Freescale Semiconductor Data Sheet: Technical Data Document Number: MAG3110 Rev. 9.2, 02/2013 An Energy Efficient Solution by Freescale Xtrinsic MAG3110 Three-Axis, Digital MAG3110 Magnetometer Freescale's MAG3110 is a small, low-power, digital 3-axis magnetometer. The device can be used in conjunction with a 3-axis accelerometer to realize an orientation independent electronic compass that can provide accurate heading information. It features a standard I2C serial interface output and smart embedded functions. Top and Bottom View The MAG3110 is capable of measuring magnetic fields with an output data rate (ODR) up to 80 Hz; these output data rates correspond to sample intervals from 12.5 ms to several seconds. The MAG3110 is available in a plastic DFN package and it is guaranteed to operate over the extended temperature range of -40C to +85C. 10-PIN DFN 2 mm x 2 mm x 0.85 mm CASE 2154-02 Features * * * * * * * * * * 1.95 V to 3.6 V supply voltage (VDD) 1.62 V to VDD IO voltage (VDDIO) Ultra small 2 mm x 2 mm x 0.85 mm, 0.4 mm pitch, 10-pin package Full-scale range 1000 T Sensitivity of 0.10 T Noise down to 0.25 T rms Output Data Rates (ODR) up to 80 Hz 400 kHz Fast Mode compatible I2C interface Low-power, single-shot measurement mode RoHS compliant Top View 10 GND Cap-A 1 VDD 2 9 INT1 NC 3 8 VDDIO Cap-R 4 7 SCL GND 5 6 SDA Applications * Electronic Compass (e-compass) * Location-Based Services Pin Connections Ruggedized Target markets * Smartphones, personal navigation devices, robotics, UAVs, speed sensing, current sensing and wrist watches with embedded electronic compasses (e-compass) function. Table 1. Ordering information Part number I2C Address Package description Shipping MAG3110FCR1 0x0E DFN-10 Tape and Reel (1000) FXMS3110CDR1 0x0F DFN-10 Tape and Reel (1000) (c) 2011-2013 Freescale Semiconductor, Inc. All rights reserved. Contents 1 2 3 4 5 6 7 Block diagram and pin description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 1.1 Application circuit. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Operating and Electrical Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 2.1 Operating characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 2.2 Absolute maximum ratings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 2.3 Electrical characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 2.4 I2C Interface characteristics. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 2.5 I2C pullup resistor selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 Modes of Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 Functionality. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 4.1 Factory calibration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 4.2 Digital interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 Register Descriptions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 5.1 Sensor Status . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 5.2 Device ID . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18 5.3 User Offset Correction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18 5.4 Temperature . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19 5.5 Control Registers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19 Geomagnetic Field Maps. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22 PCB Guidelines . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24 7.1 Overview of Soldering Considerations. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24 7.2 Halogen Content . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24 7.3 PCB Mounting Recommendations. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24 Related Documentation The MAG3110 device features and operations are described in a variety of reference manuals, user guides, and application notes. To find the most-current versions of these documents: 1. Go to the Freescale homepage at: http://www.freescale.com/ 2. 3. 2 In the Keyword search box at the top of the page, enter the device number MAG3110. In the Refine Your Result pane on the left, click on the Documentation link. Sensors Freescale Semiconductor, Inc. 1 Block diagram and pin description SDA SCL X-axis Y-axis ADC MUX Digital Signal Processing and Control Z-axis Clock Oscillator Regulator + Reference Trim Logic INT1 VDD VDDIO Figure 1. Block diagram X 1 10 GND Cap-A 1 VDD 2 9 INT1 NC 3 8 VDDIO Cap-R 4 7 SCL GND 5 6 SDA Y Z (TOP VIEW) (TOP VIEW) Figure 2. Pin connections and measurement coordinate system MAG LYW L = WAFER LOT Y = LAST DIGIT OF YEAR W = WORK WEEK Figure 3. Device marking diagram MAG3110 Sensors Freescale Semiconductor, Inc. 3 Table 2. Pin descriptions 1.1 Pin Name Function 1 Cap-A 2 VDD 3 NC 4 Cap-R 5 GND GND 6 SDA I2C Serial Data 7 SCL I2C Serial Clock 8 VDDIO 9 INT1 Interrupt - active high output 10 GND GND Bypass cap for internal regulator Power supply, 1.95 V - 3.6 V Do not connect Magnetic reset pulse circuit capacitor connection Digital interface supply, 1.65 V - VDD Application circuit Device power is supplied through the VDD line. Power supply decoupling capacitors (100 nF ceramic) should be placed as near as possible to pins 1 and 2 of the device. Additionally a 1F (or larger) capacitor should be used for bulk decoupling of the VDD supply rail as shown in Figure 4. VDDIO supplies power for the digital I/O pins SCL, SDA, and INT1. The control signals SCL and SDA, are not tolerant of voltages more than VDDIO + 0.3 volts. If VDDIO is removed, the control signals SCL and SDA will clamp any logic signals through their internal ESD protection diodes. 