SN54ALS652, SN54ALS653, SN54AS651, SN54AS652 SN74ALS651A, SN74ALS652A, SN74ALS653, SN74ALS654, SN74AS651, SN74AS652 OCTAL BUS TRANSCEIVERS AND REGISTERS WITH 3-STATE OUTPUTS SDAS066F - DECEMBER 1983 - REVISED OCTOBER 1996 D D D D Bus Transceivers/Registers Independent Registers and Enables for A and B Buses Multiplexed Real-Time and Stored Data Choice of True or Inverting Data Paths Choice of 3-State or Open-Collector Outputs to A Bus Package Options Include Plastic Small-Outline (DW) Packages, Ceramic Chip Carriers (FK), and Standard Plastic (NT) and Ceramic (JT) 300-mil DIPs DEVICE A OUTPUT B OUTPUT LOGIC SN74ALS651A, 'AS651 3 State 3 State Inverting SN54ALS652, SN74ALS652A, 'AS652 3 State 3 State True 'ALS653 Open Collector 3 State Inverting SN74ALS654 Open Collector 3 State True SN54ALS', SN54AS' . . . JT PACKAGE SN74ALS', SN74AS' . . . DW OR NT PACKAGE (TOP VIEW) CLKAB SAB OEAB A1 A2 A3 A4 A5 A6 A7 A8 GND 1 24 2 23 3 22 4 21 5 20 6 19 7 18 8 17 9 16 10 15 11 14 12 13 VCC CLKBA SBA OEBA B1 B2 B3 B4 B5 B6 B7 B8 SN54ALS', SN54AS' . . . FK PACKAGE (TOP VIEW) OEAB SAB CLKAB NC VCC CLKBA SAB D D description A1 5 4 3 2 1 28 27 26 25 OEBA A7 A8 GND NC B8 B7 B6 These devices consist of bus-transceiver circuits, 24 B1 A2 6 D-type flip-flops, and control circuitry arranged for 7 23 B2 A3 multiplexed transmission of data directly from the 8 22 NC NC data bus or from the internal storage registers. 21 B3 A4 9 Output-enable (OEAB and OEBA) inputs are 20 B4 A5 10 provided to control the transceiver functions. 19 B5 A6 11 Select-control (SAB and SBA) inputs are provided 12 13 14 15 16 17 18 to select real-time or stored data transfer. The circuitry used for select control eliminates the typical decoding glitch that occurs in a multiplexer during the transition between stored and real-time NC - No internal connection data. A low input level selects real-time data, and a high input level selects stored data. Figure 1 illustrates the four fundamental bus-management functions that can be performed with the octal bus transceivers and registers. Data on the A or B data bus, or both, can be stored in the internal D-type flip-flops by low-to-high transitions at the appropriate clock (CLKAB or CLKBA) terminals, regardless of the select- or output-control terminals. When SAB and SBA are in the real-time transfer mode, it is possible to store data without using the internal D-type flip-flops by simultaneously enabling OEAB and OEBA. In this configuration, each output reinforces its input. When all other data sources to the two sets of bus lines are at high impedance, each set of bus lines remains at its last state. Please be aware that an important notice concerning availability, standard warranty, and use in critical applications of Texas Instruments semiconductor products and disclaimers thereto appears at the end of this data sheet. Copyright 1996, Texas Instruments Incorporated PRODUCTION DATA information is current as of publication date. Products conform to specifications per the terms of Texas Instruments standard warranty. Production processing does not necessarily include testing of all parameters. POST OFFICE BOX 655303 * DALLAS, TEXAS 75265 1 SN54ALS652, SN54ALS653, SN54AS651, SN54AS652 SN74ALS651A, SN74ALS652A, SN74ALS653, SN74ALS654, SN74AS651, SN74AS652 OCTAL BUS TRANSCEIVERS AND REGISTERS WITH 3-STATE OUTPUTS SDAS066F - DECEMBER 1983 - REVISED OCTOBER 1996 description (continued) The -1 versions of the SN74ALS651A and SN74ALS652A are identical to the standard versions except that the recommended maximum IOL for the -1 versions is increased to 48 mA. There are no -1 versions of the SN54ALS652, SN54ALS653, SN74ALS653, and SN74ALS654. The SN54ALS' and SN54AS' families are characterized for operation over the full military temperature range of - 55C to 125C. The SN74ALS' and SN74AS' families are characterized for operation from 0C to 70C. 2 POST OFFICE BOX 655303 * DALLAS, TEXAS 75265 SN54ALS652, SN54ALS653, SN54AS651, SN54AS652 SN74ALS651A, SN74ALS652A, SN74ALS653, SN74ALS654, SN74AS651, SN74AS652 OCTAL BUS TRANSCEIVERS AND REGISTERS WITH 3-STATE OUTPUTS 3 21 OEAB OEBA L L 1 23 2 CLKAB CLKBA SAB X X X BUS B BUS A BUS A BUS B SDAS066F - DECEMBER 1983 - REVISED OCTOBER 1996 22 SBA L 3 21 OEAB OEBA H H 21 OEBA H X H 1 23 2 CLKAB CLKBA SAB X X X X X 2 SAB L 22 SBA X BUS B BUS A BUS A 3 OEAB X L L 23 CLKBA X REAL-TIME TRANSFER BUS A TO BUS B BUS B REAL-TIME TRANSFER BUS B TO BUS A 1 CLKAB X 22 3 21 1 23 2 22 SBA OEAB H OEBA L CLKAB CLKBA SAB SBA H or L H or L H H X X X STORAGE FROM A, B, OR A AND B TRANSFER STORED DATA TO A AND/OR B Pin numbers are for the DW, JT, and NT packages. Figure 1. Bus-Management Functions POST OFFICE BOX 655303 * DALLAS, TEXAS 75265 3 SN54ALS652, SN54ALS653, SN54AS651, SN54AS652 SN74ALS651A, SN74ALS652A, SN74ALS653, SN74ALS654, SN74AS651, SN74AS652 OCTAL BUS TRANSCEIVERS AND REGISTERS WITH 3-STATE OUTPUTS SDAS066F - DECEMBER 1983 - REVISED OCTOBER 1996 FUNCTION TABLES SN54ALS653, SN54AS651, SN74ALS651A, SN74ALS653, SN74AS651 DATA I/O INPUTS OPERATION OR FUNCTION OEAB OEBA CLKAB CLKBA SAB SBA A1- A8 B1- B8 L H H or L H or L X X Input Input Isolation L H X X Input Input Store A and B data X H H or L X Input Unspecified Store A, hold B H H X X X Input Output Store A in both registers L X H or L X Unspecified Input Hold A, store B L L X X X Output Input Store B in both registers L L X X X L Output Input Real-time B data to A bus L L X H or L X H Output Input Stored B data to A bus H H X X L X Input Output Real-time A data to B bus H H H or L X H X Input Output Stored A data to B bus H L H or L H or L H H Output Output Stored A data to B bus and stored B data to A bus The data output functions may be enabled or disabled by a variety of level combinations at OEAB or OEBA. Data input functions are always enabled; i.e., data at the bus terminals is stored on every low-to-high transition on the clock inputs. Select control = L; clocks can occur simultaneously. Select control = H; clocks must be staggered to load both registers. SN54ALS652, SN54AS652, SN74ALS652A, SN74ALS654, SN74AS652 DATA I/O INPUTS OPERATION OR FUNCTION OEAB OEBA CLKAB CLKBA SAB SBA A1- A8 B1- B8 L H H or L H or L X X Input Input Isolation Input Unspecified Store A and B data Store A in both registers L H X X Input X H H or L X Input H H X X X X H or L X Input Hold A, store B L L X X X Input Unspecified Output L Output Input Store B in both registers L L X X X L Output Input Real-time B data to A bus L L X H or L X H Output Input Stored B data to A bus H H X X L X Input Output Real-time A data to B bus H H H or L X H X Input Output Stored A data to B bus Output Stored A data to B bus and stored B data to A bus H L H or L H or L H H Output Store A, hold B The data output functions may be enabled or disabled by a variety of level combinations at OEAB or OEBA. Data input functions are always enabled; i.e., data at the bus terminals is stored on every low-to-high transition on the clock inputs. Select control = L; clocks can occur simultaneously. Select control = H; clocks must be staggered to load both registers. 4 POST OFFICE BOX 655303 * DALLAS, TEXAS 75265 SN54ALS652, SN54ALS653, SN54AS651, SN54AS652 SN74ALS651A, SN74ALS652A, SN74ALS653, SN74ALS654, SN74AS651, SN74AS652 OCTAL BUS TRANSCEIVERS AND REGISTERS WITH 3-STATE OUTPUTS SDAS066F - DECEMBER 1983 - REVISED OCTOBER 1996 logic symbols SN54AS651, SN74ALS651A, SN74AS651 OEBA OEAB CLKBA SBA CLKAB SAB A1 21 3 23 22 1 EN1 [BA] OEBA EN2 [AB] OEAB 2 C6 G7 4 1 A4 A5 A6 A7 A8 SBA CLKAB SAB 5 1 20 4D B1 A1 5 1 7 1 A3 CLKBA C4 G5 6D A2 SN54ALS652, SN54AS652, SN74ALS652A, SN74AS652 1 21 3 23 22 1 OEAB C6 G7 4 1 7 6 18 7 17 8 16 9 15 10 14 11 13 A2 B3 A3 B4 A4 B5 A5 B6 A6 B7 A7 B8 A8 CLKBA SBA CLKAB SAB A1 23 22 1 OEBA EN2 [AB] OEAB 4 1 A4 A5 A6 A7 A8 SAB 5 4D 20 B1 A1 5 1 7 1 A3 SBA CLKAB 1 6D A2 CLKBA C4 G5 C6 G7 1 20 B1 1 2 7 5 19 6 18 7 17 8 16 9 15 10 14 11 13 B2 B3 B4 B5 B6 B7 B8 SN74ALS654 EN1 [BA] 2 4D 5 1 7 1 B2 5 1 2 19 3 C4 G5 6D 5 21 EN2 [AB] 2 SN54ALS653, SN74ALS653 OEBA EN1 [BA] 21 3 23 22 1 EN1 [BA] EN2 [AB] C4 G5 2 C6 G7 4 1 1 7 1 19 6 18 7 17 8 16 9 15 10 14 11 13 B2 A2 B3 A3 B4 A4 B5 A5 B6 A6 B7 B8 A7 A8 4D 20 B1 5 1 6D 2 7 5 5 1 2 7 5 19 6 18 7 17 8 16 9 15 10 14 11 13 B2 B3 B4 B5 B6 B7 B8 These symbols are in accordance with ANSI/IEEE Std 91-1984 and IEC Publication 617-12. Pin numbers shown are for the