22F1001kl-mn 1NO 1NO HW7D-L22F1010kl-mn 1NO-1NC 1NO-1NC HW7D-L22F1111kl-mn 2NO 2NC HW7D-L22F2002kl-mn 2NO 2NO HW7D-L22F2020kl-mn Relays & Sockets Flush (Top) Flush (Bottom) Bottom Button Signaling Lights Flush (Top) Extended (Bottom) Top Button *Interlock type prevents both top and bottom buttons from being pressed simultaneously. Clear silicon rubber cover part number HW9Z-D7D. All assembled part numbers in catalog include standard (HW-F...) contacts. Assembled units with spring-up terminals (HW-G...) can be ordered by removing an "F" from the part number (Ex. HW1B-M1F11-R becomes HW1B-M111-R). 5. Units with exposed screw terminals (HW-C...) must be ordered as sub-components. kPilot Light Illumination & Voltage Code Full Voltage l Pilot Lamp Color Code Timers 1. 2. 3. 4. mPushbutton Color Code Color Code Color Amber A* Top Green Code Code Green G* Bottom Red 6V AC/DC, LED Q2 Red R* Top White 12V AC/DC, LED Q3 Blue S* Bottom Black 24V AC/DC, LED Q4 White 120V AC, LED Q8 6V AC/DC, Incandescent Q5* 12V AC/DC, Incandescent Q6* 24V AC/DC, Incandescent Q7* GR WB Engraving Code No Engraving Blank I/ON Top O/OFF Bottom Contactors Voltage nEngraving Codes 1 W *Only available in LED illumination. Terminal Blocks Step-Down Transformer (6V Secondary Lamp Voltage) Code 120V AC, LED H22 240V AC, LED M42 480V AC, LED T82 120V AC, Incandescent H25* 240V AC, Incandescent M45* 480V AC, Incandescent T85* Circuit Breakers Voltage *Only available for White Lens Pilot Lamp. 800-262-IDEC (4332) * USA & Canada 591 Switches & Pilot Devices H Pilot Light B: Without Center Pilot Light L: With Center Pilot Light D Part Number Structure - L 21 F 20 20 H22 R - GR 1 Engraving Code Voltage Code blank: without center pilot light A: Amber* G: Green* Full Voltage* Transformer* Q2: 6V LED H22: 120V AC LED R: Red* *For additional voltage codes, please see previous page S: Blue* W: White 02: 2NC 20: 2NO blank: No Engraving 1: Top: I/ON Bottom: O/OFF Pilot Lamp Color Y: Yellow* blank: without center pilot light Pushbutton Color GR: Top: Green Bottom: Red WB: Top: White Bottom: Black *Only available in LED illumination. Dual Pushbutton Switches (Sub-assembled) Part Numbers + Mounting Adaptor Lamp Circuit Components with Fingersafe Terminals Style Part Number Description Lead Holder Dummy Block with Full Voltage Adaptor For use with HW-CBL on all illuminated pushbutton units. One required for each deck (pair) of contacts. HW-LH3 For use with odd number of contacts. HW-DA1FB + Safety Lever Lock For use with even number of contacts. 120VAC 240VAC 480VAC Style Momentary 1NO 1NC = Completed Unit Style Contacts Flush (top) HW-G01 HW-G01R (late break) Dummy Block Exposed Screw Terminal HW-C01 HW-C01R (late break) TW-DB Part Number Non-illuminated Illuminated (with Pilot Light) Style HW-CB2C HW-CBL Extended (bottom) Flush (top) Flush (bottom) Flush (top) Extended (bottom) Code Top Green Bottom Red GR HW9Z-LS Anti-Rotation Ring Appearance Top White Bottom Black WB 12V AC/DC LSTD-1k 24V AC/DC LSTD-2k 120V AC LSTD-H2k 240V AC LSTD-M4k 6V AC/DC IS-6 12V AC/DC IS-12 24V AC/DC IS-24 Illuminated HW9Z-L7W 1. In place of k, specify the LED Color Code. 2. The LED contains a current-limiting resistor and reverse polarity protection diodes. kLED Color Code Use with notched panel cutout to prevent unit rotation. nEngraving Codes Code Part Number LSTD-6k HW9Z-B7B HW9Z-RL HW7D-*22m-n Color Voltage 6V AC/DC Nonilluminated Part Number HW7D-*21m-n mPushbutton Color Code Color Part Number HW-C10 HW-C10R (early make) Lamps/Lens 1. Used to mount contact blocks to operator (first pair only). 2. IDEC strongly recommends using the safety lever lock (included) to prevent heavy vibration or maintenance personnel from inadvertently unlocking contacts. Style Instead of * insert: B: Non-illuminated L: Illuminated 1NC HW-G10 Spring-Up HW-G10R Terminal (early make) HW7D-*11m-n HW7D-*12m-n 1NO Standard HW-F10 HW-F01 Fingersafe HW-F10R HW-F01R (IP20) (early make) (late break) Contact Block Mounting Adaptor TW-F126B TW-F246B TW-F486B Part Number Flush (bottom) Interlock Lens Safety Lever Lock Button Flush (top) Circuit Breakers Contacts TW-DA1FB Operators + Contact Blocks Exposed and spring up terminals also available. 