Think Automation and beyond... o16mm XA Series Emergency Stop Switches (Illuminated Type) o16mm XA Series Illuminated Emergency Stop Switches The World's First o16 mm, 4-contact Emergency Stop Switch. Compact size - only 27.9 mm deep behind the panel. * 1 to 4NC main contacts and 1NO monitor contact * The depth behind the panel is only 27.9 mm for 1 to 4 contacts. * IDEC's original "Safe break action" ensures that the contacts open when the contact block is detached from the operator. * Push-to-lock, Pull or Turn-to-reset operator * Two operator sizes: o29 and o40 mm * Safety lock mechanism (IEC60947-5-5, 6.2) * Degree of protection IP65 (IEC60529) * Direct opening action mechanism (IEC60947-5-5, 5.2, IEC60947-5-1, Annex K) * UL, c-UL recognized. EN compliant * RoHS compliant (EU directive 2002/95/EC). Contains no lead, cadmium, mercury, hexavalent chromium, PBB, or PBDE. Direct Opening Action Specifications Illumination Ratings Rated Voltage Operating Voltage Rated Current 24V AC/DC 24V AC/DC 10% 11 mA Note: Except for stop switches (operator color: gray). Contact Ratings (NC main contacts/NO monitor contact) Rated Insulation Voltage (Ui) 300V (illuminated part: 60V) Rated Current (Ith) 5A Rated Operating Voltage (Ue) Rated Operating Current AC 50/60 Hz Main Contacts DC AC 50/60 Hz Monitor Contacts DC UL508 CSA C22.2 No. 14 GB14048.5 2 Operating Temperature -25 to +55C (no freezing) Operating Humidity 45 to 85% RH (no condensation) Storage Temperature -45 to +80C Operating Force Push to lock: 10.5N Pull to reset: 10N Turn to reset: 0.16 N*m Minimum Force Required for Direct Opening Action 60N Minimum Operator Stroke Required for Direct Opening Action 4.0 mm 125V 250V Resistive Load (AC-12) - 3A 3A Inductive Load (AC-15) - 1.5A 1.5A Maximum Operator Stroke 4.5 mm Resistive Load (DC-12) 2A 0.4A 0.2A Contact Resistance 50 m maximum (initial value) Inductive Load (DC-13) Insulation Resistance 100 M minimum (500V DC megger) 1A 0.22A 0.1A Overvoltage Category II Resistive Load (AC-12) - 1.2A 0.6A Impulse Withstand Voltage 2.5 kV Inductive Load (AC-14) - 0.6A 0.3A Resistive Load (DC-12) 2A 0.4A 0.2A Inductive Load (DC-13) 1A 0.22A 0.1A Mark Approval Organization/ File No. UL/c-UL File No. E68961 TUV Product Service EN60947-5-1 EN60947-5-5 (Note) IEC60947-5-1, EN60947-5-1 IEC60947-5-5 (Note), EN60947-5-5 (Note) JIS C8201-5-1, UL508, CSA C22.2 No. 14 30V * Minimum applicable load: 5V AC/DC, 1 mA (reference value) (Operating area may vary according to the operating conditions and load types.) * The rated operating currents are measured at resistive/inductive load types specified in IEC 60947-5-1. Standard Applicable Standards European Commission's Low Voltage Directive CCC No. 2005010305150899 Pollution Degree 3 (inside LED unit: 2) Operation Frequency 900 operations/hour Shock Resistance Operating extremes: 150 m/s2 Damage limits: 1000 m/s2 Vibration Resistance Operating extremes: 10 to 500 Hz, amplitude 0.35 mm acceleration 50 m/s2 Damage limits: 10 to 500 Hz, amplitude 0.35 mm acceleration 50 m/s2 Mechanical Life 250,000 operations minimum