TOROIDAL TRANSFORMER 50/60HZ, 115/230 VAC, ENCAP
|||||||||||||||
ACTT-0xxx-xx
STANDARD SPECIFICATIONS: OPTIONS AND PART IDENTIFICATION:
APPLICATIONS:
FEATURES:
size varies
Pb
RoHS
Compliant
PARAMETERS
ABRACON P/N: ACTT-0xxx-xx Series
2 x 115 V
Operating temperature: -40°C to + 120°C
Storage temperature:
Input Voltage: -40°C to + 105°C
ABRACON IS
ISO 9001 / QS 9000
CERTIFIED
ABRACON IS
ISO 9001 / QS 9000
CERTIFIED
30332
Esperanza, Rancho Santa Margarita, California
92688
tel 949-546-8000 | fax 949-546-8001 | www.abracon.com
Revised: 02.22.08
Visit www.abracon.com for Terms & Conditions of Sale
• Multilayer monolithic construction yields high reliability
• Fully encapsulated; magnetically shielded
• Low profile; High efficiency
• Low standby current
•
Low magnetic stray field emissions
•
Safety approved-UL506,UL5085-1&2 for general purpose,
UL6500/UL60065 for audio/video apparatus
•
High ambient operating temperature (+60°C maximum)
•
Primary – Dual primary (115V/230V 50/60Hz)
•
Power – 1.6VA to 85VA; Dielectric Strength – 4000Vrms
•
Secondary – Series or parallel
•
Insulation Class – Class F (155°C)
• Medical Equipment
• Test Equipment
• Media and Advanced Audio Equipment
• Broadcast Sound Systems
Part# Series Parallel
V (C.T.) mA ( RMS) V mA (RMS) Part# Series Parallel
V (C.T.) mA ( RMS) V mA (RMS)
ACTT-0016-12 12 133 6 266 ACTT-0032-12 12 266 6 532
ACTT-0016-14 14 114 7 228 ACTT-0032-14 14 229 7 458
ACTT-0016-18 18 89 9 178 ACTT-0032-18 18 178 9 356
ACTT-0016-24 24 67 12 134 ACTT-0032-24 24 133 12 266
ACTT-0016-30 30 53 15 106 ACTT-0032-30 30 107 15 214
ACTT-0016-36 36 44 18 88 ACTT-0032-36 36 89 18 178
ACTT-0016-44 44 36 22 72 ACTT-0032-44 44 73 22 146
ACTT-0016-48 48 33 24 66 ACTT-0032-48 48 66 24 132
ACTT- -
Power Code
Please see Section 5,
i.e. 0016=1.6VA
Series Voltage Value
Please refer to the
tables
ACTT-0050-12 12 416 6 832 ACTT-0070-12 12 583 6 1166
ACTT-0050-14 14 357 7 714 ACTT-0070-14 14 500 7 1000
ACTT-0050-18 18 278 9 556 ACTT-0070-18 18 389 9 778
ACTT-0050-24 24 208 12 416 ACTT-0070-24 24 292 12 584
ACTT-0050-30 30 167 15 334 ACTT-0070-30 30 233 15 466
ACTT-0050-36 36 139 18 278 ACTT-0070-36 36 194 18 388
ACTT-0050-44 44 114 22 228 ACTT-0070-44 44 159 22 318
ACTT-0050-48 48 104 24 208 ACTT-0070-48 48 145 24 290
ACTT-0100-12 12 0.833 6 1.666 ACTT-0150-12 12 1.250 6 2.500
ACTT-0100-14 14 0.714 7 1.428 ACTT-0150-14 14 1.071 7 2.142
ACTT-0100-18 18 0.556 9 1.112 ACTT-0150-18 18 0.833 9 1.666
ACTT-0100-24 24 0.417 12 0.834 ACTT-0150-24 24 0.625 12 1.250
ACTT-0100-30 30 0.333 15 0.666 ACTT-0150-30 30 0.500 15 1.000
ACTT-0100-36 36 0.278 18 0.556 ACTT-0150-36 36 0.417 18 0.834
ACTT-0100-44 44 0.227 22 0.454 ACTT-0150-44 44 0.341 22 0.682
ACTT-0100-48 48 0.208 24 0.416 ACTT-0150-48 48 0.312 24 0.624
Part# Series Parallel
