Mini Contactor Relays 4-pole J7KNA-AR ) Main contactor * AC & DC operated * 4-, 6- and 8-pole versions in different configurations * Mirror contacts * Screw fixing and snap fitting (35 mm DIN rail) * Rated current = 10A (Ith) * Suitable for electronic devices (DIN 19240) * Finger proof (BGV A2) Accessories * 2- and 4-pole additional auxiliary contacts in different configurations Approved Standards Standard Guide No (US,C) UL NKCR, NKCR7 IEC 947-5-1 see page 95 VDE 0660 EN 60947-5-1 Ordering Information Model Number Legend 1. Mini Contactor Relays J7KNA-##-##-##### 1 2 3 4 1) 2) 3) 4) Mini Contactor AR: Contactor Relay Combination of NO / NC contacts 22: 2 NO 2 NC 31: 3 NO 1NC 40: 4 NO 0NC Coil voltage (AC operated) 24: AC24V 50/60Hz 48: AC48V 50Hz 110: AC110-115V 50Hz,AC120-125V 60Hz 230: AC220-230V 50Hz,AC240V 60Hz 240: AC230-240V 50Hz 400: AC380-400V 50Hz,AC440V 60Hz 415: AC400-415V 50Hz 550: AC525-550V 50Hz,AC600V 60Hz Coil voltage (DC operated) 24D: DC24V 48D: DC48V 60D: DC60V 110D: DC110V 125D: DC125V 24VS: DC24V with diode 48VS: DC48V with diode 110VS: DC110V with diode 125VS: DC125V with diode 2. Aux. Contact Modules for Mini Motor Contactor Relays J73KN-##-##-# 1 2 3 4 1) 2) 3) Auxiliary Contact Modules A: for mini contactor relays Combination of NO/NC contacts 11: 1 NO 1 NC 02: 0 NO 2 NC 22: 2 NO 2 NC 40: 4 NO 0 NC Mini Contactor Relays 4-pole J7KNA-AR 7 System overview Mini Contactor Relays 4-pole AC Operated Contacts NO NC Distinc. Number acc. to DIN EN 50011 Ratings AC15 230V A Type 400V A Thermal Rated Current Ith A 24 230 2 10 J7KNA-AR-40 24 Coil voltage 1) 24V 50/60Hz 220-230V 50Hz Pack Weight pcs. kg/pc. 10 0,16 10 0,16 10 0,16 4-pole, With Screw Terminals 4 - 40E 3 J7KNA-AR-40 230 3 1 31E 3 2 10 J7KNA-AR-31 24 J7KNA-AR-31 230 2 2 22E 3 2 10 J7KNA-AR-22 24 J7KNA-AR-22 230 1) Other coil voltages see page 10 DC Solenoid Operated Contacts NO NC Distinc. Number acc. to DIN EN 50011 Ratings AC15 230V A Type Pack Weight 400V A Thermal Rated Current Ith A Coil voltage 24V DC 2,5W pcs. kg/pc. 4-pole, With Screw Terminals 4 - 40E 3 2 10 J7KNA-AR-40 24D (-VS)1) 10 0,19 3 1 31E 3 2 10 J7KNA-AR-31 24D (-VS)1) 10 0,19 2 2 22E 3 2 10 J7KNA-AR-22 24D (-VS)1) 10 0,19 Type Pack Weight 1) with built-in coil suppressor (diode + zener diode) Auxiliary Contact Blocks for Contactor Relays J7KNA-AR 8 Contacts Ratings NO NC AC15 230V A 400V A Thermal Rated Current Ith A pcs. kg/pc. 1 1 3 2 10 J73KN-A-11 10 0,04 - 2 3 2 10 J73KN-A-02 10 0,04 4 - 3 2 10 J73KN-A-40 10 0,04 2 2 3 2 10 J73KN-A-22 10 0,04 Mini Contactor Relays 4-pole J7KNA-AR System overview Mini Contactor Relays 4-pole AC Operated Wiring Diagrams Distinc. Number acc. to DIN EN 50011 Auxiliary Contact Blocks NC Contactor Relay with Auxiliary Contact Contacts suitable for Electronic Block Circuits according to DIN 19240 Distinc. Number