592 Operator Style Full Voltage Adaptor Style + LED Contact Blocks Incandescent Contactors 7 11: Momentary (Flush/Flush) 12: Momentary (Flush/Extended) Bottom Button 01: 1NC 02: 2NC 21: Interlock (Flush/Flush) 10: 1NO 20: 2NO 22: Interlock (Flush/Extended) Timers Relays & Sockets 01: 1NC 10: 1NO Transformer Unit (6V secondary voltage) Terminal Blocks W Contact Arrangement Top Button Button Arrangement Signaling Lights Switches & Pilot Devices o22mm - HW Series Engraving Code No Engraving Blank I/ON Top O/OFF Bottom 1 www.IDEC.com Color Code Color Code Amber A* Blue S* Green G* White W Red R* Only for LED illumination. Switches & Pilot Devices o22mm - HW Series Contact Arrangement Top Button Bottom Button Contact Code 1NO 1NO 1010 1NO 1NC 1001 1NC 1NO 0110 1NC 1NO 2NO 1NO-1NC 1NO 2NC 1NC 2NO 1NO-1NC 2NC 2NO 1NO 1NC 1NO-1NC 1NC 0111 0102 2010 2001 1110 1101 2 NO 1 NO 2 NC 1 NC 2 NO 1 NC 2 NC 1 NO 2 NO 3 Dummy 4 NO 1 NO 2 NO 3 Dummy 4 NC 1 NO 2 NC 3 Dummy 4 NC 1 NC 2 NO 3 Dummy 4 NO 1 NC 2 NO 3 Dummy 4 NC 1 NC 2 NC 3 Dummy 4 NC 1 NO 2 NO 3 NO 4 Dummy 1 NO 2 NC 3 NO 4 Dummy 1 NO 2 NO 3 NC 4 Dummy 1 NO 2 NO 3 NC 4 Dummy Normal Mounting Position 4 Mounting Position 2 Push X X X Mounting Position 3 Mounting Position 1 X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X Circuit Breakers 1NO-1NC 1NO 0120 NO Push Terminal Blocks 2NO 1002 1 Normal Contactors 1NC 1011 Type Timers 1NC 1020 Mounting Position Bottom Button Relays & Sockets 1NO 0101 Top Button Signaling Lights 1NC Contact Block Mounting Position Example Contact Block Switches & Pilot Devices Contact Arrangement Chart X X 1. Transformers can have two or four contact blocks only. 2. Contact blocks 1 and 3 are actuated by the top button. Contact blocks 2 and 4 are actuated by the bottom button. 800-262-IDEC (4332) * USA & Canada 593 Switches & Pilot Devices Contact Block Mounting Position Example Contact Arrangement Chart (con't) Contact Arrangement Top Button 2NC Signaling Lights Switches & Pilot Devices o22mm - HW Series 2NC Relays & Sockets 2NO 2NO Timers 2NO 1NO-1NC Contactors 1NO-1NC 1NO-1NC Terminal Blocks 2NC 2NC Circuit Breakers 2NC 594 Bottom Button 1NO 1NC 2NO 1NO-1NC 2NC 2NO 1NO-1NC 2NC 2NO 1NO-1NC 2NC Contact Code 0210 0201 2020 2011 2002 1120 1111 1102 0220 0211 0202 Contact Block Mounting Position Top Button Type Normal 1 NC X 2 NO 3 NC 4 Dummy 1 NC 2 NC 3 NC 4 Dummy 1 NO 2 NO 3 NO 4 NO 1 NO 2 NO 3 NO 4 NC 1 NO 2 NC 3 NO 4 NC 1 NO 2 NO 3 NC 4 NO 1 NO 2 NO 3 NC 4 NC 1 NO 2 NC 3 NC 4 NC 1 NC 2 NO 3 NC 4 NO 1 NC 2 NO 3 NC 4 NC 1 NC 2 NC 3 NC 4 NC Bottom Button Push Normal X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X www.IDEC.com Mounting Position 4 Mounting Position 2 Push Mounting Position 3 Mounting Position 1 Switches & Pilot Devices o22mm - HW Series Switches & Pilot Devices Contactor Reset Button Signaling Lights Reset Buttons (Assembled) j Button Color Code Metal Bezel (Blank) HW1B-M1RS-jT HW4B-M1RS-jT Color Code Color Code Engraved "R" HW1B-M1RS-jT-ENG-R HW4B-M1RS-jT-ENG-R Black B White W Green G Yellow Y Red R Gray N Blue S 1. In place of j specify Button Color Code. 2. 130mm (5.1") overall length. 3. 16mm flat base for easy alignment Relays & Sockets Plastic Bezel Contactor Reset Button (Sub-assembled) Rod + Operator + Button = Completed Unit Timers Rod Button Style Part Number Style Part Number HW1A-B1-j Operator Style Plastic Contactors HW9Z-RS-TK2141 In place of j, specify the Button Color Code from table. Metal j Button Color Code HW4B-MO Code Color Code Black B White W Green G Yellow Y Red R Gray N Blue S Terminal Blocks HW1B-MO Color Circuit Breakers 800-262-IDEC (4332) * USA & Canada 595 Switches & Pilot Devices Switches & Pilot Devices o22mm - HW Series Nameplates - HW Series Engraving Plate R14.9 o22 1 45 1.6 0.9 2.7 12.1 30 27 HWAV-Yellow Plastic o22 1.9 1 Nameplate (blank engraving plate included) HWAM-OB HWAQ-OB HWAS-OB HWAV-O HWAV5-0 Nameplate (engraved) HWAM-j HWAQ-j HWAS-j HWAV-27* HWAV5-27 Additional Insert (blank) HWNP-O HWNP-O HWNP Dimensions Additional Insert (engraved) HWNP-j HWNP-j 12 Signaling Lights 1.5 HWAS-Black Plastic 14.5 14.9 2 29 2.7 14.5 14.9 R14.9 o2 Relays & Sockets Engraving Plate 12.1 30 29 27 HWAQ-Black Plastic o60mm HWAM-Black Plastic 1. 2. 3. 4. 27 In place of j, insert either the standard legend code from table below or custom engraving delimited by " ". Standard engravings are available at no charge. * HWAV-27 comes engraved "Emergency Stop" as shown in drawing. HWAV5-27 and HWAV5-0 for 60mm diameter E-Stops (80mm diameter nameplate). Standard Legend Codes Pushbuttons/Selector Switches Selector Switches Legend Code Legend Code Legend Code Legend Code Legend Code AUTO CLOSE DOWN EMERG.STOP FAST FORWARD HAND HIGH IN INCH JOG LOW LOWER OFF ON 101 102 103 104 105 106 107 108 109 110 111 112 113 114 115 OPEN OUT RAISE RESET REVERSE RUN SLOW START STOP TEST UP I (Int'l On) O (Int'l Off) EMO 116 117 118 119 120 121 122 123 125 126 127 150 151 152 AUTO-MAN CLOSE-OPEN DOWN-UP FAST-SLOW FOR-REV HAND-AUTO HIGH-LOW JOG-RUN LEFT-RIGHT LOWER-RAISE MAN-AUTO OFF-ON ON-OFF OPEN-CLOSE RAISE-LOWER 201 202 203 204 205 206 207 208 209 210 211 212 213 214 215 REV-FOR RUN-JOG RUN-SAFE SAFE-RUN SLOW-FAST START-STOP STOP-START UP-DOWN OI (Int'l OFF ON) 216 217 218 219 220 221 222 223 250 AUTO-MAN-OFF AUTO-OFF-MAN CLOSE-OFF-OPEN DOWN-OFF-SLOW FAST-OFF-SLOW FOR-OFF-REV LEFT-OFF-RIGHT LOWER-OFF-RAISE OFF-MAN-AUTO OFF-SLOW-FAST OFF-1-2 OPEN-OFF-CLOSE SLOW-OFF-FAST SUMMER-OFF-WINTER UP-OFF-DOWN 1-OFF-2 HAND-OFF-AUTO 301 302 303 304 305 306 307 308 309 310 311 312 313 314 315 316 317 1. 