Curtis Industries
A Division of Powers Holdings, Inc.
www.curtisind.com Specications subject to change.
Dimensions are shown for
reference purposes only.
POWER ENTRY MODULES
52
Combination
Nominal
Current
Rating
Part
Number Termination
Line/Load
MINIMUM INSERTION LOSS - dB (50 ohm Circuit)
MODE Frequency - MHz
.15 .50 1.0 5.0 10 30
3A PE7XXX03
PE8XXX03 IEC/Solder
Tabs
Common
Differential 18
8 24
18 30
24 45
46 45
50 50
40
6A PE7XXX06
PE8XXX06 IEC/Solder
Tabs
Common
Differential 10
8 19
18 24
24 39
39 44
40 50
40
PE7/PE8 Series
Specications:
Rated Voltage: 250VAC Maximum - 50/60 Hz
Rated Current: 115VAC 250VAC
3A 3A
6A 6A
Current Overload: 6X for 8 Seconds
Hi-Pot Test (1 min):
Line to Ground 1500VAC
Line to Line 1768VDC
Insulation Resistance: 9 x 109 Ω at 100VDC
Ambient Temperature: 40°C Max. at Rated Current
Humidity Range: 0% to 95% R.H.
Termination:
• IEC Receptacle
• Wire Wrap/Solder
Maximum Leakage Current:
Each Line to Ground PE7, PE 8
115VAC, 60Hz: 0.25mA
250VAC, 50Hz: 0.40mA
Voltage Select Card: Installed in 120VAC position
unless otherwise specied
Agency Approvals:
Features:
RFI Filter Module Combines IEC Connector, Fusing,
and Voltage Select Features in One Unit
PE7 Series Filters Provide 20% More Differential Mode
Attenuation Than Comparable Units
Accepts Either U.S. or European Standard Fuse Sizes
PE7 Series Simplied Schematic
C
A
D
E
2-POLE
H
1-POLE
FUSING
B
Contacts
b,e
b,c
a
Voltage
110V
220V
240V
240V
220V
110V
d
a
b
2a
F
A
110-220-
240 V
VOLTAGE
SELECTOR
G
Fe
c
E
D
C
LOAD
G
G
LINE
L
N
FOR TRANSFORMERS WITH TAP
SERIES-SERIES
Refer to Page 55 for Ordering Instructions
Curtis Industries
A Division of Powers Holdings, Inc. 1-800-657-0853
Dimensions are in inches and millimeters
unless otherwise specied.
Values in parentheses are metric equivalents.
POWER ENTRY MODULES
53
Combination
PE7 Series Simplied Schematic
PE8 Series Simplied Schematic
D
E
C
A
2-POLE
H
1-POLE
FUSING
B
240V b,d
Contacts
a,c,e
b,c,e
a,d
Voltage
100V
120V
220V
120V
100V
120V
d
a
b
F
A
100-120-
220-240 V
VOLTAGE
SELECTOR
G
Fe
c
E
D
C
LOAD
G
G
LINE
L
N
FOR TRANSFORMERS WITH TWO SEPARATE
WINDINGS
SERIES-PARALLEL
D
E
C
A
2-POLE
H
B
B
115V
115V
d
a
b
F
A
G
Fe
c
E
D
C
G
G
L
N
Contacts
a,b d,e
c
Voltage
115V
230V
2-POLE
H
1-POLE
FUSING
1-POLE
2-POLE
L
ROCKER
SWITCH
N
G
LOAD
G
2a
2
1a1
G
LINE
L
N
Curtis Industries
A Division of Powers Holdings, Inc.
www.curtisind.com Specications subject to change.
Dimensions are shown for
reference purposes only.
POWER ENTRY MODULES
54
Combination
PE7/PE8
Snap-Mount Series
(3 and 6Amp) Dimensions
PE7/PE8
Screw-Mount Series
(3 and 6Amp) Dimensions
Refer to Page 55
for Standard
Mounting Cutouts
Refer to Page 55
for Standard
Mounting Cutouts
.100
(2,7) Terminals Except Switch
2.266
(57,55)
1.969
(50,0)
1.142
(29,0)
2.283
(58,0)
.22
(5,5)
1.051
(26,70)
1.091
(27,71)
1.575
(40,0)
.126
(3,20)
Dia. Holes
LINE LOAD
PE7/PE8 Series (continued)
2.283
(58,0)
1.260
(32,0) .22
(5,5)
1.051
(26,70)
1.091
(27,71)
.100
(2,7) Q.C. Terminals All Locations
LINE LOAD
2.266
(57,55)
Curtis Industries
A Division of Powers Holdings, Inc. 1-800-657-0853
Dimensions are in inches and millimeters
unless otherwise specied.
Values in parentheses are metric equivalents.
POWER ENTRY MODULES
55
Combination
INSTALLATION INSTRUCTION
IMPORTANT – CHANGING
FUSE/VOLTAGE
PE7/PE8
To change fuse, remove power cord
and open the front cover on the module.
Remove fuse holder and replace fuse.
Reinsert fuse holder and close cover.
To change the operating voltage on the
PE7 Series, remove the power cord and
open front cover. Rotate voltage select
wheel until desired voltage appears in
window of cover.
Filter shipped without fuse.
Always use caution when selecting
and changing fuses and voltage
requirements. Curtis Industries is not
responsible for malfunction due to
improper installation/selection of fuse
and/or voltage select.
SERIES
PE = Power Entry
VOLTAGE SELECTOR
0 = No Selector (PE80 Series)
1 = 110-220-240 V AC
2 = 100-120-220-240 VAC
3 = 115-230 V AC
OPTIONS
(Consult Factory)
0 = Standard Units
SWITCH
0 = No Switch
1 = SPST Rocker Switch
w/Q.C.
2 = DPST Rocker Switch
w/Q.C.
CURRENT RATING
3 = 3 AMP
6 = 6 AMP
MOUNTING
METHOD & FUSING
0 = Snap Mount Metric Fuse
1 = Snap Mount U.S. Fuse
2 = Snap Mount 2 Metric Fuse
3 = Snap Mount 2 U.S. Fuses
6 = Screw Mount Metric Fuse
7 = Screw Mount U.S. Fuse
8 = Screw Mount 2 Metric Fuses
9 = Screw Mount 2 U.S. Fuses
How to Order
PE7
PE8 X X X X X
PE7/PE8 Screw Mount Series
1.10
(27,9)
2.20
(55,9)
1.575
(40,0)
4-40
(M3)
.08
(2,0) R
1.122
(28,50)
PE7/PE8 Snap-Mount Series
.08
(2,0) R
*Panel Thickness Cutout
.031" - .079" use 2.20"
.080" - .125" use 2.22"
2.20
(55,9)
1.122
(28,50)
*See Below