LM92 LM92 +/-0.33C Accurate, 12-Bit + Sign Temperature Sensor and Thermal Window Comparatorwith Two-Wire Interface Literature Number: SNIS110C LM92 0.33C Accurate, 12-Bit + Sign Temperature Sensor and Thermal Window Comparator with Two-Wire Interface General Description The LM92 is a digital temperature sensor and thermal window comparator with an I2CTM Serial Bus interface and an accuracy of 0.33C. The window-comparator architecture of the LM92 eases the design of temperature control systems. The open-drain Interrupt (INT) output becomes active whenever temperature goes outside a programmable window, while a separate Critical Temperature Alarm (T_CRIT_A) output becomes active when the temperature exceeds a programmable critical limit. The INT output can operate in either a comparator or event mode, while the T_CRIT_A output operates in comparator mode only. The host can program both the upper and lower limits of the window as well as the critical temperature limit. Programmable hysterisis as well as a fault queue are available to minimize false tripping. Two pins (A0, A1) are available for address selection. The sensor powers up with default thresholds of 2C THYST, 10C TLOW, 64C THIGH, and 80C T_CRIT. The LM92's 2.7V to 5.5V supply voltage range, Serial Bus interface, 12-bit + sign output, and full-scale range of over 128C make it ideal for a wide range of applications. These include thermal management and protection applications in personal computers, electronic test equipment, office electronics, automotive, medical and HVAC applications. Features Window comparison simplifies design of ACPI compatible temperature monitoring and control. Serial Bus interface Separate open-drain outputs for Interrupt and Critical Temperature shutdown Shutdown mode to minimize power consumption Up to 4 LM92s can be connected to a single bus 12-bit + sign output Operation up to 150C Key Specifications Supply Voltage Supply Current 2.7V to 5.5V operating 30C 350 A (typ) 625 A (max) 5 A (typ) 0.33C (max) 10C to 50C 0.50C (max) -10C to 85C 125C -25C to 150C 1.0C (max) 1.25C (max) 1.5C (max) 0.5C (max) shutdown Temperature Accuracy Linearity Resolution 0.0625C Applications HVAC Medical Electronics Electronic Test Equipment System Thermal Management Personal Computers Office Electronics Automotive I2C(R) is a registered trademark of Philips Corporation. (c) 2010 National Semiconductor Corporation 101051 www.national.com LM92 0.33C Accurate, 12-Bit + Sign Temperature Sensor and Thermal Window Comparator with Two-Wire Interface November 2, 2010 LM92 Simplified Block Diagram 10105101 Connection Diagram SO-8 10105102 LM92 See NS Package Number M08A Ordering Information Order Number Supply Voltage LM92CIM 2.7V to 5.5V LM92CIMX 2.7V to 5.5V Supplied As 2500 Units on Tape and Reel Pin Descriptions Label Pin # Function Typical Connection SDA 1 Serial Bi-Directional Data Line. Open Drain Output From Controller SCL 2 Serial Bus Clock Input From Controller T_CRIT_A 3 Critical Temperature Alarm Open Drain Output Pull Up Resistor, Controller Interrupt Line or System Hardware Shutdown GND 4 Power Supply Ground Ground INT 5 Interrupt Open Drain Output Pull Up Resistor, Controller Interrupt Line +V S 8 Positive Supply Voltage Input DC Voltage from 2.7V to 5.5V User-Set Address Inputs Ground (Low, "0") or +VS (High, "1") A0-A1 www.national.com 7,6 2 LM92 Typical Application 10105103 FIGURE 1. 3 www.national.com LM92 Operating Ratings Absolute Maximum Ratings (Note 1) Supply Voltage Voltage at any Pin Input Current at any Pin Package Input Current (Note 2) T_CRIT_A and INT Output Sink Current T_CRIT_A and INT Output Voltage Storage Temperature ESD Susceptibility (Note 4) Human Body Model Machine Model (Note 1, Note 5) Specified Temperature Range (Note 6) Supply Voltage Range (+VS) -0.3 V to 6.5V -0.3 V to (+VS + 0.3V) 5 mA 20 mA TMIN to TMAX -55C to +150C +2.7V to +5.5V Soldering process must comply with National Semiconductor's Reflow Temperature Profile specifications. Refer to www.national.com/packaging. (Note 3) 10 mA 6.5V -65C to +125C 2500V 250V Electrical Characteristics Temperature-to-Digital Converter Characteristics Unless otherwise noted, these specifications apply for +VS= +2.7V to +5.5V for LM92CIM . Boldface limits apply for TA = TJ = TMIN to TMAX; all other limits TA= TJ= +25C, unless otherwise noted. Parameter Typical (Note 7) Conditions Limits (Note 8) Accuracy (This is a summary. For more T A = +30C, +VS = 3.3V to 4.0V detailed information please see (Note T A = 10C or +50C, +VS = 3.3V to 9)) 4.0V 0.33 T A = -10 C or +85C, +VS = 3.3V to 4.0V 1.00 T A = +125C, +VS = 4.0V 1.25 T A = -25C to 150C, +VS = 4.0V 1.50 Resolution (Note 10) Units (Limit) 0.50 13 0.0625 Linearity (Note 11) C (max) Bits C 0.5 Offset Error of Transfer Function (Note +VS = 4.0V 12) C (max) C (max) Offset Error of Transfer