ORDERING DATA
ELECTRICAL DATA
Typical Output Primary Sense Secondary Primary Sense
Part Number Turns Ratio Current Range (mV / A) Resistance Resistance Inductance Frequency
(µOhms) (Ohms) (H) (Hz)
ACST-255-1 1:50 1-30A 32 530 0.198 0.008 50-200
ACST-256-1 1:100 1-30A 64 530 0.785 0.025 50-200
ACST-257-1 1:150 1-30A 90 530 1.7 0.06 50-200
ACST-258-1 1:200 1-30A 120 530 3.2 0.12 50-200
ACST-259-1 1:300 1-30A 140 530 7.4 0.27 50-200
ACST-260-1 1:500 1-30A 110 530 20 0.72 50-200
ACST-261-1 1:1000 1-30A 60 530 79 2.4 50-200
ACST-260-5 1:1500 1-30A 45 530 220 5.2 50-200
ACST-260-8 1:1500 1-30A 45 530 220 5.2 50-200
ACST-261-8 1:500 1-30A 110 530 20 0.72 50-200
2007-03-12
ZETTLER electronics GmbH
Fax +49 89 800 97 20 0 www.ZETTLERelectron ics.com
office@ZETTLERelectronics.com 0 97 800 89 +49 Tel.
Germany Puchheim , D-82178 Junkersstrasse 3,
2 x .025 Max Sq.
Dimensions in inches with metric equivalents in parentheses. Tolerance: ±0.010"
NOTES:
1. Typical Output test condition is: 10A @ 50Hz / 60Ohm load
2. Secondary Inductance test condition is: 100Hz / 1V
3. Suffix “-8” at the end of part number indicates 8 mm creepage and clearance.