DW, JT, and NT packages. POST OFFICE BOX 655303 * DALLAS, TEXAS 75265 5 SN54ALS652, SN54ALS653, SN54AS651, SN54AS652 SN74ALS651A, SN74ALS652A, SN74ALS653, SN74ALS654, SN74AS651, SN74AS652 OCTAL BUS TRANSCEIVERS AND REGISTERS WITH 3-STATE OUTPUTS SDAS066F - DECEMBER 1983 - REVISED OCTOBER 1996 logic diagrams (positive logic) OEBA OEAB CLKBA SBA CLKAB SAB 21 SN54ALS653, SN54AS651, SN74ALS651A, SN74ALS653, SN74AS651 3 23 22 1 2 One of Eight Channels 1D C1 A1 4 20 1D B1 C1 To Seven Other Channels OEBA OEAB CLKBA SBA CLKAB SAB 21 3 SN54ALS652, SN54AS652, SN74ALS652A, SN74ALS654, SN74AS652 23 22 1 2 One of Eight Channels 1D C1 A1 4 20 1D C1 To Seven Other Channels Pin numbers shown are for the DW, JT, and NT packages. 6 POST OFFICE BOX 655303 * DALLAS, TEXAS 75265 B1 SN54ALS652, SN54ALS653, SN54AS651, SN54AS652 SN74ALS651A, SN74ALS652A, SN74ALS653, SN74ALS654, SN74AS651, SN74AS652 OCTAL BUS TRANSCEIVERS AND REGISTERS WITH 3-STATE OUTPUTS SDAS066F - DECEMBER 1983 - REVISED OCTOBER 1996 absolute maximum ratings over operating free-air temperature range (unless otherwise noted) Supply voltage, VCC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 V Input voltage, VI: Control inputs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 V I / O ports . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5.5 V Operating free-air temperature range, TA: SN54ALS652 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . - 55C to 125C SN74ALS651A, SN74ALS652A . . . . . . . . . . . . . . . . . 0C to 70C Storage temperature range, Tstg . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . - 65C to 150C Stresses beyond those listed under "absolute maximum ratings" may cause permanent damage to the device. These are stress ratings only, and functional operation of the device at these or any other conditions beyond those indicated under "recommended operating conditions" is not implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability. recommended operating conditions SN74ALS651A VCC VIH Supply voltage VIL IOH Low-level input voltage IOL Low level output current Low-level fclock Clock frequency High-level input voltage MIN NOM MAX 4.5 5 5.5 2 UNIT V V High-level output current 0.8 V - 15 mA 24 48 0 CLKBA or CLKAB high 12.5 CLKBA or CLKAB low 12.5 40 mA MHz tw Pulse duration tsu th Setup time before CLKAB or CLKBA A or B 10 ns Hold time after CLKAB or CLKBA A or B 0 ns TA Operating free-air temperature Applies only to the SN74ALS651A-1 and only if VCC is maintained between 4.75 V and 5.25 V ns 0 70 C recommended operating conditions SN54ALS652 VCC VIH Supply voltage VIL IOH Low-level input voltage IOL Low level output current Low-level fclock Clock frequency tw Pulse duration tsu th Setup time before CLKAB or CLKBA Hold time after CLKAB or CLKBA High-level input voltage SN74ALS652A MIN NOM MAX MIN NOM MAX 4.5 5 5.5 4.5 5 5.5 2 High-level output current 2 0.7 0.8 V - 12 - 15 mA 12 24 35 0 CLKBA or CLKAB high 14.5 12.5 CLKBA or CLKAB low 14.5 12.5 A or B 15 10 A or B 5 0 TA Operating free-air temperature - 55 Applies only to the SN74ALS652A-1 and only if VCC is maintained between 4.75 V and 5.25 V POST OFFICE BOX 655303 * DALLAS, TEXAS 75265 V V 48 0 UNIT 125 0 40 mA MHz ns ns ns 70 C 7 SN54ALS652, SN54ALS653, SN54AS651, SN54AS652 SN74ALS651A, SN74ALS652A, SN74ALS653, SN74ALS654, SN74AS651, SN74AS652 OCTAL BUS TRANSCEIVERS AND REGISTERS WITH 3-STATE OUTPUTS SDAS066F - DECEMBER 1983 - REVISED OCTOBER 1996 electrical characteristics over recommended operating free-air temperature range (unless otherwise noted) PARAMETER VIK SN74ALS651A TYP MAX MIN VCC = 4.5 V, VCC = 4.5 V to 5.5 V, II = - 18 mA IOH = - 0.4 mA 5V VCC = 4 4.5 IOH = - 3 mA IOH = - 15 mA VCC = 4 4.5 5V IOL = 12 mA IOL = 24 mA 0.25 0.4 0.35 0.5 VCC = 4.75 V, VCC = 5.5 V, IOL = 48 mA (-1 versions) VI = 7 V 0.35 0.5 Control inputs A or B ports VCC = 5.5 V, VI = 5.5 V VCC = 5.5 55V V, VI = 2 2.7 7V VCC = 5.5 55V V, VI = 0 0.4 4V VCC = 5.5 V, VO = 2.25 V VOH VOL II TEST CONDITIONS - 1.2 VCC - 2 2.4 A or B ports 2 0.1 0.1 20 20 Control inputs IIL IO ICC A or B ports V V 3.2 Control inputs IIH UNIT V mA A A - 0.2 VCC = 5.5 V - 0.2 - 30 - 112 Outputs high 42 68 Outputs low 52 82 