C
ompa
c
t
for
H
igh
D
en
s
ity
P
CB
M
ount
D
C
C
ontrol
S
CR
O
utput
FastFax Document No.102
SERIES SDV, SDI.
Rev. 042302
PAGE 1 OF 1
S
erie
s
S
DV,
S
DI
1.5 Amp • 120/240Vac • 16 PIN DIP Package
The Series SDV and SDI solid state relays
are rated at 1.5 Amps RMS at ambient
temperatures up to 40ûC. The compact
16 pin DIP package is perfect for high
density printed circuit boards. The SDV
is voltage operated, and the SDI is cur-
rent operated. Both are offered in
either zero voltage or random switch-
ing (R) versions.
Manufactured in Crydom's ISO 9002
Certified facility for optimum product
performance and reliability.
MODEL NO.
S
DV2415
S
DV2415
R
S
DI2415
S
DI2415
R
IN
P
U
T
SPE
C
I
F
I
C
A
T
ION
S
Control Voltage Range 3.5-10 Vdc 3.5-10 Vdc ------
Control Current Range ------ 10-35 mA 10-35 mA
Nominal Input Impedance 270 Ohm 270 Ohm ------
Typical Input Current @ 5 Vdc 15 mAdc 15 mAdc ------
Must Turn On Voltage 3.5 Vdc 3.5 Vdc ------
Must Turn On Current ------ 10 mA 10 mA
Must Turn Off Voltage 1.0 Vdc 1.0 Vdc ------
Must Turn Off Current ------ 1 mA 1 mA
OU
T
P
U
T
SPE
C
I
F
I
C
A
T
ION
S
Operating Voltage Range (47-63 Hz) 12-280 Vrms
Load Current Range .025 - 1.5 Arms
Transient Over-Voltage 600 Vpk
Max. Surge Current, (16.6ms) 30 Apk
Min. Off-State dv/dt @ Max. Rated Voltage
500 V/µsec
Max.Off-State Leakage @ Rated Voltage .01 mArms
Max. On-State Voltage Drop @ Rated Current
1.2 Vpk
Max.Turn-On Time 1/2 cycle 0.1 msec 1/2 cycle 0.1 msec
Max. Turn-Off TIme 1/2 cycle
Power Factor (Min.) WIth Max. Load 0.5
G
E
N
E
R
A
L
SPE
C
I
F
I
C
A
T
ION
S
Dielectric Strength 3750 Vrms
Insulation Resistance (Min.) @ 500 Vdc 109Ohm
Max. Capacitance, Input-Output 2.0 pF
Ambient Operating Temperature Range -30 to 80˚C
Ambient Storage Temperature Range -30 to 125˚C
M
E
C
HANI
C
A
L
SPE
C
I
F
I
C
A
T
ION
S
Weight: (typical) .10 oz. (2.9 g)
Encapsulation: Thermally Conductive Epoxy
C
U
RR
E
N
T
D
E
R
A
T
IN
G
C
U
R
V
E
.850
(21.6)
.19
(4.8)
.125
(3.2)
.025
(.6)
16
1
10
8
.70
(17.8) .300
(7.6)
.60
(15.2)
.265
(6.7)
16
1
10
8
AC
AC
--
+
INPUT OUTPUT
1.5
0.5
1.0
20 40 60 80
AMBIENT TEMPERATURE (˚C)
LOAD CURRENT (AMPS)
Max. Load Current vs. Temp.
PIN 8: AC LOAD
PIN 10:AC LOAD
PIN 16:+DC CONTROL
PIN 1: -DC CONTROL
G
E
N
E
R
A
L
NO
T
ES
All parameters at 25¼C unless otherwise specified.
Dielectric and insulation resistance are measured
between input and output.
Off-State dv/dt test method per EIA/NARM standard RS-443.
©2002 CRYDOM CORP, Specifications subject to change without notice.
All dimensions are in inches (millimeters)
A
PP
R
OVA
L
S
UL 116950
CSA LR81689
For recommended applications and more information contact:
USA: Sales Support (877) 502-5500 Tech Support (877) 702-7700 FAX (619) 710-8540
Crydom Corp, 2320 Paseo de las Americas, Ste. 201, San Diego, CA 92154
Email: sales@crydom.com
WEB SITE: http://www.crydom.com
UK: +44 (0)1202 365070 • FAX +44 (0)1202 365090 Crydom International Ltd., 7 Cobham
Road, Ferndown Industrial Estate, Ferndown, Dorset BH21 7PE, Email: intsales@crydom.com.
GERMANY: +49 (0)180 3000 506