100 nF 1 Cap-A GND 10 2 VDD INT1 9 3 NC VDDIO 8 4 Cap-R SCL 7 SCL 5 GND SDA 6 SDA INT1 VDDIO 100 nF 4.7 K 4.7 K VDD 1 F 100 nF 100 nF (Top view) Figure 4. Electrical connection MAG3110 4 Sensors Freescale Semiconductor, Inc. 2 Operating and Electrical Specifications 2.1 Operating characteristics Table 3. Operating characteristics @ VDD = 2.4 V, VDDIO = 1.8 V, T = 25C unless otherwise noted. Parameter Test Conditions Full-scale range Symbol Min FS Output data range(1) Typ Max 1000 -30000 Unit T +30000 LSB Sensitivity So 0.10 T/LSB Sensitivity change versus temperature Tcs 0.1 %/C 100 T Zero-flux offset accuracy Hysteresis (2) Non linearity Best fit straight line(3) Magnetometer output noise NL -1 (4) 0.25 1 % 0.3 1 %FS 0.4 OS = 00 OS = 01 0.35 Noise Sensor die-to-package misalignment error (yaw) Operating temperature range T rms OS = 10 0.3 OS = 11 0.25 D2PEyaw Top 0.37 -40 1.36 degrees +85 C 1. Output data range is the sum of 10000 LSBs full-scale range, 10000 LSBs user defined offset (provided that CTRL_REG2[RAW] = 0) and 10000 zero-flux offset. 2. Hysteresis is measured from 0 T to 1000 T to 0 T and from 0 T to -1000 T to 0 T. 3. Best-fit straight line over the 0 to 1000 T full-scale range. 4. OS = Over Sampling Ratio. MAG3110 Sensors Freescale Semiconductor, Inc. 5 2.2 Absolute maximum ratings Stresses above those listed as "absolute maximum ratings" may cause permanent damage to the device. This is a stress rating only and functional operation of the device under these conditions is not implied. Exposure to maximum rating conditions for extended periods may affect device reliability. Table 4. Maximum ratings Rating Symbol Value Unit VDD -0.3 to +3.6 V Vin -0.3 to VDDIO + 0.3 V BMAX 100,000 T Top -40 to +85 C TSTG -40 to +125 C Symbol Value Unit Human Body Model HBM 2000 V Machine Model MM 200 V CDM 500 V ILU 100 mA Supply voltage Input voltage on any control pin (SCL, SDA) Maximum applied magnetic/field Operating temperature range Storage temperature range Table 5. ESD and latchup protection characteristics Rating Charge Device Model Latchup current at T = 85C This device is sensitive to mechanical shock. Improper handling can cause permanent damage of the part or cause the part to otherwise fail. This device is sensitive to ESD, improper handling can cause permanent damage to the part. MAG3110 6 Sensors Freescale Semiconductor, Inc. 2.3 Electrical characteristics Table 6. Electrical characteristics @ VDD = 2.4 V, VDDIO = 1.8 V, T = 25C unless otherwise noted Parameter Test Conditions Supply voltage Interface supply voltage Supply current in ACTIVE mode Symbol Min Typ Max Unit VDD 1.95 2.4 3.6 V VDDIO 1.62 VDD V ODR(1)(2) 80 Hz, OS(1) = 00 900 ODR 40 Hz, OS(3) = 00 550 ODR 20 Hz, OS(3) = 00 275 ODR 10 Hz, OS(3) = 00 ODR 5 Hz, OS(3) = 00 Supply current drain in STANDBY mode 137.5 Idd A 68.8 ODR 2.5 Hz, OS(3) = 00 34.4 ODR 1.25 Hz, OS(3) = 00 17.2 ODR 0.63 Hz, OS = 00 8.6 Measurement mode off IddStby Digital high level input voltage SCL, SDA VIH Digital low level input voltage SCL, SDA VIL High level output voltage INT1 IO = 500 A Low level output voltage INT1 IO = 500 A Low level output voltage SDA IO = 500 A Output Data Rate (ODR) VOH 2 V 0.75*VDDIO 0.3* VDDIO 0.1* VDDIO VOLS 0.8*ODR V V 0.9*VDDIO VOL ODR A ODR V 0.1* VDDIO V 1.2 *ODR Hz Signal bandwidth BW ODR/2 Hz Boot time from power applied to boot complete BT 1.7 ms Ton 25 ms Turn-on time(4)(5) Operating temperature range 1. 2. 3. 4. 5. CTRL_REG1[OS] = 2'b01 Top -40 +85 C ODR = Output Data Rate; OS = Over Sampling Ratio. Please see Table 32 for all ODR and OSR setting combinations, as well as corresponding current consumption and noise levels. By design. Time to obtain valid data from STANDBY mode to ACTIVE Mode. In 80 Hz mode ODR. MAG3110 Sensors Freescale Semiconductor, Inc. 7 2.4 I2C Interface characteristics Table 7. I2C slave timing values(1) I2C Fast Mode Parameter Unit Symbol Min Max 0 400 SCL clock frequency Pullup = 1 k Cb = 20 pF fSCL Bus free time between STOP and START condition tBUF 1.3 s Repeated START hold time tHD;STA 0.6 s Repeated START setup time tSU;STA 0.6 s STOP condition setup time tSU;STO 0.6 s SDA data hold time(2) tHD;DAT 0.05(3) SDA valid time(5) kHz (4) s tVD;DAT 0.9(4) s SDA valid acknowledge time(6) tVD;ACK 0.9(4) s SDA setup time tSU;DAT 100(7) ns SCL clock low time tLOW 1.3 s SCL clock high time tHIGH 0.6 s SDA and SCL rise time tr 20 + 0.1Cb(8) 1000 ns SDA and SCL fall time(3) (8) (9) (10) tf 20 + 0.1Cb(8) 300 ns 50 ns Pulse width of spikes on SDA and SCL that must be suppressed by input filter tSP 1. All values are referred to VIH (min) and VIL (max) levels. 2. tHD;DAT is the data hold time that is measured from the falling edge of SCL; the hold time applies to data in transmission and the acknowledge. 3. A device must internally provide a hold time of at least 300 ns for the SDA signal (with respect to the VIH (min) of the SCL signal) to bridge the undefined region of the falling edge of SCL. 4. The maximum tHD;DAT could be must be less than the maximum of tVD;DAT or tVD;ACK by a transition time. This device may stretch the LOW period (tLOW) of the SCL signal. 5. tVD;DAT = time for Data signal from SCL LOW to SDA output (HIGH or LOW, depending on which one is worse). 6. tVD;ACK = time for Acknowledgement signal from SCL LOW to SDA output (HIGH or LOW, depending on which one is worse). 7. A Fast mode I2C device can be used in a Standard mode I2C system, but the requirement tSU;DAT 250 ns must then be met. This will automatically be the case if the device does not stretch the LOW period of the SCL signal. If such a device does stretch the LOW period of the SCL signal, it must output the next data bit to the SDA line tr(max) + tSU;DAT = 1000 + 250 = 1250 ns (according to the Standard mode I2C specification) before the SCL line is released. Also the acknowledge timing must meet this setup time. 8. Cb = total capacitance of one bus line in pF. 9. The maximum tf for the SDA and SCL bus lines is specified at 300 ns. The maximum fall time for the SDA output stage tf is specified at 250 ns. This allows series protection resistors to be connected in between the SDA and the SCL pins and the SDA/SCL bus lines without exceeding the maximum specified tf. 10.In Fast mode Plus, fall time is specified the same for both output stage and bus timing. If series resistors are used, designers should allow for this when considering bus timing. MAG3110 8 Sensors Freescale Semiconductor, Inc. Figure 5. I2C slave timing diagram 