SPECIFICATION
MODEL ELN-60-12ELN-60-9 ELN-60-15 ELN-60-24 ELN-60-27 ELN-60-48
DC VOLTAGE
RATED CURRENT
CURRENT RANGE
RATED POWER
OUTPUT VOLTAGE ADJ. RANGE Note.7
CURRENT ADJ. RANGE Note.7
LINE REGULATION
LOAD REGULATION
SETUP, RISE TIME Note.6
HOLD UP TIME (Typ.)
VOLTAGE RANGE Note.4
FREQUENCY RANGE
EFFICIENCY (Typ.)
AC CURRENT (Typ.)
INPUT
INRUSH CURRENT (Typ.)
LEAKAGE CURRENT
WORKING TEMP.
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
MTBF
DIMENSIONOTHERS
NOTE
PACKING
OVER CURRENT
OVER VOLTAGE
12V
6 ~ 12V
5A
9V 15V
7.5 ~ 15V
24V
12 ~ 24V
48V
24 ~ 48V
5A 2.5A 2.3A
27V
13.5 ~ 27V
1.3A
0 ~ 5A0 ~ 5A 0 ~ 4A
4A
0 ~ 2.5A 0 ~ 2.3A 0 ~ 1.3A
60W45W 60W 60W 62.1W 62.5W
120mVp-p
10.8 ~ 13.2V
120mVp-p 150mVp-p
13.5 ~ 16.5V
150mVp-p
21.6 ~ 26.4V
200mVp-p
24.3 ~ 29.7V
250mVp-p
43.2 ~ 52.8V
±5.0%
-25% ~ 3%. Can be adjusted by internal potentiometer SVR2
±1.0%
±2.0%
500ms, 30ms / 230VAC 1500ms, 30ms / 115VAC at full load
90 ~ 264VAC 127 ~ 370VDC
47 ~ 63Hz
82% 85% 86% 87% 87% 88%
13.8 ~ 16V11 ~ 13.5V 17.5 ~ 21V 28 ~ 32V 31 ~ 37V 54 ~ 60V
1.2A/115VAC 0.7A/230VAC
COLD START 60A(twidth=600 s measured at 50% Ipeak) at 230VACμ
0.25mA / 240VAC
Protection type : Constant current limiting, recovers automatically after fault condition is removed
-20 ~ +60 (Refer to "Derating Curve")℃
20 ~ 90% RH non-condensing
-40 ~ +80 , 10 ~ 95% RH℃
±℃ ℃0.03%/ (0 ~ 50 )
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
603Khrs min. MIL-HDBK-217F (25 )℃
181*61.5*35mm (L*W*H)
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.℃
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. Derating may be needed under low input voltage. Please check the static characteristics for more details.
5. The power supply is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the
complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again.
6. Length of set up time is measured at first cold start. Turning ON/OFF the power supply may lead to increase of the set up time.
7. Output voltage can be adjusted through the SVR1 on the PCB ; limit of output constant current level can be adjusted through the SVR2 on the PCB.
8. Constant current operation region is within the specified output voltage range above. This is the suitable operation region for LED related applications.
9. The unit might not be suitable for lighting applications in EU countries. Please check with your local authorities for the possible use of the unit.
0.4Kg; 24pcs/11Kg/0.75CUFT
60W Single Output Class 2 Switching Power Supply
Universal AC input / Full range
Protections: Short circuit / Over current / Over voltage
Cooling by free air convection
Built-in constant current limiting circuit with adjustable OCP level
Optional dimming function : 1~10VDC (D type) or PWM (P type) controlled
Fully isolated plastic case with IP64 level
ⅡClass power unit, no FG
Class 2 power unit
Pass LPS
Suitable for LED lighting and moving sign applications (Note.9)
100% full load burn-in test
Low cost, high reliability
2 years warranty
â– Features :
ELN-60 series
RIPPLE & NOISE (max.) Note.2
VOLTAGE TOLERANCE Note.3
ENVIRONMENT
SAFETY &
EMC
PROTECTION
SAFETY STANDARDS
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
I/P-O/P:3KVAC
I/P-O/P:>100M Ohms / 500VDC / 25 / 70% RH℃
Compliance to EN55022 (CISPR22) Class B, EN61000-3-2 Class A, EN61000-3-3
Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024, light industry level, criteria A
8.7 ~ 10.5V
UL1310, CAN/CSA C22.2 No. 223-M91(except for 48V), IP64 approved ; design refer to TUV EN60950-1
95 ~ 110%
Protection type : Shut down o/p voltage, re-power on to recover
50ms/230VAC 16ms/115VAC at full load
DIMMING CONTROL (OPTIONAL)
1 ~ 10VDC or PWM signal : 100Hz ~ 3KHz
FUNCTION
File Name:ELN-60-SPEC 2015-05-28
LED OPERATION VOLTAGE
Note.8
3 ~ 9V
Can be adjusted by internal potentiometer SVR1
IP64
( for 48V only) ( except for 48V )
LPS
EMC IMMUNITY
EMC EMISSION
MAX. No. of PSUs on 16A
CIRCUIT BREAKER 3 units (circuit breaker of type B) / 5 units (circuit breaker of type C) at 230VAC