The Fluke 576
Photographic
Non-contact
Thermometer
Infrared temperature
measurement with
digital photos
Technical Data
Introducing the world’s
first precision infrared (IR)
thermometer with integral
digital photography. For the
most complete temperature
documentation solution,
predictive maintenance
professionals use the Fluke
576 precision IR thermometer.
inset
application photo
to come
Measure
Photograph
Document
Any infrared
thermometer can
measure temperature,
but only the Fluke 576
thermometer measures
temperature while
digitally photographing
the measured area and its
surroundings.
The proof is in the picture!
Temperature measurement
locations are instantly
captured in a digital photo
with a time and date stamp
in the image. The laser sighting
pinpoints the exact measurement
location, without the need for a view
finder.
Make sure the inspection was done
properly. Download images and data to the
PC software and double-check all work.
Ensure consistency of repeated measurements by using
prior photos as a reference—position the laser sighting as
shown in the photo to assure the measurement area is the
same.
Create customized company reports with the software,
data and photos. Just insert information from Fluke 576 data
files into reports for fast, professional results.
Log temperature and take
photo with the Fluke 576.
Measurements and
documentation as
simple as 1-2-3
Download data from the
Fluke 576 to a computer.
View, graph and generate
reports with the software.
3
Focus the camera for near
or distant photos using the
focus ring. With the Fluke
576 thermometer in “log
mode,” pull and release
the trigger. After taking a
successful measurement and
a photograph, the Fluke 576
thermometer prepares to
record the temperature and
image of the next location.
In low light situations, the
Fluke 576 thermometer can
automatically illuminate
the subject with a built-in flash.
21
inset
application photo to
come
Advanced Sighting
Accurate measurements depend in part on
accurately sighting a target. Fluke 570 series
thermometers are the only thermometers with
a sighting system designed to precisely track
the infrared path as seen by the sensors. This
enables the advanced coaxial three-dot laser
sighting to accurately show both the center
and the edges of the spot being measured,
regardless of the thermometer’s distance from
the target.
This laser sighting also appears twice as
bright to the human eye as normal lasers
(while maintaining the same safety rating as
less bright lasers), making precise sighting
easier in a variety of lighting conditions and
distances.
Advanced display
Icons for camera active, flash
active, and flash charging,
and indication of photos
remaining
Confirmation of a successful
photo taken
30 preset common material
emissivities
Adjustable emissivity values
(0.01 increments)
100 location logging
capability
Customized log location
names and alarms
Close Focus Option
The Close Focus (CF) option lets
you accurately measure very
small areas at the focus point
– where the IR beam narrows.
Paired with an advanced
coaxial laser sighting system,
extremely small objects 6 mm
(0.24 in) at 300 mm (11.4 in)
can be easily measured. Ideal
for electrical maintenance and
refrigeration troubleshooting.
Visualize and systematically maintain and analyze temperature data
using Windows compatible software. Export data and images in
common file formats for easy compatibility with standard programs.
Software for condition monitoring
and process control
Data log tabular view
See photos next to
temperature data
Create identifiable location
names
Tailor high/low alarms to
location
View minimum, maximum
and average temperatures
Graph
Visually review data
and spot trends
Quickly compare
temperatures of up to
5 locations
Display infrared temperatures
over time
Store up to 10,000 data
points in a file
Live temperature
reporting
Record photos while in
continuous measuring mode
Set the Fluke 576 IR
thermometer to take photos
when high/low alarms
exceeded
Easily view photos through
indications on temperature
graph
Simultaneously see
temperature trend and photo
Report creation
Import and paste
temperature data and
photographs to quickly
create multiple reports
Add impact to reports
with recorded photos
Fluke Corporation
PO Box 9090, Everett, WA USA 98206
Fluke Europe B.V.
PO Box 1186, 5602 BD
Eindhoven, The Netherlands
For more information call:
In the U.S.A. (800) 443-5853 or
Fax (425) 446-5116
In Europe/M-East/Africa (31 40) 2 675 200 or
Fax (31 40) 2 675 222
In Canada (800) 36-FLUKE or
Fax (905) 890-6866
From other countries +1 (425) 446-5500 or
Fax +1 (425) 446-5116
Web access: http://www.fluke.com/
©2005 Fluke Corporation. All rights reserved.
Printed in U.S.A. 4/2005 2437668 D-US-N Rev A
Fluke. Keeping your world
up and running.
Specifications
Thermometer
Temperature range -30 °C to 900 °C (-25 °F to 1600 °F)
Accuracy ±0.75 % of reading or ±0.75 ºC (±1.5 ºF) whichever is greater
(assumes ambient operating temperature of 23 ºC (73 ºF))
Repeatability ±0.5% of reading or ±1 ºC (±2 ºF), whichever is greater
Response time 250 mSec (95% of reading)
Spectral response 8 µm to 14 µm, thermopile detector
Distance to Spot (D:S) 60:1 (50:1 with Close Focus Option)
Minimum measurement diameter 19 mm (0.76 in) [6mm (0.24 in) with Close Focus Option]
Display resolution 0.1 ºC of reading up to 900 ºC (0.2 ºF up to 999.8 ºF)
Temperature display ºC or ºF selectable
Ambient operating temperature 0 ºC to 50 ºC (32 °F to 122 ºF )
Relative humidity 10 % to 90 % RH non-condensing at up to 30 °C (86 °F)
Storage temperature -20 ºC to 50 ºC (-25 ºF to 122 ºF)
Tripod mount 1/4-20 UNC
Power 2 AA batteries
Battery life 8 hours (13 hours with photographic mode off)
50 photos, with flash (200 photos, without flash)
Laser Class II 3-dot laser sighting (meets IEC Class 2 and FDA Class II
requirements)
Maximum and minimum temperature
displayed
Differential and average temperature
Audible/visible high and low alarm
Bar graph display
Adjustable emissivity
(from 0.1 to 1.0 by 0.01)
100 points data logging
Display hold
LCD backlit
PC Software operating systems Windows 2000 and XP
Data graphing and photo viewing
software (Windows® compatible)
Data output: USB or 1 mV
per degree (ºC or ºF)
Weight 580 g (1 lb 4 oz)
Camera
Maximum number of 26
640 x 480 pixel photos (VGA)
Maximum number of 100
320 x 240 pixel photos (1/4 VGA)
Recharge time for flash 5 sec
Camera lens 6 mm (0.24 in) approximately equal to 42 mm lens on a
35 mm camera
Close-up distance focal point 200 mm (7.87 in)
Far distance focal point Infinity
Light sensitivity 6 lux w/out flash
Variable shutter speed < 1/15 sec (with flash at 1/15 sec fixed)
Data interface USB 1.1
Image file format .jpg files
Warranty 2 years, conditional*
Ordering Information
Options
Close focus
NIST calibration certificate
Accessories
Analog cable
Included with Fluke 576 unit:
User’s guide (on CD)
Hardshell carrying case
PC software
USB computer cable
Thermocouple K probe
Padded pouch with belt clip
Analog cable accessory
* Warranty duration may vary by country.