File Name:GSM60B-SPEC 2015-02-03





















v
Features
Description

















60W AC-DC Single Output Medical Adaptor GSM60B serie s
File Name:GSM60B-SPEC 2015-02-03
60W AC-DC Single Output Medical Adaptor GSM60B serie s
SPECIFICATION
ORDER NO.
SAFETY MODEL NO.
DC VOLTAGE Note.2
RATED CURRENT
CURRENT RANGE
RATED POWER (max.)
RIPPLE & NOISE (max.) Note.3
OUTPUT
SETUP, RISE TIME Note.6
HOLD UP TIME (Typ.)
VOLTAGE RANGE
FREQUENCY RANGE
EFFICIENCY (Typ.)
AC CURRENT (Typ.)
INPUT
ENVIRONMENT
INRUSH CURRENT (Typ.)
LEAKAGE CURRENT(max.)
SAFETY STANDARDS
SAFETY &
EMC
(Note. 7)
WORKING TEMP.
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
MTBF
DIMENSION
OTHERS
PACKING
PROTECTION
VOLTAGE TOLERANCE Note.4
LINE REGULATION Note.5
LOAD REGULATION
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
CONNECTOR
PLUG
CABLE
OVERLOAD
OVER VOLTAGE
OVER TEMPERATURE
EMC IMMUNITY
EMC EMISSION
5V 7.5V 9V 12V 15V 18V 24V 48V
100mVp-p 100mVp-p 100mVp-p 100mVp-p 100mVp-p 150mVp-p 180mVp-p 240mVp-p
6A 6A 6A 5A 4A 3.33A 2.5A 1.25A
0 ~ 6A 0 ~ 6A 0 ~ 6A 0 ~ 4A 0 ~ 3.33A 0 ~ 2.5A
0 ~ 1.25A
30W 45W 54W 60W
0 ~ 5A
60W 60W 60W 60W
GSM60B05
GSM60B05-P1J
GSM60B07-P1J
GSM60B09-P1J
GSM60B12-P1J
GSM60B15-P1J
GSM60B18-P1J
GSM60B24-P1J
GSM60B48-P1J
GSM60B07 GSM60B09 GSM60B12 GSM60B15 GSM60B18 GSM60B24 GSM60B48







For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.
(as available on http://www.meanwell.com)
80 ~ 264VAC 120 ~ 370VDC
47 ~ 63Hz
81.5% 86% 87.5% 88% 88.5% 89% 90% 91.5%
50ms / 230VAC 15ms / 115VAC at full load
1000ms, 30ms / 230VAC 1500ms, 30ms / 115VAC at full load
±5.0%
±1.0%
±5.0%
±5.0%
±1.0%
±5.0%
±5.0%
±1.0%
±5.0%
±3.0%
±1.0%
±3.0%
±3.0%
±1.0%
±3.0%
±3.0%
±1.0%
±3.0%
±3.0%
±1.0%
±3.0%
±2 5. %
±1.0%
±2 5. %
1.4A / 115VAC 1A / 230VAC
30A / 115VAC 65A / 230VAC
-30 ~ +60 (Refer to "Derating Curve")
20% ~ 90% RH non-condensing
-40 ~ +85, 10 ~ 95% RH
±0.03% / (0 ~ 40)
105 ~ 160% rated output power
Protection type : Hiccup mode, recovers automatically after fault condition is removed
Protection type : Shut down o/p voltage, re-power on to recover
Shut down o/p voltage, re-power on to recover
7.88 ~ 10.13V 9.45 ~ 12.15V 12.6 ~ 16.2V 15.75 ~ 20.25V 18.9 ~ 24.3V 25.2 ~ 32.4V 50.4 ~ 64.8V
5.25 ~ 6.75V
Touch current < 50 A/264VAC
I/P-O/P:4KVAC
I/P-O/P:100M Ohms / 500VDC / 25/ 70% RH
720K hrs min. MIL-HDBK-217F(25)
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
125*50*31.5mm (L*W*H)
0.32Kg; 40pcs/13.8Kg/1.05CUFT
Standard type P1J: 2.1ψ* 5.5ψ* 11mm, tuning fork type, center positive for stock ; Other type available by customer requested
See page 2 ; Other type available by customer requested
Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024, EN60601-1-2, EN61204-3 medical level, criteria A
ANSI/AAMI ES60601-1 / ES60601-1-11, TUV EN60601-1 / 60601-1-11 approved
Compliance to EN55011(CISPR11) class B, EN61000-3-2,3, FCC PART 15 class B
ISOLATION LEVEL Primary-Secondary: 2xMOPP
File Name:GSM60B-SPEC 2015-02-03
60W AC-DC Single Output Medical Adaptor GSM60B series
Derating Curve
AMBIENT TEMPERATURE ( )
LOAD (%)
(HORIZONTAL)
-30 0 2010 30 40
20
50
70
100
6050 70
Static Characteristics
INPUT VOLTAGE (VAC) 60Hz
80 10090 120110 160140 200180 240220 264
LOAD (%)
90
100
80
70
60
50
40
Mechanical Specification Case No. GSM60B Unit:mm
125
31.5
50
POWER LED
InsideOutside
ID 2.1 x OD 5.5
C"+"
70±10mm
11±0.5mm
U 2464 16AWG 1000 50mm for 5 ~ VL ±15
UL1185 16AWG 1500±50mm for 18 ~ 48V
Plug Assignment
Standard plug: P1J
Optional lock type plug: P2S
SWITCHCRAFT S761K plug equivalent
P/N OUTPUT
CENTER +
P1J
Installation Manual
Please refer to : http://www.meanwell.com/webnet/search/InstallationSearch.html
Mouser Electronics
Authorized Distributor
Click to View Pricing, Inventory, Delivery & Lifecycle Information:
Mean Well:
GSM60B05-P1J GSM60B07-P1J GSM60B09-P1J GSM60B12-P1J GSM60B15-P1J GSM60B18-P1J GSM60B24-
P1J GSM60B48-P1J