Function Supply 2.7V +VS< 3.6V Sensitivity 3.6V +VS 5.5V C/V (max) C/V (max) Temperature Conversion Time (Note 13) 500 Quiescent Current I2C 0.35 Inactive I2C Active 0.35 1000 ms 0.625 mA (max) mA Shutdown Mode 5 A T HYST Default Temperature (Note 15, Note 16) 2 C T LOW Default Temperature (Note 16) 10 C T HIGH Default Temperature (Note 16) 64 C T C Default Temperature (Note 16) 80 C www.national.com 4 LM92 Digital DC Characteristics Unless otherwise noted, these specifications apply for +VS= +2.7V to +5.5V for LM92CIM . Boldface limits apply for TA = TJ = TMIN to TMAX; all other limits TA= TJ= +25 C, unless otherwise noted. Symbol Parameter V IN(1) SDA and SCL Logical "1" Input Voltage V IN(0) SDA and SCL Logical "0" Input Voltage VIN(HYST) Conditions SDA and SCL Digital Input Hysteresis V IN(1) A0 and A1 Logical "1" Input Voltage V IN(0) A0 and A1 Logical "0" Input Voltage Typical (Note 7) 500 Limits (Note 8) Units (Limit) +VS x 0.7 V (min) +VS+0.3 V (max) -0.3 V (min) +VS x 0.3 V (max) 250 mV (min) 2.0 V (min) +VS+0.3 V (max) -0.3 V (min) 0.7 V (max) I IN(1) Logical "1" Input Current V IN = + VS 0.005 1.0 A (max) I IN(0) Logical "0" Input Current V IN = 0 V -0.005 -1.0 A (max) C IN Capacitance of All Digital Inputs I OH High Level Output Current V OH = + VS 10 A (max) V OL Low Level Output Voltage I OL = 3 mA 0.4 V (max) 0.8 V (max) 20 T_CRIT_A Output Saturation Voltage I OUT = 4.0 mA (Note 14) pF T_CRIT_A Delay t OF Conversions (max) 1 Output Fall Time C L = 400 pF 250 ns (max) I O = 3 mA Serial Bus Digital Switching Characteristics Unless otherwise noted, these specifications apply for +VS= +2.7V to +5.5V for LM92CIM . Boldface limits apply for TA = TJ = TMIN to TMAX; all other limits TA= TJ= +25 C, unless otherwise noted. CL (load capacitance) on output lines = 80 pF unless otherwise specified. Boldface limits apply for TA = TJ = TMIN to TMAX; all other limits TA = TJ = +25 C, unless otherwise noted. Symbol t1 Parameter Conditions Typical (Note 7) Limits (Note 8, Note 18) SCL (Clock) Period 2.5 Data in Set-Up Time to SCL High t3 Data Out Stable after SCL Low t4 t5 tTIMEOUT s(min) ms(max) 1 t2 Units (Limit) 100 ns(min) 0 ns(min) SDA Low Set-Up Time to SCL Low (Start Condition) 100 ns(min) SDA High Hold Time after SCL High (Stop Condition) 100 ns(min) SDA and SCL Time Low for Reset of Serial Interface (Note 17) 75 300 ms (min) ms (max) 5 www.national.com LM92 Serial Bus Communication 10105104 Note 1: Absolute Maximum Ratings indicate limits beyond which damage to the device may occur. DC and AC electrical specifications do not apply when operating the device beyond its rated operating conditions. Note 2: When the input voltage (VI) at any pin exceeds the power supplies (VI < GND or VI > +VS) the current at that pin should be limited to 5 mA. The 20 mA maximum package input current rating limits the number of pins that can safely exceed the power supplies with an input current of 5 mA to four. Note 3: Reflow temperature profiles are different for lead-free and non-lead-free packages. Note 4: Human body model, 100 pF discharged through a 1.5 k resistor. Machine model, 200 pF discharged directly into each pin. Note 5: LM92 JA (thermal resistance, junction-to-ambient) when attached to a printed circuit board with 2 oz. foil is 200 C/W. Note 6: While the LM92 has a full-scale-range in excess of 128 C, prolonged operation at temperatures above 125 C is not recommended. Note 7: Typicals are at TA = 25 C and represent most likely parametric norm. Note 8: Limits are guaranteed to National's AOQL (Average Outgoing Quality Level). Note 9: The limits found in the following table supersede the limits shown in the Electrical Characteristics Table. The Accuracy specification includes errors due to linearity, offset and gain. The accuracy specification includes effects of self heating with negligible digital output loading. Pull-up resistors should be maximized (10k typical recommended), so that self heating due to digital output loading is negligible. Temperature Accuracy Parameter Limits Units Conditions +VS=2.7V +VS=3.3V +VS=4V +VS=5V +VS=5.5V T A = -25C -1.35/+1.50 -1.25/+1.50 -1.25/+1.50 -1.05/+1.70 -1.05/+1.80 C (max) T A = -10C 1.00 -0.90/+1.00 -0.90/+1.00 -0.70/+1.20 -0.70/+1.30 C (max) T A = 0C -0.80/+0.75 -0.70/+0.75 -0.70/+0.75 -0.50/+0.95 -0.50/+1.05 C (max) T A = 10C -0.60/+0.50 0.50 0.50 -0.30/+0.70 -0.30/+0.80 C (max) T A = 30C -0.43/+0.33 0.33 0.33 -0.13/+0.53 -0.13/+0.63 C (max) T A = 50C -0.60/+0.50 0.50 0.50 -0.30/+0.70 -0.30/+0.80 C (max) T A = 85C -1.10/+0.85 -1.00/+0.85 -1.00/+0.85 -0.80/+1.05 -0.80/+1.15 C (max) T A = 125C -1.60/+1.25 -1.50/+1.25 1.25 -1.05/+1.45 -1.05/+1.55 C (max) T A = 150C 1.90 -1.75/+1.50 1.50 -1.30/+1.70 -1.30/+1.80 C (max) Limits at intermediate temperatures can be calculated using a straight line interpolation as shown in the