2
HPMD-7904 Electrical Specifications, ZO = 50Ω, TC[1] as indicated
+25°C[1,3] +85°C[1,2,3] –30°C[1,2,3]
Symbol Parameters Units Min Typ Max Min Typ Max Min Typ Max
fRX Receive Bandwidth MHz 1930.6 — 1989.4 1930.6 — 1989.4 1930.6 — 1989.4
S23 Rx Attenuation in Transmit Band dB 50 54 — 50 52 — 50 52 —
(1850.6 –1909.4 MHz)
S23 Rx Typical Insertion Loss in Receive Band dB — 2.2 3.5 — 2.2 3.8 — 2.2 3.8
(1935–1985MHz)
S23 Rx Insertion Loss at Edges of Receive dB — 3.0 3.5 — 3.0 3.8 — 3.0 4.5
Band (1930.6-1935 MHz and
1985-1989.4 MHZ)
∆ S23 Ripple in Receive Band dB — 1.5 — — 1.5 — — 2.0 —
S22 Rx Return Loss in Receive Band dB 8.0 10 — 8.0 10 — 8.0 10 —
fTX Transmit Bandwidth MHz 1850.6 — 1909.4 1850.6 — 1909.4 1850.6 — 1909.4
S31 Tx Attenuation in Receive Band dB 40 42 — 40 42 — 37 42 —
(1930.6 –1935 MHz)
S31 Tx Attenuation in Receive Band dB 40 42 — 40 42 — 40 42 —
(1935–1989.4 MHz)
S31 Tx Insertion Loss in Transmit Band dB — 1.8 3.0 — 1.8 3.5 — 1.8 3.5
(1855–1905 MHz)
S31 Tx Insertion Loss at Edges of dB — 2.5 3.0 — 3.0 3.8 — 3.0 3.6
Transmit Band (1850.6-1855 MHz
and 1905-1909.4 MHz)
∆ S31 Ripple in Transmit Band dB — 2.0 — — 3.0 — — 2.0 —
S11 Tx Return Loss in Transmit Band dB 8.0 10 — 8.0 10 — 8.0 10 —
S33 Ant Return Loss, Tx and Rx bands dB 8.0 — — — — — — — —
S21 Tx-Rx Isolation, 1850.6– 1909.4 MHz dB 50 54 — 50 54 — 50 54 —
(Transmit Band)
S21 Tx-Rx Isolation, 1930.6– 1935 MHz dB 40 42 — 40 42 — 38 42 —
(Receive Band)
S21 Tx-Rx Isolation, 1935– 1989.4 MHz dB 40 42 — 40 42 — 40 42 —
(Receive Band)
Absolute Maximum Ratings[4]
Parameter Unit Value
Operating temperature[1] °C -30 to +85
Storage temperature[1] °C -30 to +100
Notes:
1. TC is defined as case temperature, the temperature of the underside of the duplexer where it
makes contact with the circuit board.
2. Specifications are given at operating temperature limits and room temperature. To estimate
performance at some intermediate temperature, use linear interpolation.
3. Specifications are guaranteed over the given temperature range, with the input power to the Tx
port equal to +30 dBm (or lower) over all Tx frequencies. The application of input power levels in
excess of +30 dBm will not destroy the duplexer, but its performance may exceed the specification
limits given above.
4. Operation in excess of any one of these conditions may result in permanent damage to the device.