V600-D23P55 V600-D23P55 Electromagnetic Inductive RFID Data Carrier V600-D23P55 Ultra-Small 530 kHz Flush Mount Data Carrier for Use in Metal and Non-metal Applications Passive tag technology (no internal power source for communications) Operates at 530 kHz EEPROM memory 10-year data storage 256 Bytes memory capacity -40C to 150C storage temperature -25C to 85C operation temperature 100,000 read/write cycles at -20C to 85C 800,000 read/write cycles at -20C to 0C Durable LCP resin construction Up to 10 mm transmission distance (application dependent) Ultra small -- 8 mm diameter x 5 mm For metal/non-metal flush-mount applications Capable of virtually unlimited number of Read-Only cycles Ordering Information DATA CARRIER Item Description Data carrier Type Electromagnetic inductive Part number Memory EEPROM Construction Case: LCP resin; Fill: epoxy resin Enclosure rating IEC60529, IP67 Size 8 mm dia. x 5 mm V600-D23P55 256 Bytes Specifications GENERAL * The communications distance priority mode or communications time priority mode can be set on the serial interface ID controller or ID sensor unit via the communications mode DIP switches. * The communications distance priority mode is always used for parallel interface ID controllers. * These specifications are the certified performance when taking into consideration variations in ambient temperatures and products. 1 V600-D23P55 V600-D23P55 DATA CARRIER MEMORY Memory capacity Usable memory 254 Bytes; 00(H) - FD(H) Total memory 256 Bytes; FE(H) - FF(H) Data storage Memory life Data maintained after it is encoded; 10 years max. -20C to 85C (-4F to 185F) 100,000 times per address -20C to 60C (-4F to 140F) 300,000 times per address -20C to 25C (-4F to 77F) 400,000 times per address -20C to 0C (-4F to 32F) 800,000 times per address CHARACTERISTICS Vibration resistance-destruction 10 to 2000 Hz, 1.5 mm double amplitude and 150 m/s2 for 15 min 10 times each X, Y and Z directions Shock resistance-destruction 500 m/s2; 3 times each in X, Y and Z directions (18 times total) STORAGE CONDITIONS Ambient temperature -40C to 150C (-40F to 302F) (There should be no icing.) Heat shock resistance -10C to 150C (14F to 302F) in 30 minute cycles; 1000 cycles High temperature resistance 150C (302F) continuously for 1000 hours Ambient humidity 35% to 95% relative humidity (no condensation) Environment Do not apply excessive pressure, shock or corrosive gas which may deform the product OPERATION CONDITIONS Ambient temperature -25C to 85C (-13F to 185F) (There should be no icing.) Ambient humidity 35% to 95% relative humidity (no condensation) Environment Do not expose the product to corrosive gases such as hydrogen sulfide gas or organic solvents. Avoid exposure to direct sunlight Avoid any condition that could cause physical damage Installation MUTUAL INTERFERENCE Data carriers must be at least 50 mm apart. Data carrier Data carrier 50 mm min. 2 V600-D23P55 V600-D23P55 DATA CARRIER AND READ/WRITE HEAD INSTALLATION CONDITIONS FOR NON-METAL APPLICATIONS Steel Steel V600-D23P55 V600-D23P55 V600-H51/V600-H52 V600-HS51 Non-metal material Non-metal material V600-H11 Transmission Distance Specifications for Non-metal Applications Data carrier and read/write head transmission distances (with installation conditions) are provided in this table. Read/write head Installation V600-H52 Stationary V600-H51 V600-H11 Stationary Stationary Read distance Installation V600-HS51 and V600-HA51 Stationary Transmission distance (max. axial offset 2 mm) Transmission distance priority 0.5 to 9.0 mm Transmission time priority 0.5 to 8.5 mm