following graphs: Accuracy vs Temperature with +Vs = 5V 10105120 www.national.com 6 LM92 Accuracy vs Temperature with +Vs = 3.3V 10105121 Note 10: 12 bits + sign, two's complement Note 11: Linearity Error is defined as the worse case difference of an actual reading to that of a calculated reading derived from the straight line whose endpoints are measured at 30C and 125C for the range of 30C to 125C or whose endpoints are measured at 30C and -25C for the range of 30C to -25. Note 12: Offset Error calibration should be done at 30C. The residual error of the transfer function is then equivalent to the Accuracy Limit minus the Offset Limit. This does not take into account the power supply sensitivity of the offset error. Nor, does it take into account the error introduced by the calibration system used. Note 13: This specification is provided only to indicate how often temperature data is updated. The LM92 can be read at any time without regard to conversion state (and will yield last conversion result). If a conversion is in process it will be interrupted and restarted after the end of the read. Note 14: For best accuracy, minimize output loading. 10k pull-ups resistors should be sufficient. Higher sink currents can affect sensor accuracy with internal heating. This can cause an error of 0.64 C at full rated sink current and saturation voltage based on junction-to-ambient thermal resistance. Note 15: Hysteresis value adds to the TLOW setpoint value (e.g.: if TLOW setpoint = 10 C, and hysteresis = 2 C, then actual hysteresis point is 10+2 = 12 C); and subtracts from the THIGH and T_CRIT setpoints (e.g.: if THIGH setpoint = 64 C, and hysteresis = 2 C, then actual hysteresis point is 64-2 = 62 C). For a detailed discussion of the function of hysteresis refer to Section 1.1, TEMPERATURE COMPARISON, and Figure 3. Note 16: Default values set at power up. Note 17: Holding the SDA and/or SCL lines Low for a time interval greater than tTIMEOUT will cause the LM92 to reset SCL and SDA to the IDLE state of the serial bus communication (SDA and SCL set High). Note 18: Timing specifications are tested at the bus input logic levels (Vin(0)=0.3xVA for a falling edge and Vin(1)=0.7xVA for a rising edge) when the SCL and SDA edge rates are similar. 10105105 FIGURE 2. Temperature-to-Digital Transfer Function (Non-linear scale for clarity) 7 www.national.com LM92 In either mode, reading any register in the LM92 restarts the conversion. This allows a designer to know exactly when the LM92 begins a comparison. This prevents unnecessary Interrupts just after reprogramming setpoints. Typically, system Interrupt inputs are masked prior to reprogramming trip points. By doing a read just after resetting trip points, but prior to unmasking, unexpected Interrupts are prevented. Avoid programming setpoints so close that their hysteresis values overlap. An example would be that with a THYST value of 2 C then setting THIGH and TLOW to within 4 C of each other will violate this restriction. To be more specific, with THYST set to 2 C assume THIGH set to 64 C. If TLOW is set equal to, or higher than 60 C this restriction is violated. 1.0 Functional Description The LM92 temperature sensor incorporates a band-gap type temperature sensor, 13-bit ADC, and a digital comparator with user-programmable upper and lower limit values. The comparator activates either the INT line for temperatures outside the TLOW and THIGH window, or the T_CRIT_A line for temperatures which exceed T_CRIT. The lines are programmable for mode and polarity. 1.1 TEMPERATURE COMPARISON LM92 provides a window comparison against a lower (TLOW) and upper (THIGH) trip point. A second upper trip point (T_CRIT) functions as a critical alarm shutdown. Figure 3 depicts the comparison function as well as the modes of operation. 1.2 DEFAULT SETTINGS The LM92 always powers up in a known state. LM92 power up default conditions are: 1.1.1 Status Bits The internal Status bits operate as follows: "True": Temperature above a THIGH or T_CRIT is "true" for those respective bits. A "true" for TLOW is temperature below TLOW. " False": Assuming temperature has previously crossed above THIGH or T_CRIT, then the temperature must drop below the points corresponding THYST (THIGH - THYST or T_CRIT - THYST) in order for the condition to be false. For TLOW, assuming temperature has previously crossed below TLOW, a "false" occurs when temperature goes above TLOW + THYST. The Status bits are not affected by reads or any other actions, and always represent the state of temperature vs. setpoints. 