V600-D23P55 V600-D23P55
1
Ultra-Small 530 kHz Flush Mount Data
Carrier for Use in Metal and Non-metal
Applications
Passive tag technology (no internal power
source for communications)
Operates at 530 kHz
EEPROM memory
10-year data storage
256 Bytes memory capacity
-40°C to 150°C storage temperature
-25°C to 85°C operation temperature
100,000 read/write cycles at -20°C to 85°C
800,000 read/write cycles at -20°C to 0°C
Durable LCP resin construction
Up to 10 mm transmission distance (application
dependent)
Ultra small — 8 mm diameter x 5 mm
For metal/non-metal flush-mount applications
Capable of virtually unlimited number of
Read-Only cycles
Electromagnetic Inductive RFID Data Carrier V600-D23P55
Ordering Information
DATA CARRIER
Item Description Part number
Data carrier Type Electromagnetic inductive V600-D23P55
Memory EEPROM
256 Bytes
Construction Case: LCP resin; Fill: epoxy resin
Enclosure rating IEC60529, IP67
Size 8 mm dia. x 5 mm
Specifications
GENERAL
The communications distance priority mode or communications time priority mode can be set on the serial interface ID controller
or ID sensor unit via the communications mode DIP switches.
The communications distance priority mode is always used for parallel interface ID controllers.
These specifications are the certified performance when taking into consideration variations in ambient temperatures and products.
2
V600-D23P55 V600-D23P55
Usable memory 254 Bytes; 00(H) - FD(H)
Total memory 256 Bytes; FE(H) - FF(H)
Data storage Data maintained after it is encoded; 10 years max.
Memory life -20°C to 85°C (-4°F to 185°F) 100,000 times per address
-20°C to 60°C (-4°F to 140°F) 300,000 times per address
-20°C to 25°C (-4°F to 77°F) 400,000 times per address
-20°C to 0°C (-4°F to 32°F) 800,000 times per address
DATA CARRIER MEMORY
Vibration resistance-destruction 10 to 2000 Hz, 1.5 mm double amplitude and 150 m/s2 for 15 min
10 times each X, Y and Z directions
Shock resistance-destruction 500 m/s2; 3 times each in X, Y and Z directions (18 times total)
CHARACTERISTICS
Ambient temperature -40°C to 150°C (-40°F to 302°F) (There should be no icing.)
Heat shock resistance -10°C to 150°C (14°F to 302°F) in 30 minute cycles; 1000 cycles
High temperature resistance 150°C (302°F) continuously for 1000 hours
Ambient humidity 35% to 95% relative humidity (no condensation)
Environment Do not apply excessive pressure, shock or corrosive gas which may deform the product
STORAGE CONDITIONS
Ambient temperature -25°C to 85°C (-13°F to 185°F) (There should be no icing.)
Ambient humidity 35% to 95% relative humidity (no condensation)
Environment Do not expose the product to corrosive gases such as hydrogen sulfide gas or organic
solvents.
Avoid exposure to direct sunlight
Avoid any condition that could cause physical damage
OPERATION CONDITIONS
Installation
Memory
capacity
MUTUAL INTERFERENCE
Data carriers must be at least 50 mm apart.
50 mm min.