2.5 I2C pullup resistor selection The SCL and SDA signals are driven by open-drain buffers and a pullup resistor is required to make the signals rise to the high state. The value of the pullup resistors depends on the system I2C clock rate and the total capacitive load on the I2C bus. Higher resistance pullups will conserve power, at the expense of a slower rise time on the SCL and SDA lines (due to the RC time constant between the bus capacitance and the pullup resistor), and will limit the maximum I2C clock frequency that can be achieved. Lower resistance value pullup resistors consume more power, but enable higher I2C clock operating frequencies. I2C bus capacitance consists of the sum of the parasitic device and trace capacitances present. In general, longer bus traces and an increased number of devices lead to higher total bus capacitance and will require lower value pullup resistors to enable a given frequency of operation. For Standard mode operation, pullup resistor values between 5 k and 10 k are recommended as a starting point, but may need to be lowered depending on the number of devices present on the bus and the total bus capacitance. For Fast mode operation, pullup resistor values of 1k (or lower) may be required. MAG3110 Sensors Freescale Semiconductor, Inc. 9 3 Modes of Operation Table 8. Modes of operation description Mode I2C Bus State STANDBY I2C communication is possible. Only POR and Digital blocks are enabled, the Analog subsystem is disabled. ACTIVE I2C communication is possible. All blocks are enabled (POR, Digital, Analog). 4 Function Description Functionality MAG3110 is a small low-power, digital output, 3-axis linear magnetometer packaged in a 10-pin DFN. The device contains a magnetic transducer for sensing and an ASIC for control and digital I2C communications. 4.1 Factory calibration MAG3110 is factory calibrated for sensitivity and temperature coefficient of sensitivity. All factory calibration coefficients are automatically applied by the ASIC before a measurement is taken and the result written to registers 0x01 to 0x06 (Section 5, "Register Descriptions," on page 15). The magnetic offset registers in addresses 0x09 to 0x0E are not a factory calibration offset but allow the user to define a hardiron offset which can be automatically subtracted from the magnetic field readings (see Section 4.2.4, "User offset corrections," on page 12). 4.2 Digital interface Table 9. Serial interface pin description Pin name VDDIO Pin description IO voltage SCL I2C Serial Clock SDA I2C Serial Data INT Data ready interrupt pin There are two signals associated with the I2C bus: the Serial Clock Line (SCL) and the Serial Data line (SDA). External pullup resistors (connected to VDDIO) are needed for SDA and SCL. When the bus is free, both lines are high. The I2C interface is compliant with Fast mode (400 kHz), and Normal mode (100 kHz) I2C standards. 4.2.1 General I2C operation There are two signals associated with the I2C bus: the Serial Clock Line (SCL) and the Serial Data line (SDA). The latter is a bidirectional line used for sending and receiving the data to/from the interface. External pullup resistors connected to VDDIO are required for SDA and SCL. When the bus is free both the lines are high. The I2C interface is compliant with fast mode (400 kHz), and normal mode (100 kHz) I2C standards. Operation at frequencies higher than 400 kHz is possible, but depends on several factors including the pullup resistor values, and total bus capacitance (trace + device capacitance). A transaction on the bus is started with a start condition (ST) signal, which is defined as a HIGH-to-LOW transition on the data line while the SCL line is held HIGH. After the ST signal has been transmitted by the master, the bus is considered busy. The next byte of data transmitted contains the slave address in the first seven bits, and the eighth bit, the read/write bit, indicates whether the master is receiving data from the slave or transmitting data to the slave. When an address is sent, each device in the system compares the first seven bits after the ST condition with its own address. If they match, the device considers itself addressed by the master. The 9th clock pulse, following the slave address byte (and each subsequent byte) is the acknowledge (ACK). The transmitter must release the SDA line during the ACK period. The receiver must then pull the data line low so that it remains stable low during the high period of the acknowledge clock period. The number of bytes per transfer is unlimited. If a receiver can't receive another complete byte of data until it has performed some other function, it can hold the clock line, SCL low to force the transmitter into a wait state. Data transfer only continues when the receiver is ready for another byte and releases the data line. This delay action is called clock stretching. Not all receiver devices support clock stretching. Not all master devices recognize clock stretching. This part supports clock stretching. MAG3110 10 Sensors Freescale Semiconductor, Inc. A low to high transition on the SDA line while the SCL line is high is defined as a stop condition (SP) signal. A write or burst write is always terminated by the master issuing the SP signal. A master should properly terminate a read by not acknowledging a byte at the appropriate time in the protocol. A master may also issue a repeated start signal (SR) during a transfer. The 7-bit I2C slave address assigned to MAG3110 is 0x0E (standard); the address assigned to FXMS3110CD is 0x0F (WindowsTM 8). 