1. Comparator Interrupt Mode 2. TLOW set to 10 C 3. THIGH set to 64 C 4. T_CRIT set to 80 C 5. THYST set to 2 C 6. INT and T_CRIT_A active low 7. Pointer set to "00"; Temperature Register The LM92 registers will always reset to these default values when the power supply voltage is brought up from zero volts as the supply crosses the voltage level plotted in the following curve. The LM92 registers will reset again when the power supply drops below the voltage plotted in this curve. Average Power on Reset Voltage vs Temperature 1.1.2 Hardwire Outputs The T_CRIT_A hardwire output mirrors the T_CRIT_A flag, when the flag is true, the T_CRIT_A output is asserted at all times regardless of mode. Reading the LM92 has no effect on the T_CRIT_A output, although the internal conversion is restarted. The behavior of the INT hardwire output is as follows: Comparator Interrupt Mode (Default): User reading part resets output until next measurement completes. If condition is still true, output is set again at end of next conversion cycle. For example, if a user never reads the part, and temperature goes below TLOW then INT becomes active. It would stay that way until temperature goes above TLOW + THYST. However if the user reads the part, the output would be reset. At the end of the next conversion cycle, if the condition is true, it is set again. If not, it remains reset. Event Interrupt Mode: User reading part resets output until next condition "event" occurs (in other words, output is only set once for a true condition, if reset by a read, it remains reset until the next triggering threshold has been crossed). Conversely, if a user never read the part, the output would stay set indefinitely after the first event that set the output. An "event" for Event Interrupt Mode is defined as: 10105118 1.3 SERIAL BUS INTERFACE The LM92 operates as a slave on the Serial Bus, so the SCL line is an input (no clock is generated by the LM92) and the SDA line is a bi-directional serial data line. According to Serial Bus specifications, the LM92 has a 7-bit slave address. The five most significant bits of the slave address are hard wired inside the LM92 and are "10010". The two least significant bits of the address are assigned to pins A1-A0, and are set by connecting these pins to ground for a low, (0); or to +VS for a high, (1). Therefore, the complete slave address is: 1. 2. Transitioning upward across a setpoint, or Transitioning downward across a setpoint's corresponding hysteresis (after having exceeded that setpoint). For example, if a user never read the part, and temperature went below TLOW then INT would become active. It would stay that way forever if a user never read the part. However if the user read the part, the output would be reset. Even if the condition is true, it will remain reset. The temperature must cross above TLOW + THYST to set the output again. www.national.com 1 MSB 8 0 0 1 0 A1 A0 LSB LM92 10105106 Note: Event Interrupt mode is drawn as if the user is reading the part. If the user doesn't read, the outputs would go low and stay that way until the LM92 is read. Comparator Interrupt Mode is drawn as if the user never reads the part. If the user does read, the outputs will go high once read instruction is executed and, if the fault condition still exists, go low at the end of the next conversion. FIGURE 3. Temperature Response Diagram 1.4 TEMPERATURE DATA FORMAT Temperature data can be read from the Temperature and Set Point registers; and written to the Set Point registers. Temperature data can be read at any time, although reading faster than the conversion time of the LM92 will prevent data from being updated. Temperature data is represented by a 13-bit, two's complement word with an LSB (Least Significant Bit) equal to 0.0625 C: Temperature 9 Digital Output Binary Hex +130C 0 1000 0 010 0000 08 20h +125 C 0 0111 1101 0000 07 D0h +80 C 0 0101 0000 0000 05 00h +64 C 0 0100 0000 0000 04 00h +25 C 0 0001 1001 0000 01 90h +10 C 0 0000 1010 0000 00 A0h +2 C 0 0000 0010 0000 00 20h +0.0625 C 0 0000 0000 0001 00 01h 0 C 00 0000 0000 00 00h -0.0625 C 1 1111 1111 1111 1F FFh -25 C 1 1110 0111 0000 1E 70h -55 C 1 1100 1001 0000 1C 90h www.national.com LM92 served on these pins until pull-up current is provided from some external source, typically a pull-up resistor. Choice of resistor value depends on many system factors but, in general, the pull-up resistor should be as large as possible. This will minimize any errors due to internal heating of the LM92. The maximum resistance of the pull up, based on LM92 specification for High Level Output Current, to provide a 2 volt high level, is 30K ohms. 1.5 SHUTDOWN MODE Shutdown mode is enabled by setting the shutdown bit in the Configuration register via the Serial Bus. Shutdown mode reduces power supply current to 5 A typical. T_CRIT_A is reset if previously set. Since conversions are stoped during shutdown, T_CRIT_A and INT will not be operational. The Serial Bus interface remains active. Activity on the clock and data lines of the Serial Bus may slightly increase shutdown mode quiescent current. Registers can be read from and written to in shutdown mode. The LM92 takes miliseconds to respond to the shutdown command. 