TGL34-6.8 ... TGL34-200CA
Maximum ratings Grenzwerte
Type
Typ
Breakdown voltage at IT = 1 mA
Abbruch-Spannung bei IT = 1 mA
*) at / bei IT = 10 mA
Stand-off voltage
Sperrspannung
Max. rev. current
Max. Sperrstrom
at / bei VWM
Max. clamping voltage
Max. Begrenzer-Spannung
at / bei IPPM (10/1000 µs)
VBR [V] VWM [V] ID [µA] VC [V] IPPM [A]
TGL34-43 43 ± 10% 38.7...47.3 34.8 5 61.9 2.4
TGL34-43A 43 ± 5% 40.9...45.2 36.8 5 59.3 2.5
TGL34-47 47 ± 10% 42.3...51.7 38.1 5 67.8 2.2
TGL34-47A 47 ± 5% 44.7...49.4 40.2 5 64.8 2.3
TGL34-51 51 ± 10% 45.9...56.1 41.3 5 73.5 2.0
TGL34-51A 51 ± 5% 48.5...53.6 43.6 5 70.1 2.1
TGL34-56 56 ± 10% 50.4...61.6 45.4 5 81 1.9
TGL34-56A 56 ± 5% 53.2...58.8 47.8 5 77 1.9
TGL34-62 62 ± 10% 55.8...68.8 50.2 5 89 1.7
TGL34-62A 62 ± 5% 58.9...65.1 53.0 5 85 1.8
TGL34-68 68 ± 10% 61.2...74.8 55.1 5 98 1.5
TGL34-68A 68 ± 5% 64.6...71.4 58.1 5 92 1.6
TGL34-75 75 ± 10% 67.5...82.5 60.7 5 108 1.4
TGL34-75A 75 ± 5% 71.3...78.8 64.1 5 103 1.5
TGL34-82 82 ± 10% 73.8...90.2 66.4 5 118 1.3
TGL34-82A 82 ± 5% 77.9...86.1 70.1 5 113 1.3
TGL34-91 91 ± 10% 81.9...100 73.7 5 131 1.1
TGL34-91A 91 ± 5% 86.5...95.5 77.8 5 125 1.2
TGL34-100 100 ± 10% 90.0...110 81.0 5 144 1.0
TGL34-100A 100 ± 5% 95.0...105 85.5 5 137 1.1
TGL34-110 110 ± 10% 99.0...121 89.2 5 158 0.9
TGL34-110A 110 ± 5% 105...116 94.0 5 152 1.0
TGL34-120 120 ± 10% 108...132 97.2 5 173 0.9
TGL34-120A 120 ± 5% 114...126 102 5 165 0.9
TGL34-130 130 ± 10% 117...143 105 5 187 0.8
TGL34-130A 130 ± 5% 124...137 111 5 179 0.8
TGL34-150 150 ± 10% 135...165 121 5 215 0.7
TGL34-150A 150 ± 5% 143...158 128 5 207 0.7
TGL34-160 160 ± 10% 144...176 130 5 230 0.7
TGL34-160A 160 ± 5% 152...168 136 5 219 0.7
TGL34-170 170 ± 10% 153...187 138 5 244 0.6
TGL34-170A 170 ± 5% 162...179 145 5 234 0.6
TGL34-180 180 ± 10% 162...198 146 5 258 0.6
TGL34-180A 180 ± 5% 171...189 154 5 246 0.6
TGL34-200 200 ± 10% 180...220 162 5 287 0.5
TGL34-200A 200 ± 5% 190...210 171 5 274 0.5
For bidirectional types (suffix “C” or “CA”), electrical characteristics apply in both directions.
Für bidirektionale Dioden (Suffix “C” oder “CA”) gelten die elektrischen Werte in beiden Richtungen.
© Diotec Semiconductor AG http://www.diotec.com/ 3