for rated voltage 24V DC according to (test ratings 17V DC, 5mA) DIN EN 50011 NO NC Mirror contacts Type NO J73KN-A-11 1 1 51E 5 1 J73KN-A-02 0 2 42E 4 2 J73KN-A-40 4 0 80E 8 0 J73KN-A-22 2 2 62E 6 2 J73KN-A-11 1 1 42Y 4 2 J73KN-A-02 0 2 33Y 3 3 J73KN-A-40 4 0 71Y 7 1 J73KN-A-22 2 2 53Y 5 3 J73KN-A-11 1 1 33Y 3 3 J73KN-A-02 0 2 24Y 2 4 J73KN-A-40 4 0 62Y 6 2 J73KN-A-22 2 2 44Y 4 4 4-pole, With Screw Terminals 40E 31E 22E Preferable combinations with distinctive letter E" according to DIN EN 50011 DC Solenoid Operated Wiring Diagrams Distinc. Number acc. to DIN EN 50011 Auxiliary Contact Blocks Contactor Relay with Auxiliary Contact Type NO Block Distinc. Number according to DIN EN 50011 J73KN-A-11 1 1 51E 5 1 J73KN-A-02 0 2 42E 4 2 J73KN-A-40 4 0 80E 8 0 J73KN-A-22 2 2 62E 6 2 J73KN-A-11 1 1 42Y 4 2 J73KN-A-02 0 2 33Y 3 3 J73KN-A-40 4 0 71Y 7 1 J73KN-A-22 2 2 53Y 5 3 J73KN-A-11 1 1 33Y 3 3 J73KN-A-02 0 2 24Y 2 4 J73KN-A-40 4 0 62Y 6 2 J73KN-A-22 2 2 44Y 4 4 NC NO NC 4-pole, With Screw Terminals 40E 31E 22E Preferable combinations with distinctive letter E" according to DIN EN 50011 Auxiliary Contact Blocks for Contactor Relays J7KNA-AR Wiring diagrams J73KN-A-11 J73KN-A-02 J73KN-A-40 J73KN-A-22 Mini Contactor Relays 4-pole Contacts suitable for Electronic Circuits according to DIN 19240 for rated voltage 24V DC (test ratings 17V DC, 5mA) Mirror contacts J7KNA-AR 9 Specifications Coil Voltages Suffix Voltage Marking Rated Control Voltage Us to contactor type e.g. at the coil range for 50Hz J7KNA-AR-40-24 for 50Hz for 60Hz min V V V. max V. min V. max V. 12 12 12 11 12 12 12 24 24 24 22 24 24 24 42 42 42 38.5 42 42 42 48 48-50 48 48 50 48 50 60 60 60 52 66 54 60 90 90-95 100-105 90 95 100 105 95 95-100 105-110 95 100 105 110 100 100 110-115 100 105 110 115 105 105-110 115-120 105 110 115 120 110 110-115 120-125 110 115 120 125 200 200 205 210 220 Suffix Voltage Marking Rated Control Voltage Us to contactor type e.g. at the coil range for 50Hz J7KNA-AR-40- 230 for 50Hz for 60Hz min V V V. max V. min V. max V. 210 205-215 220-230 205 215 220 230 220 210-220 230-240 210 220 230 240 230 220-230 240 220 230 240 250 240 230-240 230 240 250 260 400 380-400 440 380 400 415 440 500 475-500 520-545 475 500 520 545 550 525-550 600 550 570 600 210-220 195 525 60Hz 60Hz Standard voltages in bold type letters. Coil not exchangeable 10 Mini Contactor Relays 4-pole J7KNA-AR Engineering data and Characteristics Mini Contactor Relays Data according to IEC 947-5-1, VDE 0660, EN 60947-5-1 DC DC + Diode Auxiliary Contacts Type J7KNA-AR... AC J7KNA-AR...D J7KNA-AR...VS J73KN-A... Rated insulation voltage Ui V AC 690*1 690*1 690*1 690*1 40C A 10 10 10 10 60C A 6 6 6 6 at Ith W 0.5 0.5 0.5 0.5 220-240V A 3 3 3 3 380-415V A 2 2 2 2 440V A 1.6 1.6 1.6 1.6 Thermal rated current Ith to 690V Ambient temperature Power