Outputs disabled 52 82 mA mA mA All typical values are at VCC = 5 V, TA = 25C. For I/O ports, the parameters IIH and IIL include the off-state output current. The output conditions have been chosen to produce a current that closely approximates one-half of the true short-circuit output current, IOS. 8 POST OFFICE BOX 655303 * DALLAS, TEXAS 75265 SN54ALS652, SN54ALS653, SN54AS651, SN54AS652 SN74ALS651A, SN74ALS652A, SN74ALS653, SN74ALS654, SN74AS651, SN74AS652 OCTAL BUS TRANSCEIVERS AND REGISTERS WITH 3-STATE OUTPUTS SDAS066F - DECEMBER 1983 - REVISED OCTOBER 1996 electrical characteristics over recommended operating free-air temperature range (unless otherwise noted) PARAMETER VIK VOH VCC = 4.5 V, VCC = 4.5 V to 5.5 V, II = - 18 mA IOH = - 0.4 mA VCC = 4.5 V IOH = - 3 mA IOH = - 12 mA VCC = 4 4.5 5V VOL MIN A or B ports VCC = 5.5 V, VI = 7 V VI = 5.5 V 3.2 VCC = 5.5 55V V, VI = 2 2.7 7V 55V VCC = 5.5 V, 4V VI = 0 0.4 IO VCC = 5.5 V, VO = 2.25 V ICC VCC = 5.5 V A or B ports UNIT V V 2 0.25 Control inputs IIL 3.2 2 Control inputs A or B ports - 1.2 VCC - 2 2.4 0.4 IOL = 24 mA IOL = 48 mA (-1 versions) Control inputs IIH SN74ALS652A TYP MAX MIN - 1.2 VCC - 2 2.4 IOH = - 15 mA IOL = 12 mA VCC = 4.75 V, VCC = 5.5 V, II SN54ALS652 TYP MAX TEST CONDITIONS - 20 0.25 0.4 0.35 0.5 0.35 0.5 0.1 0.1 0.1 0.1 20 20 20 20 - 0.2 - 0.2 - 0.2 - 0.2 - 112 - 30 - 112 Outputs high 47 76 47 76 Outputs low 55 88 55 88 Outputs disabled 55 88 55 88 V mA A A mA mA mA All typical values are at VCC = 5 V, TA = 25C. For I/O ports, the parameters IIH and IIL include the off-state output current. The output conditions have been chosen to produce a current that closely approximates one-half of the true short-circuit output current, IOS. POST OFFICE BOX 655303 * DALLAS, TEXAS 75265 9 SN54ALS652, SN54ALS653, SN54AS651, SN54AS652 SN74ALS651A, SN74ALS652A, SN74ALS653, SN74ALS654, SN74AS651, SN74AS652 OCTAL BUS TRANSCEIVERS AND REGISTERS WITH 3-STATE OUTPUTS SDAS066F - DECEMBER 1983 - REVISED OCTOBER 1996 switching characteristics (see Figure 2) PARAMETER FROM (INPUT) TO (OUTPUT) VCC = 4.5 V to 5.5 V, CL = 50 pF, R1 = 500 , R2 = 500 , TA = MIN to MAX UNIT SN74ALS651A MIN fmax tPLH tPHL tPLH tPHL tPLH tPHL tPLH tPHL tPZH tPZL tPHZ tPLZ tPZH tPZL tPHZ CLKBA or CLKAB A or B A or B B or A SBA or SAB (with A or B high) A or B SBA or SAB (with A or B low) A or B OEBA A OEBA A OEAB B POST OFFICE BOX 655303 * DALLAS, TEXAS 75265 MHz 8 32 5 17 2 18 2 10 8 38 6 21 8 25 7 21 3 20 5 18 2 9 3 12 3 22 6 21 2 OEAB B tPLZ 2 For conditions shown as MIN or MAX, use the appropriate value specified under recommended operating conditions. These parameters are measured with the internal output state of the storage register opposite that of the bus input. 10 MAX 40 12 14 ns ns ns ns ns ns ns ns SN54ALS652, SN54ALS653, SN54AS651, SN54AS652 SN74ALS651A, SN74ALS652A, SN74ALS653, SN74ALS654, SN74AS651, SN74AS652 OCTAL BUS TRANSCEIVERS AND REGISTERS WITH 3-STATE OUTPUTS SDAS066F - DECEMBER 1983 - REVISED OCTOBER 1996 switching characteristics (see Figure 2) PARAMETER FROM (INPUT) TO (OUTPUT) VCC = 4.5 V to 5.5 V, CL = 50 pF, R1 = 500 , R2 = 500 , TA = MIN to MAX SN54ALS652 MIN fmax tPLH MAX 35 UNIT SN74ALS652A MIN MAX 40 MHz 10 35 8 30 5 20 5 17 5 20 4 18 3 15 3 12 15 40 8 35 6 23 6 20 8 30 8 25 5 24 5 20 3 20 3 17 5 22 5 18 1 12 1 10 2 20 2 16 8 25 3 22 6 21 5 18 1 12 1 OEAB B tPLZ 2 21 2 For conditions shown as MIN or MAX, use the appropriate value specified under recommended operating conditions. These parameters are measured with the internal output state of the storage register opposite that of the bus input. 10 tPHL tPLH tPHL tPLH tPHL tPLH tPHL tPZH tPZL tPHZ tPLZ tPZH tPZL tPHZ CLKBA or CLKAB A or B A or B B or A SBA or SAB (with A or B high) A or B SBA or SAB (with A or B low) A or B OEBA A OEBA A OEAB B POST OFFICE BOX 655303 * DALLAS, TEXAS 75265 16 ns ns ns ns ns ns ns ns 11 SN54ALS652, SN54ALS653, SN54AS651, SN54AS652 SN74ALS651A, SN74ALS652A, SN74ALS653, SN74ALS654, SN74AS651, SN74AS652 OCTAL BUS TRANSCEIVERS AND REGISTERS WITH 3-STATE OUTPUTS SDAS066F - DECEMBER 1983 - REVISED OCTOBER 1996 absolute maximum ratings over operating free-air temperature range (unless otherwise noted) Supply voltage, VCC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 V Input voltage, VI: All inputs and A I / O ports . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 V B I / O ports . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5.5 V Operating free-air temperature range, TA: SN54ALS653 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . - 55C to 125C SN74ALS653, SN74ALS654 . . . . . . . . . . . . . . . . . . . . 0C to 70C Storage temperature range, Tstg . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . - 65C to 150C Stresses beyond those listed under "absolute maximum ratings" may cause permanent damage to the device. These are stress ratings only, and functional operation of the device at these or any other conditions beyond those indicated under "recommended operating conditions" is not implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability. recommended operating conditions SN54ALS653 VCC VIH Supply voltage VIL VOH Low-level input voltage High-level output voltage IOH IOL High-level output current fclock Clock frequency tw Pulse duration tsu th TA Operating free-air temperature SN74ALS653 MIN NOM MAX MIN NOM MAX 4.5 5 5.5 4.5 5 5.5 High-level input voltage 2 2 UNIT V V 0.7 0.8 V A ports 5.5 5.5 V B ports - 12 - 15 mA 12 24 mA 35 MHz Low-level output current 0 25 0 CLKBA or CLKAB high 20 14.5 CLKBA or CLKAB low 20 14.5 Setup time before CLKAB or CLKBA A or B 15 10 Hold time after CLKAB or CLKBA A or B 5 0 - 55 125 ns ns ns 0 70 C recommended operating conditions SN74ALS654 VCC VIH Supply voltage VIL VOH Low-level input voltage High-level output voltage IOH IOL High-level output current fclock Clock frequency High-level input voltage MIN NOM MAX 4.5 5 5.5 2 V V A ports 5.5 V B ports - 15 mA 24 mA 35 MHz Low-level output current 0 CLKBA or CLKAB high 14.5 CLKBA or CLKAB low 14.5 Pulse duration tsu th Setup time before CLKAB or CLKBA A or B 10 Hold time after CLKAB or CLKBA A or B 0 TA Operating free-air temperature 0 POST OFFICE BOX 655303 V 0.8 tw 12 UNIT * DALLAS, TEXAS 75265 ns ns ns 70 C SN54ALS652, SN54ALS653, SN54AS651, SN54AS652 SN74ALS651A, SN74ALS652A, SN74ALS653, SN74ALS654, SN74AS651, SN74AS652 OCTAL BUS TRANSCEIVERS AND REGISTERS WITH 3-STATE OUTPUTS SDAS066F - DECEMBER 1983 - REVISED OCTOBER 1996 electrical characteristics over recommended operating free-air temperature range (unless otherwise noted) PARAMETER VIK VOH B ports VOL II TEST CONDITIONS VCC = 4.5 V, VCC = 4.5 V to 5.5 V, II = - 18 mA IOH = - 0.4 mA VCC = 4.5 V IOH = - 3 mA IOH = - 12 mA VCC = 4 4.5 5V Control inputs A or B ports VCC = 5.5 V, VCC = 5.5 V, SN54ALS653 TYP MAX MIN -1.2 VCC - 2 2.4 IOH IO ICC 0.25 0.4 0.35 0.5 0.1 0.1 0.1 0.1 20 20 20 20 - 0.2 - 0.2 - 0.2 - 0.2 VI = 0 0.4 4V A ports VCC = 4.5 V, VOH = 5.5 V B ports VCC = 5.5 V, VO = 2.25 V VCC = 5.5 V 0.4 VI = 5.5 V VCC = 5.5 55V V, A or B ports V V IOL = 24 mA VI = 7 V VI = 2 2.7 7V UNIT 2 0.25 Control inputs IIL 3.2 2 IOH = - 15 mA IOL = 12 mA VCC = 5.5 55V V, A or B ports -1.2 VCC - 2 2.4 3.2 Control inputs IIH SN74ALS653 TYP MAX MIN 0.1 - 20 - 112 - 30 V mA A A mA 0.1 mA - 112 mA Outputs high 47 76 47 76 Outputs low 55 88 55 88 Outputs disabled 55 88 55 88 mA All typical values are at VCC = 5 V, TA = 25C. For I/O ports, the parameters IIH and IIL include the off-state output current. The output conditions have been chosen to produce a current that closely approximates one-half of the true short-circuit output current, IOS. POST OFFICE BOX 655303 * DALLAS, TEXAS 75265 13 SN54ALS652, SN54ALS653, SN54AS651, SN54AS652 SN74ALS651A, SN74ALS652A, SN74ALS653, SN74ALS654, SN74AS651, SN74AS652 OCTAL BUS TRANSCEIVERS AND REGISTERS WITH 3-STATE OUTPUTS SDAS066F - DECEMBER 1983 - REVISED OCTOBER 1996 electrical characteristics over recommended operating free-air temperature range (unless otherwise noted) PARAMETER VIK VOH B ports VOL II Control inputs A or B ports TEST CONDITIONS VCC = 4.5 V, VCC = 4.5 V to 5.5 V, II = - 18 mA IOH = - 0.4 mA 5V VCC = 4 4.5 IOH = - 3 mA IOH = - 15 mA VCC = 4 4.5 5V IOL = 12 mA IOL = 24 mA VCC = 5.5 V, VCC = 5.5 V, VI = 7 V VI = 5.5 V IIH Control inputs A or B ports VCC = 5 5.5 5V V, VI = 2 2.7 7V IIL Control inputs