2.25 V Voltage Variable Absorptive Attenuator, 42 dB
1.8 - 2.5 GHz
Rev. V3
MAAVSS0001
1
1
M/A-COM Technology Solutions Inc. (MACOM) and its affiliates reserve the right to make changes to the product(s) or information contained herein without notice.
Visit www.macom.com for additional data sheets and product information.
For further information and support please visit:
https://www.macom.com/support
1
Features
Single Positive Voltage Control, 0 to +2.25 Volts
42 dB Typical Attenuation Range at 2.4 GHz
Low DC Power Consumption
Lead-Free SOT-25 Package
100% Matte Tin Plating over Copper
Halogen-Free “Green” Mold Compound
260°C Reflow Compatible
RoHS* Compliant Version of AT-119
Description
M/A-COM’s MAAVSS0001 is a GaAs MMIC voltage
variable absorptive attenuator in a lead-free
SOT-25 surface mount plastic package. M/A-COM
fabricates the MAAVSS0001 with a proven
monolithic GaAs 0.5 micron gate process that
features full chip passivation for performance and
reliability.
Applications
The MAAVSS0001 is ideally suited for applications
that require fine tuning, linear attenuation with
voltage, and very low power consumption.
Typical applications for the MAAVSS0001 include
automatic gain control circuits in satellite radio
receivers and other wireless receivers.
Functional Schematic
5
VCC
4
VCTL
1
RF
3
RF
2
GND
100pF 100pF
5
VCC
4
VCTL
1
RF
3
RF
2
GND
100pF 100pF
Pin Function Description
1 RF RF (input / output)
2 GND Ground
3 RF RF (input / output)
4 VCTL Control Voltage
5 VCC DC Supply Voltage
Pin Configuration
Ordering Information1
Part Number Package
MAAVSS0001 Bulk Packaging
MAAVSS0001TR-3000 3000 piece reel
MAAVSS0001SMB Sample Test Board
(Includes 5 Samples)
1. Reference Application Note M513 for reel size information.
Absolute Maximum Ratings 2,3
@ TA = +25°C (unless otherwise specified)
Parameter Absolute Maximum
Input Power +21 dBm
Supply Voltage VCC -1 V VCC +8 V
Control Voltage VCTL -1 V VCTL VCC +0.5 V
Operating Temperature -40°C to +85°C
Storage Temperature -65°C to +150°C
* Restrictions on Hazardous Substances, European Union Directive 2002/95/EC.
2. Exceeding any one or combination of these limits may cause
permanent damage to this device.
3. M/A-COM does not recommend sustained operation near
these survivability limits.