71
lOR D228VL
REED SWITCH
ORD228VL
Miniature High-performance
nGENERALDESCRIPTION
nFEATURES
nEXTERNAL DIMENSIONS (Unit: mm)
nAPPLICATIONS
44.3±0.3
MAX 14.0
f0.5 MAX f2.2
J2R0015-41-31
l Automotive electronic devices
l Control equipment
l Communication equipment
l Measurement equipment
l Household appliances
The ORD228VL is a small single-contact reed switch designed for general control of medium
level loads less than 100 V. The contacts are sealed within the glass tube with inert gas to maintain
contact reliability.
(1) Reed contacts are hermetically sealed within a glass tube with inert gas and do not receive
any influence from the external atmospheric environment.
(2) Quick response
(3) The structure comprises the operating parts and electrical circuits arranged coaxially. Reed
switches are suited to applications in radio frequency operation.
(4) Reed switches are compact and light weight.
(5) Superior corrosion resistance and wear resistance of the contacts assures stable switching
operation and long life.
(6) With a permanent magnet installed, reed switches economically and easily become
proximity switches.
72
n
99.9
99
95
90
80
70
60
50
40
30
20
10
5
1
0.1
40 60 80 100 mW
AT
50

40

30

20

10

01020304050 AT
AT
AT
mW
VDC
W
pF
VA
V
A
A
100( )
DC
AC
VDC
1050
10
0.5
1.0
l ORD228VL
5min
100max
200 min (PI20)
150 min (PI20)
109min
0.3max
Parameter
Pull-in Value (PI)
Drop-out Value (DO)
Contact resistance (CR)
Breakdown voltage
Insulation resistance
Electrostatic capacitance
Contact rating
Maximum switching voltage
Maximum switching current
Maximum carry current
Rated value
(1) Drop-out Value vs. Pull-in Value (2) Contact resistance
Drop-out Value
Cumulative frequency percent (%)
Pull-in Value
Contact resistance
(Measurement length: 32mm)
Unit
ELECTRICAL CHARACTERISTICS
73
99.9
99
95
90
80
70
60
50
40
30
20
10
5
1
(DC100V)
0.1
10
10
10
11
10
12
10
13
10
14
W
1020304050 AT


400

300

200

100

0
DC:V
1020304050 AT


0.4

0.3

0.2

0.1

0
pF
(1MHz)
ORD228VL l
(3) Breakdown voltage
(5) Electrostatic capacitance
(4) Insulation resistance
Breakdown voltage
Cumulative frequency percent (%)
Pull-in Value
Insulation resistance
Electrostatic capacitance
Pull-in Value
74
0.4max
0.3max
0.05max
5000±400
500
ms
ms
ms
Hz
Hz
1020304050 AT


15

10

5

0
m
l ORD228VL
s
ms
0.5

0.4

0.3

0.2

0.1

01020304050 AT
99.9
99
95
90
80
70
60
50
40
30
20
10
5
1
0.1
4500 5000 5500 Hz
99.9
99
95
90
80
70
60
50
40
30
20
10
5
1
0.1
0.1 0.2 0.3 0.4 ms
0
(1) Operate time
(3) Release time (4) Resonant frequency
(2) Bounce time
Parameter
Operate time
Bounce time
Release time
Resonant frequency
Maximum operating frequency
Rated value Unit
Operate time
Cumulative frequency percent (%)
Cumulative frequency percent (%)
Pull-in Value
(25Hz: 100AT energized)
(25Hz: 100AT energized)
(25Hz: 100AT energized)
Bounce time
Release time
Drop-out Value
Resonant frequency
nOPERATING CHARACTERISTICS
75
n
n
99.9
99
95
90
80
70
60
50
40
30
20
10
5
1
0.1
8246 10kg0

AT
60


50


40


30


20


10


0


80


60


40
mW
ORD228VL l
PI
CR
DO
(2.27kg-10sec)

%
40


30


20


10


0


−10


−20


−30
−40 −20 0 20 40 60 80 100 120 ℃
CR
DO
PI
MECHANICAL CHARACTERISTICS
(1) Lead tensile test (static load)
(1) Temperature characteristics
(2) Lead tensile strength
Pull-in Value • Drop-out Value
Cumulative frequency percent (%)
Contact resistance
Rate of change percent
Before test After test
Temperature
Breaking load
ENVIRONMENTAL CHARACTERISTICS
76
AT
60


50


40


30


20


10


0


80


60


40
mW
PI
CR
DO

AT
60


50


40


30


20


10


0


80


60


40
mW
PI
CR
DO


AT
60


50


40


30


20


10


0


80


60


40
mW
PI
CR
DO

AT
60


50


40


30


20


10


0


80


60


40
mW
l ORD228VL
PI
CR
DO

(2) Temperature cycle
(4) High temperature storage test (5) Low temperature storage test
(3) Temperature and humidity cycle
(-55 to 125 )
-10 to 65
80% to 98%
Pull-in Value • Drop-out ValueContact resistance
Pull-in Value • Drop-out ValueContact resistance
Pull-in Value • Drop-out ValueContact resistance Pull-in Value • Drop-out ValueContact resistance
Before test After test
Before test After test Before test After test
Before test After test
(+125-500H) (-40℃-500H)
77
1500






1000






500
G

AT

AT
60


50


40


30


20


10


0


80


60


40
mW
PI
CR
DO

AT
60


50


40


30


20


10


0


80


60


40
mW
ORD228VL l
PI
CR
DO

1002030405060
(6) Shock test
(7) Vibration test
2) Misoperation area
Pull-in Value • Drop-out Value
Acceleration
Misoperation
area
Pull-in Value
Contact resistance
Before test After test
Pull-in Value • Drop-out ValueContact resistance
Before test After test
(20G: 101000Hz)
(30G: 11ms)
1) Electrical characteristics
(openclose)
78
nLIFEEXPECTANCYDATA:ORD228VL
5
10
1
99.9
90
70
50
30
0.1
(%)
200mA
100mA
400mA
5
10
1
99.9
90
70
50
30
0.1
(%)
5mA1mA100m
l ORD228VL
A

5
10
1
99.9
90
70
50
30
0.1
(%)
100mA10mA5mA

0235710
5
23 5710
6
23 5710
7
23 5710
8
0235710
5
23 5710
6
23 5710
7
23 5710
8
0235710
5
23 5710
6
23 5710
7
23 5710
8
No failure
No failure
Load conditions
Voltage: 5VDC
Current: 100µA , 1mA , 5mA
Load: Resistive load
Cumulative failure rate
Number of operations * Arrow indicates number
of operations where test
was completed.
Load conditions
Voltage: 12VDC
Current: 5mA , 10mA , 100mA
Load: Resistive load
Cumulative failure rate
Number of operations * Arrow indicates number
of operations where test
was completed.
Load conditions
Voltage: 24VDC
Current:
100mA , 200mA , 400mA
Load: Resistive load
Cumulative failure rate