4.2.2 I2C Read/Write operations Single byte read The master (or MCU) transmits a start condition (ST) to the MAG3110, followed by the slave address, with the R/W bit set to "0" for a write, and the MAG3110 sends an acknowledgement. Then the master (or MCU) transmits the address of the register to read and the MAG3110 sends an acknowledgement. The master (or MCU) transmits a repeated start condition (SR), followed by the slave address with the R/W bit set to "1" for a read from the previously selected register. The MAG3110 then acknowledges and transmits the data from the requested register. The master does not acknowledge (NAK) the transmitted data, but transmits a stop condition to end the data transfer. Multiple byte read When performing a multi-byte or "burst" read, the MAG3110 automatically increments the register address read pointer after a read command is received. Therefore, after following the steps of a single byte read, multiple bytes of data can be read from sequential registers after each MAG3110 acknowledgment (AK) is received until a no acknowledge (NAK) occurs from the master followed by a stop condition (SP) signaling the end of transmission. Single byte write To start a write command, the master transmits a start condition (ST) to the MAG3110, followed by the slave address with the R/W bit set to "0" for a write, and the MAG3110 sends an acknowledgement. Then the master (or MCU) transmits the address of the register to write to, and the MAG3110 sends an acknowledgement. Then the master (or MCU) transmits the 8-bit data to write to the designated register and the MAG3110 sends an acknowledgement that it has received the data. Since this transmission is complete, the master transmits a stop condition (SP) to end the data transfer. The data sent to the MAG3110 is now stored in the appropriate register. Multiple byte write The MAG3110 automatically increments the register address write pointer after a write command is received. Therefore, after following the steps of a single byte write, multiple bytes of data can be written to sequential registers after each MAG3110 acknowledgment (ACK) is received. MAG3110 Sensors Freescale Semiconductor, Inc. 11 < Single Byte Read > Master ST Device Address[6:0] W Register Address[7:0] AK Slave SR Device Address[6:0] R AK NAK SP AK Data[7:0] < Multiple Byte Read > Master ST Device Address[6:0] W Register Address[7:0] AK Slave AK Master Data[7:0] R AK AK Data[7:0] Slave SR Device Address[6:0] AK AK NAK Data[7:0] SP Data[7:0] < Multiple Byte Write > Master ST Device Address[6:0] W Register Address[7:0] AK Slave Data[7:0] AK Data[7:0] AK SP AK < Single Byte Write > Master ST Device Address[6:0] W Register Address[7:0] AK Slave Data[7:0] AK SP AK Legend ST: Start Condition SR: Repeated Start Condition SP: Stop Condition AK: Acknowledge NAK: No Acknowledge R: Read = 1 W: Write = 0 Figure 6. I2C timing diagram 4.2.3 Fast Read mode When the Fast Read (FR) bit is set (CTRL_REG1, 0x10, bit 2), the MSB 8-bit data is read through the I2C bus. Auto-increment is set to skip over the LSB data. When FR bit is cleared, the complete 16-bit data is read accessing all 6 bytes sequentially (OUT_X_MSB, OUT_X_LSB, OUT_Y_MSB, OUT_Y_LSB, OUT_Z_MSB, OUT_Z_LSB). 4.2.4 User offset corrections The 2's complement user offset correction register values are used to compensate for correcting the X, Y, and Z-axis after device board mount. These values may be used to compensate for hard-iron interference and zero-flux offset of the sensor. Depending on the setting of the CTRL_REG2[RAW] bit, the magnetic field sample data is corrected with the user offset values (CTRL_REG2[RAW] = 0), or can be read out uncorrected for user offset values (CTRL_REG2[RAW] = 1). The factory calibration for gain, offset and temperature compensation is always automatically applied irrespective of the setting of the CTRL_REG2[RAW] bit which only controls whether the user offset correction values stored in the OFF_X/Y/Z registers are applied to the output data. In order to not saturate the sensor output, user written offset values should be within the range of 10,000 counts. MAG3110 12 Sensors Freescale Semiconductor, Inc. 4.2.5 INT1 The DR_STATUS register (see section 5.1.1) contains the ZYXDR bit which denotes the presence of new measurement data on one or more axes. Software polling can be used to detect the transition of the ZYXDR bit from 0 to 1 but, since the ZYXDR bit is also logically connected to the INT1 pin, a more efficient approach is to use INT1 to trigger a software interrupt when new measurement data is available as follows: 1. 2. 3. 4. 5. 4.2.6 Enable automatic resets by setting AUTO_MRST_EN bit in CTRL_REG2 (CTRL_REG2 = 0b1XXXXXX). Put MAG3110 in ACTIVE mode (CTRL_REG1 = 0bXXXXXX01). Idle until INT1 goes HIGH and activates an interrupt service routine in the user software. Read magnetometer data as required from registers 0x01 to 0x06. INT1 is cleared when register 0x01 OUT_X_MSB is read. Return to idle in step 3. Triggered Measurements Set the TM bit in CTRL_REG1 when you want the part to acquire only one sample on each axis. See table below for details. Table 10. AC TM Description 0 0 0 1 1 0 The ASIC will perform continuous measurements based on the current OSR and ODR settings. 1 1 The ASIC will continue the current measurement at the fastest applicable ODR for the user programmed OSR. The ASIC will return back to the programmed ODR after completing the triggered measurement. ASIC is in low power standby mode. The ASIC will exit standby mode, perform one measurement cycle based on the programmed ODR and OSR setting, update the I2C data registers and re- enter standby mode. The anti-aliasing filter in the A/D converter has a finite delay before the output "settles". The output data for the first ODR period after getting out of Standby mode is expected to be slightly off. This effect will be more pronounced for the lower over-sampling settings since with higher settings the error of the first acquisition will be averaged over the total number of samples. Therefore, it is not recommended to use TRIGGER MODE (CTRL_REG1[AC] =0, CTRL_REG1[TM] =1) measurements for applications that require high accuracy, especially with low over-sampling settings. MAG3110 Sensors Freescale Semiconductor, Inc. 13 4.2.7 MAG3110 Setup Examples Continuous measurements with ODR = 80 Hz, OSR = 1 1. 2. 