Alpha
Braid, Bus Bar, Test Lead Wire and Lacing Cord
300
b
ALLIED Letter ÒQÓ In Stock Number Indicates Direct Factory Shipment To You
Tinned Copper Flat Braid
c
Flexible Ground Strips
c
Connect Moving Parts
c
Retrofit Applications
c
Bonding Straps
Woven tinned copper braid rolled to specific width. Meets requirements of Fed. Spec. QQ-W-343E Type
S and ASTM-B-33. *Values shown are for bare cable in free air at 30¡C and intended as a reference
guide only. Actual values will depend on permissible temp. rise, permissible voltage drop and other
conditions of service.
Nom. Braid Construction Approx. Nom.
Stock Mfr.Õs Nom. Flat Current Carrying PER
Thick Total No. of AWG Circular Mil.
No. Type Width (In.) Capacity (Amps*) 100'
(In.) Indiv. Ends Equiv. Area (CM)
708-8068 1229
1
/
8
0.020 72 18 1800 16 30.23
708-8071 1230
3
/
16
0.020 120 15 3000 25 32.91
708-8074 1231
1
/
4
0.030 168 14 4200 32 44.68
708-8077 1232
3/8
0.030 288 12 7200 46 71.52
708-8080 1233/2
1
/
2
0.030 384 10 9600 53 90.62
708-8083 1233
5
/
8
0.030 384 10 9600 53 95.88
708-8086 1234
3
/
4
0.040 864 7 20800 85 215.79
708-8090 1235 1 0.045 864 7 20800 85 230.91
708Q8091 1239 1
3
/
8
0.050 336 5 33700 100 261.79
Meets QQ-B-575B.
Twisted Lacing Cord and Flat Braid Lacing Tape
Nylon and Dacron Flat Braided Lacing Tape. All types are nylon. All types are designation MIL-T-43435
with variations for type, size, and finish. LC-132 has a finish of synthetic rubber-like resin with
non-mercuric fungicidal properties. Melting point is above 190¡F. Softens at 140¡F but doesn't flow.
LC-134 and LC-136 have a finish of micro-Crystalline wax with a melting point above 130¡F, compounded
with a fungicide containing neither copper nor mercury. Soft, pliable and easy to tie. Also meets MIL-T-
713 Type P, Class 2. LC-140 has a finish of a special continuous coating of fungistatic synthetic rubber.
Knots tied with this finish will not slip. Extremely pliable and soft. LC-143 has a thermoplastic synthetic
resin with a melting point above 350¡F for use where a Òwax freeÓ type is specified. Dry, non-flaking
finish. Available in white and black Ñ insert 1 (white) or 2 (black) where X appears in Stock Number.
Stock Mfr.Õs Tensile Nominal Nominal Standard PER
No. Type Strength Width Thickness Put-Up SPOOL
708-942X LC-132 50 0.090" 0.014" 500 yds. on spool 53.63
708-943X LC-134 30 0.062" 0.010" 500 yds. on spool 42.11
708-944X LC-136 50 0.090" 0.012" 500 yds. on spool 48.92
708-945X LC-140 50 0.090" 0.014" 500 yds. on spool 47.88
708-946X LC-143 50 0.090" 0.014" 500 yds. on spool 36.24
Tinned Copper Oval Braid
Stock Mfr.Õs
No. Type
Nom. I.D.
When
Rounded
In. mm
Braid Construction
AWG of
Indiv. Ends
Total No. of
Indiv. Ends
Approx.
AWG
Equiv.
Nom. Circular
Mil Area CM
Approx. Current
Carrying Capacity
(Amps)
PER
100'
696-8000 2132
1
/
16
1.59 34 32 19 1192 11 21.22
696-8001 2138
11
/
64
4.37 34 120 14 4770 32 53.53
696-8002 2140
3
/
16
4.76 34 144 13 5724 38 57.49
696-8003 2142
1
/
4
6.35 34 168 12 6678 41 69.58
696-8004 2144
3
/
8
9.53 34 192 11 7632 46 77.56
696-8005 2146
1
/
2
12.70 34 336 9 13356 62 147.17
696-8006 2148
5
/
8
15.88 34 384 8 14264 64 160.10
696-8007 2150
11
/
16
17.46 34 480 7 19080 81 197.55
696-8008 2152
25
/
32
19.84 34 528 7 20988 85 215.83
Standard Put-Up: 2132, 2138 Ñ 100, 500, 1000 Ft.; 2140-2144 Ñ 100, 500 Ft.; 2146-2152 Ñ 100 Ft.
Stock Mfr.Õs
No. Type
Nom. I.D.
When
Rounded
In. mm
Braid Construction
AWG of
Indiv. Ends
Total No. of
Indiv. Ends
Approx.
AWG
Equiv.
