ENVIROMENT CHARACTERISTICS
TEST ITEM SPECIFICATION
High temperature △L/Lo≦±5% The sample shall be left for 96±4 hours in an atmospere with
storage a temperature of 85±2℃ and a normal humidity.
There shall be Upon completion of the measurement shall be made after the
no mechanical sample has been left in a normal temperature and normal
damage. humidity for 1 hour.
Low temperature △L/Lo≦±5% The sample shall be left for 96±4 hours in an atmosphere with
storage a temperature of -25±3℃.
There shall be Upon completion of the test, the measurement shall be made
no mechanical after the sample has been left in a normal temperature and
damage. normal humidity for 1 hour.
Change of △L/Lo≦±5% The sample shall be subject to 5 continuos cycles, such as shown
temperature in the table 2 below and then it shall be subjected to standard
There shall be stmospheric conditions for 1 hour, after which measurement
no other dama- shall be made.
ge of problems
table 2
Temperature Duration
-25±3℃
(Themostat No.1)
Standard
atmospheric
85±2℃
(Themostat No.2)
Standard
atmospheric
Moisture storage △L/Lo≦±5% The sample shall be left for 96±4 hours in a temperature of
40±2℃ and a humidity(RH) of 90~95%.
There shall be Upon completion of the test, the measurement shall be made
no mechanical after the sample has been left in a normal temperature and
damage. normal humidity more than 1 hour.
Test conditions:
The sample shall be reflow soldered onto the printed circuit board in every test.
Page-5/8
MSCDRI-63B-SERIES
No.1→No.2
No.2→No.1
1
2
3
4
30 min.
30 min.