Data carrier Data carrier
V600-D23P55 V600-D23P55
3
DATA CARRIER AND READ/WRITE HEAD INSTALLATION CONDITIONS
FOR NON-METAL APPLICATIONS
Read/write head Installation Controller mode Transmission distance
(max. axial offset ±2 mm)
V600-H52 Stationary Read distance Transmission distance priority 0.5 to 9.0 mm
Transmission time priority 0.5 to 8.5 mm
Write distance Transmission distance priority 0.5 to 8.5 mm
Transmission time priority 0.5 to 8.5 mm
V600-H51 Stationary Read distance Transmission distance priority 0.5 to 9.5 mm
Transmission time priority 0.5 to 8.0 mm
Write distance Transmission distance priority 0.5 to 9.0 mm
Transmission time priority 0.5 to 8.0 mm
V600-H11 Stationary Read distance Transmission distance priority 0.5 to 10.0 mm
Transmission time priority 0.5 to 7.5 mm
Write distance Transmission distance priority 0.5 to 10.0 mm
Transmission time priority 0.5 to 7.5 mm
Sensor and Installation Controller mode Transmission distance
amplifier (max. axial offset ±2 mm)
Stationary Read distance Transmission distance priority 0.5 to 6.5 mm
Transmission time priority 0.5 to 6.0 mm
Write distance Transmission distance priority 0.5 to 6.5 mm
Transmission time priority 0.5 to 6.0 mm
Stationary Read distance Irrelevant 0.5 to 7.0 mm
Write distance Irrelevant 0.5 to 7.0 mm
Stationary Read distance Transmission distance priority 0.5 to 7.0 mm
Transmission time priority 0.5 to 6.0 mm
Write distance Transmission distance priority 0.5 to 7.0 mm
Transmission time priority 0.5 to 6.0 mm
Stationary Read distance Irrelevant 0.5 to 7.0 mm
Write distance Irrelevant 0.5 to 7.0 mm
Stationary Read distance Transmission distance priority 0.5 to 9.5 mm
Transmission time priority 0.5 to 7.5 mm
Write distance Transmission distance priority 0.5 to 9.5 mm
Transmission time priority 0.5 to 7.5 mm
Stationary Read distance Irrelevant 0.5 to 10.0 mm
Write distance Irrelevant 0.5 to 9.5 mm
Transmission Distance Specifications for Non-metal Applications
Data carrier and read/write head transmission distances (with installation conditions) are provided in this table.
Steel
V600-H51/V600-H52
V600-HS51 Non-metal material
V600-D23P55 Steel
V600-H11
V600-D23P55
Non-metal material
V600-HS51 and
V600-HA51
V600-HS51 and
V600-HAM91
V600-HS61 and
V600-HA51
V600-HS61 and
V600-HAM91
V600-HS63 and
V600-HA51
V600-HS63 and
V600-HAM91
4
V600-D23P55 V600-D23P55
Read/write head Installation Controller mode Transmission distance
(max. axial offset ±2 mm)
V600-H52 Stationary Read distance Transmission distance priority 0.5 to 3.0 mm
Transmission time prior ity 0.5 to 3.0 mm
Write distance Transmission distance priority 0.5 to 3.0 mm
Transmission time prior ity 0.5 to 3.0 mm
Sensor and Installation Controller mode Transmission distance
amplifier (max. axial offset ±2 mm)
Stationary Read distance Transmission distance priority 0.5 to 1.5 mm
Transmission time prior ity 0.5 to 1.5 mm
Write distance Transmission distance priority 0.5 to 1.5 mm
Transmission time prior ity 0.5 to 1.5 mm
Stationary Read distance Irrelevant 0.5 to 2.5 mm
Write distance Irrelevant 0.5 to 2.5 mm
Stationary Read distance Transmission distance priority 0.5 to 1.0 mm
Transmission time prior ity 0.5 to 1.0 mm
Write distance Transmission distance priority 0.5 to 1.0 mm
Transmission time prior ity 0.5 to 1.0 mm
Stationary Read distance Irrelevant 0.5 to 1.5 mm
Write distance Irrelevant 0.5 to 1.5 mm
Data Carrier and read/write head transmission distances (and installation conditions) are provided in this table.
INSTALLATION IN SURROUNDING METALS
Note: Keep the data carrier detection surface flush with (or
slightly above) the height of the metal mounting area,
so that no metal interferes with data detection.
Data carrier
Metal casing
OMRON ELECTRONICS LLC OMRON CANADA, INC.
One East Commerce Drive 885 Milner Avenue
Schaumburg, IL 60173 Scarborough, Ontario M1B 5V8
1-800-55-OMRON 416-286-6465
Cat. No. Q07BAD1 3/01/7.5M Specifications subject to change without notice. Printed in the U.S.A.
V600-HS51 and
V600-HA51
V600-HS61 and
V600-HAM91
V600-HS61 and
V600-HA51
V600-HS51 and
V600-HAM91
DATA CARRIER AND READ/WRITE HEAD INSTALLATION CONDITIONS
FOR METAL APPLICATIONS
Steel
V600-H51/V600-H52
V600-HS51 Steel (SC or SS)
V600-D23P55 Steel
V600-H11
V600-D23P55
Steel (SC or SS)
Transmission Distance Specifications for Metal Applications