3. Enable automatic magnetic sensor resets by setting bit AUTO_MRST_EN in CTRL_REG2. (CTRL_REG2 = 0x80) Put MAG3110 in active mode 80 Hz ODR with OSR = 1 by writing 0x01 to CTRL_REG1 (CTRL_REG1 = 0x01) At this point it is possible to sync with MAG3110 utilizing INT1 pin or using polling of the DR_STATUS register as explained in section 4.2.5. Continuous measurements with ODR = 0.63 Hz, OSR = 2 1. 2. 3. Enable automatic magnetic sensor resets by setting bit AUTO_MRST_EN in CTRL_REG2. (CTRL_REG2 = 0x80) Put MAG3110 in active mode 0.63 Hz ODR with OSR = 2 by writing 0xC9 to CTRL_REG1 (CTRL_REG1 = 0xC9) At this point, it is possible to sync with MAG3110 utilizing INT1 pin or using polling of the DR_STATUS register as explained in section 4.2.5. Triggered measurements with ODR = 10 Hz, OSR = 8 1. 2. 3. 4. Enable automatic magnetic sensor resets by setting bit AUTO_MRST_EN in CTRL_REG2. (CTRL_REG2 = 0x80) Initiate a triggered measurement with OSR = 128 by writing 0b00011010 to CTRL_REG1 (CTRL_REG1 = 0b00011010). MAG3110 will acquire the triggered measurement and go back into STANDBY mode. It is possible at this point to sync on INT1 or resort to polling of DR_STATUS register to read the acquired data out of MAG3110. Go back to step 2 based on application needs. MAG3110 14 Sensors Freescale Semiconductor, Inc. 5 Register Descriptions Table 11. Register Address Map Auto-Increment Name Type Register Address Address (Fast Read)(1) Default Value DR_STATUS(2) R 0x00 0x01 0000 0000 OUT_X_MSB(2) R 0x01 0x02 (0x03) data Bits [15:8] of X measurement OUT_X_LSB(2) R 0x02 0x03 data Bits [7:0] of X measurement OUT_Y_MSB(2) R 0x03 0x04 (0x05) data Bits [15:8] of Y measurement OUT_Y_LSB(2) R 0x04 0x05 data Bits [7:0] of Y measurement OUT_Z_MSB(2) R 0x05 0x06 (0x07) data Bits [15:8] of Z measurement OUT_Z_LSB(2) R 0x06 0x07 data Bits [7:0] of Z measurement WHO_AM_I(2) R 0x07 0x08 0xC4 Device ID Number SYSMOD(2) R 0x08 0x09 data Current System Mode OFF_X_MSB R/W 0x09 0x0A 0000 0000 Bits [14:7] of user X offset OFF_X_LSB R/W 0x0A 0x0B 0000 0000 Bits [6:0] of user X offset OFF_Y_MSB R/W 0x0B 0x0C 0000 0000 Bits [14:7] of user Y offset OFF_Y_LSB R/W 0x0C 0x0D 0000 0000 Bits [6:0] of user Y offset OFF_Z_MSB R/W 0x0D 0x0E 0000 0000 Bits [14:7] of user Z offset OFF_Z_LSB R/W 0x0E 0x0F 0000 0000 Bits [6:0] of user Z offset DIE_TEMP(2) R 0x0F 0x10 data CTRL_REG1(3) R/W 0x10 0x11 0000 0000 Operation modes CTRL_REG2(3) R/W 0x11 0x12 0000 0000 Operation modes Comment Data ready status per axis Temperature, signed 8 bits in C 1. Fast Read mode for quickly reading the Most Significant Bytes (MSB) of the sampled data. 2. Register contents are preserved when transitioning from "ACTIVE" to "STANDBY" mode. 3. Modification of this register's contents can only occur when device is "STANDBY" mode, except the TM and AC bit fields in CTRL_REG1 register. MAG3110 Sensors Freescale Semiconductor, Inc. 15 5.1 Sensor Status 5.1.1 DR_STATUS (0x00) Data Ready Status This read-only status register provides the acquisition status information on a per-sample basis, and reflects real-time updates to the OUT_X, OUT_Y, and OUT_Z registers. Table 12. DR_STATUS Register Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 ZYXOW ZOW YOW XOW ZYXDR ZDR YDR XDR Table 13. DR_STATUS Descriptions ZYXOW X, Y, Z-axis Data Overwrite. Default value: 0. 0: No data overwrite has occurred. 1: Previous X or Y or Z data was overwritten by new X or Y or Z data before it was completely read. ZOW Z-axis Data Overwrite. Default value: 0. 0: No data overwrite has occurred. 1: Previous Z-axis data was overwritten by new Z-axis data before it was read. YOW Y-axis Data Overwrite. Default value: 0. 0: No data overwrite has occurred. 1: Previous Y-axis data was overwritten by new Y-axis data before it was read. XOW X-axis Data Overwrite. Default value: 0 0: No data overwrite has occurred. 1: Previous X-axis data was overwritten by new X-axis data before it was read. ZYXDR ZDR YDR X or Y or Z-axis new Data Ready. Default value: 0. 0: No new set of data ready. 1: New set of data is ready. Z-axis new Data Available. Default value: 0. 0: No new Z-axis data is ready. 1: New Z-axis data is ready. Z-axis new Data Available. Default value: 0. 0: No new Y-axis data is ready. 1: New Y-axis data is ready. XDR Z-axis new Data Available. Default value: 0. 0: No new X-axis data is ready. 1: New X-axis data is ready. ZYXOW is set to 1 whenever new data is acquired before completing the retrieval of the previous set. This event occurs when the content of at least one data register (i.e. OUT_X, OUT_Y, OUT_Z) has been overwritten. ZYXOW is cleared when the highbytes of the data (OUT_X_MSB, OUT_Y_MSB, OUT_Z_MSB) of all active channels are read. ZOW is set to 1 whenever new Z-axis acquisition is completed before the retrieval of the previous data. When this occurs the previous data is overwritten. ZOW is cleared any time OUT_Z_MSB register is read. YOW is set to 1 whenever new Y-axis acquisition is completed before the retrieval of the previous data. When this occurs the previous data is overwritten. YOW is cleared any time OUT_Y_MSB register is read. XOW is set to 1 whenever new X-axis acquisition is completed before the retrieval of the previous data. When this occurs the previous data is overwritten. XOW is cleared any time OUT_X_MSB register is read. ZYXDR signals that new acquisition for any of the enabled channels is available. ZYXDR is cleared when the high-bytes of the data (OUT_X_MSB, OUT_Y_MSB, OUT_Z_MSB) of all the enabled channels are read. ZDR is set to 1 whenever new Z-axis data acquisition is completed. ZDR is cleared any time OUT_Z_MSB register is read. YDR is set to 1 whenever new Y-axis data acquisition is completed. YDR is cleared any time OUT_Y_MSB register is read. XDR is set to 1 whenever new X-axis data acquisition is completed. XDR is cleared any time OUT_X_MSB register is read. MAG3110 16 Sensors Freescale Semiconductor, Inc. 5.1.2 OUT_X_MSB (0x01), OUT_X_LSB (0x02), OUT_Y_MSB (0x03), OUT_Y_LSB (0x04), OUT_Z_MSB (0x05), OUT_Z_LSB (0x06) X-axis, Y-axis, and Z-axis 16-bit output sample data of the magnetic field strength expressed