DATA SHEET
Ametherm, Inc. 3111 N. Deer Run Road #4 Carson City, NV 89701
Telephone: (800) 808-2434 (775) 884-2434 Fax: (775) 884-0670
www.ametherm.com
Part Number: SL08 4R003
Ordering Different Lead Types:
For example: to order an inside kinked lead use part number SL08 4R003-A
Electrical Specifications: Mechanical Specifications:
CSA File #: CA 118061 Revision Date: March 19, 2003
Inside Kinked Leads Use -A after Ametherm’s part #
Outside Kinked Leads Not Available
Resistance @ 25°C 4.0 ± 20%
Max Steady State Current Up to 65°C 3.0 A
Max Recommended Energy Rating (Joul es) 10.0 J
Actual Failure Point of Instantaneous Energy (Joules) 20.0 J
Resistance @ 100% of Max Current 0.234
Resistance @ 50% of Max Current 0.320
Body Temperature @ 100% Current Rating 122 °C
Dissipation Constant 9.0mW/°C
The rmal Time Co nst ant 20 second s
Max Operating Temperatur e 160 °C
Temperature Coefficient -3.0%/°C
D 8.0 ± 0.5 mm
T 4.0 ± 0.5 mm
Lead Diameter 0.5 ± 0.1 mm
S 6.4 ± 2.0 mm
L 38.0 ± 3.0 mm
Straight Leads
Coati ng Run Down 5.0 ± 1.0 mm
B 5.00 ± 1.00 mm
C 1.50 ± 0.2 mm
L
OUTSIDE
KINKED LEADS
S
STRAIGHT
LEADS
B
INSIDE
KINKED LEADS
S S
D D D
C
T