2. 3. 4. To order engraved nameplates, add legend code to nameplate part number. Character height based on the number of characters and size of nameplate. Standard character size is 3/16". Nameplates with standard legends are the same list price as blank nameplates. Nameplates have built-in anti-rotation feature for use with notched panel cut-outs. Additional anti-rotation ring (HW9Z-RL) is not necessary. Circuit Breakers Terminal Blocks Contactors Timers Pushbuttons 596 www.IDEC.com 22mm Switches & Pilot Devices o22mm - HW Series Switches & Pilot Devices Nameplates Order Form -- HW Series Copy this order form and use it to specify Letter Height, Custom Engravings, Location of Engraving on Nameplate, and Quantity Desired. To ensure engraving accuracy, fax it to your IDEC representative or Distributor. IDEC Rep/Distributor Contact: Name: PO number (if known): Telephone: IDEC Rep/Distributor Phone: Fax & Email: IDEC Rep/Distributor Fax & Email: Signaling Lights Your Company: HWAM Nameplate Engraving Location Step 2. Specify Quantity. Enter the number of nameplates desired in the box on the right. 7/64" Letter Size 11 characters maximum (for 7/64" size letters) 1/8" Letter Size 9 characters maximum (for 7/8" size letters) Relays & Sockets Step 1. Choose Letter Size - 7/64" or 1/8". Check the box for the letter size you want. Then write your lettering in box below the check boxes. Note: 1/8" size letters cannot exceed 9 characters. Sample Letter Sizes 7/64" Letters: A B C D Qty 1 2 3 4 5 6 7 8 9 10 11 1/8" Letters: A BCD Engraving Location Step 1. Choose Letter Size - 7/64" or 1/8". Check the box for the letter size you want. Then write your lettering in box below the check boxes. Note: 1/8" size letters cannot exceed 9 characters. 11 characters maximum (for 7/64" size letters) 1/8" Letter Size 9 characters maximum (for 7/8" size letters) Sample Letter Sizes Contactors Step 2. Specify Quantity. Enter the number of nameplates desired in the box on the right. 7/64" Letter Size Timers HWAQ Nameplate 7/64" Letters: A B C D Qty 1 2 3 4 5 6 7 8 9 10 11 1/8" Letters: A BCD HWAS Nameplate Step 3. Specify Location. Enter the location of engraving (A or B), in box on the right. Qty 20 characters maximum (for 3/32" size letters) 1/8" Letter Size 14 characters maximum (for 7/8" size letters) 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 Circuit Breakers Engraving Location B Step 2. Specify Quantity. Enter the number of nameplates desired in the box on the right. 3/32" Letter Size Terminal Blocks Engraving Location A Step 1. Choose Letter Size - 3/22" or 1/8". Check the box for the letter size you want. Then write your lettering in box below the check boxes. Note: 1/8" size letters cannot exceed 9 characters. Sample Letter Sizes 3/32" Letters: A B C D Location 800-262-IDEC (4332) * USA & Canada 1/8" Letters: A BCD 597 Switches & Pilot Devices Switch Engraving Order Form - HW Series Copy this order form and use it to specify Letter Height, Maximum Number of Lines and Text to be engraved. To ensure engraving accuracy, fax it to your IDEC representative or Distributor. Your Company: Telephone: Name: Fax: Address: Email: PO: Part Number to be Engraved: Signaling Lights Switches & Pilot Devices o22mm - HW Series Please check one of the boxes below to indicate your choice of engraving options: Relays & Sockets o29mm, o40mm Mushroom Head Engraving # of Lines Letter Height Max. Characters Per Line 5/32 # of Lines 5 1 Timers Engraving Area 1 Round Switch Square Switch Letter Height 5/32 Area 2 Max. Characters Per Line 5 1 1/8 6 5/32 5 2 1/8 5 5/32 5 2 6 3 1/8 6 4 3/32 5 Contactors 1/8 1. 2. 3. 4. 