Rev. 02.22.11_81
HPS3000 Series
1 of 8
Embedded Power for
Business-Critical Continuity
HPS3000 Series
3000 Watts
Special Features
•3000Woutputpower
•40W/cu-in
•Optionalcustomerprovidedair
•1Ux3Uformfactor
•N+1Redundant
•Hot-swap
•InternalOR-ing
•5Vhousekeeping
•Highefciency89%@200Vac,
100%load
•Variablespeed“smartfans”
•Twoyearwarranty
Distributed Power Bulk Front-End
Single Output
ElectricalSpecications
Safety
Input
Inputrange(operating): 180-264Vac
90-140Vac
Inputrange(nominal): 200Vac
110Vac
InputthroughCardEdgeConnection
on same end as DC output
Frequency: 47to63Hz
Inputfusing: Internal25Afuses Bothlinesfused
Inrushcurrent: ≤40Apeak Eitherhotorcoldstart
Powerfactor: 0.97typical MeetsEN61000-3-2
Harmonics: MeetsIEC1000-3-2
requirements
@50%load
Inputcurrent: 19Amaxinputcurrent
Holduptime: 10msminimum Atfullratedload
Leakagecurrent: 1.4mA At240Vac
Powerlinetransient: MOVdirectlyafterthefuse
• UL/cUL 60950
• CSA 60950
• China CCC
• Nemko TUV
• CB Report
• CSA 22.2 60950
Compliance
•POEIsolation
•EMIClassB-EN55022,Level“A”
@230Vac
•EN61000Immunity
Rev. 02.22.11_81
HPS3000 Series
2 of 8
Embedded Power for
Business-Critical Continuity
Output
Outputrating 48V@62.0A
5Vsb@3.0A
180-264Vac
48V@29.4A
5V@3A
90-140Vac
Set point 48V Programmable96-117%throughI2C serial bus
Totalregulationrange 48V±5%
5Vsb±4%
Line/load/transientwhenmeasuredatoutputconnection
Ratedload 3000Wmaximum@200VacInput
1500Wmaximum@110VacInput
Noderatingoveroperatingtemprange
Minimum load 48V@0.0A
5Vsb@0.0A
Nolossofregulation
Outputnoise 480mVmaxP-P
100mVmaxP-P
48Voutput
5Vsboutput
Measuredwitha0.1µFCeramicand10µFTantalumcapacitoronany
input
Outputvoltageovershoot ±5%maximum NominalVoltageSetting
Transientresponse 5%maximumdeviation 50%loadstep@1A/us
Steploadvalidbetween10%to100%ofoutputrating.
Maxunitsinparallel Upto4 Totalpowerin1U19”rackis12KW
Shortcircuitprotection 120%-130%ofratedoutput Outputtoreturn
Outputisolation PerPOEspecs >2000Vac
Forcedloadsharing Within10%ofallsharedoutputs Digitalsharingcontrol
Overcurrentprotection(OCP) 120%to130%
110%to140%
48Voutput
5Vsboutput
Overvoltageprotection(OVP) 110%to133%
110%to125%
48Voutput
5Vsboutput
Overtemperatureprotection 10-15degCabovesafe
operatingarea
BothPFCandoutputconvertermonitored
5Vsbwilloperateunderovertemperaturecondition.
