Solid State Relay G3MB Low cost Subminiature PCB mounting 2 amp Single in-line package (SIP) SSR * Bottom is approximately 3 times smaller than G3M. * Low cost "SIP" package switches up to 2A loads. * Built in Snubber circuit and input resistor as option. * Two footprints available for design flexibility. * The G3MB-202PEG-4-DC20MA crosses directly to the Motorola M0C2A-60 series power triac. Ordering Information To Order: Specify input voltage at end of part number. Example: G3MB-202P-DC24 Isolation Phototriac Output terminal pitch 7.62 mm Zero cross Yes Input resistor Yes Built-in snubber circuit Yes Rated output load 2 A at 100 to 240 VAC Rated input voltage 5 VDC Model G3MB-202P 12 VDC 24 VDC No 2 A at 100 to 240 VAC 5 VDC G3MB-202PL 12 VDC 24 VDC 5.08 mm Yes 2 A at 100 to 240 VAC 5 VDC G3MB-202P-4 12 VDC 24 VDC No 2 A at 100 to 240 VAC 5 VDC G3MB-202PL-4 12 VDC 24 VDC Yes No No No 2 A at 100 to 240 VAC N/A *(See Note) G3MB-202PEG-4-DC20MA 2 A at 100 to 240 VAC N/A *(See Note) G3MB-202PLEG-4-DC20MA Note: 1. For versions without input voltage specified, a current limiting resistor must be placed in series with the input. See LED drive specifications and recommendations below. 2. TUV versions available. Contact your local Omron representative. 1 Solid State Relay G3MB Specifications Input Rating Models with Input Resistor Rated voltage 5 VDC Operating range 4 to 6 VDC Input impedance 440 20% 12 VDC 9.60 to 14.40 VDC 1k 20% 24 VDC 19.20 to 28.80 VDC 2.20k 20% Output Rating Model G3MB-202 Rated load voltage 100 to 240 VAC Load voltage range 75 to 264 VAC Load current Surge current 0.10 to 2 A 30 A (60 Hz, 1 cycle) LED Drive Data Models without Input Resistor LED forward current 50 mA max. Repetitive peak LED forward current 1 A max. LED reverse voltage 5 V max. Recommended LED Operating Conditions Models without Input Resistor Min. Standard Max. LED forward current 5 mA 10 mA 20 mA Must drop voltage 0 -- 1V Characteristics Type G3MB-202P G3MB-202PEG G3MB-202PL G3MB-202PLEG Operate time 1/2 of load power source cycle + 1 ms max. Release time 1/2 of load power source cycle + 1 ms max. Output ON voltage drop 1.60 V (RMS) max. Leakage current 1 mA max. at 100 VAC, 1.50 mA at 200 VAC Non-repetitive peak surge Output 1 ms max. 30 A PIV (VDRM) 600 V di/dt 40 A/s dv/dt 100 V/s I2 t 4 A2s Junction temperature (Tj) 125C (257F) max. Insulation resistance 1,000 M min. at 500 VDC Dielectric strength 2500 VAC, 50/60 Hz for 1 minute; 3750 VAC max., 1 second Vibration Malfunction 10 to 55 Hz, 0.75 mm (0.03 in) double amplitude, approx. 5 G Shock Malfunction Approx. 100 G Ambient temperature Operating -30 to 80C (-22 to 176F) with no icing Storage -30 to 100C (-22 to 212F) with no icing Operating 45% to 85% RH Humidity Weight Approx. 5 g (0.18 oz) Note: Data shown are of initial value. Solid State Relay G3MB 2 Characteristic Data Load current vs. ambient temperature characteristics Inrush current resistivity Non-repetitive (Keep the inrush current to half the rated value if it occurs repetitively.) 40 2.0 Inrush current (A Peak) Switching current (A) 2.5 1.5 1.0 0.5 30 20 10 0 -40 -20 0 20 25 40 60 80 0 100 10 Ambient temperature C 30 50 100 300 500 1,000 5,000 10,000 Switching current (A) 100 Dimensions Unit: mm (inch) Relays PCB Dimensions (Bottom view) G3MB Four 1.0 (0.04) dia. 20.5 (0.81) max. 2.54 (0.1) 2.54 (0.1) 3.9 (0.15) 7.62 (0.30) 2.54 (0.10) 24.5 (0.96) max. 1.4 (0.06) 0.7 (0.03) 0.4 (0.02) G3MB (-4) Four 1.0 (0.04) dia. 5.5 (0.22) max 2.54 (0.1) 2.54 (0.1) Terminal Arrangement/ Internal Connections (Bottom view) 4 (-) 3 (+) INPUT 3 Solid State Relay G3MB 2 1 LOAD Approvals UL (File No. E64562) SSR Type G3MB-102P Input voltage 5 to 24 VDC Load type General purpose Load ratings 2 A, 120 VAC Tungsten 1 A, 120 VAC Motor 1.60 FLA/9.60 LRA, 120 VAC G3MB-202P General purpose 2 A, 240 VAC G3MB-202PL Tungsten 1 A, 240 VAC G3MB-202PEG Motor 1.60 FLA/9.60 LRA, 240 VAC G3MB-202PLEG CSA (File No. LR35535) SSR Type G3MB-102P Input voltage 5 to 24 VDC Load type General purpose Load ratings 2 A, 120 VAC Tungsten 1 A, 120 VAC Motor 1.60 FLA/8.60 LRA, 120 VAC G3MB-202P General purpose 2 A, 240 VAC G3MB-202PL Tungsten 1 A, 240 VAC Motor 1.60 FLA/8.60 LRA, 240 VAC Note: 1. The rated values approved by each of the safety standards (e.g., UL and CSA) may be different from the performance characteristics individually defined in this catalog. 2. In the interest of product improvement, specifications are subject to change. Precautions See General Information Section near the back of this catalog for Solid State Precautions. Protective Component Soldering must be completed within 10 seconds at 260C or less. The input circuitry does not incorporate a circuit protecting the SSR from being damaged due to a reversed connection. Make sure that the polarity is correct when connecting the input lines. Make sure that the space between the bottom of the relay and the PCB is 0.1 mm or less. When making holes on the PCB for the relay's edge terminals, the hole diameters should be slightly smaller than the actual diameters of the edge terminals. This will reduce unnecessary space between the bottom of the relay and the PCB. To use the SSR output for phase control, select a model that does not incorporate a zero-cross function. The SSR case serves to dissipate heat. When mounting more than three SSRs as a group, pay attention to the ambient temperature rise and install the Relays so that they are adequately ventilated. If poor ventilation is unavoidable, reduce the load current by half. ALL DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters into inches, divide by 25.4 Solid State Relay G3MB 4 ALL DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters into inches, divide by 25.4 OMRON ELECTRONICS LLC OMRON CANADA, INC. OMRON ON-LINE One Commerce Drive Schaumburg, IL 60173 885 Milner Avenue Toronto, Ontario M1B 5V8 847-882-2288 416-286-6465 Global - http://www.omron.com USA - http://www.omron.com/oei Canada - http://www.omron.ca Cat. No. GC RLY8 5 5/03 Specifications subject to change without notice Solid State Relay G3MB Printed in USA