1/8 6 3 1/8 5 4 3/32 5 Engraving Area 2 1 Sample Letter Sizes 1/8 Letters: 5/32 Letters: Line 2: Terminal Blocks 1 Letter Height Max. Characters Per Line 5/32 5 1/8 5 5/32 7 1/8 7 Above mentioned specifications hold true for standard size pushbuttons (round and square). Engraving Area 2 can be engraved for 40mm mushroom Head non-Illuminated push button only. Engraving is done on the button itself for non-Illuminated push buttons and on marking plate for illuminated push buttons and pilot lights. Please enter text exactly how you want it engraved, take care to emphasize capital or small letters. Line 1: Circuit Breakers Engraving Area 1 Enter text to be engraved: Line 3: Line 4: For IDEC Internal Use Only: Work Order #: 598 # of Lines www.IDEC.com Switches & Pilot Devices o22mm - HW Series Switches & Pilot Devices Accessories Item Appearance Part Number Locking Ring Wrench Metallic tool used to tighten the plastic locking ring when installing the HW series in a panel MW9Z-T1 Lamp/LED Removal Tool Rubber tool makes lamp/LED removal easier. OR-55 Anti-Rotation Ring Prevents rotation of switches in panel. (included with all assembled switches except pilot lights) for notched panel cutout (standard) HW9Z-RL for round panel cutout LW9Z-L Black rubber plug fills unused 7/8" mounting holes in panel. OB-31 Metallic Mounting Hole Plug For plugging unused 7/8" mounting holes in the panel. Tighten the attached locking ring to a torque of 12 kfg-cm maximum Degree of protection: IP66 LW9Z-BM Barrier To prevent contact between adjacent lead wires when buttons or switches are tightly mounted close together. HW-VL1 Used to cover and protect pushbuttons Flush Pushbuttons OC-31 Operating temperature: -50 to +60C Extended Pushbuttons OC-32 Pushbutton Clear Boot Plastic hinged padlockable cover to protect pushbuttons or selector switches. (Not intended for E-Stops) HW9Z-KL1 Timers Padlock Cover Relays & Sockets Rubber Mounting Hole Plug Signaling Lights Description/Usage Degree of protection: IP65 Tab #250 (6.35 x 0.8mm): Single tab Mounting Adaptor Used to mount round HW series (except Jumbo Mushroom, unibody, and square units) into a larger panel cut-out. (includes both pieces) TW-FA1 22 to 30mm HW9Z-A30 22 to 25mm HW9Z-A25 Contactors Tab Terminal Adapter HW9Z-LS Reset Rod for Contactors Overload 5" rod used with HW1B-M0. HW9Z-RS-TK2141 Replacement Operator Washer Provided with operator. Insert between bezel and locking ring. HWM-WASHER Replacement Locking Ring Plastic locking nut comes with all HW operators & assemblies. Switch Cover (Square) Used only with round or square flush pushbuttons. HW9Z-K1 (spring return) HW9Z-K11 (maintained cover) Replacement Keys Pair of Keys (#231) HW9Z-SKP 800-262-IDEC (4332) * USA & Canada Standard (plastic) HW9Z-LN Optional (metal) HW9Z-LNM Circuit Breakers Used to prevent contact mounting lever from moving due to heavy vibration or panel maintenance. Terminal Blocks Replacement Safety Lever Lock 599 Switches & Pilot Devices Switches & Pilot Devices o22mm - HW Series Item Appearance Replacement Lens Description/Usage Part Number HW Illuminated Unibody Replacement Lens HWLV-LENSR Replacement Jumbo Dome Lens HW1A-P5j j = (A, G, R, S, W, Y)) Relays & Sockets Signaling Lights Polycarbonate Replacement Lens (If using yellow lens, use white LED.) Replacement Jumbo LED Diffusing Lens HW9Z-PP5C Replacement LED Lamps for HW Jumbo Dome Replacement LED Lamp - applicable for jumbo pilot lights only LSTDB-2j j = (A, G, R, S, W) Rubber Cover for Dual Pushbuttons Clear Silicon rubber cover HW9Z-D7D Barrier for Dual Pushbuttons Plastic barrier. Used when mounting the HW7 units on 30mm horizontal centers, to prevent possible interconnections between adjoining terminals. HW-VG1 Emergency stop nameplate sticker HW9Z-EMO-NP-TK2120 E MO EMO Sticker Style Contactors Timers E-Stop Shrouds E-Stop Types Applicable Standards HW9Z-KG1 40mm Mushroom Head SEMI S2-0703, 12.5.1 Compliant HW9Z-KG2 40mm, and 60mm Mushroom Head SEMI S2-0703, 12.5.1 & SEMATECH Compliant Part Numbers Style E-Stop Types Applicable Standards HW9Z-KG3 40mm Mushroom Head SEMI S2 Compliant (Approved by TUV) HW9Z-KG4 40mm Mushroom Head SEMI S2 Compliant (Approved by TUV) & SEMATECH Part Numbers Contact Assemblies Standard Contact Assemblies Circuit Breakers Terminal Blocks For use with Non-Illuminated Pushbuttons & E-Stops Style Contacts Part Number Standard Fingersafe Contacts 1NO 1NC 1NO/1NC 2NO 2NC 2NO/2NC HW-CBF10 HW-CBF01 HW-CBF11 HW-CBF20 HW-CBF02 HW-CBF22 Spring Up Terminal Contacts 1NO 1NC 1NO/1NC 2NO 2NC 2NO/2NC HW-CB10 HW-CB01 HW-CB11 HW-CB20 HW-CB02 HW-CB22 Full Voltage Contact Assemblies For use with Illuminated Pushbuttons. Style Order lamp separately. Gold contact option is available for spring-up terminals. Add suffix "MAU" to end of part number. For example, HW-CB20 becomes HW-CB20-MAU. 600 www.IDEC.com Contacts Part Number 1NO 2NO 1NO/1NC 1NC 2NC HW-FL10Q0 HW-FL20Q0 HW-FL11Q0 HW-FL01Q0 HW-FL02Q0 Switches & Pilot Devices o22mm - HW Series Switches & Pilot Devices Transfomer Contact Assemblies For use with Illuminated Pushbuttons. Style 120V AC with LED 1NO 2NO 1NC 1NO/1NC HW-FL10H2-k HW-FL20H2-k HW-FL01H2-k HW-FL11H2-k 240V AC with LED 1NO 2NO 1NC 1NO/1NC HW-FL10M4-k HW-FL20M4-k HW-FL01M4-k HW-FL11M4-k 480V AC with LED 1NO 2NO 1NC 1NO/1NC HW-FL10T8-k HW-FL20T8-k HW-FL01T8-k HW-FL11T8-k 120V AC with Incandescent 1NO 2NO 1NC 1NO/1NC HW-FL10H2 HW-FL20H2 HW-FL01H2 HW-FL11H2 240V AC with Incandescent 1NO 2NO 1NC 1NO/1NC HW-FL10M4 HW-FL20M4 HW-FL01M4 HW-FL11M4 Relays & Sockets Part Number Signaling Lights Contacts 1. In place of k, specify the LED Color Code. k = A, G, R, S, or W 2. 