SPECIFICATION
MODEL APV-16-5 APV-16-12 APV-16-15 APV-16-24
DC VOLTAGE
RATED CURRENT
CURRENT RANGE
RATED POWER
OUTPUT
LINE REGULATION
LOAD REGULATION
SETUP, RISE TIME Note.6
HOLD UP TIME (Typ.)
VOLTAGE RANGE Note.4
FREQUENCY RANGE
EFFICIENCY (Typ.)
AC CURRENT
INPUT
INRUSH CURRENT(Typ.)
LEAKAGE CURRENT
SAFETY STANDARDS Note.8
WORKING TEMP.
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
MTBF
DIMENSIONOTHERS
NOTE
PACKING
OVER LOAD
OVER VOLTAGE
5V 12V 15V 24V
2.6A 1.25A 1A 0.67A
0 ~ 2.6A 0 ~ 1.25A 0 ~ 1A 0 ~ 0.67A
13W 15W 15W 16.08W
100mVp-p 120mVp-p 120mVp-p 150mVp-p
±5.0%
±1.0%
±2.0%
1500ms, 30ms / 230VAC 1500ms,30ms / 115VAC at full load
90 ~ 264VAC 127 ~ 370VDC
47 ~ 63Hz
76% 80% 81% 83%
5.75 ~ 6.75V 13.8 ~ 16V 17.5 ~ 21V 27.6 ~ 32.4V
0.3A/230VAC 0.5A/115VAC
COLD START 50A(twidth=185 s measured at 50% Ipeak) at 230VACμ
0.25mA / 240VAC
Above 105% rated output power
Protection type : Hiccup mode, recovers automatically after fault condition is removed
-30 ~ +70(Refer to "Derating Curve")
20 ~ 90% RH non-condensing
-40 ~ +80, 10 ~ 95% RH
±0.03%/ (0 ~ 50)
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
77*40*29mm (L*W*H)













Protection type : Shut off o/p voltage, clamping by zener diode
16W Single Output Switching Power Supply






 









APV-16 series
RIPPLE & NOISE (max.) Note.2
VOLTAGE TOLERANCE Note.3
ENVIRONMENT
SAFETY &
EMC
PROTECTION
20ms/230VAC 12ms/115VAC at full load
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
I/P-O/P:3.75KVAC
I/P-O/P:>100M Ohms / 500VDC / 25/ 70% RH
File Name:APV-16-SPEC 2019-07-26
1145.7K hrs min. MIL-HDBK-217F (25)
0.1Kg; 120pcs/14Kg/1.06CUFT
EMC IMMUNITY
Compliance to EN55032,EN61000-3-2 Class A,EN61000-3-3, EAC TP TC 020
Compliance to EN55024,EN61000-4-2,3,4,5,6,8,11; light industry level(surge 2KV), criteria A, EAC TP TC 020
EMC EMISSION
 
UL8750,CSA C22.2 No.250.0-08, ENEC EN61347-1,EN61347-2-13,EN62384 Independent,BIS IS15885(except for 15V),
EAC TP TC 004,IP42 Approved; design refer to EN60950-1
MAX. No. of PSUs on 16A
CIRCUIT BREAKER 13 units (circuit breaker of type B) / 22 units (circuit breaker of type C) at 230VAC
LPS IP42
IS 15885(Part 2/Sec13)
R-41027766
THOMAS SAMUEL
THOMAS SAMUEL


File Name:APV-16-SPEC 2019-07-26
Mechanical Specification Unit:mm
Derating Curve Static Characteristics
AMBIENT TEMPERATURE ()
LOAD (%)
-30 0 10 20 30 40 50 70
20
40
60
80
100
(HORIZONTAL)
Block Diagram
DETECTION
PWM
CIRCUIT
EMI FILTER
POWER
SWITCH-
FILTER
&
RECTIFIERS +V
-V
I/P
ING
CONTROL
50
16W Single Output Switching Power Supply APV-16 se r i e s
INPUT VOLTAGE (VAC) 60Hz
90 100 200 220
210 230 250
240 264
LOAD (%)
90
100
80
70
60
50
40
fosc : 67KHz
RECTIFIERS
60
77
40
82.5
90
150±10
150±10
15.5
29
UL1569 20AWG
UL1569 18AWG
+V(Red)
-V(Black)
AC/N(Blue)
AC/L(Brown)
19
31
T case
T case: Max. Case Temperature