loss per pole Utilization category AC15 Rated operational current Ie 500V A 1.2 1.2 1.2 1.2 660-690V A 0.6 0.6 0.6 0.6 Utilization category DC13 Rated operational current Ie 60V A 2 2 2 2 110V A 0.4 0.4 0.4 0.4 220V A 0.1 0.1 0.1 0.1 open C -40 to +60 (+90)*2 enclosed C -40 to +40 C -40 to +90 Maximum ambient temperature Operation Storage Short circuit protection short-circuit current 1kA, contact welding not accepted max. fuse size gL (gG) A 20 20 20 20 inrush VA 25 - - - sealed VA 4-5 - - - W 1.2 - - - Power consumption of coils AC operated DC operated inrush W - 2.5 2.5 - sealed W - 2.5 2.5 - 0.85 - 1.1 0.8 - 1.1 0.8 - 1.1 - - Operation range of coils in multiples of control voltage Us *3,*4 Switching time at control voltage U 10% s AC operated DC operated make time ms 15 - 25 - - release time ms 8 - 25 - - - arc duration ms 10 -15 - - - make time ms - 15 - 19 15 - 19 - release time ms - 8 - 25 8 - 25 - arc duration ms - 10 -15 10 -15 - Cable cross-section all connectors solid mm 0.75 - 2.5 0.75 - 2.5 0.75 - 2.5 0.75 - 2.5 flexible mm 0.75 - 2.5 0.75 - 2.5 0.75 - 2.5 0.75 - 2.5 mm 0.5 - 1.5 0.5 - 1.5 0.5 - 1.5 0.5 - 2.5 2 2 2 18 - 14 18 - 14 18 - 14 flexible with multicore cable end Clamps per pole 2 solid or stranded AWG 18 - 14 *1) Suitable at 690V for: earthed-neutral systems, overvoltage category I to IV, pollution degree 3 (standard-industry): Uimp = 8kV. Data for other conditions on request. *2) With reduced control voltage range 0.9 up to 1.0 x Us and with reduced thermal rated current Ith to Ie/AC15 *3) Summary switching time = release time + arc duration *4) Release time of NC make time of NO increase when suppressor units for voltage peak protection are used (Varistor, RC-units, Diode units). Mini Contactor Relays 4-pole J7KNA-AR 11 Mini Contactor Relays for North America Data according to UL508 Main Contacts (cULus) Type J7KNA-AR... J73KN-A... Rated operational current "General Use" A 10 10 Rated operational power of three-phase motors 115V hp - - at 60Hz (3ph) 200V hp - - 230V hp - - 460V hp - - 575V hp - - Rated operational power of of AC motors 115V hp - - at 60Hz (1ph) 200V hp - - 230V hp - - Fuses Suitable for use on a capability of delivering not more than rms Rated voltage A - - A - - V - - V AC 600 Auxiliary Contacts (cULus) 600 heavy pilot duty AC A600 A600 standard pilot duty DC Q600 Q600 Dimensions AC and DC operated with screw terminals Auxiliary Contact Blocks J7KNA-AR... J73KN-A... Do not use/install these products before having read the applicable precautions as listed in Cat. No. J09-EN-01 available from www.europe.omron.com or on request from OMRON local sales office. ALL DIMENSIONS SHOWN ARE IN MILLIMETERS. Cat. No. J04E-EN-01A 12 In the interest of product improvement, specifications are subject to change without notice. Mini Contactor Relays 4-pole J7KNA-AR