19 In te re rfac lay e s R910 Relay modules DIN 1-3 M 4/9.R111... - 2.5 mm blocks - 9 mm .354" spacing Characteristics Relay characteristics M 4/9.R111 COIL Rated voltage +20%, -20% on DC Power Rated current Drop-out voltage 24 V 0.3 W 14 mA 2.4 V DC A2 center of rail 12 V 0.6 W 52 mA 1.2 V 24 V 0.8 W 33 mA 2.4 V lamp Status device CONTACT Type Voltage switching range min./max. Current switching range Load switching range AC1 min. / max. DC1 min. / max. Number of on-load operations Number of off-load operations Pull-in time (delay time) Drop-out time (delay time) Bounce time Insulation coil / contacts Breakdown voltage with 1.2/50 wave Insulation contacts/contacts Storage ambient temperature Operating ambient temperature A1 11 12 V 0.3 W 24 mA 1.2 V DC M 4/9.R111L 1 NO 12 V / 150 V DC - 250 V AC 10 mA / 5 A 0.6 VA / 1250 VA 0.6 W / 150 W 1 x 106 2 x 107 5 ms 6 ms 7 ms 4 ms 3000 V RMS 4000 V RMS 750 V RMS -40C to +80C See derating curve hereunder Other characteristics M 4/9.R111... Body material grey Wire Solid wire size Stranded wire UL 94 V0 0.2-4 mm / 22-12 AWG 0.22-2.5 mm / 22-12 AWG 2.5 mm / 12 AWG 9 mm .354" 3.5 mm .137" IP 20 NEMA 1 0.4-0.6 Nm 3.5-5.3 lb.in Derating curve M 4/9.R111 M 4/9.R111... Order codes M 4/9.R111L 6 Order P/N Packaging Weight kg Description Type Relay module 12 V DC Relay module 24 V DC M 4/9.R111 M 4/9.R111 12 V DC 24 V DC 1SNA 607 029 R0100 1SNA 607 030 R0600 10 10 0.02 0.02 Relay module with lamp 12 V DC Relay module with lamp 24 V DC M 4/9.R111L M 4/9.R111L 12 V DC 24 V DC 1SNA 607 001 R0600 1SNA 607 002 R0700 10 10 0.02 0.02 5 4 Accessories 2 1 High end stop (all rails) 3 9 1SNA 114 836 R0000 50 2 Test socket DIA. 3 mm DIA. 2 mm AL2 1 AL3 1 1SNA 163 070 R0000 1SNA 163 261 R0000 50 50 3 Test device grey DCG 1SNA 163 218 R0500 10 FC2 1SNA 007 865 R2600 10 BJS9 12 BJS9 12 1SNA 177 583 R1200 1SNA 177 584 R1300 6 Sub-assembly for jumper bar (screw + jumper + post) EV6D 12 1SNA 168 400 R1600 20 7 IDC jumper AD2,5 1SNA 114 205 R2000 50 8 Comb type jumper bar PC9 1SNA 210 160 R1200 10 9 Marking method 11 BAMH 4 Test plug 7 1 8 5 Jumper bar not assembled 8 poles 16 poles 9,1 mm RC65 and RC610 19 see markers 1 These accessories can be used on the lower connection only. 2 Use of these accessories requires the user to cut out the precut partition. Low Voltage Products & Systems ABB Inc. * 888-385-1221 * www.abb-control.com 19.9 1SXU 000 020 C0201 19 R910 Relay modules DIN 1-3 ce fa r s te In elay r M 4/9.R111... - 2.5 mm blocks - 9 mm .354" spacing Characteristics M 4/9.R111 Relay characteristics COIL Rated voltage +20%, -20% on DC Power Rated current Drop-out voltage at 20C Status device 14 A2 center of rail M 4/9.R111... 24 V 0.3 W 14 mA 2.4 V DC 12 V 0.6 W 52 mA 1.2 V 24 V 0.8 W 33 mA 2.4 V lamp CONTACT Type Voltage switching range min./max. Current switching range Load switching range AC1 min. / max. DC1 min. / max. Number of on-load operations Number of off-load operations Pull-in time (delay time) Drop-out time (delay time) Bounce time Insulation coil / contacts Breakdown voltage with 1.2/50 wave Insulation contacts/contacts Storage ambient temperature Operating ambient temperature A1 11 12 V 0.3 W 24 mA 1.2 V DC M 4/9.R111L 1 NO 12 V / 150 V DC - 250 V AC 10 mA / 5 A 0.6 VA / 1250 VA 0.6 W / 150 W 1 x 106 2 x 107 5 ms 6 ms 7 ms 4 ms 3000 V RMS 4000 V RMS 750 V RMS -40C to +80C See derating curve hereunder Other characteristics UL 94 V0 0.2-4 mm / 22-12 AWG 0.22-2.5 mm / 22-12 AWG 2.5 mm / 12 AWG 9 mm .354" 3.5 mm .137" IP 20 NEMA 1 0.4-0.6 Nm 3.5-5.3 lb.in Body material grey Wire Solid wire size Stranded wire Rated wire size Wire stripping length Recommended screwdriver Protection Recommended torque Approvals CEI 947-7-1 / CEI 947-1 / CEI 1131-2 (in relevant parts) / CEI 60664-1 / CEM : IRC 1000-4-2, 3, 4, 5, 6. Reference standards M 4/9.R111 Derating curve M 4/9.R111L M 4/9.R111... Order Codes Description Type 6 19 Weight Relay module 12 V DC Relay module 24 V DC M 4/9.R111-12VDC M 4/9.R111-24VDC 1SNA 607 029 R0100 1SNA 607 030 R0600 10 10 0.02 0.02 Relay module with lamp 12 V DC Relay module with lamp 24 V DC M 4/9.R111L-12VDC M 4/9.R111L-24VDC 1SNA 607 001 R0600 1SNA 607 002 R0700 10 10 0.02 0.02 1 High end stop (all rails) 2 3 9 8 BAMH 2 Test socket DIA. 3 mm DIA. 2 mm 3 Test device grey 1SNA 114 836 R0000 50 AL2 1 AL3 1 9,1 mm 1SNA 163 070 R0000 1SNA 163 261 R0000 50 50 DCG 1SNA 163 218 R0500 10 FC2 1SNA 007 865 R2600 10 BJS9 12 BJS9 12 1SNA 177 583 R1200 1SNA 177 584 R1300 6 Sub-assembly for jumper bar (screw + jumper + post) EV6D 12 1SNA 168 400 R1600 4 Test plug 7 1 Packaging kg Accessories 5 4 Order P/N 5 Jumper bar not assembled 8 poles 16 poles 20 7 IDC jumper AD2,5 1SNA 114 205 R2000 50 8 Comb type jumper bar PC9 1SNA 210 160 R1200 10 9 Marking method RC65 and RC610 see marking 1 These accessories can be used on the lower connection only. 2 Use of these accessories requires the user to cut out the precut partition. 19.10 1SXU 000 020 C0201 Low Voltage Products & Systems ABB Inc. * 888-385-1221 * www.abb-control.com