1.7 FAULT QUEUE A fault queue of 4 faults is provided to prevent false tripping when the LM92 is used in noisy environments. The 4 faults must occur consecutively to set flags as well as INT and T_CRIT_A outputs. The fault queue is enabled by setting bit 4 of the Configuration Register high (see Section 1.11). 1.6 INT AND T_CRIT_A OUTPUT The INT and T_CRIT_A outputs are open-drain outputs and do not have internal pull-ups. A "high" level will not be ob1.8 INTERNAL REGISTER STRUCTURE 10105107 There are four data registers in the LM92, selected by the Pointer register. At power-up the Pointer is set to "00"; the location for the Temperature Register. The Pointer register latches the last location it was set to. In Interrupt Mode, a read from the LM92 resets the INT output. Placing the device in Shutdown mode resets the INT and T_CRIT_A outputs. All registers are read and write, except the Temperature register which is read only. A write to the LM92 will always include the address byte and the Pointer byte. A write to the Configuration register requires one data byte, while the TLOW, THIGH, and T_CRIT registers require two data bytes. Reading the LM92 can take place either of two ways: If the location latched in the Pointer is correct (most of the time it is expected that the Pointer will point to the Temperature register because it will be the data most frequently read from the LM92), then the read can simply consist of an address byte, www.national.com followed by retrieving the corresponding number of data bytes. If the Pointer needs to be set, then an address byte, pointer byte, repeat start, and another address byte plus required number of data bytes will accomplish a read. The first data byte is the most significant byte with most significant bit first, permitting only as much data as necessary to be read to determine the temperature condition. For instance, if the first four bits of the temperature data indicates a critical condition, the host processor could immediately take action to remedy the excessive temperature. At the end of a read, the LM92 can accept either Acknowledge or No Acknowledge from the Master (No Acknowledge is typically used as a signal for the slave that the Master has read its last byte). An inadvertent 8-bit read from a 16-bit register, with the D7 bit low, can cause the LM92 to stop in a state where the SDA line is held low as shown in Figure 4. This can prevent any further bus communication until at least 9 additional clock cy- 10 LM92 cles have occurred. Alternatively, the master can issue clock cycles until SDA goes high, at which time issuing a "Stop" condition will reset the LM92. 10105108 FIGURE 4. Inadvertent 8-Bit Read from 16-Bit Register where D7 is Zero ("0") 1.9 POINTER REGISTER (Selects which registers will be read from or written to): P7 P6 P5 P4 P3 0 0 0 0 0 P2 P1 P0 Register Select P0-P2: Register Select: P2 P1 P0 Register 0 0 0 Temperature (Read only) (Power-up default) 0 0 1 Configuration (Read/Write) 0 1 0 THYST (Read/Write) 0 1 1 T_CRIT (Read/Write) 1 0 0 TLOW (Read/Write) 1 THIGH (Read/Write) 1 1 0 1 1 Manufacturer's ID P3-P7: Must be kept zero. 1.10 TEMPERATURE REGISTER (Read Only): D15 D14 D13 D12 D11 D10 D9 D8 D7 D6 D5 D4 D3 D2 Sign MSB Bit 10 Bit 9 Bit 8 Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 CRIT D1 D0 HIGH LOW Status Bits D0-D2: Status Bits D3-D15: Temperature Data. One LSB = 0.0625C. Two's complement format. 1.11 CONFIGURATION REGISTER (Read/Write): D7 D6 D5 D4 D3 D2 D1 D0 0 0 0 Fault Queue INT Polarity T_CRIT_A Polarity INT Mode Shutdown D0: Shutdown - When set to 1 the LM92 goes to low power shutdown mode. Power up default of "0". D1: Interrupt mode - 0 is Comparator Interrupt mode, 1 is Event Interrupt mode. Power up default of "0". D2, D3: T_CRIT_A and INT Polarity - 0 is active low, 1 is active high. Outputs are open-drain. Power up default of "0" D4: Fault Queue - When set to 1 the Fault Queu is enabled, see Section 1.7. Power up default of "0". 11 www.national.com LM92 D5-D7: These bits are used for production testing and must be kept zero for normal operation. 1.12 THYST, TLOW, THIGH AND T_CRIT_A REGISTERS (Read/Write): D15 D14 D13 D12 D11 D10 D9 D8 D7 D6 D5 D4 D3 D2 D1 D0 Sign MSB Bit 10 Bit 9 Bit 8 Bit7 Bit6 Bit5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 X X X D0-D2: Undefined D3-D15: THYST, TLOW, THIGH or T_CRIT Trip Temperature Data. Power up default is TLOW = 10C, THIGH = 64C, T_CRIT = 80C, THYST = 2C. THYST is subtracted from THIGH, and T_CRIT, and added to TLOW. Avoid programming setpoints so close that their hysteresis values overlap. See Section 1.1. 