Electrical Life 100,000 operations minimum 250,000 operations minimum (24V AC/DC, 100 mA) Degree of Protection IP65 (IEC60529) Short-circuit Protection 250V/10A fuse (Type aM, IEC60269-1/IEC60269-2) Conditional Short-circuit Current 1000A Terminal Style Solder terminal, PC Board terminal Recommended Tightening Torque for Locking Ring 0.88 N*m Connectable Wire 1.25 mm2 maximum (AWG16 maximum) Soldering Conditions 310 to 350C, 3 seconds maximum Weight o29 mm type: 23g, o40 mm type: 28g Note: Except for stop switches (operator color: gray). o16mm XA Series Illuminated Emergency Stop Switches Types Illuminated Solder Terminal / PC Board Terminal Types Appearance Type No. NC Main Contact NO Monitor Contact 1NC -- XA1E-LV301Q4R XA1E-LV301Q4VR 2NC -- XA1E-LV302Q4R XA1E-LV302Q4VR 3NC -- XA1E-LV303Q4R XA1E-LV303Q4VR 4NC -- XA1E-LV304Q4R XA1E-LV304Q4VR 1NC 1NO XA1E-LV311Q4R XA1E-LV311Q4VR 2NC 1NO XA1E-LV312Q4R XA1E-LV312Q4VR 3NC 1NO XA1E-LV313Q4R XA1E-LV313Q4VR 1NC -- XA1E-LV401Q4R XA1E-LV401Q4VR 2NC -- XA1E-LV402Q4R XA1E-LV402Q4VR 3NC -- XA1E-LV403Q4R XA1E-LV403Q4VR 4NC -- XA1E-LV404Q4R XA1E-LV404Q4VR 1NC 1NO XA1E-LV411Q4R XA1E-LV411Q4VR 2NC 1NO XA1E-LV412Q4R XA1E-LV412Q4VR 3NC 1NO XA1E-LV413Q4R XA1E-LV413Q4VR o29mm Operator o40mm Operator Operator Color Terminal Style Solder Terminal PC Board Terminal Dark red only * Terminal cover (XA9Z-VL2) is ordered separately. Dimensions Panel Cut-out Mounting Panel Thickness: 0.5 to 3.7 4.5 * Illuminated Type +0.2 1.7 0 o1 6.2 +0. +0.2 17.9 0 27.2 19.8 8.7 0 2 All dimensions in mm. Rubber Gasket 8 Locking Ring o2 9. 0 o4 9 30.4 o2 Terminal Cover XA9Z-VL2 29.4 2.1 3.1 25.8 20.6 25.8 o29mm Operator 30.4 30.4 20.6 o40mm Operator Solder Terminal Type PC Board Terminal Type PC Board Layout (Bottom View) LED Unit Internal Circuit 19.8 8.7 X1 R1 R2 4.5 LED les .2 o1 ho - R3 LED chip Protection diode 11.2 Terminal Arrangement (Bottom View) 3-o 1.7 ho les 6.5 Illuminated Type * NC main contacts only NC main contacts: Terminals 1-2 Mounting Hole Layout TOP TOP Left X1 X2 X * The values shown above are the minimum dimensions for mounting with other o16 mm pushbuttons. For other control units of different sizes and styles, determine the values according to the dimensions, operation, and wiring convenience. 2 1 2 Right 1NC: Terminals on right 2NC: Terminals on right and left 3NC: Terminals on right, left, and top Left 2 LED X1 Right X2 2 50 mm minimum 1 2 40 mm minimum o40mm Operator 1 o29mm Operator 2 LED 1 1 Y 2 X 1 +0.2 o16.2 0 Y * With NO monitor contacts NC main contacts: Terminals 1-2 NO monitor contacts: Terminals 3-4 1 8.7 19.8 10 X2 4 3 1NC: Terminals on top 2NC: Terminals on right and left 3 o16mm XA Series Illuminated Emergency Stop Switches Nameplates Description Legend Type No. (blank) For o29mm Operator For o40mm Operator Material Plate Color Legend Color Polyamide Yellow Black HAAV-0 EMERGENCY STOP HAAV-27 (blank) HAAV4-0 EMERGENCY STOP HAAV4-27 Accessories and Replacement Parts Description & Appearance Material Type No. Ordering Type No. Package Quantity 2 Remarks Terminal Cover LED Unit PBT XA9Z-VL2 XA9Z-VL2PN02 