A or B ports VCC = 5 5.5 5V V, VI = 0 0.4 4V VCC = 4.5 V, VCC = 5.5 V, VOH = 5.5 V VO = 2.25 V IOH IO ICC A ports B ports VCC = 5.5 V SN74ALS654 TYP MAX MIN - 1.2 VCC - 2 2.4 UNIT V V 3.2 2 0.25 0.4 0.35 0.5 0.1 0.1 20 20 - 0.2 - 0.2 - 30 V mA A mA 0.1 mA - 112 mA Outputs high 47 76 Outputs low 55 88 Outputs disabled 55 88 mA All typical values are at VCC = 5 V, TA = 25C. For I/O ports, the parameters IIH and IIL include the off-state output current. The output conditions have been chosen to produce a current that closely approximates one-half of the true short-circuit output current, IOS. 14 POST OFFICE BOX 655303 * DALLAS, TEXAS 75265 SN54ALS652, SN54ALS653, SN54AS651, SN54AS652 SN74ALS651A, SN74ALS652A, SN74ALS653, SN74ALS654, SN74AS651, SN74AS652 OCTAL BUS TRANSCEIVERS AND REGISTERS WITH 3-STATE OUTPUTS SDAS066F - DECEMBER 1983 - REVISED OCTOBER 1996 switching characteristics (see Figure 2) PARAMETER FROM (INPUT) TO (OUTPUT) VCC = 4.5 V to 5.5 V, CL = 50 pF, RL = 680 (A outputs), R1 = R2 = 500 (B outputs), TA = MIN to MAX SN54ALS653 MIN fmax tPLH tPHL tPLH tPHL tPLH tPHL tPLH tPHL tPLH tPHL tPLH tPHL tPLH tPHL tPLH tPHL tPLH tPHL tPZH tPZL tPHZ SN74ALS653 MAX 25 CLKBA A CLKAB B A B B A SBA (with B high) A SBA (with B low) A SAB (with A high) B SAB (with A low) B OEBA A OEAB B * DALLAS, TEXAS 75265 MIN MAX 35 MHz 16 71 16 64 6 24 6 22 10 35 10 30 5 20 5 17 5 20 5 18 1.5 18 2 15 8 63 12 56 2 18 2 15 12 68 19 62 5 27 5 25 12 68 19 62 5 27 5 25 8 30 15 35 6 25 6 22 12 40 8 25 6 25 6 22 6 35 6 30 6 27 6 24 7 25 8 22 6 25 6 22 1 14 2 16 1 16 OEAB B tPLZ 2 21 For conditions shown as MIN or MAX, use the appropriate value specified under recommended operating conditions. These parameters are measured with the internal output state of the storage register opposite that of the bus input. POST OFFICE BOX 655303 UNIT ns ns ns ns ns ns ns ns ns ns ns 15 SN54ALS652, SN54ALS653, SN54AS651, SN54AS652 SN74ALS651A, SN74ALS652A, SN74ALS653, SN74ALS654, SN74AS651, SN74AS652 OCTAL BUS TRANSCEIVERS AND REGISTERS WITH 3-STATE OUTPUTS SDAS066F - DECEMBER 1983 - REVISED OCTOBER 1996 switching characteristics (see Figure 2) PARAMETER FROM (INPUT) TO (OUTPUT) VCC = 4.5 V to 5.5 V, CL = 50 pF, RL = 680 (A outputs), R1 = R2 = 500 (B outputs), TA = MIN to MAX UNIT SN74ALS654 MIN fmax tPLH tPHL tPLH tPHL tPLH tPHL tPLH tPHL tPLH tPHL tPLH tPHL tPLH tPHL tPLH tPHL tPLH tPHL tPZH tPZL tPHZ MAX 35 CLKBA A CLKAB B A B B A SBA (with B low) A SBA (with B high) A SAB (with A low) B SAB (with A high) B OEBA A OEAB B 16 64 6 22 10 30 5 17 5 18 2 15 12 56 2 21 19 62 5 25 19 62 5 25 15 35 6 22 8 25 6 22 6 30 6 24 6 22 6 22 1 OEAB B tPLZ 2 For conditions shown as MIN or MAX, use the appropriate value specified under recommended operating conditions. These parameters are measured with the internal output state of the storage register opposite that of the bus input. 16 POST OFFICE BOX 655303 * DALLAS, TEXAS 75265 MHz 14 16 ns ns ns ns ns ns ns ns ns ns ns SN54ALS652, SN54ALS653, SN54AS651, SN54AS652 SN74ALS651A, SN74ALS652A, SN74ALS653, SN74ALS654, SN74AS651, SN74AS652 OCTAL BUS TRANSCEIVERS AND REGISTERS WITH 3-STATE OUTPUTS SDAS066F - DECEMBER 1983 - REVISED OCTOBER 1996 absolute maximum ratings over operating free-air temperature range (unless otherwise noted) Supply voltage, VCC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 V Input voltage, VI: Control inputs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 V I/ O ports . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5.5 V Operating free-air temperature range, TA: SN54AS651, SN54AS652 . . . . . . . . . . . . . . . . . . . - 55C to 125C SN74AS651, SN74AS652 . . . . . . . . . . . . . . . . . . . . . . 0C to 70C Storage temperature range, Tstg . