©2018 Peregrine Semiconductor Corp. All rights reserved. Document No. DOC-87416-1 | www.psemi.com
PE42441
Page 3 of 12
Product Specification
Figure 3. Pin Configuration (Top View)
Pin # Pin
Name Description
1, 3-6, 8,
9-12, 14-17,
19-22, 24-26,
28, 31, 32
GND Ground
2 RF41 RF port
7 RF21 RF port
13 RFC1 RF common
18 RF11 RF port
23 RF31 RF port
27 VDD Supply voltage
29 V1 Digital control logic input 1
30 V2 Digital control logic input 2
Pad GND Exposed pad: Ground for proper operation
Table 2. Pin Descriptions
Note 1: RF pins 2, 7, 13, 18, and 23 must be at 0V DC. The RF pins do not
require DC blocking capacitors for proper operation if the 0V DC
requirement is met
Table 3. Operating Ranges
Parameter Symbol Min Typ Max Unit
Supply voltage VDD 3.0 3.3 3.55 V
Supply current IDD 90 160 µA
Digital input high (V1, V2) VIH 1.2 1.5 VDD V
Digital input low (V1, V2) VIL 0 0 0.4 V
Digital input current ICTRL 1 µA
RF input power, CW1
10 MHz – 8 GHz PMAX,CW See
Fig. 4
dBm
RF input power into
terminated ports, CW
10 MHz – 8 GHz PMAX,TERM
+20
dBm
Operating temperature
range TOP –40 +85 °C
Notes: 1. 100% duty cycle (–40 to +85°C, 1:1 VSWR)
8
7
6
5
4
3
2
1 24
23
22
21
20
19
18
17
32 31 30 29 28 27 26 25
161514131211109
Exposed
Ground Pad
GND
RF2
RF4
GND
GND
GND
GND
GND
GND
RF1
RF3
GND
GND
GND
GND
GND
GND
GND
GND
GND
GND
RFC
GND
GND
GND
GND
GND
V2
V1
GND
VDD
GND
Pin 1 Dot
Marking
Table 4. Absolute Maximum Ratings
Parameter/Condition Symbol Min Max Unit
Supply voltage VDD –0.3 4.0 V
Digital input voltage (V1, V2) VCTRL –0.3 4.0 V
Maximum input power
10 MHz – 8 GHz PMAX,ABS See
Fig. 4
dBm
Storage temperature range TST –60 +150 °C
ESD voltage HBM1, all pins VESD,HBM 2 kV
ESD voltage MM2, all pins VESD,MM 100 V
ESD voltage CDM3, all pins VESD,MM 1 kV
Notes: 1. Human Body Model (MIL-STD 883 Method 3015.7)
2. Machine Model (JEDEC JESD22-A115-A)
3. Charged Device Model (JEDEC JESD22-C101)
Exceeding absolute maximum ratings may cause
permanent damage. Operation should be
restricted to the limits in the Operating Ranges
table. Operation between operating range
maximum and absolute maximum for extended
periods may reduce reliability.