IEC inlet filters FN 9233E High performance IEC inlet filter with earth line choke Rated currents up to 15A Excellent attenuation performance Integrated earth line choke Optional medical versions (B type) Snap-in versions (S and S1 type) Hot inlet versions (HI type) Technical specifications Maximum continuous operating voltage: Operating frequency: Rated currents: Approvals by rated current: High potential test voltage: Protection category: Temperature range (operation and storage): Design corresponding to: Flammability corresponding to: MTBF @ 40C/230V (Mil-HB-217F): 250VAC, 50/60Hz dc to 400Hz 1 to 15A @ 50C 1 to 10A (ENEC, CQC) 1 to 15A (UL, CSA) P -> E 2000VAC for 2 sec (standard types) P -> E 2500VAC for 2 sec (B types) P -> N 1000VAC for 2 sec IP40 according to IEC 60529 -25C to +85C (25/85/21) UL 1283, CSA 22.2 No. 8 1986, IEC/EN 60939 UL 94V-2 or better 1,710,000 hours Exceptional conducted attenuation an IEC inlet and mains filter with excellent performance, based on chokes with high filter attenuation in a small form factor. The saturation resistance and excellent thermal FN 9233E high performance power entry behavior. module offers additional EMI suppression on Rear/front or snap-in mounting. the earth line. Choosing the FN 9233E product Without earth line choke see FN 9233 line brings you the rapid availability of a standard filter associated with the necessary safety acceptances. Standard IEC connector filters are a practical solution helping you to pass EMI system approval in a short time. A for medical applications are designed to offer you the desired solution. For types without additional earth line choke please consult the FN 9233 data sheet. Cx R 2xL1 2xCy N N` E E` P` P Load Line L2 Typical applications Portable electrical and electronic equipment Small to medium-sized machines and household equipment Single-phase power supplies, switch-mode power supplies data sheet. Test and measurement equipment Optional low leakage currents for medical Medical equipment applications. Rack mounting equipment Wide mounting flanges available. Different output connections offering maximum flexibility for assembly. wide selection on amperage ratings, output connections, mounting possibilities and filters (CQC approval pending) Typical electrical schematic Features and benefits The FN 9233E IEC inlet filter combines Approvals Custom-specific versions are available on request. > Components > FN 9233E Filter selection table Filter Rated current @ 50C (25C) Leakage current* @ 250VAC/50Hz Inductance L1 L2 Capacitance Cx Cy Resistance Output connections R 9233Ex-1-06 9233Ex-3-06 9233Ex-6-06 9233Ex-8-06 9233Ex-10-06 9233Ex-12-06 9233Ex-15-06 9233Ex-12-06HI 9233Ex-15-06HI [A] 1 (1.2) 3 (3.5) 6 (7.2) 8 (10.6) 10 (11.6) 12 (12) 15 (15) 12 (12) 15 (15) [A] 373 373 373 373 373 373 373 373 373 [mH] 22.5 4.6 1.6 0.9 0.45 0.27 0.2 0.27 0.2 [mH] 0.4 0.4 0.4 0.4 0.4 0.1 0.1 0.1 0.1 [F] 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 [nF] 2.2 2.2 2.2 2.2 2.2 2.2 2.2 2.2 2.2 [k] FN FN FN FN FN FN FN FN FN FN