as signed 2's complement numbers. When RAW bit is set (CTRL_REG2[RAW] = 1), the output range is between -20,000 to 20,000 bit counts (the combination of the 1000 T full scale range and the zero-flux offset ranging up to 1000 T). When RAW bit is clear (CTRL_REG2[RAW] = 0), the output range is between -30,000 to 30,000 bit counts when the user offset ranging between -10,000 to 10,000 bit counts are included. The DR_STATUS register, OUT_X_MSB, OUT_X_LSB, OUT_Y_MSB, OUT_Y_LSB, OUT_Z_MSB, and OUT_Z_LSB are stored in the auto-incrementing address range of 0x00 to 0x06. Data acquisition is a sequential read of 6 bytes. If the Fast Read (FR) bit is set in CTRL_REG1 (0x10), auto-increment will skip over LSB of the X, Y, Z sample registers. This will shorten the data acquisition from 6 bytes to 3 bytes. If the LSB registers are directly addressed, the LSB information can still be read regardless of FR bit setting. The preferred method for reading data registers is the burst-read method where the user application acquires data sequentially starting from register 0x01. If register 0x01 is not read first, the rest of the data registers (0x02 - 0x06) will not be updated with the most recent acquisition. It is still possible to address individual data registers, however register 0x01 must be read prior to ensure that the latest acquisition data is being read. Table 14. OUT_X_MSB Register Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 XD15 XD14 XD13 XD12 XD11 XD10 XD9 XD8 Table 15. OUT_X_LSB Register Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 XD7 XD6 XD5 XD4 XD3 XD2 XD1 XD0 Table 16. OUT_Y_MSB Register Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 YD15 YD14 YD13 YD12 YD11 YD10 YD9 YD8 Table 17. OUT_Y_LSB Register Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 YD7 YD6 YD5 YD4 YD3 YD2 YD1 YD0 Table 18. OUT_Z_MSB Register Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 ZD15 ZD14 ZD13 ZD12 ZD11 ZD10 ZD9 ZD8 Table 19. OUT_Z_LSB Register Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 ZD6 ZD6 ZD5 ZD4 ZD3 ZD2 ZD1 ZD0 MAG3110 Sensors Freescale Semiconductor, Inc. 17 5.2 Device ID 5.2.1 WHO_AM_I (0x07) Device identification register. This read-only register contains the device identifier which is set to 0xC4. This value is factory programmed. Table 20. WHO_AM_I Register Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 1 1 0 0 0 1 0 0 5.2.2 SYSMOD (0x08) The read-only system mode register indicates the current device operating mode. Table 21. SYSMOD Register Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 0 0 0 0 0 0 SYSMOD1 SYSMOD0 Table 22. SYSMOD Description SYSMOD System Mode. Default value: 00. 00: STANDBY mode. 01: ACTIVE mode, RAW data. 10: ACTIVE mode, non-RAW user-corrected data. 5.3 User Offset Correction 5.3.1 OFF_X_MSB (0x09), OFF_X_LSB (0x0A), OFF_Y_MSB (0x0B), OFF_Y_LSB (0x0C), OFF_Z_MSB (0x0D), OFF_Z_LSB (0x0E) These registers contain the X-axis, Y-axis, and Z-axis user defined offsets in 2's complement format which are used when CTRL_REG2[RAW] = 0 (see section 5.5.2) to correct for the MAG3110 zero-flux offset and for hard-iron offsets on the PCB caused by external components. The maximum range for the user offsets is in the range -10,000 to 10,000 bit counts comprising the sum of the correction for the sensor zero-flux offset and the PCB hard-iron offset (range -1000 T to 1000 T or -10,000 to 10,000 bit counts). The user offsets are automatically subtracted by the MAG3110 logic when CTRL_REG2[RAW] = 0 before the magnetic field readings are written to the data measurement output registers OUT_X/Y/Z. The maximum range of the X, Y and Z data measurement registers when CTRL_REG2[RAW] = 0 is therefore -30,000 to 30,000 bit counts and is computed without clipping. The user offsets are not subtracted when CTRL_REG2[RAW] = 1. The least significant bit of the user defined X, Y and Z offsets is forced to be zero irrespective of the value written by the user. If the MAG3110 zero-flux offset and PCB hard-iron offset corrections are performed by an external microprocessor (the most likely scenario) then the user offset registers can be ignored and the CTRL_REG2[RAW] bit should be set to 1. The user offset registers should not be confused with the factory calibration corrections which are not user accessible and are always applied to the measured magnetic data irrespective o the setting of CTRL_REG2[RAW]. Table 23. OFF_X_MSB Register Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 XD14 XD13 XD12 XD11 XD10 XD9 XD8 XD7 Table 24. OFF_X_LSB Register Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 XD6 XD5 XD4 XD3 XD2 XD1 XD0 0 Table 25. OFF_Y_MSB Register Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 YD14 YD13 YD12 YD11 YD10 YD9 YD8 YD7 MAG3110 18 Sensors Freescale Semiconductor, Inc. Table 26. OFF_Y_LSB Register Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 YD6 YD5 YD4 YD3 YD2 YD1 YD0 0 Table 27. OFF_Z_MSB Register Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 ZD14 ZD13 ZD12 ZD11 ZD10 ZD9 ZD8 ZD7 Table 28. OFF_Z_LSB Register Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 ZD6 ZD5 ZD4 ZD3 ZD2 ZD1 ZD0 0 5.4 Temperature 5.4.1 DIE_TEMP (0x0F) The register contains the die temperature in C expressed as an 8-bit 2's complement number. The sensitivity of the temperature sensor is factory trimmed to 1C/LSB. The temperature sensor offset is not factory trimmed and must be calibrated by the user software if higher absolute accuracy is required. Note: The register allows for temperature measurements from -128C to 127C but the output range is limited to -40C to 125C. The temperature data is updated on every measurement cycle. Table 29. TEMP Register Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 T7 T6 T5 T4 T3 T2 T1 T0 5.5 Control Registers 5.5.1 CTRL_REG1 (0x10) Note: Except for STANDBY mode selection (Bit 0, AC), the device must be in STANDBY mode to change any of the fields within CTRL_REG1 (0x10). Table 30. CTRL_REG1 Register Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 DR2 DR1 DR0 OS1 OS0 FR TM AC Table 31. CTRL_REG1 Description DR[2:0] Output data rate selection. Default value: 000. See Table 32 for more information. OS [1:0] This register configures the over sampling ratio for the measurement. The selected number of samples is collected and averaged before being placed in the output data registers. The oversampling setting made here applies to both the triggered and active modes of operation. Default value: 00. See Table 32 for more information. FR Fast Read selection. Default value: 0. 