1.13 Manufacturer's Identification Register (Read only): D15 D14 D13 D12 D11 D10 D9 D8 D7 D6 D5 D4 D3 D2 D1 D0 1 0 0 0 0 0 0 0 0 0 0 0 0 0 0 1 D0-D15: Manufactures ID. www.national.com 12 LM92 2.0 I2C Timing Diagrams 10105109 Typical 2-Byte Read From Preset Pointer Location Such as Temp or Comparison Registers 10105110 Typical Pointer Set Followed by Immediate Read for 2-Byte Register such as Temp or Comparison Registers 10105111 Typical 1-Byte Read from Configuration Register with Preset Pointer FIGURE 5. 10105112 Typical Pointer Set Followed by Immediate Read from Configuration Register 10105113 Configuration Register Write 10105114 Comparison Register Write FIGURE 6. Timing Diagrams 13 www.national.com LM92 issue an interrupt, service the interrupt, and reprogram the window according to the desired granularity of the temperature scale. The reprogrammed window will now have the current temperature inside it, ready to issue an interrupt whenever the temperature deviates from the current window. To understand this graph, assume that at the left hand side the system is at some nominal temperature. For the 1st event temperature rises above the upper window limit, THIGH, causing INT to go active. The system responds to the interrupt by querying the LM92's status bits and determines that THIGH was exceeded, indicating that temperature is rising. The system then reprograms the temperature limits to a value higher by an amount equal to the desired granularity. Note that in Event Interrupt Mode, reprogramming the limits has caused a second, known, interrupt to be issued since temperature has been returned within the window. In Comparator Interrupt Mode, the LM92 simply stops issuing interrupts. The 2nd event is another identical rise in temperature. The 3rd event is typical of a drop in temperature. This is one of the conditions that demonstrates the power of the LM92, as the user receives notification that a lower limit is exceeded in such a way that temperature is dropping. The Critical Alarm Event activates the separate T_CRIT_A output. Typically, this would feed circuitry separate from the processor on the assumption that if the system reached this temperature, the processor might not be responding. 3.0 Application Hints The temperature response graph in Figure 7 depicts a typical application designed to meet ACPI requirements. In this type of application, the temperature scale is given an arbitrary value of "granularity", or the window within which temperature notification events should occur. The LM92 can be programmed to the window size chosen by the designer, and will issue interrupts to the processor whenever the window limits have been crossed. The internal flags permit quick determination of whether the temperature is rising or falling. The T_CRIT limit would typically use its separate output to activate hardware shutdown circuitry separate from the processor. This is done because it is expected that if temperature has gotten this high that the processor may not be responding. The separate circuitry can then shut down the system, usually by shutting down the power supply. Note that the INT and T_CRIT_A outputs are separate, but can be wire-or'd together. Alternatively the T_CRIT_A can be diode or'd to the INT line in such a way that a T_CRIT_A event activates the INT line, but an INT event does not activate the T_CRIT_A line. This may be useful in the event that it is desirable to notify both the processor and separate T_CRIT_A shutdown circuitry of a critical temperature alarm at the same time (maybe the processor is still working and can coordinate a graceful shutdown with the separate shutdown circuit). To implement ACPI compatible sensing it is necessary to sense whenever the temperature goes outside the window, 10105115 Note: Event Interrupt mode is drawn as if the user is reading the part. If the user doesn't read, the outputs would go low and stay that way until the LM92 is read. FIGURE 7. Temperature Response Diagram for ACPI Implementation www.national.com 14 LM92 4.0 Typical Applications 10105116 FIGURE 8. Typical Application 10105117 FIGURE 9. Remote HVAC temperature sensor communicates via 3 wires, including thermostat signals. 15 www.national.com LM92 10105119 FIGURE 10. ACPI Compatible Terminal Alarm Shutdown. By powering the LM92 from auxilary output of the power supply, a non-functioning overheated computer can be powered down to preserve as much of the system as possible. www.national.com 16 LM92 Physical Dimensions inches (millimeters) unless otherwise noted 8-Lead (0.150 Wide) Molded Small Outline Package (SOP), JEDEC Order Number LM92CIM or LM92CIMX NS Package Number M08A 17 www.national.com LM92 0.33C Accurate, 12-Bit + Sign Temperature Sensor and Thermal Window Comparator with Two-Wire Interface Notes For more National Semiconductor product information and proven design tools, visit the following Web sites at: www.national.com Products Design Support