Write distance Transmission distance priority 0.5 to 8.5 mm Transmission time priority 0.5 to 8.5 mm Read distance Transmission distance priority 0.5 to 9.5 mm Transmission time priority 0.5 to 8.0 mm Write distance Transmission distance priority 0.5 to 9.0 mm Transmission time priority 0.5 to 8.0 mm Read distance Transmission distance priority 0.5 to 10.0 mm Write distance Sensor and amplifier Controller mode Read distance Transmission time priority 0.5 to 7.5 mm Transmission distance priority 0.5 to 10.0 mm Transmission time priority 0.5 to 7.5 mm Controller mode Transmission distance (max. axial offset 2 mm) Transmission distance priority 0.5 to 6.5 mm Transmission time priority 0.5 to 6.0 mm Write distance Transmission distance priority 0.5 to 6.5 mm Transmission time priority 0.5 to 6.0 mm Irrelevant 0.5 to 7.0 mm V600-HS51 and V600-HAM91 Stationary Read distance Write distance Irrelevant 0.5 to 7.0 mm V600-HS61 and V600-HA51 Stationary Read distance Transmission distance priority 0.5 to 7.0 mm Transmission time priority 0.5 to 6.0 mm Transmission distance priority 0.5 to 7.0 mm Write distance Transmission time priority 0.5 to 6.0 mm Irrelevant 0.5 to 7.0 mm V600-HS61 and V600-HAM91 Stationary Read distance Write distance Irrelevant 0.5 to 7.0 mm V600-HS63 and V600-HA51 Stationary Read distance Transmission distance priority 0.5 to 9.5 mm V600-HS63 and V600-HAM91 Stationary Transmission time priority 0.5 to 7.5 mm Write distance Transmission distance priority 0.5 to 9.5 mm Transmission time priority 0.5 to 7.5 mm Read distance Irrelevant 0.5 to 10.0 mm Write distance Irrelevant 0.5 to 9.5 mm 3 V600-D23P55 V600-D23P55 DATA CARRIER AND READ/WRITE HEAD INSTALLATION CONDITIONS FOR METAL APPLICATIONS Steel Steel V600-D23P55 V600-D23P55 V600-H51/V600-H52 V600-HS51 Steel (SC or SS) Steel (SC or SS) V600-H11 Transmission Distance Specifications for Metal Applications Data Carrier and read/write head transmission distances (and installation conditions) are provided in this table. Read/write head Installation V600-H52 Stationary Read distance Write distance Sensor and amplifier Installation V600-HS51 and V600-HA51 Stationary Read distance Stationary V600-HS61 and V600-HA51 Stationary Stationary Transmission distance priority 0.5 to 3.0 mm Transmission time priority 0.5 to 3.0 mm Transmission distance priority 0.5 to 3.0 mm Transmission time priority 0.5 to 3.0 mm Controller mode Transmission distance (max. axial offset 2 mm) Transmission distance priority 0.5 to 1.5 mm 0.5 to 1.5 mm Transmission distance priority 0.5 to 1.5 mm Transmission time priority 0.5 to 1.5 mm Read distance Irrelevant 0.5 to 2.5 mm Write distance Irrelevant 0.5 to 2.5 mm Read distance Transmission distance priority 0.5 to 1.0 mm Transmission time priority 0.5 to 1.0 mm Transmission distance priority 0.5 to 1.0 mm Write distance V600-HS61 and V600-HAM91 Transmission distance (max. axial offset 2 mm) Transmission time priority Write distance V600-HS51 and V600-HAM91 Controller mode Transmission time priority 0.5 to 1.0 mm Read distance Irrelevant 0.5 to 1.5 mm Write distance Irrelevant 0.5 to 1.5 mm INSTALLATION IN SURROUNDING METALS Data carrier Metal casing Note: Keep the data carrier detection surface flush with (or slightly above) the height of the metal mounting area, so that no metal interferes with data detection. OMRON ELECTRONICS LLC OMRON CANADA, INC. One East Commerce Drive Schaumburg, IL 60173 885 Milner Avenue Scarborough, Ontario M1B 5V8 1-800-55-OMRON 416-286-6465 Cat. No. Q07BAD1 4 3/01/7.5M Specifications subject to change without notice. Printed in the U.S.A.