FN FN FN FN FN FN FN FN 9233ExR-1-06 9233ExR-3-06 9233ExR-6-06 9233ExR-8-06 9233ExR-10-06 9233ExR-12-06 9233ExR-15-06 9233ExR-12-06HI 9233ExR-15-06HI 1 (1.2) 3 (3.5) 6 (7.2) 8 (10.6) 10 (11.6) 12 (12) 15 (15) 12 (12) 15 (15) 373 373 373 373 373 373 373 373 373 22.5 4.6 1.6 0.9 0.45 0.27 0.2 0.27 0.2 0.4 0.4 0.4 0.4 0.4 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 2.2 2.2 2.2 2.2 2.2 2.2 2.2 2.2 2.2 FN FN FN FN FN FN FN FN FN 9233ExB-1-06 9233ExB-3-06 9233ExB-6-06 9233ExB-8-06 9233ExB-10-06 9233ExB-12-06 9233ExB-15-06 9233ExB-12-06HI 9233ExB-15-06HI 1 (1.2) 3 (3.5) 6 (7.2) 8 (10.6) 10 (11.6) 12 (12) 15 (15) 12 (12) 15 (15) 2 2 2 2 2 2 2 2 2 22.5 4.6 1.6 0.9 0.45 0.27 0.2 0.27 0.2 0.4 0.4 0.4 0.4 0.4 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 * -06 -06 -06 -06 -06 -06 -06 -06 -06 [g] 46 46 46 46 46 46 46 46 46 1000 1000 1000 1000 1000 1000 1000 1000 1000 -06 -06 -06 -06 -06 -06 -06 -06 -06 46 46 46 46 46 46 46 46 46 1000 1000 1000 1000 1000 1000 1000 1000 1000 -06 -06 -06 -06 -06 -06 -06 -06 -06 46 46 46 46 46 46 46 46 46 Maximum leakage under normal operating conditions. Note: if the neutral line is interrupted, worst case leakage could reach twice this level. Product selector FN 9233Exx-yy-..HI-zz Snap-in range for S version only Blank: Snap-in range 0.7 to 1.5mm 20: Snap-in range 1.5 to 2.2mm Blank: Standard IEC inlet type C14 HI: Hot IEC inlet type C16 (12 and 15A types only) 06: Faston 6.3 x 0.8mm (spade/soldering) 1 to 15: Rated current Blank: Standard version R: Bleed resistor B: Medical version (with bleed resistor and without Y2-capacitor) Blank: Standard housing with mounting flanges U: Housing with wider mounting flanges S: Snap-in version, snapper on vertical side S1: Snap-in version, snapper on horizontal side For example: FN 9233E-15-06, FN 9233ES1B-10-06-20, FN 9233ER-12-06HI, FN 9233EUB-8-06-20 Weight > Components > FN 9233E Typical filter attenuation Per CISPR 17; A = 50/50 sym; B = 50/50 asym; C = 0.1/100 sym; D = 100/0.1 sym 1 and 3A types 6 to 10A types 12 and 15A types Mechanical data FN 9233E FN 9233E-HI B B 6.3 x 0.8 A C E A C J E H F G D I B 6.3 x 0.8 A 6.3 x 0.8 G A J E F D Installation B T 6.3 x 0.8 S C J E H F G Panel cut out M R D I A J E G I FN 9233EU C F G FN 9233ES1 B P J H I D FN 9233ES N 6.3 x 0.8 S S F D I > Components > FN 9233E Dimensions A B C D E F G H I J M N P R S T* T* * FN 9233E FN 9233EU FN 9233ES FN 9233ES1 FN 9233E-HI 48 22.5 40 0.2 46.8 27.8 5.5 20.1 O3.3 14 13.3 R3 21.5 28.5 M3 90 51.85 25 40 0.2 46.8 27.8 5.5 20.1 O3.3 14.1 13.3 R3 21.5 28.5 M3 90 29.9 22.4 29.9 22.4 46.8 27.8 5.5 20.1 46.8 27.8 5.5 20.1 14 13.3 R 1.5 20.8 29.4 14 13.3 R 1.5 21.9 28.5 48 22.5 40 0.2 46.8 27.8 5.5 20.1 O3.3 14 13.3 R3 21.5 28.5 M3 90 0.7 - 1.5 1.5 - 2.2 0.7 - 1.5 1.5 - 2.2 For selecting the panel thickness, please refer to the filter selector table. All dimensions in mm; 1 inch = 25.4mm Tolerances according: ISO 2768-m / EN 22768-m Your local partner: To find your local partner within Schaffner's global network, please go to www.schaffner.com May 2008