0: The full 16-bit values are read. 1: Fast Read, 8-bit values read from the MSB registers (Auto-increment skips over the LSB register in burst-read mode). TM Trigger immediate measurement. Default value: 0 0: Normal operation based on AC condition. 1: Trigger measurement. If part is in ACTIVE mode, any measurement in progress will continue with the highest ODR possible for the selected OSR. In STANDBY mode triggered measurement will occur immediately and part will return to STANDBY mode as soon as the measurement is complete. AC Operating mode selection. Note: see section 4.2.6 for details. Default value: 0. 0: STANDBY mode. 1: ACTIVE mode. ACTIVE mode will make periodic measurements based on values programmed in the Data Rate (DR) and Over Sampling Ratio bits (OS). MAG3110 Sensors Freescale Semiconductor, Inc. 19 Table 32. Over-Sampling Ratio and Data Rate Description DR2 DR1 DR0 OS1 OS0 Output Rate (Hz) Over Sample Ratio ADC Rate (Hz) Current Typ A Noise Typ T rms 0 0 0 0 0 80.00 16 1280 900.0 0.4 0 0 0 0 1 40.00 32 1280 900.0 0.35 0 0 0 1 0 20.00 64 1280 900.0 0.3 0 0 0 1 1 10.00 128 1280 900.0 0.25 0 0 1 0 0 40.00 16 640 550.0 0.4 0 0 1 0 1 20.00 32 640 550.0 0.35 0 0 1 1 0 10.00 64 640 550.0 0.3 0 0 1 1 1 5.00 128 640 550.0 0.25 0 1 0 0 0 20.00 16 320 275.0 0.4 0 1 0 0 1 10.00 32 320 275.0 0.35 0 1 0 1 0 5.00 64 320 275.0 0.3 0 1 0 1 1 2.50 128 320 275.0 0.25 0 1 1 0 0 10.00 16 160 137.5 0.4 0 1 1 0 1 5.00 32 160 137.5 0.35 0 1 1 1 0 2.50 64 160 137.5 0.3 0 1 1 1 1 1.25 128 160 137.5 0.25 1 0 0 0 0 5.00 16 80 68.8 0.4 1 0 0 0 1 2.50 32 80 68.8 0.35 1 0 0 1 0 1.25 64 80 68.8 0.3 1 0 0 1 1 0.63 128 80 68.8 0.25 1 0 1 0 0 2.50 16 80 34.4 0.4 1 0 1 0 1 1.25 32 80 34.4 0.35 1 0 1 1 0 0.63 64 80 34.4 0.3 1 0 1 1 1 0.31 128 80 34.4 0.25 1 1 0 0 0 1.25 16 80 17.2 0.4 1 1 0 0 1 0.63 32 80 17.2 0.35 1 1 0 1 0 0.31 64 80 17.2 0.3 1 1 0 1 1 0.16 128 80 17.2 0.25 1 1 1 0 0 0.63 16 80 8.6 0.4 1 1 1 0 1 0.31 32 80 8.6 0.35 1 1 1 1 0 0.16 64 80 8.6 0.3 1 1 1 1 1 0.08 128 80 8.6 0.25 MAG3110 20 Sensors Freescale Semiconductor, Inc. 5.5.2 CTRL_REG2 (0x11) Table 33. CTRL_REG2 Register Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 AUTO_MRST_EN -- RAW Mag_RST -- -- -- -- Table 34. CTRL_REG2 Description Automatic Magnetic Sensor Reset. Default value: 0. 0: Automatic magnetic sensor resets disabled. 1: Automatic magnetic sensor resets enabled. AUTO_MRST_EN Similar to Mag_RST, however, the resets occur automatically before each data acquisition. This bit is recommended to be always explicitly enabled by the host application. This a WRITE ONLY bit and always reads back as 0. RAW Data output correction. Default value: 0. 0: Normal mode: data values are corrected by the user offset register values. 1: Raw mode: data values are not corrected by the user offset register values. Note: The factory calibration is always applied to the measured data stored in registers 0x01 to 0x06 irrespective of the setting of the RAW bit. Mag_RST Magnetic Sensor Reset (One-Shot). Default value: 0. 0: Reset cycle not active. 1: Reset cycle initiate or Reset cycle busy/active. When asserted, initiates a magnetic sensor reset cycle that will restore correct operation after exposure to an excessive magnetic field which exceeds the Full Scale Range (see Table 3) but is less than the Maximum Applied Magnetic Field (see Table 4). When the cycle is finished, value returns to 0. MAG3110 Sensors Freescale Semiconductor, Inc. 21 6 Geomagnetic Field Maps The magnitude of the geomagnetic field varies from 25 T in South America to about 60 T over Northern China. The horizontal component of the field varies from zero at the magnetic poles to 40 T. These web sites have further information: http://wdc.kugi.kyoto-u.ac.jp/igrf/ http://geomag.usgs.gov/ MAG3110 22 Sensors Freescale Semiconductor, Inc. Geomagnetic Field MAG3110 MAG3110 Sensitivity (0.1 T) Full-Scale Range (1000 T) MAG3110 Sensors Freescale Semiconductor, Inc. 23 7 PCB Guidelines Surface mount Printed Circuit Board (PCB) layout is a critical portion of the total design. The footprint for the surface mount packages must be the correct size to ensure proper solder connection interface between the PCB and the package. With the correct footprint, the packages will self-align when subjected to a solder reflow process. These guidelines are for soldering and mounting the Dual Flat No-Lead (DFN) package inertial sensors to PCBs. The purpose is to minimize the stress on the package after board mounting. The MAG3110 digital output magnetometers use the DFN package platform. This section describes suggested methods of soldering these devices to the PCB for consumer applications. Please see Freescale application note AN4247,"Layout Recommendation for PCBs Using a magnetometer Sensor" for a technical discussion on hard and soft-iron magnetic interference and general guidelines on layout and component selection applicable to any PCB using a magnetometer sensor. Freescale application note AN1902, "Quad Flat Pack No-Lead (QFN) Micro Dual Flat Pack No-Lead (DFN)" discusses the DFN package used by the MAG3110, PCB design guidelines for using DFN packages and temperature profiles for reflow soldering. 7.1 Overview of Soldering Considerations Information provided here is based on experiments executed on DFN devices. They do not represent exact conditions present at a customer site. Hence, information herein should be used as guidance only and process and design optimizations are recommended to develop an application specific solution. It should be noted that with the proper PCB footprint and solder stencil designs, the package will self-align during the solder reflow process. 