Amplifiers www.national.com/amplifiers WEBENCH(R) Tools www.national.com/webench Audio www.national.com/audio App Notes www.national.com/appnotes Clock and Timing www.national.com/timing Reference Designs www.national.com/refdesigns Data Converters www.national.com/adc Samples www.national.com/samples Interface www.national.com/interface Eval Boards www.national.com/evalboards LVDS www.national.com/lvds Packaging www.national.com/packaging Power Management www.national.com/power Green Compliance www.national.com/quality/green Switching Regulators www.national.com/switchers Distributors www.national.com/contacts LDOs www.national.com/ldo Quality and Reliability www.national.com/quality LED Lighting www.national.com/led Feedback/Support www.national.com/feedback Voltage References www.national.com/vref Design Made Easy www.national.com/easy www.national.com/powerwise Applications & Markets www.national.com/solutions Mil/Aero www.national.com/milaero PowerWise(R) Solutions Serial Digital Interface (SDI) www.national.com/sdi Temperature Sensors www.national.com/tempsensors SolarMagicTM www.national.com/solarmagic PLL/VCO www.national.com/wireless www.national.com/training PowerWise(R) Design University THE CONTENTS OF THIS DOCUMENT ARE PROVIDED IN CONNECTION WITH NATIONAL SEMICONDUCTOR CORPORATION ("NATIONAL") PRODUCTS. NATIONAL MAKES NO REPRESENTATIONS OR WARRANTIES WITH RESPECT TO THE ACCURACY OR COMPLETENESS OF THE CONTENTS OF THIS PUBLICATION AND RESERVES THE RIGHT TO MAKE CHANGES TO SPECIFICATIONS AND PRODUCT DESCRIPTIONS AT ANY TIME WITHOUT NOTICE. NO LICENSE, WHETHER EXPRESS, IMPLIED, ARISING BY ESTOPPEL OR OTHERWISE, TO ANY INTELLECTUAL PROPERTY RIGHTS IS GRANTED BY THIS DOCUMENT. TESTING AND OTHER QUALITY CONTROLS ARE USED TO THE EXTENT NATIONAL DEEMS NECESSARY TO SUPPORT NATIONAL'S PRODUCT WARRANTY. EXCEPT WHERE MANDATED BY GOVERNMENT REQUIREMENTS, TESTING OF ALL PARAMETERS OF EACH PRODUCT IS NOT NECESSARILY PERFORMED. NATIONAL ASSUMES NO LIABILITY FOR APPLICATIONS ASSISTANCE OR BUYER PRODUCT DESIGN. BUYERS ARE RESPONSIBLE FOR THEIR PRODUCTS AND APPLICATIONS USING NATIONAL COMPONENTS. PRIOR TO USING OR DISTRIBUTING ANY PRODUCTS THAT INCLUDE NATIONAL COMPONENTS, BUYERS SHOULD PROVIDE ADEQUATE DESIGN, TESTING AND OPERATING SAFEGUARDS. EXCEPT AS PROVIDED IN NATIONAL'S TERMS AND CONDITIONS OF SALE FOR SUCH PRODUCTS, NATIONAL ASSUMES NO LIABILITY WHATSOEVER, AND NATIONAL DISCLAIMS ANY EXPRESS OR IMPLIED WARRANTY RELATING TO THE SALE AND/OR USE OF NATIONAL PRODUCTS INCLUDING LIABILITY OR WARRANTIES RELATING TO FITNESS FOR A PARTICULAR PURPOSE, MERCHANTABILITY, OR INFRINGEMENT OF ANY PATENT, COPYRIGHT OR OTHER INTELLECTUAL PROPERTY RIGHT. LIFE SUPPORT POLICY NATIONAL'S PRODUCTS ARE NOT AUTHORIZED FOR USE AS CRITICAL COMPONENTS IN LIFE SUPPORT DEVICES OR SYSTEMS WITHOUT THE EXPRESS PRIOR WRITTEN APPROVAL OF THE CHIEF EXECUTIVE OFFICER AND GENERAL COUNSEL OF NATIONAL SEMICONDUCTOR CORPORATION. As used herein: Life support devices or systems are devices which (a) are intended for surgical implant into the body, or (b) support or sustain life and whose failure to perform when properly used in accordance with instructions for use provided in the labeling can be reasonably expected to result in a significant injury to the user. A critical component is any component in a life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support device or system or to affect its safety or effectiveness. National Semiconductor and the National Semiconductor logo are registered trademarks of National Semiconductor Corporation. All other brand or product names may be trademarks or registered trademarks of their respective holders. Copyright(c) 2010 National Semiconductor Corporation For the most current product information visit us at www.national.com National Semiconductor Americas Technical Support Center Email: support@nsc.com Tel: 1-800-272-9959 www.national.com National Semiconductor Europe Technical Support Center Email: europe.support@nsc.com National Semiconductor Asia Pacific Technical Support Center Email: ap.support@nsc.com National Semiconductor Japan Technical Support Center Email: jpn.feedback@nsc.com IMPORTANT NOTICE Texas Instruments Incorporated and its subsidiaries (TI) reserve the right to make corrections, modifications, enhancements, improvements, and other changes to its products and services at any time and to discontinue any product or service without notice. Customers should obtain the latest relevant information before placing orders and should verify that such information is current and complete. All products are sold subject to TI's terms and conditions of sale supplied at the time of order acknowledgment. TI warrants performance of its hardware products to the specifications applicable at the time of sale in accordance with TI's standard warranty. Testing and