6V LED or incandescent lamp included. Dimensions (mm) Non-Illuminated Pushbuttons Extended (HW1B-M2, -A2) o29mm Mushroom (HW1B-M3 -A3) M3.5 Terminal Screw M3.5 Terminal Screw M3.5 Terminal Screw Locking Ring LO LO Locking Ring CK Panel Thickness 0.8 to 6 CK 41.4 o29 41.4 o29 o23.6 41.4 o29 LO 25 25 CK Panel Thickness 0.8 to 6 25 Locking Ring Panel Thickness 0.8 to 6 Timers Flush (HW1B-M1, -A1) 3.6 o2 13 13 29.4 50.2 (1 or 2 blocks) o40mm Mushroom (HW1B-M4, -A4) LO CK o60mm Mushroom (HW1B-M5) Square Flush (HW2B-M1, -A1) M3.5 Terminal Screw Locking Ring M3.5 Terminal Screw Panel Thickness 0.8 to 6 Locking Ring Panel Thickness 0.8 to 6 CK 29.6 o60 41.4 o40 50.2 (1 or 2 blocks) 29.4 23.2 LO 70.2 (4 blocks) 50.2 (1 or 2 blocks) 13 70.2 (4 blocks) 15 30 Terminal Blocks 13 50.2 (1 or 2 blocks) 29.4 23.2 25 Locking Ring Panel Thickness 0.8 to 6 70.2 (4 blocks) 25 M3.5 Terminal Screw 13 50.2 (1 or 2 blocks) Contactors 70.2 (4 blocks) 29.4 19 41.4 50.2 (1 or 2 blocks) 70.2 (4 blocks) 24.8 29.4 70.2 (4 blocks) Square Extended (HW2B-M2, -A2) M3.5 Terminal Screw Terminal Wiring Arrows indicate access directions for wiring Panel Thickness 0.8 to 6 LO CK Circuit Breakers 13 50.2 (1 or 2 blocks) 70.2 (4 blocks) 19 29.4 41.4 24.8 29.6 25 Locking Ring Contact Block (Bottom View) 1 contact block 2 contact blocks 4 contact blocks 800-262-IDEC (4332) * USA & Canada 601 Switches & Pilot Devices Operators Dimensions (mm) Flush (Round & Square) Extended Round Panel Thickness 0.8 to 6 CK LO CK .6 29.4 29.4 18.5 24.8 29.4 Extended with Full Shroud o40mm Mushroom LO LO CK 41.4 3.6 o40 41.4 25 25 CK o29.5 Extended 3 o2 13 o2 13 41.4 41.4 29.6 41.4 25 o23.5 25 CK 3.6 Signaling Lights LO Square LO 25 Switches & Pilot Devices o22mm - HW Series Relays & Sockets o2 29.4 18.5 13 29.4 23.2 Emergency Stop Pushbuttons Dimensions (mm) o29mm Head Pushlock Turn Reset (HW1B-V3) Panel Thickness 0.8 to 6 Gasket Terminal Screw M3.5 LOC Locking Ring o29 50.2 (1 or 2 blocks) 70.2 (4 blocks) 13 29.4 32 o40mm Head Pushlock Turn Reset (HW1B-V4) o40mm Head EMO Pushlock Turn Reset (HW1B-V4) LOC LOC K Locking Ring Lock Lever 0 o4 o40 41.4 20 25 26.5 K 13 29.4 13 32 32 o40mm Head Pushlock Key Reset (HW1B-X4) o60mm Head Pushlock Turn Reset (HW1B-V5) LOC K 41.4 o40 Circuit Breakers o60 25 Terminal Blocks 50.2 (1 or 2 blocks) 70.2 (4 blocks) 13 29.4 32 49.4 602 15 34.5 www.IDEC.com 29.4 41.4 2 contact blocks 4 contact blocks 25 1 contact block Contactors 41.4 25 Timers K Switches & Pilot Devices Switches & Pilot Devices o40mm Head Push-Pull (HW1B-Y2) o22mm - HW Series o40mm Head Unibody Pushlock Turn Reset (HW1B-BV4) LO Panel Thickness 0.8 to 6 CK Gasket M3.5 Terminal Screw o40 o40 41.4 25 Locking Ring 13 29.4 TOP Marking Terminal Cover 11.5 46 Signaling Lights 25.5 14 32 48 Illuminated E-Stop Pushbuttons (HW1E-LV4) Mounting Hole Panel Thickness 0.8 to 6 R0.8 max. Gasket .3 +0.4 0 o40 24.1 TOP Marking M3.5 Terminal Screw Lamp Terminal 11.5 14 32 61 Terminal Cover 63 The minimum mounting centers shown below are applicable to E-Stop switches with one layer of contact blocks (two contact blocks). When two layers of contact blocks are mounted, determine the minimum mounting centers for ease of wiring. Unit Vertical Spacing Horizontal Spacing HW1B-V3 HW1B-V4 HW1B-X4 HW1B-Y2 50 mm 50 mm HW1B-V5 60 mm 60 mm Relays & Sockets o22 Locking Ring +0.2 0 3.2 +0.4 0 M3.5 Terminal Screw HW1E-BV4 Side HW1E-LV4 Timers Terminal Arrangement (Bottom View) TOP X1 .2 (NC) .3 (NO) .1 (NC) .4 (NO) LAMP .2 (NC) .3 (NO) .1 (NC) .4 (NO) X2 (1NO-1NC) (1NO-1NC) Contactors Emergency Stop Stations 59.5 Operator Dimension A (mm) Pushlock Turn Reset 32 Pushlock Key Reset 32 (Key inserted: 49.4) Push Pull 25.5 Mounting Hole Layout 4-M4 Tapped Holes for Rear Mounting (Depth: 10 mm) 2-Front Mounting Holes o14 Knockout 21 76 A Terminal Blocks 76 Dimensions (mm) 21 41 HW1B-V4R Box Cover Mouting Screws Box Cover Box Base 2- o4 .6 Circuit Breakers 15.5 62 800-262-IDEC (4332) * USA & Canada 603 Switches & Pilot Devices Switches & Pilot Devices o22mm - HW Series Pilot Lights Dimensions (mm) Full Voltage Panel Thickness 0.8 to 6 Flush Gasket Locking Ring M3.5 Terminal Screw Dome Square Flush Round/Dome 9 o2 X2 