PART NUMBER: CMA-4544PF-W page 1 of 4 date 06/2008 DESCRIPTION: electret condenser microphone SPECIFICATIONS directivity sensitivity (S) sensitivity reduction (S-Vs) operating voltage output impedance (Zout) operating frequency (f) current consumption (IDSS) signal to noise ratio (S/N) operating temperature storage temperature dimensions weight material terminal RoHS omnidirectional -44 2 dB f = 1KHz, 1Pa -3 dB f = 1KHz, 1Pa 3 V dc (standard), 10 V dc (max.) 2.2 K f = 1KHz, 1Pa 20 ~ 20,000 Hz 0.5 mA max. Vs = 3.0 V dc 60 dBA f = 1KHz, 1Pa -20 ~ +70 C -20 ~ +70 C o9.7 x 4.5 mm 0.80 g max. Al pin type (hand soldering only) yes note: We use the "Pascal (Pa)" indication of sensitivity as per the recomendation of I.E.C. (International Electrotechnical Commission). The sensitivity of "Pa" will increase 20dB compared to the "ubar" indication. Example: -60dB (0dB = 1V/ubar) = -40dB (1V/Pa) 0dB = 1V/Pa Vs = 3.0 ~ 2.0 V dc RL = 2.2K A-weighted APPEARANCE DRAWING 20050 SW 112th Ave. Tualatin, Oregon 97062 phone 503.612.2300 fax 503.612.2383 PART NUMBER: CMA-4544PF-W page 2 of 4 date 06/2008 DESCRIPTION: electret condenser microphone MEASUREMENT CIRCUIT FREQUENCY RESPONSE CURVE 20050 SW 112th Ave. Tualatin, Oregon 97062 phone 503.612.2300 fax 503.612.2383 page 3 of 4 date 06/2008 DESCRIPTION: electret condenser microphone PART NUMBER: CMA-4544PF-W MECHANICAL CHARACTERISTICS item soldering heat resistance PCB wire pull strength vibration drop test test condition evaluation standard Lead terminals are immersed in solder bath of No interference in operation. 270 5C for 2 0.5 seconds. The pull force will be applied to double lead wire: No damage or cutting off. Horizontal 4.9N (0.5kg) for 30 seconds The part will be measured after applying a vibration amplitude of 1.5 mm with 10 to 55 Hz band of vibration frequency to each of the After any tests, the sensitivity 3 perpendicular directions for 2 hours. should be within 3dB compared The part will be dropped from a height of to the initial measurement. 1 m onto a 20 mm thick wooden board 3 times in 3 axes (X, Y, Z) for a total of 9 drops. ENVIRONMENT TEST item high temp. test low temp. test humidity test temp. cycle test test condition After being placed in a chamber at +70C for 72 hours. After being placed in a chamber at -20C for 72 hours. After being placed in a chamber at +40C and 905% relative humidity for 240 hours. The part shall be subjected to 10 cycles. One cycle will consist of: evaluation standard The part will be measured after being placed at +25C for 6 hours. After any tests, the sensitivity should be within 3dB compared to the initial measurement. TEST CONDITIONS standard test condition judgement test condition a) temperature: +5 ~ +35C a) temperature: +25 2C b) humidity: 45 - 85% b) humidity: 60 - 70% c) pressure: 860-1060 mbar c) pressure: 860-1060 mbar 20050 SW 112th Ave. Tualatin, Oregon 97062 phone 503.612.2300 fax 503.612.2383 PART NUMBER: CMA-4544PF-W page 4 of 4 date 06/2008 DESCRIPTION: electret condenser microphone PACKAGING 20050 SW 112th Ave. Tualatin, Oregon 97062 phone 503.612.2300 fax 503.612.2383