https://www.phoenixcontact.com/us/products/2811103
01/16/2021Page3/6
Voltage measuring transducers-MCR-VAC-UI-O-DC-2811103
Technical data
Output data
4 mA ... 20 mA
Max. output current 30 mA
Load/output load current output < 500 Ω
Ripple < 50 mVPP
Power supply
Supply voltage range 18.5 VDC ... 30.2 VDC
Max. current consumption < 45 mA
Connection data
Connection method Pluggable screw connection
Connection technology Screw connection
Stripping length 8 mm
Screw thread M3
Conductor cross section solid 0.2 mm² ... 2.5 mm²
Conductor cross section flexible 0.2 mm² ... 2.5 mm²
Conductor cross section AWG 24 ... 14
General
Maximum transmission error < 1.5 % (of final value)
Temperature coefficient, typical 0.02 %/K (50/60Hz)
Frequency measuring range 45 Hz ... 400 Hz
Alignment zero ± 20 %
Alignment span ± 20 %
Step response (10-90%) 250 ms
Overvoltage category III
Degree of pollution 2
Rated insulation voltage 300 VDC
Test voltage input/output 3.3 kV (50 Hz, 1 min.)
Test voltage input/power supply 3.3 kV (50 Hz, 1 min.)
Test voltage output/power supply 1 kV (50 Hz, 1 min.)
Electromagnetic compatibility Conformance with EMC directive
Noise emission EN 61000-6-4
Noise immunity EN 61000-6-2
Color green
Housing material Polyamide PA non-reinforced
Standards and Regulations
Electromagnetic compatibility Conformance with EMC directive