other quality control techniques are used to the extent TI deems necessary to support this warranty. Except where mandated by government requirements, testing of all parameters of each product is not necessarily performed. TI assumes no liability for applications assistance or customer product design. Customers are responsible for their products and applications using TI components. To minimize the risks associated with customer products and applications, customers should provide adequate design and operating safeguards. TI does not warrant or represent that any license, either express or implied, is granted under any TI patent right, copyright, mask work right, or other TI intellectual property right relating to any combination, machine, or process in which TI products or services are used. Information published by TI regarding third-party products or services does not constitute a license from TI to use such products or services or a warranty or endorsement thereof. Use of such information may require a license from a third party under the patents or other intellectual property of the third party, or a license from TI under the patents or other intellectual property of TI. Reproduction of TI information in TI data books or data sheets is permissible only if reproduction is without alteration and is accompanied by all associated warranties, conditions, limitations, and notices. Reproduction of this information with alteration is an unfair and deceptive business practice. TI is not responsible or liable for such altered documentation. Information of third parties may be subject to additional restrictions. Resale of TI products or services with statements different from or beyond the parameters stated by TI for that product or service voids all express and any implied warranties for the associated TI product or service and is an unfair and deceptive business practice. TI is not responsible or liable for any such statements. TI products are not authorized for use in safety-critical applications (such as life support) where a failure of the TI product would reasonably be expected to cause severe personal injury or death, unless officers of the parties have executed an agreement specifically governing such use. Buyers represent that they have all necessary expertise in the safety and regulatory ramifications of their applications, and acknowledge and agree that they are solely responsible for all legal, regulatory and safety-related requirements concerning their products and any use of TI products in such safety-critical applications, notwithstanding any applications-related information or support that may be provided by TI. Further, Buyers must fully indemnify TI and its representatives against any damages arising out of the use of TI products in such safety-critical applications. TI products are neither designed nor intended for use in military/aerospace applications or environments unless the TI products are specifically designated by TI as military-grade or "enhanced plastic." Only products designated by TI as military-grade meet military specifications. Buyers acknowledge and agree that any such use of TI products which TI has not designated as military-grade is solely at the Buyer's risk, and that they are solely responsible for compliance with all legal and regulatory requirements in connection with such use. TI products are neither designed nor intended for use in automotive applications or environments unless the specific TI products are designated by TI as compliant with ISO/TS 16949 requirements. Buyers acknowledge and agree that, if they use any non-designated products in automotive applications, TI will not be responsible for any failure to meet such requirements. Following are URLs where you can obtain information on other Texas Instruments products and application solutions: Products Applications Audio www.ti.com/audio Communications and Telecom www.ti.com/communications Amplifiers amplifier.ti.com Computers and Peripherals www.ti.com/computers Data Converters dataconverter.ti.com Consumer Electronics www.ti.com/consumer-apps DLP(R) Products www.dlp.com Energy and Lighting www.ti.com/energy DSP dsp.ti.com Industrial www.ti.com/industrial Clocks and Timers www.ti.com/clocks Medical www.ti.com/medical Interface interface.ti.com Security www.ti.com/security Logic logic.ti.com Space, Avionics and Defense www.ti.com/space-avionics-defense Power Mgmt power.ti.com Transportation and Automotive www.ti.com/automotive Microcontrollers microcontroller.ti.com Video and Imaging RFID www.ti-rfid.com OMAP Mobile Processors www.ti.com/omap Wireless Connectivity www.ti.com/wirelessconnectivity TI E2E Community Home Page www.ti.com/video e2e.ti.com Mailing Address: Texas Instruments, Post Office Box 655303, Dallas, Texas 75265 Copyright (c) 2011, Texas Instruments Incorporated