X1 Transformer X1 X2 Round/Dome 9 Square Flush Close mounting on 30mm centers Degree of protection: IP65 30 min. Dome +0.4 0 o2 72.1 17.5 7 29.6 30 min. DC-DC Converter Flush M3.5 Terminal Screw Dome Round/Dome 9 Square Flush o2 When mounting transformer or DC-DC converter type units on 30mm centers vertically and horizontally, keep the ambient temperature below 40C. 24 X1 X2 76.2 29.6 29.6 17.5 7 Jumbo Dome Pilot Lights Base BA9S/13 Illumination Color Incandescent Lamp LSB Base BA9S/13 Mounting Hole Layout R0.8 max. o22.3 +0.4 0 3.2 +0.2 0 +0.4 0 Light blue: LSTDB o10.6 M3.5 Terminal Screw LED Lamp LSTDB 27 2 24.1 6 o6 1 Panel Thickness 1 to 5 o10 Relays & Sockets .3 o22 Mounting Hole Layout Flush M3.5 Terminal Screw 29.6 Timers 29.6 17.5 7 24 Signaling Lights 0.5 44.7 85 20.4 Locking Ring Rubber Gasket 50.5 Contactors 0.5 34.4 85 Illuminated Pushbuttons Full Voltage Models 1 Contact Block 2 Contact Blocks Terminal Blocks M3.5 Terminal Screw Contact Block Locking Ring 3 Contact Blocks Full Voltage Adapter Full Voltage Adapter Panel Thickness 0.8 to 6 M3.5 Terminal Screw Contact Block Locking Ring Full Voltage Adapter M3.5 Terminal Screw Contact Block Panel Thickness 0.8 to 6 Locking Ring X1 Circuit Breakers X2 1 contact block 604 50.2 (1 block) 2 contact blocks 65.8 (2 blocks) www.IDEC.com 3 contact blocks 70.2 (3 blocks) Panel Thickness 0.8 to 6 Switches & Pilot Devices o22mm - HW Series Dimensions (mm) 4 Contact Blocks Terminal Wiring Arrows indicate access directions for wiring. Full Voltage Adapter Contact Block Full Voltage Adaptor M3.5 Terminal Screw Contact Block Locking Ring Switches & Pilot Devices Illuminated Pushbuttons con't Transformer Panel Thickness 0.8 to 6 X1 X2 Signaling Lights 85.8 (4 contacts) 4 contact blocks Transformer Models DC-DC Converter Models Safety Lever Lock Locking Ring 3 X1 4 X2 Relays & Sockets X1 X2 M3.5 Terminal Screws 89.7 (2 blocks) 109.5 (4 blocks) M3.5 Terminal Screw 89.5 (2 blocks) 109.5 (4 blocks) Non-Illuminated Selector & Key Switches Dimensions (mm) Knob Operator Terminal Wiring M3.5 Terminal Screw Arrows indicate access directions for wiring. Panel Thickness 0.8 to 6 Gasket CK 9 Contact Block Full Voltage Adaptor 1 contact block 48.5 (1 or 2 blocks) 7 29.4 68.5 (3 or 4 blocks) 21 Key Operator Contactors 2 contact blocks 4 contact blocks 41.4 o28.8 25 o2 Timers LO Locking Ring Tranformer LOC K 9.4 25 o2 17 41.4 X1 X2 Terminal Blocks 13 29.4 30.5 Illuminated Selector Switches LO CK Transformer Model LOC K 9 41.4 25 X1 7 X2 M.3.5 Terminal Screw 79.5 (2 blocks) 99.5 (4 blocks) Circuit Breakers 69.4 (2 blocks) 41.4 o2 89.4 (4 blocks) 9 o2 25 4 M3.5 Terminal Screw 3 Full Voltage Model 7 21 29.4 29.4 21 800-262-IDEC (4332) * USA & Canada 605 Switches & Pilot Devices Dual Pushbutton Dimensions (mm) Without Pilot Light Mounting Hole Layout R0.8 max. o22 *3.2 +0. 4 0 +0.2 0 24.1 .3 +0.4 0 HW Switches & Pilot Devices o22mm - HW Series 49.4 (2 contacts) Without Button Markings Locking Ring With Button Markings (I/ON and O/OFF) 30 54.8 54.8 ON OFF Rubber Gasket Relays & Sockets 55 ** Panel Thickness 0.8 to 6 Safety Lever Lock 41.4 Signaling Lights 69.4 (3 or 4 contacts) 0.5 29.8 14.5 20 29.8 With Pilot Light Full Voltage The depth of a 3-contact model depends on the combination of contact blocks at top and bottom pushbuttons. Full Voltage Adapter HW (Bottom Button) Timers (Top Button) Top Button 1 contact block 2 contact blocks Bottom Button 2 contact blocks 1 contact block Depth 89.4 mm 69.4 mm -The 3.2 mm recess is for preventing rotation and is not necessary when a nameplate or anti-rotation ring is not used. -When using the safety lever lock, determine the vertical spacing in consideration of convenience for installing and removing the safety lever lock. -Recommended vertical spacing: 100 mm -The minimum mounting centers are applicable to switches with one layer of contact blocks (two contact blocks). When two layers of contact blocks are mounted, determine the minimum mounting centers for ease of wiring. 