4
G6AG6A
Double-winding Latching, Low-sensitivity DPDT Relays
Double-winding Latching, Low-sensitivity 4PDT Relays
Note: 1. The rated current and coil resistance are measured at a coil temperature of 23°C with a tolerance of ±10%.
2. Operating characteristics are measured at a coil temperature of 23°C.
■Contact Ratings
Note P level: l60 = 0.1 x 10–6/operation
Rated voltage 3 VDC 4.5 VDC 5 VDC 6 VDC 9 VDC 12 VDC 24 VDC 48 VDC
Rated current 120 mA 79.9 mA 72.5 mA 60 mA 40 mA 30 mA 15 mA 7.5 mA
Coil resistance 25
W
56.3
W
69
W
100
W
225
W
400
W
1,600
W
6,400
W
Coil inductance
(H) (ref. value) Set Armature OFF 0.015 0.04 0.05 0.07 0.16 0.28 1.1 4
Armature ON 0.01 0.025 0.035 0.05 0.12 0.2 0.75 2.9
Reset Armature OFF 0.01 0.025 0.035 0.05 0.12 0.2 0.75 2.9
Armature ON 0.015 0.04 0.05 0.07 0.16 0.28 1.1 4
Must operate voltage 70% max. of rated voltage
Must release voltage 70% max. of rated voltage
Max. voltage 150% of rated voltage at 23°C
Power consumption Approx. 360 mW
Rated voltage 3 VDC 4.5 VDC 5 VDC 6 VDC 9 VDC 12 VDC 24 VDC 48 VDC
Rated current 120 mA 79.9 mA 72.5 mA 60 mA 40 mA 30 mA 15 mA 7.5 mA
Coil resistance 25
W
56.3
W
69
W
100
W
225
W
400
W
1,600
W
6,400
W
Coil inductance
(H) (ref. value) Set Armature OFF 0.02 0.045 0.065 0.09 0.18 0.3 1.2 4.4
Armature ON 0.015 0.035 0.05 0.075 0.14 0.23 0.82 3.2
Reset Armature OFF 0.015 0.035 0.05 0.075 0.14 0.23 0.82 3.2
Armature ON 0.02 0.045 0.065 0.09 0.18 0.3 1.2 4.4
Must operate voltage 70% max. of rated voltage
Must release voltage 70% max. of rated voltage
Max. voltage 150% of rated voltage at 23°C
Power consumption Approx. 360 mW
Item G6A-234P-ST(40)-US/434P-ST(40)-US G6A-274P-ST(40)-US/474P-ST(40)-US
Load Resistive load
(cos
f
= 1) Inductive load
(cos
f
= 0.4; L/R = 7 ms) Resistive load
(cos
f
= 1) Inductive load
(cos
f
= 0.4; L/R = 7 ms)
Rated load 0.3 A at 125 VAC;
1 A at 30 VDC 0.2 A at 125 VAC;
0.5 A at 30 VDC 0.5 A at 125 VAC;
2 A at 30 VDC 0.3 A at 125 VAC;
1 A at 30 VDC
Contact material AgPd (Au-clad) Ag (Au-clad)
Rated carry current 3 A
Max. switching voltage 250 VAC, 220 VDC
Max. switching current 2 A 1 A 2 A 1 A
Max. switching power 125 VA, 60 W 62.5 VA, 30 W 125 VA, 60 W 62.5 VA, 30 W
Failure rate (reference value) 0.01 mA at 10 mVDC
Item G6AK-234P-ST(40)-US/G6AK-434P-ST(40)-US
G6AU-234P–ST-US/G6AU-434P-ST-US G6AK-274P-ST(40)-US/G6AK-474P-ST(40)-US
G6AU-274P-ST-US/G6AU-474P-ST-US
Load Resistive load
(cos
f
= 1) I nduct ive load
(cos
f
= 0.4; L/R = 7 ms ) Resistive load
(cos
f
= 1) Inductive load
(cos
f
= 0.4; L/R = 7 ms)
Rated load 0.3 A at 125 VAC;
1 A at 30 VDC 0.2 A at 125 VAC;
0.5 A at 30 VDC 0.5 A at 125 VAC;
2 A at 30 VDC 0.25 A at 125 VAC;
1 A at 30 VDC
Contact material AgPd (Au-clad) Ag (Au-clad)
Rated carry current 3 A 3 A
Max. switching voltage 250 VAC, 220 VDC 250 VAC, 220 VDC
Max. switching current 2 A 1 A 2 A 1 A
Max. switching power 125 VA, 60 W 62.5 VA, 30 W 125 VA, 60 W 62.5 VA, 30 W
Failure rate (reference value) 0.01 mA at 10 mVDC 0.01 mA at 10 mVDC