For Solder Terminal XA9Z-LED2R XA9Z-LED2R For PC Board Terminal XA9Z-LED2VR XA9Z-LED2VR * White * Used for solder terminals. * Replacement LED unit/ 1 LED Unit Removal Tool Stainless Steel MT-101 MT-101 * Used for removing the LED unit. Removing the LED Unit Installing the LED Unit Pull out the LED unit while squeezing the latches on the LED unit using the LED unit removal tool (MT-101). Align the to of the LED unit with the TOP marking on the contact block. Push the LED unit into the contact block. Squeeze the LED unit on the latches and pull out. TOP side Latches TOP side Safety Precautions * Turn off power to the XA series emergency stop switch before starting installation, removal, wiring, maintenance, and inspection of the relays. Failure to turn power off may cause electrical shock or fire hazard. * Use the LED unit removal tool when replacing the LED unit to avoid burn on your hands. * Use wires of the proper size to meet the voltage and current requirements, and solder the wires correctly. If soldering is incomplete, the wire may heat during operation, causing fire hazard. * Read the user's manual to ensure correct operation before starting installation, wiring, operation, maintenance, and inspection of the XA emergency stop switches. Specifications and other descriptions in this catalog are subject to change without notice. 7-31, Nishi-Miyahara 1-Chome, Yodogawa-ku, Osaka 532-8550, Japan Tel: +81-6-6398-2571, Fax: +81-6-6392-9731 E-mail: products@idec.co.jp IDEC CORPORATION (USA) IDEC ELEKTROTECHNIK GmbH IDEC IZUMI (H.K.) CO., LTD. 1175 Elko Drive, Sunnyvale, CA 94089-2209, USA Tel: +1-408-747-0550 / (800) 262-IDEC (4332) Fax: +1-408-744-9055 / (800) 635-6246 E-mail: opencontact@idec.com Wendenstrasse 331, D-20537 Hamburg, Germany Tel: +49-40-25 30 54 10, Fax: +49-40-25 30 54 24 E-mail: service@idec.de IDEC CANADA LIMITED 2/3 Macro Court, Rowville, Victoria 3178, Australia Tel: +61-3-9763-3244, Toll Free: 1800-68-4332, Fax: +61-3-9763-3255, E-mail: sales@au.idec.com Unit 22-151, Brunel Road Mississauga, Ontario, L4Z 1X3, Canada Tel: +1-905-890-8561, Toll Free: (888) 317-4332, Fax: +1-905-890-8562 E-mail: sales@ca.idec.com IDEC ELECTRONICS LIMITED www.idec.com Unit 2, Beechwood, Chineham Business Park, Basingstoke, Hampshire, RG24 8WA, UK Tel: +44-1256-321000, Fax: +44-1256-327755 E-mail: sales@uk.idec.com IDEC AUSTRALIA PTY. LTD. IDEC IZUMI ASIA PTE. LTD. No. 31, Tannery Lane #05-01, Dragon Land Building, Singapore 347788 Tel: +65-6746-1155, Fax: +65-6844-5995 E-mail: info@sg.idec.com Unit 1505-07, DCH Commercial Centre No. 25, Westlands Road, Quarry Bay, Hong Kong Tel: +852-2803-8989, Fax: +852-2565-0171 E-mail: info@hk.idec.com IDEC (SHANGHAI) CORPORATION Room 608-609, 6F, Gangtai Plaza, No. 700, Yan'an East Road, Shanghai 200030, China Tel: +86-21-5353-1000, Fax: +86-21-5353-1263 E-mail: idec@cn.idec.com IDEC TAIWAN CORPORATION 8F, No. 79, Hsin Tai Wu Road, Sec. 1, Hsi-Chih, Taipei County, Taiwan Tel: +886-2-2698-3929, Fax: +886-2-2698-3931 E-mail: service@idectwn.com.tw Cat. No. EP1093-0 FEBRUARY 2006 14DNP PRINTED IN JAPAN