Low Signal Relay G5V-2 * Suitable for handling low signals in computer peripherals, telecommunications and security equipment. * Capable of switching loads up to 2 A. * Conforms to FCC part 68 1500 V surge withstand. * Reliable bifurcated crossbar contacts. * Fully-sealed construction. Ordering Information To Order: Select the part number and add the desired coil voltage rating (e.g., G5V-2-DC12). Type Standard Contact form DPDT Construction Model Fully-sealed G5V-2 High-sensitivity G5V-2-H Ultra-sensitive G5V-2-H1 Specifications Contact Data Item Standard and high-sensitivity Ultra-sensitive Load Resistive load (p.f. = 1) Rated load 0.50 A at 125 VAC 2 A at 30 VDC Contact material Ag (Au clad) Carry current 2A Max. operating voltage 125 VAC 125 VDC Max. operating current 2A 1A Max. switching capacity 62.5 VA 60W 62.5 VA 24W Min. permissible load 10 A, 10 mVDC 1 Low Signal Relay G5V-2 0.5 A at 125 VAC 1 A at 24 VDC Coil Data Standard Type Rated voltage Rated current Coil Coil inductance (VDC) (mA) resistance (Ref. value) (H) () Armature OFF Armature ON 3 166.70 18 0.04 0.05 5 100 50 0.09 0.11 6 83.30 72 0.16 0.19 9 55.60 162 0.31 0.49 12 41.70 288 0.47 0.74 24 20.80 1,152 1.98 2.68 48 12 4,000 -- -- Pick-up voltage Dropout voltage Maximum voltage % of rated voltage 75% max. 5% min. Power consumption (mW) 120% max. at 65C (149F) Approx. 500 110% max. at 60C (140F) Approx. 580 High-sensitivity Type Rated voltage Rated current Coil (VDC) (mA) resistance () Coil inductance (Ref. value) (H) Armature OFF Pick-up voltage Armature ON 3 120 25 0.04 0.07 5 72 70 0.12 0.19 6 60 100 0.18 0.29 9 40 225 0.40 0.62 12 30 400 0.75 1.18 24 15 1,600 3.16 4.81 48 7.5 6,400 -- -- Dropout voltage Maximum voltage Power consumption (mW) % of rated voltage 75% max. 5% min. 120% max. at 70C (158F) Approx. 360 110% max. at 70C (158F) Ultra-sensitive Type Rated voltage Rated current Coil (VDC) (mA) resistance () Coil inductance (Ref. value) (H) Armature OFF Pick-up voltage Armature ON Dropout voltage Maximum voltage Power consumption (mW) % of rated voltage 3 50 60 0.18 0.26 5 30 166.7 0.46 0.47 75% max. 5% min. 150% max. at 70C (158F) Approx. 150 6 25 240 0.70 0.97 9 16.70 540 1.67 2.33 12 12.50 960 2.90 3.99 24 8.30 2,880 6.72 9.27 Approx. 120 48 6.25 7,680 20.10 26.70 Approx. 300 Note: 1. The rated current and coil resistance are measured at a coil temperature of 23C (73F) with a tolerance of 10%. 2. The operating characteristics are measured at a coil temperature of 23C (73F). Low Signal Relay G5V-2 2 Characteristics Contact resistance 50 m max. G5V-2, G5V-2-H, 100 m max. G5V-2-H1 Operate time 7 ms max. (mean value: approx. 3.5 ms) Release time Bounce time Operating frequency 3 ms max. (mean value: approx. 0.8 ms) Operate Mean value: approx. 0.5 ms Release Mean value: approx. 3.5 ms Mechanical 36,000 operations/hour Electrical 1,800 operations/hour (under rated load) Insulation resistance 1,000 M min (at 500 VDC) Dielectric strength 1,000 VAC, 50/60 Hz for 1 minute between coil and contacts 1,000 VAC, 50/60 Hz for 1 minute between contacts of different poles 750 VAC, 50/60 Hz for 1 minute between contacts of same poles (500 VAC, 50/60 Hz for 1 minute between contacts of same poles for ultra-sensitive type) Surge withstand voltage Vibration 1,500 V 10 X 160 s (conforms to part 68 of FCC rules) Mechanical durability 10 to 55 Hz, 1.50 mm (0.59 in) double amplitude Malfunction durability Shock Mechanical durability 1,000 m/s2 (approx. 100 G) Malfunction durability 200 m/s2 (approx. 20 G), 100 m/s2 (approx. 10 G) for ultra-sensitive type Ambient temperature Operating/storage -25 to 70C (-13 to 158F) Humidity 35% to 85% RH Service life Mechanical 15 million operations min. (at operating frequency of 36,000 operations/hour) Electrical See "Characteristic Data" Weight 6 g (0.21 oz) Note: Data shown are of initial value. Electrical Service Life Service life (X103 operations) Rated operating voltage (V) 3 Low Signal Relay G5V-2 Ambient Temperature vs. Maximum Voltage Maximum voltage (%) Maximum Switching Capacity Rated operating current (A) Characteristic Data Rated operating current (A) Rated operating current (A) --- 48 VDC coil voltage (standard type) All other types and voltages Dimensions Unit: mm (inch) Relays Fully-sealed Terminal arrangement/Internal (bottom view) Mounting holes (bottom view) Note: 1. and indicate mounting orientation marks. 2. A tolerance of 0.10 (0.004) applies to the above dimensions. Approvals UL (File No. E41515)/CSA (File No. LR24825) Type G5V-2 G5V-2-H Contact form DPDT G5V-2-H1 Coil rating Contact ratings 3 to 48 VDC 3 to 24 VDC 0.6 A, 125 VAC 0.6 A, 110 VDC 2.0 A, 30 VDC 3 to 48 VDC 0.5 A, 125 VAC 0.6 A, 125 VAC 0.2 A, 110 VDC 0.6 A, 110 VDC 1.0 A, 24 VDC Note: 1. The rated values approved by each of the safety standards may be different from the performance characteristics individually defined in this catalog. 2. In the interest of product improvement, specifications are subject to change. 3. UL1950 recognition. ALL DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters into inches, divide by 25.4 OMRON ELECTRONICS LLC OMRON CANADA, INC. OMRON ON-LINE One Commerce Drive Schaumburg, IL 60173 885 Milner Avenue Toronto, Ontario M1B 5V8 847-882-2288 416-286-6465 Global - http://www.omron.com USA - http://www.omron.com/oei Canada - http://www.omron.ca Cat. No. GC RLY8 5/03 Specifications subject to change without notice Printed in USA Low Signal Relay G5V-2 4