40621_Inhalt_124 14.10.2004 8:03 Uhr Seite 124 XP Special Switches Double break XP Characteristics Long overtravel plunger >3 mm contact gap Reset spring option for increased reset security Rating Up to 400 VAC, 16 A Dimensions (mm) 30 32 12 Actuator Plain or mushroom plungers Approvals UL, CSA, ENEC Preferred Range Ordering Reference Actuating Force (N) (ozf) Operating pos. (mm) (in) Terminal Circuit Actuator Contacts Electrical rating XP2Z11 3,0 10,0 14,9 0,587 Faston CO Straight plunger Silver nickel Up to 400 VAC, 16 A XP42Z11 1,8 6,2 14,9 0,587 Faston NC Straight plunger Silver nickel Up to 400 VAC, 16 A XP52Z11 3,0 10,0 13,0 0,511 Faston NO Straight plunger Silver nickel Up to 400 VAC, 16 A XP2E1Z11 6,5 23,3 14,9 0,587 Faston CO Mushroom plunger, reset Silver nickel Up to 400 VAC, 16 A XP42E1Z11 3,8 13,4 14,9 0,587 Faston NC Mushroom plunger, reset Silver nickel Up to 400 VAC, 16 A XP52E1Z11 6,5 23,3 13,0 0,511 Faston NO Mushroom plunger, reset Silver nickel Up to 400 VAC, 16 A XP2E2Z11 3,0 10,0 14,9 0,587 Faston CO Mushroom plunger, reset Silver nickel Up to 400 VAC, 16 A 124 | 125 www.saia-burgess.com saia-burgess Switches 40621_Inhalt_125 14.10.2004 8:03 Uhr Seite 125 XP Specifications Housing Plunger Mechanism Contacts Terminals Temperature range C Mechanical life Protection Mounting Actuators Special features Glass fibre reinforced nylon Glass fibre reinforced nylon Change-over, normally open, normally closed Silver 6.3 mm (0.25 in) faston (quick connect) - brass -20C to +140C 107 cycles minimum (impact free actuation) IP40 (enclosure) Screw mounting Straight or mushroom plunger Optional reset spring for increased reset security Circuit diagram 1 2 3 4 NORMALLY OPEN NORMALLY CLOSED .5 R2 .1] [0 13.00.2 [0.51] E"4.0 [0.16] 3 4 2 6.0 [0.24] 6.8 1 [0.27] 32.0 [1.26] 30.3 [1.19] 6.0 [0.24] 2 MOUNTING HOLES E"4.3A}0.05 [0.17] FREE POSITION 22.00.1 [0.87] OPERATING POSITION TOTAL TRAVEL POSITION Dimensions 6.3 X 0.8 [0.25 X 0.03] 10.0 [0.39] 12.0 [0.47] 30.0 [1.18] Recommended maximum electrical ratings Voltage (max) Resistive load (A) Inductive load Horsepower Approval 250 VAC 16 (0.75 pf) - - UL 1054/CSA 22.2 No. 55 - 6,000 operations 125 VAC 250 VAC - - 1 4 HP (0.45 pf) 4 HP (0.45 pf) UL 1054 - Horsepower- 6,000 operations UL 1054 - Horsepower- 6,000 operations 250 VAC 400 VAC 16 16 6 4 - EN.60158-1 T85 (C) 50,0000 operations EN.60158-1 T85 (C) 10,0000 operations 0-15 VDC 15-30 VDC 10 7 - - General rating - 50,000 operations General rating - 50,000 operations saia-burgess Switches 1 www.saia-burgess.com 124 | 125 40621_Inhalt_126 14.10.2004 8:03 Uhr Seite 126 XP Operating Characteristics Actuator Actuating Force Maximum (N) (ozf) Release Force Minimum (N) (ozf) Free Position Maximum (mm) (in) Operating Position (mm) 3,00 1,75 3,00 10,0 6,20 10,0 5,5 5,5 5,5 19,7 19,7 19,7 15,3 15,3 16,6 0,602 0,602 0,653 XP2E1Z11 6,5 XP42E1Z11 3,75 XP52E1Z11 6,5 23,3 13,4 23,3 9,0 9,0 9,0 32,3 32,3 32,3 15,3 15,3 16,6 XP2E2Z11 10,0 5,5 19,7 15,3 Reference Operating Position Full overtravel Position Mushroom plunger with reset spring Mushroom plunger (mm) (in) 14,9 0.4 14,9 0.4 13,0 0.4 0,587 0.016 0,587 0.016 0,511 0.016 8,0 8,0 8,0 0,315 0,315 0,315 4,5 6,5 4,5 0,177 0,256 0,177 0,602 0,602 0,653 14,9 0.4 14,9 0.4 13,0 0.4 0,587 0.016 0,587 0.016 0,511 0.016 10,5 10,5 10,5 0,413 0,413 0,413 2,1 4,0 2,1 0,082 0,157 0,082 0,602 14,9 0.4 0,587 0.016 8,6 0,339 4,0 0,157 Rest Position XP2Z11 XP42Z11 XP52Z11 Straight plunger Over travel (in) Total Travel Position Maximum (mm) (in) 3,0 Ordering Reference Type XP XPS Circuit 2 42 52 Actuators No digit E1 E2 Approvals Z11 126 | 127 Positive action Changeover Normally closed Normally open Straight plunger Mushroom plunger with reset spring Mushroom plunger UL, cUL, CSA and ENEC www.saia-burgess.com saia-burgess Switches