Builtinhysteresis
230Vac Efficiency
10.00
20.00
30.00
40.00
50.00
60.00
70.00
80.00
90.00
100.00
10 20 30 40 50 60 70 80 90 100
% of Total Output Power
230VacEfciency
EnvironmentalSpecications
Vibration/Shock: Non-operational5GSinesweepfrom5Hzto500Hz,dwellingatresonantfrequenciesfor1houreach
Operatingtemperature: -10°to+40°C
StorageTemperature: -40°to+85°C
Cooling ExternalfanswithFanFailandFanSpeedcontrol
OperatingRelativeHumidity: 5%to95%non-condensing
StorageRelativeHumidity: 5%to95%non-condensing
OperatingAltitude Upto10,000feetabovesealevel
StorageAltitude: Upto30,000feetabovesealevel
RoHSCompliant: Yes
Embedded Power for
Business-Critical Continuity
Embedded Power for
Business-Critical Continuity
Rev. 02.22.11_81
HPS3000 Series
3 of 8
(Allunitsinmm)
ModuleInformation
Embedded Power for
Business-Critical Continuity
Embedded Power for
Business-Critical Continuity
PinAssignments
Bottom Top
Rev. 02.22.11_81
HPS3000 Series
4 of 8
Pin
64 ACLINE
63 ACLINE
62 n.c.
61 ACNEUTRAL
60 ACNEUTRAL
59 n.c.
58 n.c.
57 n.c.
56 +48Vdcout
55 +48Vdcout
54 +48Vdcout
53 +48Vdcout
52 +48Vdcout
51 +48Vdcout
50 +48Vdcout
49 +48VdcRTN
48 +48VdcRTN
47 +48VdcRTN
46 +48VdcRTN
45 +48VdcRTN
44 +48VdcRTN
43 +48VdcRTN
42 n.c.
41 SYS_GND
40 Reserved
39 ACOK#
38 SMBUS_ALERT_OUT
37 SCL
36 A2
35 PSKILL
34 A1
33 A0
Pin
1ACLINE
2 ACLINE
3n.c.
4ACNEUTRAL
5 ACNEUTRAL
6n.c.
7n.c.
8n.c.
9+48Vdcout
10 +48Vdcout
11 +48Vdcout
12 +48Vdcout
13 +48Vdcout
14 +48Vdcout
15 +48Vdcout
16 +48VdcRTN
17 +48VdcRTN
18 +48VdcRTN
19 +48VdcRTN
20 +48VdcRTN
21 +48VdcRTN
22 +48VdcRTN
23 n.c.
24 V_STBY
25 Reserved
26 PRESENT#
27 DCOK/PWOK#
28 SDA
29 HVCC
30 PSON#
31 #ALERT
32 ISHARE
Embedded Power for
Business-Critical Continuity
TPWOK_Off_
AC Input
Main Vout
Timing Diagram
TAC_On_Delay
TVout_Holdup
TPWOK_On
AC Input
ON / OFF Cycle
AC_OK
PS_ON
3.3 V Vout
PWOK
PSON
ON / OFF
Cycle
Tsb_On
TSB_Vout
TPWOK_Delay
TPWOK_Off_
T
PWOK_Off_
TPWOK_On
TPWOK_Off_
TPWOK_On
TACOK_Delay
TPSON_On_Delay
TPSON_PWOK
TPWOK_Off
AC On
AC On
Rev. 02.22.11_81
HPS3000 Series
5 of 8
Rev. 02.22.11_81
HPS3000 Series
6 of 8
Embedded Power for
Business-Critical Continuity
TimingSignalDenitions
TurnON/OFFTiming
Item Description Min Max Units
Tvout_rise 48VOutputrisetime 5 300 msec
Tsb_on_delay DelayfromACbeingappliedto5Vsbbeingwithinregulation. 1500 msec
Tac_on_delay DelayfromACbeingappliedtoalloutputvoltagesbeingwithin
regulation.
2000 msec
Tvout_holdup Timealloutputvoltages,including5Vsb,staywithinregulation
afterlossofAC.
10 msec
Tpwok_holdup DelayfromlossofACtode-assertionofPWOK 5 msec
Tpson_on_delay DelayfromPSON#activetooutputvoltageswithinregulation
limits.
5 400 msec
Tpson_pwok DelayfromPSON#de-activetoPWOKbeingde-asserted. 50 msec
Tacok_delay DelayfromlossofACinputtode-assertionofACOK#. 10 msec
Tpwok_on DelayfromoutputvoltageswithinregulationlimitstoPWOK
asserted at turn on.