V (C.T.) mA ( RMS) V mA (RMS)
Part# Series Parallel
V (C.T.) mA ( RMS) V mA (RMS)
Part# Series Parallel
V (C.T.) mA ( RMS) V mA (RMS)
Part# Series Parallel
V (C.T.) mA ( RMS) V mA (RMS)
UL 506, 5085-1&2, UL6500/60065
APPROVED
TOROIDAL TRANSFORMER 50/60HZ, 115/230 VAC, ENCAP
|||||||||||||||
ACTT-0xxx-xx
size varies
Pb
RoHS
Compliant
ABRACON IS
ISO 9001 / QS 9000
CERTIFIED
ABRACON IS
ISO 9001 / QS 9000
CERTIFIED
30332
Esperanza, Rancho Santa Margarita, California
92688
tel 949-546-8000 | fax 949-546-8001 | www.abracon.com
Revised: 02.22.08
Visit www.abracon.com for Terms & Conditions of Sale
ACTT-0250-12 12 2.083 6 4.166 ACTT-0350-12 12 2.916 6 5.832
ACTT-0250-14 14 1.785 7 3.570 ACTT-0350-14 14 2.500 7 5.000
ACTT-0250-18 18 1.377 9 2.754 ACTT-0350-18 18 1.944 9 3.888
ACTT-0250-24 24 1.041 12 2.082 ACTT-0350-24 24 1.458 12 2.916
ACTT-0250-30 30 0.832 15 1.664 ACTT-0350-30 30 1.167 15 2.334
ACTT-0250-36 36 0.694 18 1.388 ACTT-0350-36 36 0.972 18 1.944
ACTT-0250-44 44 0.568 22 1.136 ACTT-0350-44 44 0.795 22 1.590
ACTT-0250-48 48 0.520 24 1.040 ACTT-0350-48 48 0.729 24 1.458
ACTT-0500-12 12 4.166 6 8.332 ACTT-0650-12 12 5.416 6 10.832
ACTT-0500-14 14 3.571 7 7.142 ACTT-0650-14 14 4.642 7 9.284
ACTT-0500-18 18 2.777 9 5.554 ACTT-0650-18 18 3.611 9 7.222
ACTT-0500-24 24 2.083 12 4.166 ACTT-0650-24 24 2.708 12 5.416
ACTT-0500-30 30 1.666 15 3.332 ACTT-0650-30 30 2.116 15 4.322
ACTT-0500-36 36 1.388 18 2.776 ACTT-0650-36 36 1.085 18 3.61
ACTT-0500-44 44 1.136 22 2.272 ACTT-0650-44 44 1.477 22 2.954
ACTT-0500-48 48 1.041 24 2.082 ACTT-0650-48 48 1.354 24 2.708
ACTT-0850-12 12 7.083 6 14.166
ACTT-0850-14 14 6.071 7 12.142
ACTT-0850-18 18 4.722 9 9.444
ACTT-0850-24 24 3.541 12 7.082
ACTT-0850-30 30 2.833 15 5.666
ACTT-0850-36 36 2.361 18 4.722
ACTT-0850-44 44 1.931 22 3.862
ACTT-0850-48 48 1.770 24 3.540
Part# Series Parallel
V (C.T.) mA ( RMS) V mA (RMS)
Part# Series Parallel
V (C.T.) mA ( RMS) V mA (RMS)
Part# Series Parallel
V (C.T.) mA ( RMS) V mA (RMS)
Part# Series Parallel
V (C.T.) mA ( RMS) V mA (RMS)
Part# Series Parallel
V (C.T.) mA ( RMS) V mA (RMS)
SCHEMATICS:
SEC 2
SEC 1
PRI 2
#6
PRI 1
#3
#4
#5
#11
#12
#13
#14
TOROIDAL TRANSFORMER 50/60HZ, 115/230 VAC, ENCAP
|||||||||||||||
ACTT-0xxx-xx
size varies
Pb
RoHS
Compliant
ABRACON IS
ISO 9001 / QS 9000
CERTIFIED
ABRACON IS
ISO 9001 / QS 9000
CERTIFIED
30332
Esperanza, Rancho Santa Margarita, California
92688
tel 949-546-8000 | fax 949-546-8001 | www.abracon.com
Revised: 02.22.08
Visit www.abracon.com for Terms & Conditions of Sale
OUTLINE DRAWING:
PART NO POWER A B C D E F G H I
ACTT-0016-xx 1.6VA 1.575 1.575 0.728 0.157 0.025SQ 0.138 1.40 0.20 0.10
40.0 40.0 18.5 4.0 0.64SQ 3.5 35.56 5.08 2.54
ACTT-0032-xx 3.2VA 1.772 1.772 0.768 0.157 0.025SQ 0.138 1.60 0.20 0.10