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . - 65C to 150C Stresses beyond those listed under "absolute maximum ratings" may cause permanent damage to the device. These are stress ratings only, and functional operation of the device at these or any other conditions beyond those indicated under "recommended operating conditions" is not implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability. recommended operating conditions SN54AS651 SN54AS652 SN74AS651 SN74AS652 UNIT MIN NOM MAX MIN NOM MAX 4.5 5 5.5 4.5 5 5.5 VCC VIH Supply voltage VIL IOH Low-level input voltage 0.8 0.8 V High-level output current -12 -15 mA IOL fclock* Low-level output current 32 48 mA 90 MHz High-level input voltage 2 Clock frequency 0 2 75 0 CLKBA or CLKAB high 6 5 CLKBA or CLKAB low 7 6 V V tw* Pulse duration tsu* th* Setup time before CLKAB or CLKBA A or B 7 6 ns Hold time after CLKAB or CLKBA A or B 0 0 ns TA Operating free-air temperature - 55 125 0 * On products compliant to MIL-PRF-38535, this parameter is based on characterized data but is not production tested. POST OFFICE BOX 655303 * DALLAS, TEXAS 75265 ns 70 C 17 SN54ALS652, SN54ALS653, SN54AS651, SN54AS652 SN74ALS651A, SN74ALS652A, SN74ALS653, SN74ALS654, SN74AS651, SN74AS652 OCTAL BUS TRANSCEIVERS AND REGISTERS WITH 3-STATE OUTPUTS SDAS066F - DECEMBER 1983 - REVISED OCTOBER 1996 electrical characteristics over recommended operating free-air temperature range (unless otherwise noted) PARAMETER SN54AS651 SN54AS652 TEST CONDITIONS MIN VIK VOH VOL II VCC = 4.5 V, VCC = 4.5 V to 5.5 V, II = - 18 mA IOH = - 2 mA VCC = 4.5 V IOH = - 3 mA IOH = - 12 mA 5V VCC = 4 4.5 Control inputs A or B ports VCC = 5.5 V, VCC = 5.5 V, TYP A or B ports VCC - 2 2.4 A or B ports IO AS651 TYP UNIT MAX - 1.2 3.2 IOH = - 15 mA IOL = 32 mA 2 0.25 0.5 IOL = 48 mA VI = 7 V 0.35 0.5 0.1 0.1 VI = 5.5 V 0.1 0.1 20 20 70 70 - 0.5 - 0.5 - 0.75 - 0.75 VI = 2 2.7 7V VCC = 5.5 55V V, VI = 0 0.4 4V VCC = 5.5 V, VO = 2.25 V Outputs high 110 185 110 185 VCC = 5.5 V Outputs low 120 195 120 195 Outputs disabled 130 195 130 195 Outputs high 120 195 120 195 Outputs low 130 211 130 211 VCC = 5.5 V V V 2 VCC = 5.5 55V V, ICC AS652 MIN VCC - 2 2.4 3.2 Control input IIL MAX - 1.2 Control inputs IIH SN74AS651 SN74AS652 - 30 - 112 - 30 - 112 V mA A A mA mA mA Outputs disabled 130 211 130 211 All typical values are at VCC = 5 V, TA = 25 C. For I/O ports, the parameters IIH and IIL include the off-state output current. The output conditions have been chosen to produce a current that closely approximates one-half of the true short-circuit output current, IOS. 18 POST OFFICE BOX 655303 * DALLAS, TEXAS 75265 SN54ALS652, SN54ALS653, SN54AS651, SN54AS652 SN74ALS651A, SN74ALS652A, SN74ALS653, SN74ALS654, SN74AS651, SN74AS652 OCTAL BUS TRANSCEIVERS AND REGISTERS WITH 3-STATE OUTPUTS SDAS066F - DECEMBER 1983 - REVISED OCTOBER 1996 switching characteristics (see Figure 2) PARAMETER FROM (INPUT) TO (OUTPUT) VCC = 4.5 V to 5.5 V, CL = 50 pF, R1 = 500 , R2 = 500 , TA = MIN to MAX SN54AS651 MIN fmax* tPLH MAX 75 UNIT SN74AS651 MIN MAX 90 MHz 2 11 2 8.5 2 10 2 9 2 12 2 8 1 8 1 7 2 15 2 11 2 11 2 9 2 11 2 10 3 18 3 16 2 10 2 9 2 10 2 9 3 12 3 11 3 20 3 16 2 11 2 OEAB B tPLZ 2 12 2 * On products compliant to MIL-PRF-38535, this parameter is based on characterized data but is not production tested. For conditions shown as MIN or MAX, use the appropriate value specified under recommended operating conditions. These parameters are measured with the internal output state of the storage register opposite that of the bus input. 10 tPHL tPLH tPHL tPLH tPHL tPZH tPZL tPHZ tPLZ tPZH tPZL tPHZ CLKBA or CLKAB A or B A or B B or A SBA or SAB A or B OEBA A OEBA A OEAB B POST OFFICE BOX 655303 * DALLAS, TEXAS 75265 11 ns ns ns ns ns ns ns 19 SN54ALS652, SN54ALS653, SN54AS651, SN54AS652 SN74ALS651A, SN74ALS652A, SN74ALS653, SN74ALS654, SN74AS651, SN74AS652 OCTAL BUS TRANSCEIVERS AND REGISTERS WITH 3-STATE OUTPUTS SDAS066F - DECEMBER 1983 - REVISED OCTOBER 1996 switching characteristics (see Figure 2) PARAMETER FROM (INPUT) TO (OUTPUT) VCC = 4.5 V TO 5.5 V, CL = 50 PF, R1 = 500 , R2 = 500 , TA = MIN TO MAX SN54AS652 MIN fmax* tPLH MAX 75 UNIT SN74AS652 TYP MAX 90 MHz 2 11 2 8.5 2 10 2 9 2 12 2 9 1 8 1 7 2 15 2 11 2 11 2 9 2 11 2 10 3 18 3 16 2 10 2 9 2 10 2 9 3 12 3 11 3 20 3 16 2 11 2 OEAB B tPLZ 2 12 2 * On products compliant to MIL-PRF-38535, this parameter is based on characterized data but is not production tested. For conditions shown as MIN or MAX, use the appropriate value specified under recommended operating conditions. These parameters are measured with the internal output state of the storage register opposite that of the bus input. 