7.2 Halogen Content This package is designed to be Halogen Free, exceeding most industry and customer standards. Halogen Free means that no homogeneous material within the assembly package shall contain chlorine (Cl) in excess of 700 ppm or 0.07% weight/weight or bromine (Br) in excess of 900 ppm or 0.09% weight/weight. 7.3 PCB Mounting Recommendations 1. 2. 3. 4. 5. 6. 7. The PCB land should be designed as Non Solder Mask Defined (NSMD) as shown in Figure 7. No additional via pattern underneath package. PCB land pad is 0.6 mm x 0.225 mm as shown in Figure 7. Solder mask opening = PCB land pad edge + 0.125 mm larger all around = 0.725 mm x 1.950 mm Stencil opening = PCB land pad -0.05 mm smaller all around = 0.55 mm x 0.175 mm. Stencil thickness is 100 or 125 mm. Do not place any components or vias at a distance less than 2 mm from the package land area. This may cause additional package stress if it is too close to the package land area. 8. Signal traces connected to pads are as symmetric as possible. Put dummy traces on NC pads in order to have same length of exposed trace for all pads. 9. Use a standard pick and place process and equipment. Do not use a hand soldering process. 10. Assemble PCB when in an enclosure. Using caution, determine the position of screw down holes and any press fit. It is important that the assembled PCB remain flat after assembly to keep electronic operation of the device optimal. 11. The PCB should be rated for the multiple lead-free reflow condition with max 260C temperature. 12. No copper traces on top layer of PCB under the package. This will cause planarity issues with board mount. Freescale DFN sensors are compliant with Restrictions on Hazardous Substances (RoHS), having halide free molding compound (green) and lead-free terminations. These terminations are compatible with tin-lead (Sn-Pb) as well as tin-silver-copper (Sn-Ag-Cu) solder paste soldering processes. Reflow profiles applicable to those processes can be used successfully for soldering the devices. MAG3110 24 Sensors Freescale Semiconductor, Inc. 0.200 0.400 0.200 0.225 0.600 0.400 Package Footprint PCB Cu Footprint 0.725 0.550 1.950 0.175 Stencil Opening Solder Mask Opening Figure 7. Footprints and Soldering Masks (dimensions in mm) MAG3110 Sensors Freescale Semiconductor, Inc. 25 PACKAGE DIMENSIONS CASE 2154-02 ISSUE A 10-PIN DFN MAG3110 26 Sensors Freescale Semiconductor, Inc. PACKAGE DIMENSIONS CASE 2154-02 ISSUE A 10-PIN DFN MAG3110 Sensors Freescale Semiconductor, Inc. 27 PACKAGE DIMENSIONS CASE 2154-02 ISSUE A 10-PIN DFN MAG3110 28 Sensors Freescale Semiconductor, Inc. Table 35. Revision history Revision number Revision date Description of changes 05/2012 * * * * * * * Updated content on page 1. Updated pin descriptions in Table 1. Updated pin connection drawing and Figure 2 to reflect horizontal bar for pin 1. Added Figure 3, Device Marking Diagram Updated Output Data Range row in Table 2. Updated Figure 4 to include pin names. Updated Bit 7 in Table 31 and 32 for emphasis. Changed description as highlighted in Red and bold text. 9 09/2012 * * * * * Added FXMS3110CDR1, Windows 8 option to ordering information. Table 1: Updated Pin 6, SDA, description. Table 2: added Sensor die-to-package row. Updated Table 5, Boot time from power row Max value from deleted, Typ value added, 1.7. Deleted section 4.1. Updated I2C sections 4.3.1 and 4.3.2 (replaced Pullup section). 9.1 10/2012 * Table 2: added Sensor die-to-package row. 02/2013 * Updated ordering table, deleted MAG3110FCR2 option. * Table title for Table 2 and Table 5: Updated VDD = 1.8 V to VDD = 2.4 V and added VDDIO = 1.8 V. * Updated second paragraph in Section 5.3.1 "The user offsets are automatically added by the MAG3110... " to "The user offsets are automatically subtracted by the MAG3110... " 8 9.2 MAG3110 Sensors Freescale Semiconductor, Inc. 29 How to Reach Us: Information in this document is provided solely to enable system and software Home Page: freescale.com implementers to use Freescale products. There are no express or implied copyright Web Support: freescale.com/support information in this document. licenses granted hereunder to design or fabricate any integrated circuits based on the Freescale reserves the right to make changes without further notice to any products herein. Freescale makes no warranty, representation, or guarantee regarding the suitability of its products for any particular purpose, nor does Freescale assume any liability arising out of the application or use of any product or circuit, and specifically disclaims any and all liability, including without limitation consequential or incidental damages. "Typical" parameters that may be provided in Freescale data sheets and/or specifications can and do vary in different applications, and actual performance may vary over time. All operating parameters, including "typicals," must be validated for each customer application by customer's technical experts. Freescale does not convey any license under its patent rights nor the rights of others. Freescale sells products pursuant to standard terms and conditions of sale, which can be found at the following address: freescale.com/SalesTermsandConditions. Freescale, the Freescale logo, AltiVec, C-5, CodeTest, CodeWarrior, ColdFire, C-Ware, Energy Efficient Solutions logo, Kinetis, mobileGT, PowerQUICC, Processor Expert, QorIQ, Qorivva, StarCore, Symphony, and VortiQa are trademarks of Freescale Semiconductor, Inc., Reg. U.S. Pat. & Tm. Off. Airfast, BeeKit, BeeStack, ColdFire+, CoreNet, Flexis, MagniV, MXC, Platform in a Package, QorIQ Qonverge, QUICC Engine, Ready Play, SafeAssure, SMARTMOS, TurboLink, Vybrid, and Xtrinsic are trademarks of Freescale Semiconductor, Inc. All other product or service names are the property of their respective owners. (c) 2013 Freescale Semiconductor, Inc. Document Number: MAG3110 Rev. 9.2 02/2013