45.0 45.0 19.5 4.0 0.64SQ 3.5 40.64 5.08 2.54
ACTT-0050-xx 5.0VA 1.969 1.969 0.768 0.157 0.025SQ 0.138 1.80 0.20 0.10
50.0 50.0 19.5 4.0 0.64SQ 3.5 45.72 5.08 2.54
ACTT-0070-xx 7.0VA 1.969 1.969 0.909 0.157 0.025SQ 0.138 1.80 0.20 0.10
50.0 50.0 23.1 4.0 0.64SQ 3.5 45.72 5.08 2.54
ACTT-0100-xx 10VA 2.205 2.205 1.024 0.157 0.031SQ 0.138 2.00 0.20 0.10
56.0 56.0 26.0 4.0 0.80SQ 3.5 50.80 5.08 2.54
ACTT-0150-xx 15VA 2.402 2.402 1.035 0.157 0.031SQ 0.138 2.20 0.20 0.10
61.0 61.0 26.3 4.0 0.80SQ 3.5 55.88 5.08 2.54
ACTT-0250-xx 25VA 2.402 2.402 1.476 0.157 0.031SQ 0.138 2.20 0.20 0.10
61.0 61.0 37.5 4.0 0.80SQ 3.5 55.88 5.08 2.54
ACTT-0350-xx 35VA 2.953 2.953 1.476 0.157 0.031SQ 0.236 2.60 0.20 0.10
75.0 75.0 37.5 4.0 0.80SQ 6.0 66.04 5.08 2.54
ACTT-0500-xx 50VA 3.244 3.244 1.476 0.157 0.039SQ 0.236 2.99 0.20 0.10
82.4 82.4 37.5 4.0 1.00SQ 6.0 76.20 5.08 2.54
ACTT-0650-xx 65VA 3.622 3.622 1.535 0.157 0.039SQ 0.276 3.30 0.30 0.10
92.0 92.0 39.0 4.0 1.00SQ 7.0 83.82 7.62 2.54
ACTT-0850-xx 85VA 3.937 3.937 1.654 0.157 0.039SQ 0.276 3.60 0.30 0.10
100.0 100.0 42.0 4.0 1.00SQ 7.0 91.44 7.62 2.54
1) Unused pins are omitted for standard parts. Unused pins can be provided on request.
2) Pin positions #1, 8, 9, 16,17 & 18 are invalid for the 1.6VA series.
3) 1.6VA to 25VA series – blind center hole; 35VA to 85VA series – through center hole.
11
12
17
18
13
14
C D
3
E
12
F
16 15
5
B
4
6
7 8
A
9 10
12
11
14
13
18
17
3
H
H
I
2 1
G
15
H
16
IH
4
5
6
7 8
H H
109
H
H
G
H
H
Inch
mm
(Dimension)=
Mouser Electronics
Authorized Distributor
Click to View Pricing, Inventory, Delivery & Lifecycle Information:
ABRACON:
ACTT-0070-18 ACTT-0250-24 ACTT-0050-14 ACTT-0250-48 ACTT-0050-18 ACTT-0250-44 ACTT-0250-36
ACTT-0250-12 ACTT-0250-18 ACTT-0650-12 ACTT-0150-48 ACTT-0350-36 ACTT-0100-48 ACTT-0350-48 ACTT-
0850-24 ACTT-0032-12 ACTT-0032-30 ACTT-0100-44 ACTT-0100-24 ACTT-0016-48 ACTT-0150-14 ACTT-0032-
14 ACTT-0650-24 ACTT-0850-48 ACTT-0032-18 ACTT-0850-18 ACTT-0032-36 ACTT-0350-18 ACTT-0150-24
ACTT-0032-44 ACTT-0050-12 ACTT-0016-12 ACTT-0250-14 ACTT-0650-14 ACTT-0250-30 ACTT-0100-12 ACTT-
0150-18 ACTT-0350-44 ACTT-0850-12 ACTT-0016-36 ACTT-0100-36 ACTT-0016-44 ACTT-0070-24 ACTT-0350-
30 ACTT-0500-48 ACTT-0500-44 ACTT-0150-12 ACTT-0100-30 ACTT-0650-36 ACTT-0850-14 ACTT-0500-36
ACTT-0016-30 ACTT-0500-24 ACTT-0050-30 ACTT-0500-18 ACTT-0150-36 ACTT-0350-14 ACTT-0650-48 ACTT-
0650-18 ACTT-0850-44 ACTT-0050-24 ACTT-0100-14 ACTT-0150-44 ACTT-0032-24 ACTT-0016-14 ACTT-0070-
30 ACTT-0350-24 ACTT-0070-14 ACTT-0650-44 ACTT-0150-30 ACTT-0350-12 ACTT-0016-18 ACTT-0850-36
ACTT-0016-24 ACTT-0050-44 ACTT-0070-12 ACTT-0850-30 ACTT-0100-18 ACTT-0050-36 ACTT-0650-30 ACTT-
0070-36 ACTT-0500-14 ACTT-0070-44 ACTT-0500-30 ACTT-0050-48 ACTT-0032-48 ACTT-0070-48 ACTT-0500-
12