69.4 (2 contacts), 89.4 (4 contacts) (Note) Transfomer (240V minimum) Transformer (480V) Transformer, DC-DC Converter Transformer Contactors HW HW 89.5 (2 contacts), 109.5 (4 contacts) Locking Ring Panel Thickness 0.8 to 6 LO Monolever Dimensions (mm) o3 4 M3.5 Terminal Screw .2 79.5 (2 contacts), 99.5 (4 contacts) 8 Circuit Breakers 24 36 max. 45.5 606 29.4 72 24 49.4 (2 blocks) 69.4 (4 blocks) 36 max. Terminal Blocks 41.4 25 CK www.IDEC.com Switches & Pilot Devices o22mm - HW Series Switches & Pilot Devices Accessory Dimensions LW9Z-BM OB-31 Metallic Mounting Hole Plug OR-55 Anti-Rotation Ring Lamp/LED Removal Tool TOP o14 1.5 3.5 3.5 o25 HW-VG1 Dual Pushbutton Rubber Cover Dual Pushbutton Barrier MW9Z-T1 22.5 Barrier 28 o 110 58 45 45 33 HW-VL1 Locking Ring Wrench Signaling Lights HW9Z-D7D 59 o11.6 o29 o22 12 Gasket Locking Ring HW9Z-RL o29 3 o25.8 Rubber Mounting Hole Plug 1.5 20 1.5 HWLS-TK1971 Padlock Cover Relays & Sockets HW9Z-KL1 20 Safety Lever Lock Panel Thickness 0.8 to 3.2 Safety Lever Lock Screwdriver Remove Lock Lever Safety Lever Lock CK LO 26.5 70 30 93 6.5 R6 Operator Install 82.5 24 o2 2.2 0 o5 .4) 44 :o (ID Waterproof Rubber Gasket 0.5t Contact Block Mounting Adapter HW9Z-KG1 Timers 29.5 30 Key Hole o8 Panel HW9Z-KG2 38 22 36.5 80 32 o22 o90 Gasket TOP Marking TOP Marking Contactors o76.1 2.2 o2 64 48 Locking Ring TOP Marking TOP Marking Locking Ring Operator Panel Thickness: 1.2 to 4 Operator Terminal Blocks Panel Thickness: 1.2 to 4 HW9Z-KG3 HW9Z-KG4 LSTD 35 25 o2 35 25 2 o9.5 800-262-IDEC (4332) * USA & Canada 20.4 50 Circuit Breakers 42 o10.6 o90 67 o75 o74 52 o66 o22 607 Switches & Pilot Devices Switches & Pilot Devices o22mm - HW Series Specification Charts Signaling Lights Conforming to IED 947-5-1 Appendix C. Utilization categories AC-15 and DC-13. Operation rate: 1,800 op. hour Load factor: Inductive 0.4 0.05 Resistive 0.9 0.05 Operator Truth Tables 2 Position Selector Switches Timers Relays & Sockets Contact HW-F10 (NO) HW1S-2T HW1K-2* HW1F-2 HW-F01 (NC) HW-F10R (NO-EM) HW-F01R (NC-LB) Operator Position Left Right L O X R O X L X O R X O L O X R O X L X O R X O Contact HW1S-3JT HW1K-3J* HW-F10 (NO) HW1S-3T HW1K-3* HW1F-3 HW-F01 (NC) HW-F10R (NO-EM) HW-F01R (NC-LB) Mounting Position Operator Position Left Center Right HW-F10 (NO) L X O O R O O X HW-F01 (NC) L O X O R O X O HW-FC10R (NO-EM) L X O X R X O X HW-F01R (NC-LB) L O X X R X X O 4 Position Selector Switches 3 Position Selector Switches Contact Contactors Mounting Position 3 Position Selector Switches con't Contact Operator Position Mounting Position Left L X O O R O O X L O X X R X X O L X O O R O O X L O X X R X X O Center Right HW1S-4T Mounting Position Operator Position 1 2 3 4 HW-F10 (NO) L X O O O R O O O X HW-F01 (NC) L O O X O R O X O O HW-F10R (NO-EM) L X X O X R X O X X HW-F01R (NC-LB) L O X X X R X X X O 1 2 Terminal Blocks 5 Position Selector Switches Contact HW-F10 (NO) Circuit Breakers HW1S-3ST HW1K-3S* HW-F01 (NC) HW-F10R (NO-EM) HW-F01R (NC-LB) Operator Position Mounting Position Left Center Right L X O O R O O X L O O X R X O O L X X O R O X X L O X X R X X O Contact HW-F10 (NO) HW1S-5T HW-F10R (NO-EM) HW-F01R (NC-LB) 1. Mounting position indicates which side of operator each contact should be mounted (as viewed from the front of the panel). 2. *For key removable code see page 579. 608 HW-F01 (NC) Mounting Position Operator Position 4 5 O L X O O O R O O O O X L O O O X O R O X O O O L X X X O X R X O X X X L O X X X X R X X X X O 3. HW1S-3T is identified by white plungers on the operator. 4. HW1S-3ST is identified by red plungers on the operator. 5. HW1S-3JT is identified by black plungers on the operator. www.IDEC.com 3 Switches & Pilot Devices o22mm - HW Series Turn off power to HW series control units before starting installation, removal, wiring, maintenance, and inspection of the products. Failure to turn power off may cause electrical shocks or fire hazard. For wiring, use wires of a proper size to meet voltage and current requirements. Tighten the M3.5 terminal screws to a tightening torque of 1.0 to 1.3 N*m. Failure to tighten terminal screws may cause overheating and fire. To avoid the possibility of burning yourself, use the lamp holder tool when replacing lamps. Switches & Pilot Devices HW Safety Precautions HW General Instructions Remove the contact block assembly from the operator (for transformer type pilot lights, remove the transformer from the illumination unit). Remove the locking ring from the operator. Insert the operator into the panel cut-out from the front, tighten the locking ring from the back, then install the contact block assembly to the operator. Removing and Installing the Contact Block Assembly 2. To reinstall, place the TOP markings on the operator and the contact block mounting adapter in the same direction, and insert the operator into the contact block mounting adapter. Then turn the locking lever in the opposite direction. IDEC strongly recommends using the safety lever lock (HW9Z-LS, yellow) to prevent heavy vibration or maintenance personnel from unlocking the contact assembly. 1. HW series can be mounted vertically with a minimum spacing of 55 mm but spacing should be determined to ensure easy operation (recommended minimum spacing: 100 mm). 