100 1000 msec
Tpwok_off DelayfromPWOKde-assertedto48Vdroppingoutofregulation
limits.
1 1000 msec
Tpwok_low DurationofPWOKbeinginthede-assertedstateduringanoff/on
cycleusingACorthePSON#signal.
100 msec
Tsb_vout Delayfrom5Vsbbeinginregulationto48Vbeingin
regulationatACturnon.
50 2000 msec
PSON#
ThePSON#signalisrequiredtoremotelyturnon/offthepowersupply.PSON#isanactivelowsignal
thatturnsonthe48Vpowerrail.Whenthissignalisnotpulledlowbythesystem,orleftopen,the
48Voutputturnsoff.The5Vsboutputremainson.Thissignalispulledtoastandbyvoltagebya
pull-upresistorinternaltothepowersupply.Thepowersupplyfan(s)shalloperateatthelowestspeed.
PSON#SignalCharacteristic
SignalType Acceptsanopencollector/draininputfrom
thesystem.Pulled-uptothe5Vsblocatedin
power supply.
PSON#=Low ON
PSON#=Open OFF
MIN MAX
Logiclevellow(powersupplyON) 0V 0.4V
Logiclevelhigh(powersupplyOFF) 2.40V 3.40V
Sourcecurrent,Vpson=low -- 4mA
Powerupdelay:Tpson_on_delay 5msec 400msec
SignalsandControls-AllModels
Rev. 02.22.11_81
HPS3000 Series
7 of 8
Embedded Power for
Business-Critical Continuity
PWOK#(PowerGood)
PWOK#isapowergoodsignalandwillbepulledLOWbythepowersupplytoindicatethatboththe
outputsareabovetheregulationlimitsofthepowersupply.Whenanyoutputvoltagefallsbelow
regulationlimitsorwhenACpowerhasbeenremovedforatimesufcientlylongsothatpowersupply
operationisnolongerguaranteed,PWOKwillbede-assertedtoaHIGHstate.ThestartofthePWOK#
delaytimeshallbeinhibitedaslongasthe48Voutputisincurrentlimitorthe5Vsboutputisbelow
theregulationlimit.
PowerSupplyPresentIndicator(PRESENT#)
ThePRESENT#signalisprimarilyusedtoprovideamechanismbywhichthehostsystemcansensethe
numberofpowersuppliesphysicallypresent(operationalornot).Thispinisconnectedtogroundinthe
power supply.
ACINPUTPresentIndicator(ACOK#)
TheACOK#signalisusedtoindicatepresenceofACinputtothepowersupply.Thissignalshallbe
connectedto5Vsbthrougharesistoronthehostsystemside.Alogic“Low”levelonthissignalshall
indicateACinputtothepowersupplyispresent.ALogic“High”onthissignalshallindicatealossofAC
inputtothepowersupply.
Table12
ACOK#SignalCharacteristics
SignalType Pull-upto5Vsbthrougharesistorinthehost
system.
PRESENT#=Low Present
PRESENT#=High Notpresent
MIN MAX
Logiclevellowvoltage,Ising=4mA 0V 0.8V
Logiclevelhighvoltage,Isink=50µA 2.0V 4.80V
Sinkcurrent,PRESENT#=Low 4mA
Sourcecurrent,PRESENT#=High 50µA
PSON#SignalCharacteristic
SignalType Opencollector/drainoutputfrompower
supply.Pullupto5Vsbexternaltothepower
supply.