Nom. Circular
Mil Area CM
Approx. Current
Carrying Capacity
(Amps)
PER
100'
696-8010 2160
1
/
32
0.79 36 24 22 600 7.0 16.28
696-8012 2162
1
/
16
1.59 36 48 19 1200 11.0 34.27
696-8014 2163
5
/
64
1.98 36 72 18 1800 16.0 39.76
696-8016 2164
7
/
64
2.78 36 96 16 2400 19.0 52.49
696-8018 2166
1
/
8
3.18 36 120 15 3000 25.0 54.73
696-8020 2167
5
/
32
3.97 36 240 12 6000 40.0 90.62
696-8022 2168
11
/
64
4.37 36 168 14 4200 32.0 69.75
696-8024 2170
13
/
64
5.16 34 192 11 7630 46.0 97.06
696-8026 2171
1
/
4
6.35 36 384 10 9600 53.0 131.25
696-8028 2171/1
9
/
32
7.14 30 120 9 12060 60.0 136.90
696-8030 2172
3
/
8
9.53 36 384 10 9600 53.0 135.27
696-8032 2173
7
/
16
11.11 30 240 6 24120 90.0 223.18
696-8034 2174
1
/
2
12.70 36 528 9 13200 62.0 185.46
696Q8036 2175
9
/
16
14.29 30 480 3 48240 145.0 342.35
696Q8038 2175/1
21
/
32
16.67 30 768 1 77180 190.0 524.81
696Q8040 2176
25
/
32
19.84 36 864 7 21600 88.0 251.00
696Q8042 2178 1 25.4 30 384 4 38600 120.0 444.09
Standard Put-Up: 2160-2168 Ñ 100 Ft., 250 Ft.; 2170-2176 Ñ 100 Ft. only.
Tinned Copper Tubular Braid
c
Each Strand Soft Drawn Tinned Copper Wire Meets Fed. Spec QQ-W-343E and ASTM-B-33
c
Shield Coverage Is 95% When Placed Over Mandrel of Equivalent Diameter to That of Braid Interior
Tinned Copper Bus Bar
c
MIL-W-3861* Type S
c
QQ-W-343 Type S
c
ASTM-B-33
Electrolytic, soft drawn and annealed, solid tin-plated copper. MIL-W-3861 Type S, QQ-W-343 Type S, ASTM-B-33. *No longer a current
military specification.
Mfr.Õs Cond. Nom. Circular
Type AWG Mil. Area, CM
Nom. O.D. 100' 1000'
In. mm Stock
No. EACH Stock
No. EACH
286 14 4110 0.065 1.62 708-8052 35.71 708Q8053 264.05
295 16 2580 0.051 1.30 708-8054 23.54 708-8055 179.54
296 18 1620 0.040 1.02 708-8056 16.61 708-8057 116.45
297 20 1020 0.032 0.81 708-8058 12.81 708-8059 81.99
298 22 640 0.025 0.63 708-8060 10.34 708-8061 61.72
299 24 404 0.020 0.51 708-8062 10.06 708-8063 47.51
299/1 26 253 0.016 0.41 708-8064 9.81 708-8065 45.18
299/2 28 159 0.013 0.33 708-8066 9.69 708-8067 39.33
Mfr.Õs
Type
Nom.
Ins.
Thick
.
Voltage
Breakdown
Sugg.
Working
Voltage
Nominal
O.D.
100' 500' 1000'
Stock
No. EACH
Conductor
AWG Strand Stock
No. EACH Stock
No. EACH
1632 20 41/36 0.040 6000 1500 V 0.125" (3.18 mm) 696-790N 32.99 696-791N 135.95 696Q792N 239.48
1635 20 41/36 0.047 12000 3000 V 0.140" (3.56 mm) 696-787N 35.35 696-788N 147.49 696Q789N 260.25
1636 18 65/36 0.045 20000 5000 V 0.140" (3.56 mm) 696-796N 39.49 696-797N 145.23 696Q798N 264.05
1638 18 65/36 0.090 29000 10000 V 0.230" (5.84 mm) 696-784N 54.28 696Q785N 223.73 696Q786N 491.50
Test Lead Wire
c
Conductor: Stranded Tinned Copper
c
Insulation: Color Coded Rubber
c
Temperature Range: Ð30¡C to +90¡C
c
Colors Available: 2 Ñ Black; 3 Ñ Red; Insert 2 or 3 Where
N Appears in Stock Number
Copper Shielding Tape
c
UL Standard 510
c
MIL-Standard 202C
c
ASTM-D-1000
c
UL Recognized
c
Highly Conductive Pressure Sensitive Adhesive
c
Oxidation Resistant Conductive Particles in Adhesive Produce
Very Low Resistance Through Tape
Provides a low impedance connection between metal connector
backshell and the braided cable shield in molded cables. An effective
EMI/RFI shielded cable assembly can be achieved without soldering the
tape to the braid or backshell (a tin-plated backshell is recommended).
Provides electrical contact to surfaces that cannot be soldered such as
conductive plastic. EMI/RMF shielding of cables by wrapping the tape
around the cable. (Recommend 40-50% overlap). Provides electrical
continuity in seams of EMI/RFI shielded rooms. Draining of static
charges. Bus bar application. Specifications. Tensile Strength:
21 lbs./in. Adhesion: 40 oz./in. Thickness: .003 in. Flammability:
Flame retardant per UL Standard 510. Electrical Resistance Through
Tape: .003 ohms/in.
2
Shielding Effectiveness: 50 dB.
708-8092 CST-5
1
/
2
12.7 36 yards 78.17
708-8093 CST-10 1 25.4 36 yards 163.16
708-8094 CST-15 1
1
/
2
38.1 36 yards 102.22
708Q8095 CST-20 2 50.8 36 yards 317.63
Stock Mfr.Õs
No. Type
Width
In. mm Length EACH
c
Woven Tinned Copper Braid Manufactured in Tubular Configuration Provides 90% Coverage
c
Each Strand Meets Requirements of Fed. Spec. QQ-W-343E and ASTM-B-33
c
Appl. Shielding, Cable/Harness Assembly
7