2. Mount the control unit onto the panel, lock the lever, and push in the safety lever lock to install. 3. When the spacing is narrower than the recommended value, with the lever unlocked, mount the safety lever lock and insert the contact unit to the operator. Then, lock the lever and strongly push in the safety lever lock to install. Relays & Sockets 1. To remove the operator from the contact block, turn the locking lever in the direction of the arrow shown below. The operator can now be removed. Safety Lever Lock Signaling Lights Panel Mounting 4. To remove the safety lever lock, insert a flat screwdriver into the safety lever and push upwards. Remove Safety Lever Lock CK LO 26.5 Lock Lever Timers Operator Install Safety Lever Lock Screwdriver Contact Block Mounting Adapter Notes for Panel Mounting Panel Contactors 1. When mounting the operator onto a panel, use the optional locking ring wrench (MW9Z-T1) to tighten the locking ring. Tightening torque must not exceed 2.0 N*m. Do not use pliers. Excessive tightening will damage the locking ring. 2. For the contact blocks and transformers housing LED and incandescent lamps, make sure not to press the lamps too hard, otherwise the lamp socket may be damaged. Terminal Blocks Dual Pushbutton Instructions Replacement of Lens Removing Remove the lens by inserting a screwdriver into the recess of the lens through the bezel. Circuit Breakers Installing Install the lens in the recess between the buttons by pressing against the bezel. 800-262-IDEC (4332) * USA & Canada 609 Switches & Pilot Devices Dual Pushbuttons Instructions con't Replacement of Lamps Tightening Torque for Terminal Screws Lamps can be replaced by using the lamp holder tool (OR-55) from the front of the panel, or by removing the contact block assembly from the operator unit. When using full voltage type LED illuminated units, provide protection against electrical noise, if necessary. Removal Applicable Wiring The applicable wire size is 2 mm2 maximum. (solid wire o1.6mm2 maximum) One or two wires can be connected. 1. To remove, slip the lamp holder tool onto the lamp head lightly. Then push slightly, and turn the lamp holder tool counterclockwise. Applicable Crimping Terminal 7.9 max. o3.6 min. Installation 1. To install, insert the lamp head into the lamp holder tool, and hold the lamp as shown in the figure below. 4 max. Lamp Solid Wire Timers Lamp Base 8 max. Note: When connecting wires to contact blocks or transformers in the direction shown below, keep the insulation stripping length 6.6 mm at the maximum. About Pushbutton Switches Do not attempt to remove using a flat screwdriver or pincers, otherwise the pushbuttons may be damaged. 5.5 min. Be sure to use an insulation tube or cover on the crimping part of the crimping terminal to prevent electrical shocks. Lamp Holder Tool Do not attempt to remove the pushbuttons! The pushbuttons cannot be removed or replaced! Contactors Installation of LED Illuminated Units Removing the Lamps from the Front of the Panel 2. Place the pins on the lamp base to the grooves in the lamp socket. Insert the lamp and turn it clockwise. X1 Pushbuttons X2 Inside X1 X2 Inside Installing the Rubber Cover Narrow Mounting When mounting the units closely in a horizontal row on 30mm centers, use optional barriers to prevent interconnection between adjoining terminals. The barriers can be attached simply by pressing them onto the sides of contact blocks. 30 When using the HW7D pushbuttons in places where the pushbuttons are subjected to water splash or an excessive amount of dust, make sure to use the HW9Z-D7D rubber boot (IP65) which is ordered separately. Notes for Installing the Rubber Cover 30 Remove the gasket from the operator, and install the rubber boot on the operator. Pull out the seals of the rubber boot and place them around the operator sleeve as shown. Make sure that the seals are not twisted or tucked inside and that the gasket does not remain, otherwise the normal waterproof and dustproof characteristics are not ensured. Terminal Blocks Circuit Breakers Tighten the M3.5 terminal screws to a torque of 1.0 to 1.3 N*m. o1.6 max. Relays & Sockets Signaling Lights Switches & Pilot Devices o22mm - HW Series 1. Remove the gasket. Barrier When mounting transformer type illuminated units closely in a horizontal row on 30-mm centers, insert solid wires or stranded wires into inside of the terminal screw on the transformer (see figure on the right) to prevent short circuit between adjoining terminals. Seals Install X1 X2 Inside X1 Remove X2 Inside Gasket 610 2. Install the rubber boot on the pushbuttons. www.IDEC.com Seals 3. Rubber boot is installed.