PWOK=High ON
PWOK=LOW OFF
MIN MAX
Logiclevellowvoltage,Isink=4mA 0V 0.8V
Logiclevelhighvoltage,Isource=200µA 2.0V 4.80V
Sinkcurrent,PWOK=low 4mA
Sourcecurrent,PWOK=high 2mA
PWOKdelay:Tpwokon 100msec 1000msec
PWOKriseandfalltime 100µsec
Powerdowndelay:Tpwokoff 1msec 1000msec
Rev. 02.22.11_81
HPS3000 Series
8 of 8
Embedded Power for
Business-Critical Continuity
LEDINDICATORS
TherewillbeagreenPOWERLED(PWR)toindicatethatACisappliedtothe
PSUandstandbyvoltageisavailablewhenblinking.ThissameLEDshouldgo
solidwhenthe48Voutputisenabledandoperational.
TherewillbeanAmberPowerSupplyFailLED(FAIL)toindicatethatthepower
supplyhasfailedandareplacementoftheunitisnecessary.Faultsincluding
UVP,OVP,OTP,orFanFailwhenPSON#isasserted“LogicLow”shallcausethe
amberLEDtoturnon.TheLEDcanbeturnedoffbyrecyclingPSON#signalor
byanACpowerinterruptionmorethan1second.TheLEDshallbeoffwhen
PSON#isnotasserted“LogicLow”.Refertotable13forconditionsofthe
LED’s:
MTBF
ThepowersupplyhasaminimumMTBFof300KhoursusingtheBellcore332,
issue6specication@25°Cand40°C,ambient,atfullload.Withthepower
supplyinstalledinasystemina25°Cambientenvironmentand
operatingatfullload,capacitorlifeshallbe10years,minimumforALL
electrolyticcapacitorscontainedwithinthispowersupply.Thepowersupply
shalldemonstrateaMTBFlevelof>500,000hours.
Quality Assurance
FullQAVtestingshallbeconductedinaccordancewithEmersonNetwork
PowerStandardswithreportsavailableuponrequest.
Warranty
EmersonNetworkPowershallwarrantthepowersupplytobefreeofdefects
inmaterialsandworkmanshipforaminimumperiodoftwoyearsfromthe
dateofshipment,whenoperatedwithinspecications.Thewarrantyshallbe
fullytransferabletotheendowneroftheequipmentpoweredbythesupply.
Table13
LEDIndicators
Power Supply Condition Power LED
(GREEN)
Fail LED
(AMBER)
NoACpowertoPSU OFF OFF
ACpresent/StandbyOutputOn Blinking OFF
Powersupply48VoutputONandOK ON OFF
Powersupplyfailure(includes
overvoltage,overtemperature)
OFF ON
Current limit ON Blinking
Model Number Main Output Main Output
Current Standby Output Standby Current
HPS3000-9 48Vdc 62.0A 5.0V 3.0A
OrderingInformation
Americas
5810VanAllenWay
Carlsbad,CA92008
USA
Telephone:+17609304600
Facsimile: +17609300698
Europe(UK)
WaterfrontBusinessPark
MerryHill,Dudley
WestMidlands,DY51LX
UnitedKingdom
Telephone:+44(0)1384842211
Facsimile: +44(0)1384843355
Asia(HK)
14/F,LuPlaza
2WingYipStreet
KwunTong,Kowloon
HongKong
Telephone:+85221763333
Facsimile: +85221763888
Forglobalcontact,visit:
www.Emerson.com/
EmbeddedPower
techsupport.embeddedpower@
emerson.com
Whileeveryprecautionhasbeentakentoensure
accuracyandcompletenessinthisliterature,Emerson
NetworkPowerassumesnoresponsibility,anddisclaims
allliabilityfordamagesresultingfromuseofthis
information or for any errors or omissions.
EmersonNetworkPowerandtheEmerson
NetworkPowerlogoaretrademarksandser-
vicemarksofEmersonElectricCo.
©2011EmersonElectricCo.
EmersonNetworkPower.com
EmbeddedComputing
Embedded Power
Monitoring
OutsidePlant
PowerSwitching&Controls
PrecisionCooling
Racks&IntegratedCabinets
Services
SurgeProtection
EmersonNetworkPower.
Thegloballeaderinenabling
business-critical continuity.
ACPower
Connectivity
DC Power