10 tPHL tPLH tPHL tPLH tPHL tPZH tPZL tPHZ tPLZ tPZH tPZL tPHZ 20 CLKBA or CLKAB A or B A or B B or A SBA or SAB A or B OEBA A OEBA A OEAB B POST OFFICE BOX 655303 * DALLAS, TEXAS 75265 11 ns ns ns ns ns ns ns SN54ALS652, SN54ALS653, SN54AS651, SN54AS652 SN74ALS651A, SN74ALS652A, SN74ALS653, SN74ALS654, SN74AS651, SN74AS652 OCTAL BUS TRANSCEIVERS AND REGISTERS WITH 3-STATE OUTPUTS SDAS066F - DECEMBER 1983 - REVISED OCTOBER 1996 PARAMETER MEASUREMENT INFORMATION 7V VCC SWITCH POSITION TABLE Open S1 TEST S1 tPLH tPHL Open Open tPZH tPZL Open Closed tPHZ Open tPLZ Closed R1 = 500 From Output Under Test CL = 50 pF (see Note A) Test Point R2 = 500 RL From Output Under Test Test Point CL = 50 pF (see Note A) LOAD CIRCUIT FOR OPEN-COLLECTOR OUTPUTS LOAD CIRCUIT FOR 3-STATE OUTPUTS 3.5 V 3.5 V Timing Input 1.3 V High-Level Pulse 0.3 V tw 0.3 V th tsu Data Input 1.3 V 1.3 V 3.5 V 1.3 V 1.3 V 3.5 V Low-Level Pulse 1.3 V 1.3 V 0.3 V 0.3 V VOLTAGE WAVEFORMS PULSE DURATION VOLTAGE WAVEFORMS SETUP AND HOLD TIMES 3.5 V Output Control 1.3 V 1.3 V 0.3 V 3.5 V Input 1.3 V tPZL 1.3 V tPLZ 0.3 V In-Phase Output VOH 1.3 V VOL 1.3 V Waveform 1 S1 Closed (see Note B) VOH 1.3 V 1.3 V VOL VOLTAGE WAVEFORMS PROPAGATION DELAY TIMES 1.3 V tPHZ tPLH tPHL Out-of-Phase Output 3.5 V tPHL tPLH tPZH Waveform 2 S1 Open (see Note B) VOL 0.3 V VOH 1.3 V 0.3 V 0V VOLTAGE WAVEFORMS ENABLE AND DISABLE TIMES, 3-STATE OUTPUTS NOTES: A. CL includes probe and jig capacitance. B. Waveform 1 is for an output with internal conditions such that the output is low except when disabled by the output control. Waveform 2 is for an output with internal conditions such that the output is high except when disabled by the output control. C. All input pulses are supplied by generators having the following characteristics: PRR 1 MHz, Zo = 50 , tr 2 ns, tf 2 ns. D. The outputs are measured one at a time with one transition per measurement. Figure 2. Load Circuits and Voltage Waveforms POST OFFICE BOX 655303 * DALLAS, TEXAS 75265 21 IMPORTANT NOTICE Texas Instruments and its subsidiaries (TI) reserve the right to make changes to their products or to discontinue any product or service without notice, and advise customers to obtain the latest version of relevant information to verify, before placing orders, that information being relied on is current and complete. All products are sold subject to the terms and conditions of sale supplied at the time of order acknowledgement, including those pertaining to warranty, patent infringement, and limitation of liability. TI warrants performance of its semiconductor products to the specifications applicable at the time of sale in accordance with TI's standard warranty. Testing and other quality control techniques are utilized to the extent TI deems necessary to support this warranty. Specific testing of all parameters of each device is not necessarily performed, except those mandated by government requirements. CERTAIN APPLICATIONS USING SEMICONDUCTOR PRODUCTS MAY INVOLVE POTENTIAL RISKS OF DEATH, PERSONAL INJURY, OR SEVERE PROPERTY OR ENVIRONMENTAL DAMAGE ("CRITICAL APPLICATIONS"). TI SEMICONDUCTOR PRODUCTS ARE NOT DESIGNED, AUTHORIZED, OR WARRANTED TO BE SUITABLE FOR USE IN LIFE-SUPPORT DEVICES OR SYSTEMS OR OTHER CRITICAL APPLICATIONS. INCLUSION OF TI PRODUCTS IN SUCH APPLICATIONS IS UNDERSTOOD TO BE FULLY AT THE CUSTOMER'S RISK. In order to minimize risks associated with the customer's applications, adequate design and operating safeguards must be provided by the customer to minimize inherent or procedural hazards. TI assumes no liability for applications assistance or customer product design. TI does not warrant or represent that any license, either express or implied, is granted under any patent right, copyright, mask work right, or other intellectual property right of TI covering or relating to any combination, machine, or process in which such semiconductor products or services might be or are used. TI's publication of information regarding any third party's products or services does not constitute TI's approval, warranty or endorsement thereof. Copyright 1998, Texas Instruments Incorporated