APPLICATIONS MLT * 3/8 INCH DIAMETER LINEAR POSITION TRANSDUCER The Models MLT are small diameter linear position transducers rugged enough to withstand the hostile environment of the factory. Using a proprietary dual wiper, internal ball joint and the MystR(R) conductive plastic film the MLT provides usable output at high vibration levels for long periods. MLT Transducers use precious metal wipers to further enhance reliability. Intrinsically Safe for Class I, II, and III Division 1, Groups A, B, C, D, E, F and G for Hazardous (indoor/outdoor) NEMA 4 locations. V max = 30 V, I max = 100 mA, Ci = 0, uF, Li, = 0 mH. * * * * * * * * * BENEFITS 0.375 inch diameter Dual wiper design Extruded wiper block guides MystR(R) plastic element Internal spring loaded ball joint Anodized extruded aluminum housing Stainless steel shaft Precious metal contact Absolute continuous measurement * * * * * * * * * Fits into tight spaces, clamps easily to cylinders Improves shock and vibration performance Smooth quiet motion; extends operating life Tested up to one billion operations Less error from shaft misalignment Tolerates clamping loads Full performance in hostile environments Low noise level over entire life Accurate position at power up HOW TO ORDER MLT 0R5 N 0750 F 5 C Model Electrical Travel* Unit of Measure Total Resistance* Termination C = Cable 0R5 001 002 003 004 005 006 = = = = = = = 750 1500 3000 4500 6000 7500 9000 N = Inches Shaft 5 = 4-40 Thread Linearity B = 0.1% F = 1.0% (Best possible on 0.5 in. device) D = 0.25% (Best possible on 1.0 in. device) 0750, 1500, 3000, 4500, 6000, 7500, 9000 Note: Not all combinations are available. Minimum quantity orders apply. Contact the factory for more details. * Note: The Electrical Travel correlates to the Total Resistance (Ohms). MLT SERIES FEATURES SMALL DIAMETER LINEAR POSITION TRANSDUCER * MEDICAL EQUIPMENT * HOSPITAL BEDS * LINEAR ACTUATORS * ANIMATED CHARACTERS * GAUGING * WOODWORKING GUIDES * FLUID FLOW METERS * SEISMOLOGY * SEMI CONDUCTOR PROCESSING MLT SERIES * SMALL DIAMETER LINEAR POSITION TRANSDUCER TECHNICAL SPECIFICATIONS MECHANICAL Total Mechanical Travel 0.55 to 6.05 in. (min) 13.9 to 153.7 mm (min) Starting Force 1.0 oz (max) Shock xx.xx = inches (xx.x) = mm 50 g 11 ms half sine Vibration Life DIMENSIONS One Billion dither operations 3/8" [9.53] ELECTRICAL Theoretical Electrical Travel (1 inch increments) 0.5 to 6 in. (12.7 to 152.4 mm) Independent Linearity See How to Order Total Resistance 1500 Ohms per inch electrical travel Operating Temperature -40 to 80C (-40 to 176F) Resolution Insulation Resistance #4-40 UNC-2A Thd x .50 [12.7] long 1/8" x .063 [4.75 x 1.6] 1/8" [3.18] 3 - conductor cable #26 AWG [65/44] 12.0 [305] long min. (color coded per schematic) 20% Resistance Tolerance 3/4" [19.05] (Retracted) Housing length 'X' (Electrical Travel +1.2 [30.48]) 20 g rms 5 Hz to 2 KHz (Black) Ground (Red) V-in Infinite Shaft Extended 500 M Ohms @ 500 Vdc Dielectric Strength Max. Applied Voltage Backlash (Orange) V-out 1000 V rms 30 Vdc Connect to High Impedance Circuit 0.0005 in. max <1 A Recommended Wiper Current Caution: Do not test on an Ohm Meter on the Rx 1 scale or other current devices. Model Electrical Travel in inches Total Resistance Ohms Housing Length `X' in inches Weight in grams MLT0R5 MLT001 0.5 750 1.7 11 1.0 1500 2.2 14 MLT002 2.0 3000 3.2 20 MLT003 3.0 4500 4.2 23 MLT004 4.0 6000 5.2 28 MLT005 5.0 7500 6.2 30 MLT006 6.0 9000 7.2 31 Caution: Excessive Wiper Current can cause Output errors or damage. Caution: Zero shaft side load is recommended to achieve maximum life. SPECIALS AND ACCESSORIES * Other Mechanical Travels * Other Resistance Values * Other Electrical Travels * Rod-end bearing * Metric Shaft Adapter WARRANTY/REMEDY Honeywell warrants goods of its manufacture as being free of defective materials and faulty workmanship. Contact your local sales office for warranty information. If warranted goods are returned to Honeywell during the period of coverage, Honeywell will repair or replace without charge those items it finds defective. The foregoing is Buyer's sole remedy and is in lieu of all other warranties, expressed or implied, including those of merchantability and fitness for a particular purpose. Specifications may change without notice. The information we supply is believed to be accurate and reliable as of this printing. However, we assume no responsibility for its use. While we provide application assistance personally, through our literature and the Honeywell web site, it is up to the customer to determine the suitability of the product in the application. Item # 1124900 M.G. 10/01 Rev. A Sensing and Control Honeywell 100 Discovery Way Acton, MA 01720 USA Tel: (877) 384-1300; Fax: (978) 263-0630 www.honeywell.com/sensing/products/di