5
Ventilated Distribution Transformers
Contact Technical Services at (800) 377-4384 with any questions.
Visit our website at www.solahd.com.
201
kVA Catalog
Number
Type 3R
Weather Shield 1
Height
in (mm)
Width
in (mm)
Depth
in (mm)
Approx. Ship
Weight lbs (kg)
Design
Style 2
Elec
Conn 2
Primary Amps
@ 277 V
Secondary
Amps
15 ES12H15S WS-15 28.00 (711.2) 16.00 (406.4) 16.00 (406.4) 215.0 (97.52) 1 2 54.2 125/62.5
25 ES12H25S WS-15 28.00 (711.2) 16.00 (406.4) 16.00 (406.4) 250.0 (113.40) 1 2 90.3 208/104
Energy efcient dry-type transformers 600 Volt Class,
isolation type, single and three phase, 15 kVA through
500 kVA. Indoor and outdoor models available.
Accessories and Optional Design Styles
• Electrostatic shield for quality power
• Wall mounting brackets (500 lbs maximum) (Item WB1C)
• Weather Shields (UL Listed/NEMA Type 3R)
• Stainless Steel Enclosures
• Totally enclosed non-ventilated designs (TENV) (Non UL) *
• Open core and coil designs (UL Recognized)
• Copper Wound designs
• Low temperature designs
Features
• UL Listed/NEMA Type 3R ventilated outdoor enclosures
when used with optional weather shields
(order separately)
• UL Class 220°C insulation system, 150°C
temperature rise under full load
• Terminal board connections and spacious wiring
compartment
• Panel enclosure design reduces labor time. Wiring
diagram on inside front cover.
• High efciency for low cost operation
• Compliant to NEMA TP-1 Standards
• Single and three phase availability
• Fast delivery
• 10 year limited warranty
Certifications and Compliances
• Listed
- UL 1561
Selection Tables: Single Phase
Group 1: 240 x 480 Volt Primary, 120/240 Secondary, 60 Hz
kVA Catalog
Number
Type 3R
Weather Shield 1
Height
in (mm)
Width
in (mm)
Depth
in (mm)
Approx. Ship
Weight lbs (kg)
Design
Style 2
Elec
Conn 2
Primary
Amps
Secondary
Amps
15 ES5H15S WS-15 28.00 (711.2) 16.00 (406.4) 16.00 (406.4) 210.0 (95.25) 1 1 62.5/31.3 125/62.5
25 ES5H25S WS-15 28.00 (711.2) 16.00 (406.4) 16.00 (406.4) 245.0 (111.13) 1 1 104/52.1 208/104
37.5 ES5H37S WS-17 31.00 (787.4) 18.00 (457.2) 18.00 (457.2) 340.0 (154.22) 1 1 156/78 313/156
50 ES5H50S WS-17 31.00 (787.4) 18.00 (457.2) 18.00 (457.2) 415.0 (188.24) 1 1 208/104 416/208
75 ES5H75S WS-09 44.00 (1117.6) 23.00 (584.2) 21.00 (533.4) 610.0 (276.69) 1 1 313/156 625/313
100 ES5H100S WS-09 44.00 (1117.6) 23.00 (584.2) 21.00 (533.4) 705.0 (319.78) 1 1 417/208 833/417
167 ES5H167S WS-16 46.00 (1168.4) 26.00 (660.4) 24.00 (609.6) 980.0 (444.52) 1 1 695/348 1392/695
Notes:
1. Weather shields (set of two) must be ordered separately.
2. Design Styles and Electrical Connections can be found at the end of the Ventilated Distribution Transformers section.
Group 2 – 120/208/240/277 Volt Primary, 120/240 Secondary, 60 Hz
General Purpose
* Not all optional designs are listed. Contact Technical Services.
E25872