1
www.omron247.com
Safety Monitoring Relays
SR101A
Single-Channel Safety Monitoring Relay
Power requirements—the SR101A will accept 24 VAC/DC or 115 VAC
Inputs—a single N/C input channel, not monitored, is provided
Outputs—the SR101A has two N/O outputs to route power to the coils of power
contactors
External Device Monitoring (EDM) is provided with a N/C loop between S11
and S21 on the SR101A
Reset mode—an automatic reset mode is provided with the SR101A
R
C US
Specifications
Electrical All Models SR101A01 SR101A02
Power Supply: ±10%, 50-60 Hz 24 VAC/DC 115 VAC
Power Consumption: Approx. 1 VA
Safety Inputs: 1 N/C (not monitored)
Outputs: 2 N/O
Output Rating AC: Inductive AC-15, 4 A/230 V
Output Rating DC: Inductive DC-13, 2 A/24 V
Min Switched Current/Voltage: 20 mA/24 V
Impulse Withstand Voltage: 2500 V
Max Drop-Out Time: 75 ms
Max Output Fuse: 6 A quick-acting fuse or 4 A slow-acting
Reset Mode: Automatic (S11-S21)
Contactor Monitoring: N/C loop S11-S21
Mechanical
Mounting: 35 mm (1.38 in.) DIN rail
Case Material: Fiber-filled Polyamide PA6.6
Max Wire Size: 1 x 2.5 mm (14 AWG) stranded
Weight: 230 g (8.1 oz.)
Color: Red
External Switches: None
Indication: Green = K1 Closed, Green = K2 Closed
Mechanical Life: 1 x 10 7 operations
Environmental
Enclosure Protection: IP20 terminals, IP40 (NEMA 1) housing
Operating Temperature: 24 VAC/DC: -15 to 60°C (5 to 140°F)
115 VAC: -15 to 40°C (-5 to 104°F)
Humidity: 93% RH at 104°C (219°F)
Compliance
Standards: EN60439-1, EN60947-1/5/7, EN61000-6, EN62061, EN ISO 13849-1
Approvals/Listings: CE marked for all applicable directives, UL and C-UL, TÜV Rheinland
Specifications are subject to change without notice.
Note:
The safety contacts of the STI switches are described as normally closed (N/C)—i.e., with the guard closed,
actuator in place, and the machine able to be started.
Conforms to EN60439-1, EN60947-1/5/7,
EN61000-6, EN62061, EN ISO 13849-1
UL and C-UL listed
TÜV Rheinland approved
2
www.omron247.com
Output Contact
Arrangements
Terminal Connections
Application
SR101A
A1
A2
SUPPLY
13
14
SAFETY
OUTPUT 1
N/O
23
24
SAFETY
OUTPUT 2
N/O
S21
S11
EDM AND
RESET
Terminal Pin Assignments
24 VAC/DC, 110 VAC
BLUE
BROWN
MA SERIES
INTERLOCK
SWITCH
K2K1
K1 (AUX)
K2 (AUX)
START
MOMENTARY
PUSH
BUTTON
STOP
MOMENTARY
PUSH
BUTTON
FUSE
M
K1
L1 L2 L3
M
K2
L1 L2
L3
CONTACT PROTECTION e.g. THERMAL CUT OUT
CONTACT PROTECTION e.g. THERMAL CUT OUT
EB SERIES
LATCHING
E-STOP
BUTTON
Relay control and
fault monitoring
Power supply
(S11 = 24 V)
K2
K1
A2
A1 S11 S21 13 23
14 24
+
+
SR101A
GUARD
CLOSED
FUSE FUSE
S11 A1
14 13
24 23
A2 S21
SR101A Safety Monitoring Relays
3
www.omron247.com
Ordering
Model Supply Inputs Outputs Part No.
SR101A01 24 VAC/DC 1 N/C 2 N/O 44510-1011
SR101A02 115 VAC 1 N/C 2 N/O 44510-1012
Dimensions (mm/in.)
Block Diagram
SR101A
DIN RAIL MOUNTING
35
1.38
99
3.9
114
4.5
22.5
0.885
Relay control and
fault monitoring
Power supply
(S11=24V)
A2 14 24
A1 S11 S21
K2
K1
+
+
13 23
A1 A2
DC
UB
+UB0V
AC L1 N
SR101A Safety Monitoring Relays